KS-0247-K - 26/09/2017 Rev L

Imperial West Block F

Document Title: Speedline Project Pack

Document Number: IWBF-4300-TC-SP-0001

Revision: P10

Purpose of Issue: For Approval

Date: 26/09/2017

Revision History
Issue Date Purpose of Issue Originator
P01 26-Oct-16 First Issue For Approval David Taylor
P02 06-Dec-16 Updates made reissued for approval David Taylor
P03 09-Jan-17 Updates made reissued for approval David Taylor
P04 15-May-17 Further updates Kieron Swift
P05 01-June-17 Additional party wall detail Kieron Swift
P06 29-June -17 Additional wall details Added to rear of pack K.Shaddick
P07 14July17 ChangeThermalShaftwalltoincludeRockwool KShaddick
P08 25/07/17 Back to Back Putty pads added K Shaddick
P09 08/09/17 Changes to MR boards K Shaddick
P10 26/09/17 Type 18a Amends K Shaddick

Page 1 of 168
KS-0247-K - 26/09/2017 Rev L

Project Pack
Project Number: SR-0247K /2016
Imperial West Block F
London

Created for: Laing O'Rourke

Page 2 of 168
KS-0247-K - 26/09/2017 Rev L

Speedline Specification for Approval


The following document should be read in conjunction with the project acoustic and fire
strategies including duty requirements.

All sound insulation data is based on laboratory evaluation of the building element in
isolation and cannot reproduce your installed site local conditions.

The actual tests carried out are used to offer an order of magnitude comparison for the
performance of the various systems. Sound Insulation on site is a function of the partition
chosen and the associated structures in which it is installed. We cannot take any
responsibility for overall design and we would advise that specialist advice is sought at an
early stage of design. This document must be read in conjunction with the Speedline Metal
Solutions Guide.

All test data and system specifications are for systems constructed with materials and
components as shown. The inclusion of other components without prior approval or
constructed on site contrary to these documents will invalidate test certification and system
performance.

The information is provided in good faith and on the basis of details received, which are
assumed to include all relevant facts.

Maximum height calculated on Limiting Deflection L/240 @ Max Air Pressure 200pa.

Page 3 of 168
KS-0247-K - 26/09/2017 Rev L

Contents

Speedline Systems Assurance

Systems Content

Materials Schedule

Specifications -Specification Data Sheets - Typical Details

General Information & K10 Notes

Contacts

Page 4 of 168
KS-0247-K - 26/09/2017 Rev L

Page 5 of 168
KS-0247-K - 26/09/2017 Rev L

Summary of Proposed Systems


Project: SR 0247K Imperial West Block F
Date of Issue: 26 Sept 2017
Based on:

Fire Res. Sound Max Nom. Duty


K10 Ref &/or Type Speedline Reference Description - K (mins) Ins. Height Width Rating
BS476 (RwdB) (mm) (mm) BS5234
K10.125A - Wall Type WT-01 PW50-K-60(50)(200) Twin SPEEDLINE 50mm C St ud Part it ion wit h 2x Knauf 15mm Soundshield Plus, 50mm A PR, M D1 M esh 120 62(-2,-7) 6200 M in 200 Severe

SPEEDLINE 50mm SPS C St ud Part it ion wit h Knauf 15mm Wallboard, 25mm A PR (insulat ion not required on
K10.125B Wall Type WT-02 50-K-52(25) 30 41 2800 82 Heavy
WT-02A)
Wall Type WT-03 50-K-56 SPEEDLINE 50mm SPS C St ud Part it ion wit h Knauf 15mm Fire Panel, 60 NA 2800 82 Heavy

120 Inc 65Dnt w Inc


K10.125D Wall Type WT-04 IWL92-K-62(25) SPEEDLINE 92mm PI St ud Lining wit h 2x Knauf 15mm Fire Panel, 25mm A PR 5400 NA Severe
B ackground Background
SPEEDLINE Wall Lining Channel wit h Knauf 15mm Soundshield Plus,
K10.145A/ B Wall Type WT-05 & 05A WL507-K-54 NA NA NA NA NA
Type WT-05A Wit h VCL
120 Inc 65Dnt w Inc
K10.125E Wall Type WT-07 IWL50-K-57(25) SPEEDLINE 50mm PI St ud Lining wit h 2x Knauf 12.5mm Wallboard, 25mm APR 2700 NA Severe
B ackground Background
K10.125F Wall Type WT-08 IWL50-K-57 SPEEDLINE 50mm PI St ud Lining wit h 2x Knauf 12.5mm Wallboard, NA NA 2700 NA Severe

K10.145E Wall Type WT-09 SE60-K-62 SPEEDLINE 60mm PI Shaf t Encasement wit h 2x Knauf 15mm Fire Panel, Knauf 19mm Coreboard, 120 40 4500 92 Severe

SPEEDLINE Wall Lining Channel wit h Knauf 12.5mm Wallboard & Speedline 92.5mm Thermal Laminat e, 25mm 240Inc 65Dnt w Inc
Wall Type WT-12 WL507-K-57(25)M od NA NA NA
APR B ackground Background
Wall Type WT-13 SE60-K-56(25) SPEEDLINE 60mm PI Shaf t Encasement wit h Knauf 15mm Fire Panel, Knauf 19mm Coreboard,25mm A PR 60 NA 4300 77 Severe

Wall Type WT-15 PW50-K-62 Twin SPEEDLINE 50mm C St ud Part it ion wit h 2x Knauf 15mm Fire Panel 120 NA 3400 M in 160 Severe

Wall Type WT-16 St air 1 & 2 WL507-K-52 SPEEDLINE Wall Lining Channel wit h Knauf 15mm Wallboard, NA NA NA NA NA

K10.125F Wall Type 17 IWL50-K-57 SPEEDLINE 50mm PI St ud Lining wit h 2x Knauf 12.5mm Wallboard, Inc V CL NA NA 2700 NA Severe

Wall Type WT-18 SE60-K-62 SPEEDLINE 60mm PI Shaf t Encasement wit h 2x Knauf 15mm Fire Panel, Knauf 19mm Coreboard, 120 41 4500 92 Severe

K10.145E Wall Type 19 WL507-B -51(25) SPEEDLINE Wall Lining Channel wit h Knauf 12.5mm Wallboard, 25mm APR NA NA NA NA NA

WLC50-K-59 Braced SPEEDLINE 50mm SPS C St ud Liner wit h2x Knauf 12.5mm Soundshield Plus NA NA 2400 M in 90 NA
Wall Type WT-20
Wall Type WT-21 WL507-K-57 SPEEDLINE Wall lining channel wit h 2x Knauf 12.5mm wallboard, V CL where required NA NA NA NA NA

Wall Type WT-22 DF-K-51 Direct f ix t o POD, Knauf 12.5mm Knauf Wallboard NA NA NA NA NA

M F-K-52 SPEEDLINE M F Ceiling wit h Knauf 15mm Wallboard, NA NA NA NA NA


Ceiling Type CLG-01
SE60-K-62(25)Lam Wall Type WT-18 wit h addional SPEEDLINE Wall Liner wit h 110mm Rockwool & 12.5mm Knauf wallboard 120 47 4500 145 Severe
WT-18 - Rainscreen upgrade

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 6 of 168
KS-0247-K - 26/09/2017 Rev L

Materials Schedule:
Project: SR 0247K - Imperial West Block F
Date of Issue: 26 July 2017
SPEEDLINEMAINCOMPONENTS SECONDARYCOMPONENTS ACCESSORIES BOARDS
SPS5050mmCStud SPT5252mmSTDTrack Plywood18mm Knauf15mmSoundshieldPlus
PI5050mmIStud SPEDT5252mmDeepTrack ASP19BSPEEDLINEServiceSupportPlate Knauf15mmWallboard
SWL507WallLinerStud SWL60PerimeterTrack FS24SPEEDLINEFlatBracingStrip70mm Knauf12.5mmSoundshieldPlus
PI6060mmIStud AWL03BGL2Brkt.75Leg PB24SPEEDLINEPartitionBrace Knauf12.5mmWallboard
SSMF550mmCeilingSection AWL04BGL9Brkt.125Leg SPEEDLINEAcousticPuttyPads Knauf19mmCoreBoard
PI9292mmIStud PT6262mmSTDTrack SPEEDLINEFireRatedAcousticSealant Knauf15mmFirePanel
SPS9292mmCStud PEDT6262mmDeepTrack SPEEDLINEJointFiller Knauf15mmPerformancePlus
ASB62BShaftwallClips SPEEDLINEReadymixJointCompound Knauf15mmMoisturePanel
SSMF6APerimeterChannel 25mmSPEEDLINEDrywallScrews
SSMF7PrimaryChannel 42mmSPEEDLINEDrywallScrews
AMF9BClips Insulation50mmAPR
SPT9494mmTrack Insulation25mmAPR
PEDT9494mmDeepTrack 38mmSPEEDLINEDrywallScrews

AdditionalItemsnotinselectionlist AdditionalItemsnotinselectionlist AdditionalItemsnotinselectionlist AdditionalItemsnotinselectionlist


11mmOSB3

*(RTO)="RolledToOrder"

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 7 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
PW50-K-60(50) - SPEEDLINE METAL STUD PARTITION

Type & Ref: K10.125A - Wall Type WT-01


Architects Drawing Ref: --

SPEEDLINE Reference: PW50-K-60(50)(200)

Performance Overview:
Fire Resistance (minutes): 120/120 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 62 RwdB (-3,-7) to achieve 45 DnT,w+Ctr
Maximum Height:- Calculated on limiting deflection L/240 at 200Pa
@ 600 mm Ctrs: 6200 mm
Nominal Width: Min 212 mm. (Excluding finishes).
Insulation Required: 50 mm APR.
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail: All as per the current SPEEDLINE Product Application Guide.
Head Tracks: Two parallel lines of SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in
the centre of the profile at 600 mm centres with suitable fixings.
Base Tracks: Two parallel lines of SPEEDLINE SPT52 U Track, secured to floor in the centre of the
profile, with suitable fixings.
Studs: The two frames are installed using SPEEDLINE SPS50 C Studs at 600 mm centres.
Friction fitted into tracks. (400 mm centres if to be tiled).
Stud Bracing: The two frames linked and braced to each other at 1200 mm centres, using short
lengths of SPEEDLINE PB24 partition brace.
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Plasterboard linings: 1.2 mm MD1 Security Mesh to one side for SBD.
Inner Layer: 15 mm Knauf Soundshield Plus attached to both sides of framing at 600 mm
maximum centres with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 15 mm Knauf Soundshield Plus attached to both sides of framing at 300 mm
maximum centres with 42 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 42 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on opposing partition faces.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 8 of 168
KS-0247-K - 26/09/2017 Rev L

Partition Data Sheet - System Reference: PW50-K-60(50)

Braced Twin Frame PS50 C Studs set at 600mm centres


Studs Braced at a maximum of 1200mm centres
52mm head & floor tracks
50mm APR
Both sides lined with a double layer of 15mm Knauf Soundshield Plus Plasterboard

Performance Overview
Fire Resistance BS 476 Part 22:1987 120/120 Minutes (Integrity / Insulation)
Max Height 6200mm at 600mm Ctrs
Partition grade BS 5234 Severe Duty
Overall Partition Width Min 200mm

Sound Insulation

Maximum height calculated on a Limiting Deflection L/240 @ Max Air Pressure 200pa

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 9 of 168
KS-0247-K - 26/09/2017 Rev L

Page 10 of 168
KS-0247-K - 26/09/2017 Rev L

Page 11 of 168
KS-0247-K - 26/09/2017 Rev L

Page 12 of 168
KS-0247-K - 26/09/2017 Rev L

Page 13 of 168
KS-0247-K - 26/09/2017 Rev L

Page 14 of 168
KS-0247-K - 26/09/2017 Rev L

Page 15 of 168
KS-0247-K - 26/09/2017 Rev L

Page 16 of 168
KS-0247-K - 26/09/2017 Rev L

Page 17 of 168
KS-0247-K - 26/09/2017 Rev L

Page 18 of 168
KS-0247-K - 26/09/2017 Rev L

Page 19 of 168
KS-0247-K - 26/09/2017 Rev L

Page 20 of 168
KS-0247-K - 26/09/2017 Rev L

Page 21 of 168
KS-0247-K - 26/09/2017 Rev L

Page 22 of 168
KS-0247-K - 26/09/2017 Rev L

Page 23 of 168
KS-0247-K - 26/09/2017 Rev L

Page 24 of 168
KS-0247-K - 26/09/2017 Rev L

Page 25 of 168
KS-0247-K - 26/09/2017 Rev L

Page 26 of 168
KS-0247-K - 26/09/2017 Rev L

Page 27 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
50-K-52(25) - SPEEDLINE METAL STUD PARTITION

Type & Ref: K10.125B Wall Type WT-02


Wall Type WT-02A APR Insulation Not required
Architects Drawing Ref: --

SPEEDLINE Reference: 50-K-52(25)

Performance Overview:
Fire Resistance (minutes): 30/30 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 41 RwdB
Maximum Height:- Calculated on limiting deflection L/240 at 200Pa
@ 600 mm Ctrs: 2800 mm
@ 400 mm Ctrs: 3100 mm
@ 300 mm Ctrs: 3200 mm
Nominal Width: 82 mm. (Excluding finishes).
Insulation Required: 25 mm APR. (NOT required on WT-02A)
Duty Rating: Heavy. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail: All as per the current SPEEDLINE Product Application Guide.
Head Tracks: SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE SPT52 U Track, secured to floor in the centre of the profile, with suitable
fixings.
Studs: SPEEDLINE SPS50 C Studs at 600 mm centres. Friction fitted into tracks.
(400 mm centres if to be tiled).
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Plasterboard linings:
Outer Layer: 15 mm Knauf Wallboard attached to both sides of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Moisture Panel attached to wet side of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on opposing partition faces.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm OSB3 for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 28 of 168
KS-0247-K - 26/09/2017 Rev L

Partition Data Sheet - System Reference: 50-K-52(25)

PS50 C Studs set at 600mm centres


52mm head & floor tracks
25mm APR
Both sides lined with a single layer of 15mm Knauf Standard Plasterboard

Performance Overview
Fire Resistance BS 476 Part 22:1987 30/30 Minutes (Integrity / Insulation)
Max Height 2.8 Metres @ 600mm Stud Centres.
Partition grade BS 5234 Heavy Duty

Sound Insulation

Maximum height calculated on a Limiting Deflection L/240 @ Max Air Pressure 200pa

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 29 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE SPS50 'C' Stud at nominal 600mm centres

25mm Glass Mineral Wool

15mm Knauf Standard Wallboard fixed with SPEEDLINE Drywall


Screws at 300mm centres (200mm centres at external angles). Ref to table
for fixing length.

CDR No: 871 SCALE: NTS DATE: 21/04/15


C Stud - Staggered Joint
Single Layer
Wall Type WT-02
Page 30 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

SPEEDLINE Track suitably fixed at 600mm Ctrs

SPEEDLINE Fire Rated Acoustic Sealant

CDR No: 201 SCALE: NTS DATE: 17/06/15


C STUD
BASE DETAIL
SINGLE LAYER
5012StIns
Page 31 of 168
KS-0247-K - 26/09/2017 Rev L

Page 32 of 168
KS-0247-K - 26/09/2017 Rev L

Page 33 of 168
KS-0247-K - 26/09/2017 Rev L

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

Insulation as per Specification

SPEEDLINE C Stud suitably fixed at 600mm Ctrs

SPEEDLINE Fire Rated Acoustic Sealant

CDR No: 204 SCALE: NTS DATE: 17/06/15


C STUD
WALL JUNCTION DETAIL
SINGLE LAYER
5012StIns
Page 34 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

Insulation as per specification

SPEEDLINE C Stud Suitable fixed at 600mm Ctrs

CDR No: 2D SCALE: NTS DATE: 17/06/15


C STUD
CORNER DETAIL
SINGLE LAYER
5012StIns
Page 35 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm Insulation as per specification
centres (200mm at external angles).
Refer to above table for fixing lengths

SPEEDLINE C Stud suitably fixed at 600mm Ctrs

CDR No: 202 SCALE: NTS DATE: 17/06/15


C STUD
T JUNCTION DETAIL
SINGLE LAYER
5012StIns
Page 36 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification with timber insert

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

Suitable Fixings into Floor x 4

100mm
Additional Stud 150mm away
from door frame stud

150mm
Insulation as per Specification

CDR No: 36D SCALE: NTS DATE: 17/06/15


C STUD
DOOR UP TO 25 Kgs
SINGLE LAYER
5012StIns
Page 37 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
50-K-56 - SPEEDLINE METAL STUD PARTITION

Type & Ref: Wall Type WT-03


Architects Drawing Ref: --

SPEEDLINE Reference: 50-K-56

Performance Overview:
Fire Resistance (minutes): 60/60 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Maximum Height:- Calculated on limiting deflection L/240 at 200Pa
@ 600 mm Ctrs: 2800 mm
@ 400 mm Ctrs: 3100 mm
@ 300 mm Ctrs: 3200 mm
Nominal Width: 82 mm. (Excluding finishes).
Insulation Required: NA.
Duty Rating: Heavy. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail: All as per the current SPEEDLINE Product Application Guide.
Head Tracks: SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE SPT52 U Track, secured to floor in the centre of the profile, with suitable
fixings.
Studs: SPEEDLINE SPS50 C Studs at 600 mm centres. Friction fitted into tracks.
(400 mm centres if to be tiled).
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Plasterboard linings:
Outer Layer: 15 mm Knauf Fire Panel attached to both sides of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 25 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on opposing partition faces.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 38 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE SPS50 'C' Stud at nominal 600mm centres

15mm British Gypsum Gyproc Fireline fixed with SPEEDLINE Drywall


Screws at 300mm centres (200mm centres at external angles). Ref to table
for fixing length.

CDR No: 50-B-56 SCALE: NTS DATE: 22/04/15


C Stud - Staggered Joint
Single Layer

Page 39 of 168
KS-0247-K - 26/09/2017 Rev L

Page 40 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

SPEEDLINE Track suitably fixed at 600mm Ctrs

SPEEDLINE Fire Rated Acoustic Sealant

CDR No: 178 SCALE: NTS DATE: 17/06/15


C STUD
BASE DETAIL
SINGLE LAYER
5012FR
Page 41 of 168
KS-0247-K - 26/09/2017 Rev L

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

SPEEDLINE C Stud suitably fixed at 600mm Ctrs

SPEEDLINE Fire Rated Acoustic Sealant

CDR No:187 SCALE: NTS DATE: 17/06/15


C STUD
WALL JUNCTION DETAIL
SINGLE LAYER
5012FR
Page 42 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

SPEEDLINE C Stud Suitable fixed at 600mm Ctrs

CDR No: 2A SCALE: NTS DATE: 17/06/15


C STUD
CORNER DETAIL
SINGLE LAYER
5012FR
Page 43 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification

One Layer of Gypsum Plasterboard fixed


with SPEEDLINE Drywall Screws at 300mm Insulation as per specification
centres (200mm at external angles).
Refer to above table for fixing lengths

SPEEDLINE C Stud suitably fixed at 600mm Ctrs

CDR No: 188A SCALE: NTS DATE: 17/06/15


C STUD
T JUNCTION DETAIL
SINGLE LAYER
5012FR
Page 44 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE C Stud as per specification with timber insert


One Layer of Gypsum Plasterboard fixed
with SPEEDLINE Drywall Screws at 300mm
centres (200mm at external angles).
Refer to above table for fixing lengths

Suitable Fixings into Floor x 4

100mm
Additional Stud 150mm away
from door frame stud

150mm

CDR No: 36 SCALE: NTS DATE: 17/06/15


C STUD
DOOR UP TO 25 Kgs
SINGLE LAYER
5012FR
Page 45 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
IWL92-K-62(25) - SPEEDLINE INDEPENDENT I STUD WALL LINER

Type & Ref: K10.125D Wall Type WT-04 To Plant Rooms


Architects Drawing Ref: --

SPEEDLINE Reference: IWL92-K-62(25)

Performance Overview:
Fire Resistance (minutes): 120 Mins (Integrity/Insulation) BS 476 Part 22: 1987(In conjunction with
background).
Sound Insulation: 65 DnT,w (In conjunction with background).
Maximum Height: 5400 mm Calculated on limiting deflection L/240 at 200Pa
Nominal Width: NA
Insulation Required: 25 mm APR.
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.
Background: Masonry.
Steel Framing Detail:
Head Tracks: SPEEDLINE SPEDT94 Deep Flange U Track, secured to soffit, in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE SPT94 U Track, secured to floor in the centre of the profile, with suitable
fixings.
Studs: SPEEDLINE PI92 (92 mm) I Studs at 600 mm centres. Friction fitted into tracks.
(400 mm centres if to be tiled).
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.

Plasterboard linings:
Inner Layer: 15 mm Knauf Fire Panel attached to inside of framing at 600 mm maximum centres
with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 15 mm Knauf Fire Panel attached to inside of framing at 300 mm maximum centres
with 42 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 46 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE 92mm I Studs at 600mm Ctrs

25mm Glass Mineral Wool

2x15mm Knauf Fire Panel fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No:872 SCALE: NTS DATE: 11/11/16


INDEPENDENT I STUD LINING
WALL TYPE WT-04

Page 47 of 168
KS-0247-K - 26/09/2017 Rev L

Page 48 of 168
KS-0247-K - 26/09/2017 Rev L

Page 49 of 168
KS-0247-K - 26/09/2017 Rev L

Page 50 of 168
KS-0247-K - 26/09/2017 Rev L

Page 51 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
WL507-K-54 SPEEDLINE WALL LINING

Type & Ref: K10.145A/B Wall Type WT-05


Architects Drawing Ref: --

SPEEDLINE Reference: WL507-K-54

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 45 Dntw in conjunction with background
Maximum Height: NA
Nominal Width: 20 -175 mm Dependent on bracket type used (background to face of channel).
Background: Concrete.

Steel Framing Detail:


Perimeter Track: SPEEDLINE SWL60 secured to perimeter of the room, in the centre of the profile at
600 mm maximum centres with suitable fixings
Wall Liner Section: Install row of SPEEDLINE SWL507 Wall Liner Section friction fitted into tracks at
600 mm centres
Stand Off: 20 -175 mm Dependent on bracket type used (background to face of channel).
Brackets: Fix brackets SPEEDLINE AWL03 (75 mm leg), AWL04 (125 mm leg) or AWL08
(175 mm leg), vertically at maximum 800 mm centres.

Plasterboard linings:
Outer Layer: 15 mm Knauf Soundshield Plus attached to inside of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 25 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 52 of 168
KS-0247-K - 26/09/2017 Rev L

Page 53 of 168
KS-0247-K - 26/09/2017 Rev L

Page 54 of 168
KS-0247-K - 26/09/2017 Rev L

Page 55 of 168
KS-0247-K - 26/09/2017 Rev L

Page 56 of 168
KS-0247-K - 26/09/2017 Rev L

Page 57 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
WL507-K-54 SPEEDLINE WALL LINING

Type & Ref: K10.145B Wall Type WT-05A


Architects Drawing Ref: --

SPEEDLINE Reference: WL507-K-54

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 45 Dntw in conjunction with background
Maximum Height: NA
Nominal Width: 20 -175 mm Dependent on bracket type used (background to face of channel).
Background: Concrete.

Steel Framing Detail:


Perimeter Track: SPEEDLINE SWL60 secured to perimeter of the room, in the centre of the profile at
600 mm maximum centres with suitable fixings
Wall Liner Section: Install row of SPEEDLINE SWL507 Wall Liner Section friction fitted into tracks at
600 mm centres
Stand Off: 20 -175 mm Dependent on bracket type used (background to face of channel).
Brackets: Fix brackets SPEEDLINE AWL03 (75 mm leg), AWL04 (125 mm leg) or AWL08
(175 mm leg), vertically at maximum 800 mm centres.

Plasterboard linings: VCL Layer to framing


Outer Layer: 15 mm Knauf Soundshield Plus attached to inside of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 25 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 58 of 168
KS-0247-K - 26/09/2017 Rev L

Page 59 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
IWL50-K-57(25) - SPEEDLINE INDEPENDENT I STUD WALL LINER

Type & Ref: K10.125E Wall Type WT-07


Architects Drawing Ref: --

SPEEDLINE Reference: IWL50-K-57(25)

Performance Overview:
Fire Resistance (minutes): 120 Mins (Integrity/Insulation) BS 476 Part 22: 1987 (In conjunction with
background).
Sound Insulation: 65 DnT,w (In conjunction with background)
Maximum Height: 2700 mm Calculated on limiting deflection L/240 at 200Pa
Nominal Width: NA
Insulation Required: 25 mm APR.
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.
Background: Concrete.
Steel Framing Detail:
Head Tracks: SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE SPT52 U Track, secured to floor in the centre of the profile, with suitable
fixings.
Studs: SPEEDLINE PI50 (50 mm) I Studs at 600 mm centres. Friction fitted into tracks.
(400 mm centres if to be tiled).
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.

Plasterboard linings:
Inner Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 600 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 300 mm maximum
centres with 38 mm SPEEDLINE Drywall Screws.
Humid areas: 12.5 mm Knauf Moisture Panel attached to wet side of framing at 300 mm
maximum centres with 38 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 60 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE 50mm I Studs at 600mm Ctrs

25mm Mineral Wool Insulation

2x12.5mm Knauf Wallboard fixed with SPEEDLINE Drywall Screws


at 300mm centres (200mm centres at external angles). Ref to table
for fixing length.

CDR No:873 SCALE: NTS DATE: 15/07/15


INDEPENDENT I STUD LINING
WALL TYPE WT-07

Page 61 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
IWL50-K-57 - SPEEDLINE INDEPENDENT I STUD WALL LINER

Type & Ref: K10.125F Wall Type WT-08


Architects Drawing Ref: --

SPEEDLINE Reference: IWL50-K-57

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Maximum Height: 2700 mm Calculated on limiting deflection L/240 at 200Pa
Nominal Width: NA
Insulation Required: To Be Confirmed by Architect.
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.
Background: Lindner Panel.
Steel Framing Detail:
Head Tracks: SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE SPT52 U Track, secured to floor in the centre of the profile, with suitable
fixings.
Studs: SPEEDLINE PI50 (50 mm) I Studs at 600 mm centres. Friction fitted into tracks.
(400 mm centres if to be tiled).
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.

Plasterboard linings:
Inner Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 600 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 300 mm maximum
centres with 38 mm SPEEDLINE Drywall Screws.
Humid areas: 12.5 mm Knauf Moisture Panel attached to wet side of framing at 300 mm
maximum centres with 38 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 62 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE 50mm I Studs at 600mm Ctrs

Slab Edge

20mm
2x12.5mm Knauf Wallboard fixed with SPEEDLINE Drywall Screws
at 300mm centres (200mm centres at external angles). Ref to table
for fixing length.

CDR No:874 SCALE: NTS DATE: 11/11/16


INDEPENDENT I STUD LINING
WALL TYPE WT-08

Page 63 of 168
KS-0247-K - 26/09/2017 Rev L

Page 64 of 168
KS-0247-K - 26/09/2017 Rev L

Page 65 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
SE60-K-62 SPEEDLINE SHAFTWALL ENCASEMENT

Type & Ref: K10.145E Wall Type WT-09


Architects Drawing Ref: --

SPEEDLINE Reference: SE60-K-62

Performance Overview:
Fire Resistance (minutes): 120/120 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 40 RwdB
Maximum Height: 4500 mm (Calculated on limiting deflection L/240 at 200Pa)
Nominal Width: 92 mm. (Excluding finishes).
Insulation Required: NA.
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail:


Head Tracks: SPEEDLINE PEDT62 Deep Flange U Track secured to ceiling in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE PT62 secured to the floor in the centre of the profile at 600 mm centres
with suitable fixings.
Studs: Install row of SPEEDLINE PI60 (60 mm) I studs friction fitted into tracks at 600 mm
centres.
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Partition Brace: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip is required behind all horizontal
join in the plasterboard.
Plasterboard linings:
Shaft Side: Single layer of Knauf 19 mm Coreboard cut 25 mm less than the overall height is
installed between the studs secured with SPEEDLINE ASB62B Shaft Encasement
Brackets, at 600 mm maximum centres.
Coreboard packers should be installed between studs and screw fixed to head track
with min three fixings. For deflection ensure min 5 mm overlap of Coreboard head
packer to Coreboard lining.
Horizontal joints in Coreboard layer should be covered with a 100 mm wide strip of
Coreboard, screw fixed, sealed with SPEELDINE Fire Rated Acoustic Sealant.
Inner Layer: 15 mm Knauf Fire Panel attached to framing at 600 mm maximum centres with
25 mm SPEEDLINE Drywall Screws.
Outer Layer: 15 mm Knauf Fire Panel attached to framing at 300 mm maximum centres with
42 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 42 mm SPEEDLINE Drywall Screws.
Boarding installation: The outer layer of plasterboard must be fixed with all joints staggered in relation to the inner
layer.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 66 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 67 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE PI60 'I' Stud at nominal 600mm centres

Denotes SPEEDLINE Fire Rated Acoustic Sealant SPEEDLINE ASB62 Clips at nominal 600mm centres

2x15mm Knauf Fire Panel fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 875 SCALE: NTS DATE: 11/11/16


SHAFTWALL PARTITION SYSTEM
TWO BOARD LAYERS - 60mm STUDS
WALL TYPE WT-09
Page 68 of 168
KS-0247-K - 26/09/2017 Rev L

2x Gypsum Fire Resistant Boards fixed with SPEEDLINE


Drywall Screws at 300mm centres (200mm centres at
external angles). Ref to table for fixing length.

SPEEDLINE PI 'I' Stud

SPEEDLINE ASB62 Shaftwall Fixing Bracket at 600mm Ctrs

SPEEDLINE Standard Track fixed to with suitable fixing

Denotes SPEEDLINE Fire Rated Acoustic Sealant

INSULATION REMOVED FOR CLARITY

CDR No: SCALE: NTS DATE: 09/11/15


SHAFT ENCASEMENT PARTITION SYSTEM - BASE DETAIL

Page 69 of 168
KS-0247-K - 26/09/2017 Rev L

Page 70 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Deep Flange U Track Fixed to wall with suitable fixing


SPEEDLINE PI 'I' Stud

Denotes SPEEDLINE Fire Rated Acoustic Sealant

SPEEDLINE ASB62 Shaftwall Fixing Bracket at 600mm Ctrs

2x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 70 SCALE: NTS DATE: 19/08/15


SHAFT ENCASEMENT PARTITION SYSTEM - START WALL
DETAIL
GENERAL LAYOUT
Page 71 of 168
KS-0247-K - 26/09/2017 Rev L

Denotes SPEEDLINE Fire Rated Acoustic Sealant

SPEEDLINE Tracks fixed together at


max 600mm Ctrs

2x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 72 SCALE: NTS DATE: 19/08/15


SHAFTWALL PARTITION SYSTEM - OUTSIDE CORNER
GENERAL LAYOUT

Page 72 of 168
KS-0247-K - 26/09/2017 Rev L

Coreboard fixed to outside of Track


Denotes SPEEDLINE Fire Rated Acoustic Sealant

SPEEDLINE Tracks fixed together at


max 600mm Ctrs

2x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 71 SCALE: NTS DATE: 19/08/15


SHAFTWALL PARTITION SYSTEM - INSIDE CORNER
GENERAL LAYOUT

Page 73 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE ASB62 Shaftwall Fixing Bracket at 600mm Ctrs

SPEEDLINE PI 'I' Stud

Denotes SPEEDLINE Fire Rated Acoustic Sealant

2x Gypsum Fire Resistant Boards fixed with SPEEDLINE


Drywall Screws at 300mm centres (200mm centres at
external angles). Ref to table for fixing length.

SPEEDLINE Track Fixed to I Stud with suitable fixing

CDR No: 74 SCALE: NTS DATE: 19/08/15


SHAFTWALL PARTITION SYSTEM - JUNCTION ROOM SIDE
GENERAL LAYOUT

Page 74 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Track Fixed to I Stud with suitable fixing

Denotes SPEEDLINE Fire Rated Acoustic Sealant


SPEEDLINE PI 'I' Stud

SPEEDLINE ASB62 Shaftwall Fixing Bracket at 600mm Ctrs

2x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 73 SCALE: NTS DATE: 19/08/15


SHAFTWALL PARTITION SYSTEM - JUNCTION SHAFT SIDE
GENERAL LAYOUT

Page 75 of 168
KS-0247-K - 26/09/2017 Rev L

Page 76 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE PI 'I' Stud

Denotes SPEEDLINE Fire Rated Acoustic Sealant SPEEDLINE Deep Track Around Door Frame

Coreboard within I Stud

Timber Fillet within I Stud

2x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.
INSULATION NOT SHOWN FOR CLARITY

CDR No: 43 SCALE: NTS DATE: 07/07/15


SHAFTWALL PARTITION SYSTEM - DOOR FRAME
GENERAL LAYOUT

Page 77 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
WL507-K-57(25)Mod SPEEDLINE WALL LINING

Type & Ref: Wall Type WT-12


Architects Drawing Ref: --

SPEEDLINE Reference: WL507-K-57(25)Mod

Performance Overview:
Fire Resistance (minutes): 240 Mins (Integrity/Insulation) BS 476 Part 22: 1987(In conjunction with
background).
Sound Insulation: 65 DnT,w (In conjunction with background).
Maximum Height: NA
Nominal Width: 20 -175 mm Dependent on bracket type used (background to face of channel).
Background: WT-11 - Masonry
Insulation: 25 mm APR within channels
Duty Rating: Severe.

Steel Framing Detail:


Perimeter Track: SPEEDLINE SWL60 secured to perimeter of the room, in the centre of the profile at
600 mm maximum centres with suitable fixings
Wall Liner Section: Install row of SPEEDLINE SWL507 Wall Liner Section friction fitted into tracks at
600 mm centres
Stand Off: 20 -175 mm Dependent on bracket type used (background to face of channel).
Brackets: Fix brackets SPEEDLINE AWL03 (75 mm leg), AWL04 (125 mm leg) or AWL08
(175 mm leg), vertically at maximum 800 mm centres.

Plasterboard linings:
Inner Layer: 92.5mm SPEEDLINE PIR Thermal Laminate attached to inside of framing at 300 mm
maximum centres with suitable SPEEDLINE Drywall Screws.
Outer Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 300 mm maximum
centres with suitable SPEEDLINE Drywall Screws.
Humid areas: 12.5 mm Knauf Moisture Panel attached to wet side of framing at 300 mm
maximum centres with suitable screws
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 78 of 168
KS-0247-K - 26/09/2017 Rev L

Page 79 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
SE60-K-56(25) SPEEDLINE SHAFTWALL ENCASEMENT

Type & Ref: K10.155 Wall Type WT-13


Architects Drawing Ref: --

SPEEDLINE Reference: SE60-K-56(25)

Performance Overview:
Fire Resistance (minutes): 60/60 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 42 RwdB Estimated
Maximum Height: 4300 mm (Calculated on limiting deflection L/240 at 200Pa)
Nominal Width: 77 mm. (Excluding finishes).
Insulation Required: 25 mm APR
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.
Steel Framing Detail:
Head Tracks: SPEEDLINE PEDT62 Deep Flange U Track secured to ceiling in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE PT62 secured to the floor in the centre of the profile at 600 mm centres
with suitable fixings.
Studs: Install row of SPEEDLINE PI60 (60 mm) I studs friction fitted into tracks at 600 mm
centres.
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Partition Brace: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip is required behind all horizontal
join in the plasterboard.
Plasterboard linings:
Shaft Side: Single layer of Knauf 19 mm Coreboard cut 25 mm less than the overall height is
installed between the studs secured with SPEEDLINE ASB62B Shaft Encasement
Brackets, at 600 mm maximum centres.
Coreboard packers should be installed between studs and screw fixed to head track
with min three fixings. For deflection ensure min 5 mm overlap of Coreboard head
packer to Coreboard lining.
Horizontal joints in Coreboard layer should be covered with a 100 mm wide strip of
Coreboard, screw fixed, sealed with SPEELDINE Fire Rated Acoustic Sealant.
Outer Layer: 15 mm Knauf Fire Panel attached to framing at 300 mm maximum centres with
25 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 25 mm SPEEDLINE Drywall Screws.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 80 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE PI60 'I' Stud at nominal 600mm centres

Denotes SPEEDLINE Fire Rated Acoustic Sealant SPEEDLINE ASB62 Clips at nominal 600mm centres

25mm Glass Mineral Wool 15mm Knauf Fire Panel fixed with SPEEDLINE Drywall Screws at 300mm
centres (200mm centres at external angles). Ref to table for fixing length.

CDR No: SE60-K-56(25) SCALE: NTS DATE: 13/10/15


SHAFTWALL PARTITION SYSTEM
TWO BOARD LAYERS - 60mm STUDS

Page 81 of 168
KS-0247-K - 26/09/2017 Rev L

Page 82 of 168
KS-0247-K - 26/09/2017 Rev L

Page 83 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Deep Flange U Track Fixed to wall with suitable fixing

SPEEDLINE PI 'I' Stud


Denotes SPEEDLINE Fire Rated Acoustic Sealant

INSULATION REMOVED FOR CLARITY

SPEEDLINE ASB62 Shaftwall Fixing Bracket at 600mm Ctrs

1x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 383c SCALE: NTS DATE: 19/08/15


SHAFT ENCASEMENT PARTITION SYSTEM - START WALL
DETAIL
GENERAL LAYOUT
Page 84 of 168
KS-0247-K - 26/09/2017 Rev L

Coreboard fixed to outside of Track


Denotes SPEEDLINE Fire Rated Acoustic Sealant

INSULATION REMOVED FOR CLARITY

SPEEDLINE Tracks fixed together at


max 600mm Ctrs

1x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 383a SCALE: NTS DATE: 19/08/15


SHAFTWALL PARTITION SYSTEM - INSIDE CORNER
GENERAL LAYOUT

Page 85 of 168
KS-0247-K - 26/09/2017 Rev L

Denotes SPEEDLINE Fire Rated Acoustic Sealant

SPEEDLINE Tracks fixed together at


max 600mm Ctrs

INSULATION REMOVED FOR CLARITY

1x Gypsum Fire Resistant Boards fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 383b SCALE: NTS DATE: 16/05/16


SHAFTWALL PARTITION SYSTEM - OUTSIDE CORNER
GENERAL LAYOUT

Page 86 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
PW50-K-62 - SPEEDLINE METAL STUD PARTITION

Type & Ref: Wall Type WT-15


Architects Drawing Ref: --

SPEEDLINE Reference: PW50-K-62

Performance Overview:
Fire Resistance (minutes): 120/120 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA.
Maximum Height:- Calculated on limiting deflection L/240 at 200Pa
@ 600 mm Ctrs: 3400 mm
Nominal Width: Min 160 mm. (Excluding finishes).
Insulation Required: NA.
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail: All as per the current SPEEDLINE Product Application Guide.
Head Tracks: Two parallel lines of SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in
the centre of the profile at 600 mm centres with suitable fixings.
Base Tracks: Two parallel lines of SPEEDLINE SPT52 U Track, secured to floor in the centre of the
profile, with suitable fixings.
Studs: The two frames are installed using SPEEDLINE SPS50 C Studs at 600 mm centres.
Friction fitted into tracks. (400 mm centres if to be tiled).
Stud Bracing: The two frames linked and braced to each other at 1200 mm centres, using short
lengths of SPEEDLINE PB24 partition brace.
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Plasterboard linings:
Inner Layer: 15 mm Knauf Fire Panel attached to both sides of framing at 600 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 15 mm Knauf Fire Panel attached to both sides of framing at 300 mm maximum
centres with 42 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 42 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on opposing partition faces.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 87 of 168
KS-0247-K - 26/09/2017 Rev L

TWIN SPEEDLINE SPS50 'C' Stud at nominal 600mm centres


Braced together with SPEEDLINE PB24 Partition Brace at 1200mm
vertical centres (First Brace - 1200mm from Floor)

Min 160mm

2 layers of 15mm Knauf Fire Panel fixed with SPEEDLINE Drywall Screws at
300mm centres (200mm centres at external angles). Ref to table for fixing
length.

CDR No: 877 SCALE: NTS DATE: 11/05/15


TWIN FRAME BRACED C Stud - Staggered Joint
Double Layer
WALL TYPE WT-15
Page 88 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
WL507-K-52 SPEEDLINE WALL LINING

Type & Ref: Wall Type WT-16 Stair 1 & 2


Architects Drawing Ref: --

SPEEDLINE Reference: WL507-K-52

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Maximum Height: NA
Nominal Width: 20 -175 mm Dependent on bracket type used (background to face of channel).
Background: Masonry

Steel Framing Detail:


Perimeter Track: SPEEDLINE SWL60 secured to perimeter of the room, in the centre of the profile at
600 mm maximum centres with suitable fixings
Wall Liner Section: Install row of SPEEDLINE SWL507 Wall Liner Section friction fitted into tracks at
600 mm centres
Stand Off: 20 -175 mm Dependent on bracket type used (background to face of channel).
Brackets: Fix brackets SPEEDLINE AWL03 (75 mm leg), AWL04 (125 mm leg) or AWL08
(175 mm leg), vertically at maximum 800 mm centres.

Plasterboard linings:
Outer Layer: 15 mm Knauf Wallboard attached to inside of framing at 300 mm maximum centres
with 25 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Moisture Panel attached to wet side of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 89 of 168
KS-0247-K - 26/09/2017 Rev L

Page 90 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
IWL50-K-57 - SPEEDLINE INDEPENDENT I STUD WALL LINER

Type & Ref: K10.125F Wall Type 17 Levels 9/18 & 27


Architects Drawing Ref: --

SPEEDLINE Reference: IWL50-K-57

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Maximum Height: 2700 mm Calculated on limiting deflection L/240 at 200Pa
Nominal Width: NA
Insulation Required: To Be Confirmed by Architect.
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail:


Head Tracks: SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE SPT52 U Track, secured to floor in the centre of the profile, with suitable
fixings.
Studs: SPEEDLINE PI50 (50 mm) I Studs at 600 mm centres. Friction fitted into tracks.
(400 mm centres if to be tiled).
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.

Plasterboard linings: VCL Layer to studs as required.


Inner Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 600 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 300 mm maximum
centres with 38 mm SPEEDLINE Drywall Screws.
Humid areas: 12.5 mm Knauf Moisture Panel attached to wet side of framing at 300 mm
maximum centres with 38 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 91 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE 50mm I Studs at 600mm Ctrs

VCL

2x12.5mm Knauf Wallboard fixed with SPEEDLINE Drywall Screws


at 300mm centres (200mm centres at external angles). Ref to table
for fixing length.

CDR No:879 SCALE: NTS DATE: 11/11/16


INDEPENDENT I STUD LINING
WALL TYPE WT-17

Page 92 of 168
KS-0247-K - 26/09/2017 Rev L

Page 93 of 168
KS-0247-K - 26/09/2017 Rev L

Page 94 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
SE60-K-62 SPEEDLINE SHAFTWALL ENCASEMENT

Type & Ref: Wall Type WT-18


Architects Drawing Ref: --

SPEEDLINE Reference: SE60-K-62

Performance Overview:
Fire Resistance (minutes): 120/120 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 41 RwdB
Maximum Height: 4500 mm (Calculated on limiting deflection L/240 at 200Pa)
Nominal Width: 92 mm. (Excluding finishes).
Insulation Required: NA
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail:


Head Tracks: SPEEDLINE PEDT62 Deep Flange U Track secured to ceiling in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE PT62 secured to the floor in the centre of the profile at 600 mm centres
with suitable fixings.
Studs: Install row of SPEEDLINE PI60 (60 mm) I studs friction fitted into tracks at 600 mm
centres.
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Partition Brace: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip is required behind all horizontal
join in the plasterboard.
Plasterboard linings:
Shaft Side: Single layer of Knauf 19 mm Coreboard cut 25 mm less than the overall height is
installed between the studs secured with SPEEDLINE ASB62B Shaft Encasement
Brackets, at 600 mm maximum centres.
Coreboard packers should be installed between studs and screw fixed to head track
with min three fixings. For deflection ensure min 5 mm overlap of Coreboard head
packer to Coreboard lining.
Horizontal joints in Coreboard layer should be covered with a 100 mm wide strip of
Coreboard, screw fixed, sealed with SPEELDINE Fire Rated Acoustic Sealant.
Inner Layer: 15 mm Knauf Fire Panel attached to framing at 600 mm maximum centres with
25 mm SPEEDLINE Drywall Screws.
Outer Layer: 15 mm Knauf Fire Panel attached to framing at 300 mm maximum centres with
42 mm SPEEDLINE Drywall Screws.
Humid areas: 15 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 42 mm SPEEDLINE Drywall Screws.
Boarding installation: The outer layer of plasterboard must be fixed with all joints staggered in relation to the inner
layer.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 95 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 96 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE PI60 'I' Stud at nominal 600mm centres

Denotes SPEEDLINE Fire Rated Acoustic Sealant SPEEDLINE ASB62 Clips at nominal 600mm centres

2x15mm Knauf Fire Panel fixed with SPEEDLINE Drywall Screws at


300mm centres (200mm centres at external angles). Ref to table for
fixing length.

CDR No: 880 SCALE: NTS DATE: 22/09/15


SHAFTWALL PARTITION SYSTEM
TWO BOARD LAYERS - 60mm STUDS
WALL TYPE WT-18
Page 97 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
WL507-B-51(25) SPEEDLINE WALL LINING

Type & Ref: K10.145E Wall Type 19


Architects Drawing Ref: --

SPEEDLINE Reference: WL507-B-51(25)

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Maximum Height: NA
Nominal Width: 20 -175 mm Dependent on bracket type used (background to face of channel).
Insulation: 25 mm APR
Background: Masonry

Steel Framing Detail:


Perimeter Track: SPEEDLINE SWL60 secured to perimeter of the room, in the centre of the profile at
600 mm maximum centres with suitable fixings
Wall Liner Section: Install row of SPEEDLINE SWL507 Wall Liner Section friction fitted into tracks at
600 mm centres
Stand Off: 20 -175 mm Dependent on bracket type used (background to face of channel).
Brackets: Suitably fix brackets SPEEDLINE AWL03 (75 mm leg), AWL04 (125 mm leg) or
AWL08 (175 mm leg), vertically at maximum 800 mm centres. Secure brackets to
Wall Liner Section using SPEEDLINE Wafer Head Drywall Screws, one fixing to each
side of bracket. Fold back excess bracket to provide flush finish for board lining.

Plasterboard linings: VCL where required.


Outer Layer: 12.5 mm British Gypsum Gyproc Wallboard attached to inside of framing at
300 mm maximum centres with 25 mm SPEEDLINE Drywall Screws.
Humid areas: 12.5 mm Knauf Moisture Panel attached to wet side of framing at 300 mm
maximum centres with 25 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 98 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Fixing Bracket at 800mm centres


AWL03B = 75mm Leg
AWL04B = 125mm Leg
AWL08B = 175mm Leg

SPEEDLINE Drywall Screws


Length=Laminate thickness Plus 10mm

12.5mm Knauf Wallboard

25mm Insulation if Specified

SPEEDLINE WL507 Wall Liner at 600mm centres

SPEEDLINE WL60 Perimeter Track Fixed to Floor


at 600mm centres with suitable fixing

SPEEDLINE Fire Rated Acoustic Sealant

CDR No: SCALE: NTS DATE: 05/08/15


WALL LINING SYSTEM - WL507-K-51(25)

Page 99 of 168
KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
WLC50-K-59- SPEEDLINE BRACED C STUD WALL LINER

Type & Ref: Wall Type WT-20


Architects Drawing Ref: --

SPEEDLINE Reference: WLC50-K-59

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Maximum Height: 2400 mm Calculated on limiting deflection L/240 at 200Pa (Braced)
Nominal Width: Min 90 mm. (Excluding finishes).
Insulation Required: NA.
Duty Rating: NA. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail:


Head Tracks: SPEEDLINE SPEDT52 Deep Flange U Track, secured to soffit, in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE SPT52 U Track, secured to floor in the centre of the profile, with suitable
fixings.
Studs: SPEEDLINE SPS50 C Studs at 600 mm centres. Friction fitted into tracks.
(400 mm centres if to be tiled).
Bracing: Studs Braced to structure at 1200 mm centres.
SPEEDLINE PB24 Partition Brace or offcuts of stud or Track. Fixed to substrate.
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.

Plasterboard linings:
Inner Layer: 12.5 mm Knauf Soundshield Plus attached to inside of framing at 600 mm
maximum centres with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 12.5 mm Knauf Soundshield Plus attached to inside of framing at 300 mm
maximum centres with 38mm SPEEDLINE Drywall Screws.
Humid areas: 12.5 mm Knauf Performance Plus attached to wet sides of framing at 300 mm
maximum centres with 38 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 100 of 168


KS-0247-K - 26/09/2017 Rev L

Page 101 of 168


KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
WL507-K-57 SPEEDLINE WALL LINING

Type & Ref: Wall Type WT-21


Architects Drawing Ref: --

SPEEDLINE Reference: WL507-K-57

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Maximum Height: NA
Nominal Width: 20 -175 mm Dependent on bracket type used (background to face of channel).
Background: Masonry

Steel Framing Detail:


Perimeter Track: SPEEDLINE SWL60 secured to perimeter of the room, in the centre of the profile at
600 mm maximum centres with suitable fixings
Wall Liner Section: Install row of SPEEDLINE SWL507 Wall Liner Section friction fitted into tracks at
600 mm centres
Stand Off: 20 -175 mm Dependent on bracket type used (background to face of channel).
Brackets: Fix brackets SPEEDLINE AWL03 (75 mm leg), AWL04 (125 mm leg) or AWL08
(175 mm leg), vertically at maximum 800 mm centres.

Plasterboard linings: VCL Where required.


Inner Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.
Outer Layer: 12.5 mm Knauf Wallboard attached to inside of framing at 300 mm maximum
centres with 38mm SPEEDLINE Drywall Screws.
Humid areas: 12.5 mm Knauf Moisture Panel attached to wet side of framing at 300 mm
maximum centres with 38 mm SPEEDLINE Drywall Screws.
Boarding installation: All plasterboard joints to be staggered on between layers.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 102 of 168


KS-0247-K - 26/09/2017 Rev L

Page 103 of 168


KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
DF-K-51 SPEEDLINE WALL DIRECT FIX BOARD LINING

Type & Ref: Wall Type WT-22


Architects Drawing Ref: --

SPEEDLINE Reference: DF-K-51

Performance Overview:
Fire Resistance (minutes): NA
Sound Insulation: NA RwdB
Maximum Height: NA
Nominal Width: NA
Duty Rating: NA.
Background: POD Frame

Installation Requirements: SPEEDLINE Drywall Screws to suit background

Plasterboard linings:
Outer Layer: 12.5 mm Knauf Wallboard Direct fixed to substrate with suitable fixings
Humid areas: Moisture Resistant Plasterboard of specified type to be used in areas of high
humidity.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: Pre-treat all concrete backgrounds with proprietary bonding agent, to be applied in
bands to correspond with adhesive dab centres.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 104 of 168


KS-0247-K - 26/09/2017 Rev L

Page 105 of 168


KS-0247-K - 26/09/2017 Rev L

Page 106 of 168


KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
MF-K-52 - SPEEDLINE METAL FRAME CEILING

Type & Ref: Ceiling Type CLG-01


Architects Drawing Ref: --

SPEEDLINE Reference: MF-K-52

Performance Overview:
Fire Resistance (minutes): NA (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: NA RwdB
Insulation Required: NA
Maximum Load: Up to 30 kg/m2
Structural Soffit: Concrete.

Steel Framing Detail: All as per the current SPEEDLINE Product Application Guide.
Perimeter Tracks: SPEEDLINE SSMF6A secured to perimeter of the room, in the centre of the profile at
600 mm maximum centres with suitable fixings
Primary Channel: SPEEDLINE SSMF7 spaced at 1200 mm centres supported from the ceiling structure
using rigid angle SLO6 at 1200 mm centres with soffit cleat attached. Secure using
suitable fixings.
Furring Section: SPEEDLINE SSMF5 spaced at 400 mm or 450 mm centres and secured to the
Primary Channels using two self-drilling drywall pan head screws per connection or
AMF9B pre formed connecting clips*.
* * AMF9B pre formed connecting clips must only be used in commercial applications.
For all domestic situations self-drilling drywall pan head screws must be used.

Plasterboard linings:
Outer Layer: 15 mm Knauf Wallboard attached to underside of framing at 230 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws. The perimeter of the room and ends
of boards to be fixed at 150 mm maximum centres.
Humid areas: 15 mm Knauf Moisture Panel attached to wet side of framing at 300 mm maximum
centres with 25 mm SPEEDLINE Drywall Screws.

Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 107 of 168


KS-0247-K - 26/09/2017 Rev L

SPEEDLINE AMF12B Angle Fixing Bracket


suitable fixed to soffit

SPEEDLINE SL06 25x25mm Angle at max


1200mm Ctrs, fixed to SMF7 Primary Channel
with 2 No SPEEDLINE Self Drilling Wafer
Head Screws

SPEEDLINE SMF7 Primary Channel at


1200mm max Ctrs

SPEEDLINE SMF5 Ceiling Channel at nominal


450mm Ctrs. Fixed with 2No Self Drilling Wafer
Head Screws

15mm Knauf Wallboard fixed with SPEEDLINE Drywall Screws at


230mm centres (150mm centres at cut edges). Ref to table for fixing
length.

CDR No: 875 SCALE: NTS DATE: 16/07/15


MF 1x15mm KNAUF WALLBOARD (Screws)
TO SOFFIT AS PER SPECIFICATION
CEILING TYPE CLG-01
Page 108 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Metal Angle Hangers

SPEEDLINE SMF7 Primary Channel

SPEEDLINE SMF6a Edge Channel SPEEDLINE SMF5 Ceiling Channel


fixed at Max 600mm Ctrs to wall

Additional SPEEDLINE SMF7


Primary Channel to support
frame

Frame screw fixed to


edges of SMF5 & SMF7
Channels to brace MF
Grid

ax
mmM
12 450
00
m
m
M Frame to support Access Panel created with
ax
SPEEDLINE SMF6a Edge Channel

CDR No: 60 SCALE: NTS DATE: 03/05/16


MF CEILING SYSTEM
ACCESS PANEL OPENING

Page 109 of 168


KS-0247-K - 26/09/2017 Rev L

Page 110 of 168


KS-0247-K - 26/09/2017 Rev L

150mm Max

150mm Max
SPEEDLINE SL06 25x25mm Angle at max
1200mm Ctrs, fixed to SMF7 Primary Channel
with 2 No SPEEDLINE Self Drilling Wafer
Head Screws

SPEEDLINE SMF7 Primary Channel at


1200mm max Ctrs or as per specication

SPEEDLINE SMF5 Ceiling Channel at nominal


2 x SPEEDLINE SMF6A Edge channel 450mm Ctrs. Fixed with 2No Self Drilling Wafer
fixed at 600mm Ctrs Head Screws

Gypsum Plasterboard fixed with SPEEDLINE Drywall Screws at


230mm centres (150mm centres at cut edges). Ref to table for fixing
length.

CDR No: 59 SCALE: NTS DATE: 18/08/15


MF - BULKHEAD LEVEL CHANGE DETAIL

Page 111 of 168


KS-0247-K - 26/09/2017 Rev L

Page 112 of 168


KS-0247-K - 26/09/2017 Rev L

Page 113 of 168


KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
SE60-K-62(25)Lam SPEEDLINE SHAFTWALL ENCASEMENT

Type & Ref: WT-18 - Rainscreen upgrade


Architects Drawing Ref: --

SPEEDLINE Reference: SE60-K-62(25)Lam

Performance Overview:
Fire Resistance (minutes): 120/120 (Integrity/Insulation) BS 476 Part 22: 1987
Sound Insulation: 47 RwdB
Maximum Height: 4500 mm (Calculated on limiting deflection L/240 at 200Pa)
Nominal Width: 145 mm. (Excluding finishes).
Insulation Required: 25 mm APR
Duty Rating: Severe. BS 5234:Part 2: (Annexes A-F)
Deflection Required: 15 mm to be confirmed by Structural Engineer.

Steel Framing Detail:


Head Tracks: SPEEDLINE PEDT62 Deep Flange U Track secured to ceiling in the centre of the
profile at 600 mm centres with suitable fixings.
Base Tracks: SPEEDLINE PT62 secured to the floor in the centre of the profile at 600 mm centres
with suitable fixings.
Studs: Install row of SPEEDLINE PI60 (60 mm) I studs friction fitted into tracks at 600 mm
centres.
Deflection Head: If Structural deflection is deemed necessary, please refer to SPEEDLINE Product
Application Guide for detail.
Partition Brace: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip is required behind all horizontal
join in the plasterboard.
Plasterboard linings:
Shaft Side: Single layer of Knauf 19 mm Coreboard cut 25 mm less than the overall height is
installed between the studs secured with SPEEDLINE ASB62B Shaft Encasement
Brackets, at 600 mm maximum centres.
Coreboard packers should be installed between studs and screw fixed to head track
with min three fixings. For deflection ensure min 5 mm overlap of Coreboard head
packer to Coreboard lining.
Horizontal joints in Coreboard layer should be covered with a 100 mm wide strip of
Coreboard, screw fixed, sealed with SPEELDINE Fire Rated Acoustic Sealant.
Inner Layer: 15 mm Knauf Fire Panel attached to framing at 600 mm maximum centres with
25 mm SPEEDLINE Drywall Screws.
Outer Layer: 15 mm Knauf Fire Panel attached to framing at 300 mm maximum centres with
42 mm SPEEDLINE Drywall Screws.
Inside Thermal Layer: 110 mm Rockwool between SPEEDLINE Wall lining system with 12.5 mm Knauf
Wallboard outer
Boarding installation: The outer layer of plasterboard must be fixed with all joints staggered in relation to the inner
layer.
Horizontal board joints: SPEEDLINE PB24 Partition Brace or FS24 Flat Strip required behind all horizontal
board joints.
Finishes: Skim plaster or taped & jointed (MR Boards to be taped & jointed only).
Acoustic Seal: At junctions between partitions and any other air paths, apply a continuous bead of
SPEEDLINE Fire Rated Acoustic Sealant, to clean dust free surfaces.
Accessories: SPEEDLINE Service Support plate & 18 mm Plywood for all patresses.
SPEEDLINE Putty Pads to Electrical sockets boxes.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 114 of 168


KS-0247-K - 26/09/2017 Rev L

PROJECT - Imperial West Block F


London
General Notes: To be installed in accordance with SPEEDLINE recommendations and British
Standards BS 8212:1995 & BS 8000:Part 8:1994.
This document should be read in conjunction with clauses specified in original
contract documentation.
Flanking details to be appropriate to current requirements.

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 115 of 168


KS-0247-K - 26/09/2017 Rev L

Page 116 of 168


KS-0247-K - 26/09/2017 Rev L

Partition Data Sheet - System Reference: SE60-K-62(25)(Shaft Encasement)

PI60 I Studs set at 600mm centres


62mm head & floor tracks
25mm APR
Shaft side (in between I Studs) lined with 19mm Knauf Coreboard
Landing side lined with 2 x 15mm Knauf Fire Panel Plasterboard

Performance Overview
Fire Resistance BS 476 Part 22:1987 120/120 Minutes (Integrity / Insulation)
Max Height Refer to Specification Clause.
Partition grade BS 5234 Severe Duty

Sound Insulation

Estimated at 47 RwdB

Maximum height calculated on a Limiting Deflection L/240 @ Max Air Pressure 200pa

SPEEDLINE Drywall Products, Hillsborough Works, Langsett Road, Sheffield, S6 2LW.


Tel: 0114 231 8030. Fax: 0114 231 8031
Email: enquiries@speedlinedrywall.co.uk

Page 117 of 168


KS-0247-K - 26/09/2017 Rev L

SIG 360 Technical Centre


T1 Trafford Point
Twining Road
Off Ashburton Road West
Manchester
M17 1SH

Project Information
Reference Shaftwall to 0.25 U vlaue
Date 11 July 2017
Project SIG360 16-0466 LoR Imperial West Block F
Construction Type
Element : Wall - Uvalue Element 1
Internal surface emissivity : High External surface emissivity : High
Thickness Thermal Thermal Pitch Bridge details
Conductivity Resistance () Air gaps
(mm) (W/mK) (mK/W) (Level, Delta U")
Outside surface resistance - - 0.040
Gyproc CoreBoard 19.0 - 0.080 0.300% Shaftwall
(19.0mm)
Airspace, heat flow horizontal, 12.5 mm thick 12.5 - 0.150 0.300% Shaftwall
(12.5mm)
Isowool Acoustic Partition Roll (APR) 25.0 - 0.680 0.300% Shaftwall
(25.0mm)
L:0 0.000W/mK
Airspace, heat flow horizontal, 12.5 mm thick 12.5 - 0.150 0.300% Shaftwall
(12.5mm)
Gyproc Fireline 15.0 - 0.060
Gyproc Fireline 15.0 - 0.060
Rockwool RWA45 Slab (Laminated to 12.5mm 110.0 0.035 3.143 L:0 0.000W/mK
plasterboard)
Standard Plasterboard (Laminated to RWA45) 12.5 0.210 0.060 L:0 0.000W/mK
Inside surface resistance - - 0.130
Total thickness 221.5mm
U-value = 0.25 W/mK
U-value, Combined Method : 0.248 W/mK (upper/lower limit 4.549 / 3.783mK/W, dUf 0.0084, dUg 0.0000, dUp0.0000, dUr0.0000,
dUrc1 0.0000, dUrc2 0.0000)
Correction factors
Mechanical fasteners :-
Fixing of the laminate
Alpha : 0.80 per m lambda f : 17.0000W/mK nf : 5.000 per m Af : 28.300mm Recess : 0.0mm
Delta Uf for Rockwool RWA45 Slab (Laminated to 12.5mm plasterboard) : 0.0083
Fixing of the laminate
Alpha : 0.80 per m lambda f : 17.0000W/mK nf : 5.000 per m Af : 28.300mm Recess : 0.0mm
Delta Uf for Standard Plasterboard (Laminated to RWA45) : 0.0000
nf = fasteners per m Af = fasteners cross-sectional area
Air gaps, Delta Ug = 0.000W/mK
(Based on the combined method for determining U-values of structures containing repeating thermal bridges)

Page 1 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jul 2017
Licensed to Sheffield Insulations Limited
C:\Users\mstearne2\Documents\Chris Fitzpatrick\SIG360 16-0466 LoR Imperial West Block F\Shaftwall to 0.25 U vlaue.JDP Shaftwall to 0.25 U vlaue
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 118 of 168


KS-0247-K - 26/09/2017 Rev L
Thickness Thermal Thermal Vapour Vapour
Conductivity Resistance Resistivity Resistance
(mm) (W/mK) (mK/W) (MNs/gm) (MNs/g)
Outside surface resistance - - 0.040 - -
Gyproc CoreBoard 19.0 - 0.080 - 0.95
Airspace, heat flow horizontal, 12.5 mm thick 12.5 - 0.150 - 0.00
Isowool Acoustic Partition Roll (APR) 25.0 - 0.680 - 0.13
Airspace, heat flow horizontal, 12.5 mm thick 12.5 - 0.150 - 0.00
Gyproc Fireline 15.0 - 0.060 - 0.75
Gyproc Fireline 15.0 - 0.060 - 0.75
Rockwool RWA45 Slab (Laminated to 12.5mm 110.0 0.035 3.143 5.90 0.65
plasterboard)
Standard Plasterboard (Laminated to RWA45) 12.5 0.210 0.060 400.00 5.00
Inside surface resistance - - 0.130 - -
Total thickness 221.5mm

Page 2 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jul 2017
Licensed to Sheffield Insulations Limited
C:\Users\mstearne2\Documents\Chris Fitzpatrick\SIG360 16-0466 LoR Imperial West Block F\Shaftwall to 0.25 U vlaue.JDP Shaftwall to 0.25 U vlaue
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 119 of 168


KS-0247-K - 26/09/2017 Rev L

Structure element : Wall


Condensation calculations performed in accordance with BS5250:2011

Condensation is occuring at the following layers interfaces:-

Month Int Int Ext Ext


(C) (%RH) (C) (%RH)

Jan 20.00 58.20 3.50 86.00


Feb 20.00 57.20 3.80 82.50
Mar 20.00 57.30 5.70 80.00
Apr 20.00 57.80 8.00 77.00
May 20.00 61.60 11.30 77.00
Jun 20.00 66.10 14.40 76.00
Jul 20.00 71.00 16.50 76.50
Aug 20.00 71.60 16.10 78.50
Sep 20.00 68.70 13.80 81.50
Oct 20.00 64.60 10.70 84.00
Nov 20.00 60.10 6.40 85.50
Dec 20.00 59.00 4.50 86.50

Gc = Monthly moisture accumulation per area at an interface


Ma = Accumulated moisture content per area at an interface

Peak accumulated moisture content per area at interface (Ma) = 0.00000 Kg/m

Annual moisture accumulation = 0.00000 Kg/m

Page 3 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jul 2017
Licensed to Sheffield Insulations Limited
C:\Users\mstearne2\Documents\Chris Fitzpatrick\SIG360 16-0466 LoR Imperial West Block F\Shaftwall to 0.25 U vlaue.JDP Shaftwall to 0.25 U vlaue
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 120 of 168


KS-0247-K - 26/09/2017 Rev L

Condensation Risk Analysis (no account taken of thermal bridges)


3 - Dwellings with low occupancy
Jan (worst) Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
20.0C 58.2% 20.0C 57.2% 20.0C 57.3% 20.0C 57.8% 20.0C 61.6% 20.0C 66.1% 20.0C 71.0% 20.0C 71.6% 20.0C 68.7% 20.0C 64.6% 20.0C 60.1% 20.0C 59.0%
3.5C 86.0% 3.8C 82.5% 5.7C 80.0% 8.0C 77.0% 11.3C 77.0% 14.4C 76.0% 16.5C 76.5% 16.1C 78.5% 13.8C 81.5% 10.7C 84.0% 6.4C 85.5% 4.5C 86.5%

Interface Dewpoint Vapour Saturated Worst Peak Conden-


Temp. Temp. Pressure V.P. Cond. Buildup sation
C C (kPa) (kPa) (g/m) (g/m)
1 Outside surface resistance
3.6 1.4 0.67 0.79 No
2 Gyproc CoreBoard
3.9 2.9 0.75 0.81 No
3 Airspace, heat flow horizontal, 12.5
mm thick
4.5 2.9 0.75 0.84 No
4 Isowool Acoustic Partition Roll
(APR)
6.9 3.1 0.76 1.00 No
5 Airspace, heat flow horizontal, 12.5
mm thick
7.5 3.1 0.76 1.04 No
6 Gyproc Fireline
7.7 4.2 0.83 1.05 No
7 Gyproc Fireline
7.9 5.3 0.89 1.07 No
8 Rockwool RWA45 Slab (Laminated
to 12.5mm plasterboard)
19.3 6.1 0.94 2.24 No
9 Standard Plasterboard (Laminated
to RWA45)
19.5 11.6 1.36 2.27 No
10 Inside surface resistance
Worst case internal / external conditions for graph : 20.0C @ 58.2%RH / 3.5C @ 86.0%RH

25C

Internal
20C 58.2%RH

15C
9 7 5 3
10C 8 6 4 2

5C External
86.0%RH

0C

-5C Inside Outside


Scale 1:2 Rsi=0.13 Rso=0.04

Page 4 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jul 2017
Licensed to Sheffield Insulations Limited
C:\Users\mstearne2\Documents\Chris Fitzpatrick\SIG360 16-0466 LoR Imperial West Block F\Shaftwall to 0.25 U vlaue.JDP Shaftwall to 0.25 U vlaue
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 121 of 168


KS-0247-K - 26/09/2017 Rev L

General Information

Plasterboard Dry Linings


Partitions
Wall Linings
Ceilings

Page 122 of 168


KS-0247-K - 26/09/2017 Rev L

SPEEDLINE 'C' Stud at nominal 600mm centres

Single layer of plywood min 150mm high


to suit patress requirements
with notch to accommodate flange of stud

Insulation as per specification Boarding as per specification

SPEEDLINE Metal Angle fixed to frame with wafer or


pan head screws

CDR No: 349 SCALE: NTS DATE: 15/04/16


PLYWOOD PATRESS NOTCHED
WITHIN PARTITION OR LINING SYSTEM

Page 123 of 168


KS-0247-K - 26/09/2017 Rev L

Deflection head track to suit partition

Deflection Allowance **
Deflection head packers to suit deflection allowance

** Studs as door frame detail with timber


insert
Box opening lined with same boards as partition

Studs sections above door head

Door Head Track

CDR No: 369 SCALE: NTS DATE: 04/05/16


DUCT ABOVE DOOR FRAME

Page 124 of 168


KS-0247-K - 26/09/2017 Rev L

Page 125 of 168


KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Service Support Plate adhered to stud with


pre-installed tape

Plywood pattress up to a maximum of 600mm high.


for greater heights additional support is required

SPEEDLINE 'C' Stud, type and centres as system


specification

Plasterboards not shown for clarity

CDR No: 227 SCALE: NTS DATE: 05/02/16


SPEEDLINE SERVICE SUPPORT PLATE CONCEPT
USED TO FIX 18mm PLYWOOD WITHIN PARTITION
OR LINING SYSTEM
Page 126 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE 'C' Stud at nominal 600mm centres

SPEEDLINE Socket Pad fixed to rear of electrical box

OPTION A

SPEEDLINE Fire Rated Acoustic Sealant if required to fill small gaps

OPTION B

SPEEDLINE Fire Rated Acoustic Sealant if required to fill small gaps

SPEEDLINE Socket Pad fixed inside electrical box

CDR No: 229 SCALE: NTS DATE: 05/02/16


SOCKET BOX FITTING TO PLASTERBOARD USING SOCKET
PADS WITHIN PARTITION OR LINING SYSTEM

Page 127 of 168


KS-0247-K - 26/09/2017 Rev L

Page 128 of 168


KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Studs as per specification

Timber support frame secured to SPEEDLINE Stud frame

SPEEDLINE Studs as per specification

Timber support frame

SPEEDLINE Track as per specification

CDR No: 385 SCALE: NTS DATE: 18/05/16


HAND WASH BASIN & GRAB TIMBER RAIL SUPPORT FRAME

Page 129 of 168


KS-0247-K - 26/09/2017 Rev L

Page 130 of 168


KS-0247-K - 26/09/2017 Rev L

Page 131 of 168


KS-0247-K - 26/09/2017 Rev L

Page 132 of 168


KS-0247-K - 26/09/2017 Rev L

Page 133 of 168


KS-0247-K - 26/09/2017 Rev L

Page 134 of 168


KS-0247-K - 26/09/2017 Rev L

Page 135 of 168


KS-0247-K - 26/09/2017 Rev L

Page 136 of 168


KS-0247-K - 26/09/2017 Rev L

Page 137 of 168


KS-0247-K - 26/09/2017 Rev L

Page 138 of 168


KS-0247-K - 26/09/2017 Rev L

Page 139 of 168


KS-0247-K - 26/09/2017 Rev L

Additional Project Information

Page 140 of 168


KS-0247-K - 26/09/2017 Rev L

SIG 360 Technical Centre


T1 Trafford Point
Twining Road
Off Ashburton Road West
Manchester
M17 1SH

Project Information
Reference Roof Block F with Rockwool RWA45 Soffit
Date 30th June 2017
Project SIG360 16-0466 - LOR Imperial West Block\JPA, XML
Construction Type
Element : Flat roof - Uvalue Element 1
Internal surface emissivity : High External surface emissivity: High
Thickness Thermal Thermal Pitch Bridge details
Conductivity
Resistance () Air gaps
(mm) (W/mK) (mK/W) (Level, Delta U")
Outside surface resistance - - 0.130
50mm concrete paver 50.0 0.000 0.000
15mm void 15.0 - 0.000
Dow MinK filter membrane - - -
Enertherm XPS 100.0 0.034 2.941 L:0 0.000W/mK
10mm hotmelt 10.0 1.200 0.008
High density (2400 kg/m3) concrete 200.0 2.000 0.100
Rockwool RWA45 Slab (25mm to 200mm) 140.0 0.035 4.000 L:0 0.000W/mK
Airspace, heat flow upwards 10.0 - 0.150 0.100% Ceiling
Suspension System
(10.0mm)
(Bridged un-vented cavity - width=2000.0mm, hro=5.100, E1=0.900, E2=0.900, upward heat flow)
Unknown Soffit Liner 12.5 0.000 0.000 L:0 0.000W/mK
Inside surface resistance - - 0.100
Total thickness 537.5mm
U-value = 0.14 W/mK
U-value, Combined Method : 0.135 W/mK (upper/lower limit 7.429 / 7.365mK/W, dUf 0.0000, dUg 0.0000, dUp0.0000, dUr0.0005,
dUrc1 0.0000, dUrc2 0.0000)
Correction factors
Rainwater cooling
f.x : 0.001(W.day)/(m.K.mm)
p : 3.000mm/day
Insulation Layer(s) : 50mm concrete paver, Enertherm XPS
Delta Ur: 0.0005 W/m.K
Air gaps, Delta Ug = 0.000W/mK
(Based on the combined method for determining U-values of structures containing repeating thermal bridges)

Page 1 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jun 2017
Licensed to Sheffield Insulations Limited
\\SIG-FS02\depts\Insulslab360\SIG360\Enquiries\2016 Projects\SIG360 16-0466 - LOR Imperial West Block\JPA, XML\Roof Block F with Rockwool RWA45
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 141 of 168


KS-0247-K - 26/09/2017 Rev L
Thickness Thermal Thermal Vapour Vapour
Conductivity Resistance Resistivity Resistance
(mm) (W/mK) (mK/W) (MNs/gm) (MNs/g)
Outside surface resistance - - 0.130 - -
50mm concrete paver 50.0 0.000 0.000 0.00 0.00
15mm void 15.0 - 0.000 - 0.08
Dow MinK filter membrane - - - - 0.50
Enertherm XPS 100.0 0.034 2.941 1000.00 100.00
10mm hotmelt 10.0 1.200 0.008 - 10000.00
High density (2400 kg/m3) concrete 200.0 2.000 0.100 650.00 130.00
Rockwool RWA45 Slab (25mm to 200mm) 140.0 0.035 4.000 5.90 0.83
Airspace, heat flow upwards 10.0 - 0.150 - 0.00
(Bridged un-vented cavity - width=2000.0mm, hro=5.100, E1=0.900, E2=0.900, upward heat flow)
Unknown Soffit Liner 12.5 0.000 0.000 60.00 0.75
Inside surface resistance - - 0.100 - -
Total thickness 537.5mm

Page 2 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jun 2017
Licensed to Sheffield Insulations Limited
\\SIG-FS02\depts\Insulslab360\SIG360\Enquiries\2016 Projects\SIG360 16-0466 - LOR Imperial West Block\JPA, XML\Roof Block F with Rockwool RWA45
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 142 of 168


KS-0247-K - 26/09/2017 Rev L

Structure element : Flat roof


Condensation calculations performed in accordance with BS5250:2011

Condensation is occuring at the following layers interfaces:-

Month Int Int Ext Ext


(C) (%RH) (C) (%RH)

Jan 20.00 48.50 3.50 86.00


Feb 20.00 48.80 3.80 82.50
Mar 20.00 50.70 5.70 80.00
Apr 20.00 53.00 8.00 77.00
May 20.60 56.30 11.30 77.00
Jun 22.20 59.40 14.40 76.00
Jul 23.30 61.50 16.50 76.50
Aug 23.10 61.10 16.10 78.50
Sep 21.90 58.80 13.80 81.50
Oct 20.30 55.70 10.70 84.00
Nov 20.00 51.40 6.40 85.50
Dec 20.00 49.50 4.50 86.50

Gc = Monthly moisture accumulation per area at an interface


Ma = Accumulated moisture content per area at an interface

Peak accumulated moisture content per area at interface (Ma) = 0.00000 Kg/m

Annual moisture accumulation = 0.00000 Kg/m

Page 3 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jun 2017
Licensed to Sheffield Insulations Limited
\\SIG-FS02\depts\Insulslab360\SIG360\Enquiries\2016 Projects\SIG360 16-0466 - LOR Imperial West Block\JPA, XML\Roof Block F with Rockwool RWA45
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 143 of 168


KS-0247-K - 26/09/2017 Rev L

Condensation Risk Analysis (no account taken of thermal bridges)


3 - Dwellings with low occupancy
Jan (worst) Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
20.0C 48.5% 20.0C 48.8% 20.0C 50.7% 20.0C 53.0% 20.6C 56.3% 22.2C 59.4% 23.3C 61.5% 23.1C 61.1% 21.9C 58.8% 20.3C 55.7% 20.0C 51.4% 20.0C 49.5%
3.5C 86.0% 3.8C 82.5% 5.7C 80.0% 8.0C 77.0% 11.3C 77.0% 14.4C 76.0% 16.5C 76.5% 16.1C 78.5% 13.8C 81.5% 10.7C 84.0% 6.4C 85.5% 4.5C 86.5%

Interface Dewpoint Vapour Saturated Worst Peak Conden-


Temp. Temp. Pressure V.P. Cond. Buildup sation
C C (kPa) (kPa) (g/m) (g/m)
1 Outside surface resistance
3.8 1.4 0.67 0.80 No
2 50mm concrete paver
3.8 1.4 0.67 0.80 No
3 15mm void
3.8 1.4 0.67 0.80 No
4 Dow MinK filter membrane
3.8 1.4 0.67 0.80 No
5 Enertherm XPS
10.3 1.5 0.68 1.25 No
6 10mm hotmelt
10.3 8.7 1.13 1.26 0 in Mar No
7 High density (2400 kg/m3)
concrete
10.6 8.8 1.13 1.27 0 in Mar No
8 Rockwool RWA45 Slab (25mm to
200mm)
19.4 8.8 1.13 2.26 No
9 Airspace, heat flow upwards
19.8 8.8 1.13 2.31 No
10 Unknown Soffit Liner
19.8 8.8 1.13 2.31 No
11 Inside surface resistance
Worst case internal / external conditions for graph : 20.0C @ 48.5%RH / 3.5C @ 86.0%RH

Outside
2 Rso=0.13
43
5
Scale 1:8
6

109

Internal External Inside


48.5%RH 86.0%RH Rsi=0.10
25C 20C 15C 10C 5C 0C -5C

Page 4 of 4
JPA Designer Version 6.04a1 009 JPA Technical Literature Jun 2017
Licensed to Sheffield Insulations Limited
\\SIG-FS02\depts\Insulslab360\SIG360\Enquiries\2016 Projects\SIG360 16-0466 - LOR Imperial West Block\JPA, XML\Roof Block F with Rockwool RWA45
The calculation is based on information provided by you, and SIG Trading Limited accepts no liability for errors or omissions in the input data orfor
errors or omissions in the input data or errors resulting from any inaccuracy of inputted data. Information given regarding systems, quantities or
products, whether this is verbal or written isgiven in good faith, and on the basis that specifiers and buyers upon receiving the said information, will
make their own determination as to the fitness and suitability for their purposes, prior to specification use or purchase. Any condensation
calculation provided is a recommendation only and SIG Trading Limited does not accept liability for any losses or damages arising out of or in
connection with use of the condensation calculation.

Page 144 of 168


KS-0247-K - 26/09/2017 Rev L

Page 145 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017

SECTION 1: Identification of the substance/mixture and of the company/undertaking

1.1 Product identifier


Trade name : SPEEDLINEFireRatedIntumescentAcousticSealant
1.2 Relevant identified uses of the substance or mixture and uses advised against

1.3 Details of the supplier of the safety data sheet


Company : SIG PLC
Hillsborough Works
Langsett Road
Sheffield
S6 2LW

Telephone : 0114 2318030

E-mail address : enquiries@speedlinedrywall.co.uk

1.4 Emergency telephone number


Emergency telephone : 0044 113 240 3456 (office hours only)
number

SECTION 2: Hazards identification

2.1 Classification of the substance or mixture


Type of product : Mixture

Classification (REGULATION (EC) No 1272/2008)


Not a hazardous substance or mixture.

2.2 Label elements


Labelling (REGULATION (EC) No 1272/2008)
Not a hazardous substance or mixture.
Additional Labelling:
EUH210 Safety data sheet available on request.

2.3 Other hazards


This substance/mixture contains no components considered to be either persistent, bioaccumulative
and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Contains a biocide in order to protect the product. Active ingredient: 2-hydroxybiphenyl, 90-43-7.
Please use biocides responsibly.

Country GB 100000008351 1/9

Page 146 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017

SECTION 3: Composition/information on ingredients


3.2 Mixtures
Hazardous components
Chemical name Classification Concentration
CAS-No. (REGULATION (EC) [%]
EC-No. No 1272/2008)
Registration number
1-isopropyl-2,2-dimethyltrimethylene diisobutyrate Aquatic Chronic3; >= 5 - < 10
6846-50-0 H412
229-934-9
01-2119451093-47-XXXX

For the full text of the H-Statements mentioned in this Section, see Section 16.

SECTION 4: First aid measures

4.1 Description of first aid measures


General advice : No hazards which require special first aid measures.

If inhaled : Move to fresh air.

In case of skin contact : Take off contaminated clothing and shoes immediately.
Wash off with soap and plenty of water.

In case of eye contact : Remove contact lenses.


Keep eye wide open while rinsing.

If swallowed : Do not induce vomiting without medical advice.


Rinse mouth with water.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.

4.2 Most important symptoms and effects, both acute and delayed
Symptoms : See Section 11 for more detailed information on health effects
and symptoms.

Risks : No known significant effects or hazards.

4.3 Indication of any immediate medical attention and special treatment needed
Treatment : Treat symptomatically.

SECTION 5: Firefighting measures

5.1 Extinguishing media


Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and
the surrounding environment.

Country GB 100000008351 2/9

Page 147 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017
5.2 Special hazards arising from the substance or mixture

Hazardous combustion prod- : No hazardous combustion products are known


ucts

5.3 Advice for firefighters


Special protective equipment : In the event of fire, wear self-contained breathing apparatus.
for firefighters

Further information : Standard procedure for chemical fires.

SECTION 6: Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures


Personal precautions : For personal protection see section 8.

6.2 Environmental precautions


Environmental precautions : No special environmental precautions required.

6.3 Methods and materials for containment and cleaning up


Methods for cleaning up : Wipe up with absorbent material (e.g. cloth, fleece).
Keep in suitable, closed containers for disposal.

6.4 Reference to other sections


For personal protection see section 8.

SECTION 7: Handling and storage

7.1 Precautions for safe handling


Advice on safe handling : For personal protection see section 8. No special handling
advice required. Follow standard hygiene measures when
handling chemical products

Advice on protection against : Normal measures for preventive fire protection.


fire and explosion

Hygiene measures : When using do not eat or drink. When using do not smoke.

7.2 Conditions for safe storage, including any incompatibilities


Requirements for storage : Keep container tightly closed in a dry and well-ventilated
areas and containers place. Store in accordance with local regulations.

Country GB 100000008351 3/9

Page 148 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017

Advice on common storage : No special restrictions on storage with other products.

Other data : No decomposition if stored and applied as directed.

7.3 Specific end use(s)


Specific use(s) : No data available

SECTION 8: Exposure controls/personal protection

8.1 Control parameters

Contains no substances with occupational exposure limit values.

8.2 Exposure controls

Personal protective equipment


Eye protection : Safety glasses

Hand protection : Chemical-resistant, impervious gloves complying with an ap-


proved standard must be worn at all times when handling
chemical products. Reference number EN 374. Follow manu-
facturer specifications.

Butyl rubber/nitrile rubber gloves (0,4 mm),


Recommended: Butyl rubber/nitrile rubber gloves.

Skin and body protection : Protective clothing (e.g. Safety shoes acc. to EN ISO 20345,
long-sleeved working clothing, long trousers). Rubber aprons
and protective boots are additionaly recommended for mixing
and stirring work.

Respiratory protection : No special measures required.

Environmental exposure controls


General advice : No special environmental precautions required.

SECTION 9: Physical and chemical properties

9.1 Information on basic physical and chemical properties


Appearance : paste within cartridges of 310ml, 900ml & Foil outer 600ml
Colour : white

Odour : odourless

Country GB 100000008351 4/9

Page 149 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017
Odour Threshold : No data available

Flash point : ca. 93 C

Autoignition temperature : No data available

Lower explosion limit (Vol-%) : No data available

Upper explosion limit (Vol-%) : No data available

Flammability : No data available

Oxidizing properties : No data available

pH : 8,5 - 9,5 at 20 C

Melting point/range / Freez- : No data available


ing point
Boiling point/boiling range : No data available

Vapour pressure : 23 hPa

Density : ca.1,6 g/cm3


at 20 C

Water solubility : soluble

Partition coefficient: n- : No data available


octanol/water
Viscosity, dynamic : No data available

Viscosity, kinematic : > 20,5 mm2/s


at 40 C

Relative vapour density : No data available

Evaporation rate : No data available

9.2 Other information


No data available

SECTION 10: Stability and reactivity

10.1 Reactivity
No dangerous reaction known under conditions of normal use.
10.2 Chemical stability
The product is chemically stable.
10.3 Possibility of hazardous reactions
Hazardous reactions : No hazards to be specially mentioned.

10.4 Conditions to avoid : No data available


Country GB 100000008351 5/9

Page 150 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017

10.5 Incompatible materials


Materials to avoid : No data available

10.6 Hazardous decomposition products


No decomposition if stored and applied as directed.
SECTION 11: Toxicological information

11.1 Information on toxicological effects

Acute toxicity
Not classified based on available information.#
Components:
1-isopropyl-2,2-dimethyltrimethylene diisobutyrate:
Acute oral toxicity : LD50 Oral (Rat): > 3.200 mg/kg

Acute dermal toxicity : LD50 Dermal (Rat): > 5.000 mg/kg

Skin corrosion/irritation
Not classified based on available information.#
Serious eye damage/eye irritation
Not classified based on available information.#
Respiratory or skin sensitisation
Skin sensitisation: Not classified based on available information.#
Respiratory sensitisation: Not classified based on available information.#
Germ cell mutagenicity
Not classified based on available information.
Carcinogenicity
Not classified based on available information.#
Reproductive toxicity
Not classified based on available information.
STOT - single exposure
Not classified based on available information.#
STOT - repeated exposure
Not classified based on available information.#
Aspiration toxicity
Not classified based on available information.#

SECTION 12: Ecological information

12.1 Toxicity
No data available
12.2 Persistence and degradability : No data available

Country GB 100000008351 6/9

Page 151 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment

Product:
Assessment : This substance/mixture contains no components considered
to be either persistent, bioaccumulative and toxic (PBT), or
very persistent and very bioaccumulative (vPvB) at levels of
0.1% or higher.

12.6 Other adverse effects


Product:
Additional ecological infor- : There is no data available for this product.
mation

Country GB 100000008351 7/9

Page 152 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017

SECTION 13: Disposal considerations

13.1 Waste treatment methods


Product : The generation of waste should be avoided or minimized
wherever possible.
Empty containers or liners may retain some product residues.
This material and its container must be disposed of in a safe
way.
Dispose of surplus and non-recyclable products via a licensed
waste disposal contractor.
Disposal of this product, solutions and any by-products should
at all times comply with the requirements of environmental
protection and waste disposal legislation and any regional
local authority requirements.
Avoid dispersal of spilled material and runoff and contact with
soil, waterways, drains and sewers.

SECTION 14: Transport information

ADR
Not dangerous goods
IATA
Not dangerous goods
IMDG
Not dangerous goods

14.6 Special precautions for user


No data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable

SECTION 15: Regulatory information

15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
Prohibition/Restriction
REACH - Restrictions on the manufacture, placing on : Not applicable
the market and use of certain dangerous substances,
preparations and articles (Annex XVII)

REACH - Candidate List of Substances of Very High : None of the components are listed
Concern for Authorisation (Article 59). (=> 0.1 %).

REACH - List of substances subject to authorisation : Not applicable


(Annex XIV)

Country GB 100000008351 8/9

Page 153 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017

REACH Information: All substances contained in our Products are


- preregistered or registered by our upstream suppliers, and/or
- preregistered or registered by us, and/or
- excluded from the regulation, and/or
- exempted from the registration.

Seveso III: Directive 2012/18/EU of the European Parliament and of the Council on the control of ma-
jor-accident hazards involving dangerous substances.
Not applicable

VOC-CH (VOCV) : < 0,01 %


no VOC duties

VOC-EU (solvent) : < 0,01 %

If other regulatory information applies that is not already provided elsewhere in the Safety Data
Sheet, then it is described in this subsection.

Health, safety and environ- mental regulation/legislation specific for the substance or mixture:

The Chemicals (Hazard Information and Packaging for Sup- ply) Regulations 2002
Control of Substances Hazardous to Health Regulations 2002 The Management of Health and
Safety at Work Regulations 1999
Health and Safety at Work Act 1974
Environmental Protection Act 1990 & Subsidiary Regulations

15.2 Chemical safety assessment

This product contains substances for which Chemical Safety Assessments are still required.

SECTION 16: Other information


Full text of H-Statements
H412 Harmful to aquatic life with long lasting effects.

Full text of other abbreviations


Aquatic Chronic Chronic aquatic toxicity
ADR Accord europen relatif au transport international des marchandises
Dangereuses par Route
CAS Chemical Abstracts Service
DNEL Derived no-effect level
EC50 Half maximal effective concentration
GHS Globally Harmonized System
IATA International Air Transport Association
IMDG International Maritime Code for Dangerous Goods
LD50 Median lethal dosis (the amount of a material, given all at once, which
causes the death of 50% (one half) of a group of test animals)
LC50 Median lethal concentration (concentrations of the chemical in air that
kills 50% of the test animals during the observation period)
MARPOL International Convention for the Prevention of Pollution from Ships,
Country GB 100000008351 9/9

Page 154 of 168


KS-0247-K - 26/09/2017 Rev L

SAFETY DATA SHEET


According to Regulation (EC) No. 1907/2006
SpeedlineFireRatedIntumescent
AcousticSealant(Acrylic)
Revision Date 0 3 .01.2017 Version 0.0 Print Date 03.01.2017
1973 as modified by the Protocol of 1978
OEL Occupational Exposure Limit
PBT Persistent, bioaccumulative and toxic
PNEC Predicted no effect concentration
REACH Regulation (EC) No 1907/2006 of the European Parliament and of the
Council of 18 December 2006 concerning the Registration, Evaluation,
Authorisation and Restriction of Chemicals (REACH), establishing a
European Chemicals Agency
SVHC Substances of Very High Concern
vPvB Very persistent and very bioaccumulative

The information contained in this Safety Data Sheet corresponds to our level of knowledge at the
time of publication. All warranties are excluded. Our most current General Sales Conditions shall
apply. Please consult the product data sheet prior to any use and processing.

Changes as compared to previous version !

Country GB 100000008351 10 /

Page 155 of 168


KS-0247-K - 26/09/2017 Rev L

Standard Boards
Knauf Wallboard
Knauf offers a wide range of sizes of standard plasterboard
to meet all basic drylining requirements. Use in conjunction
with Knauf jointing compounds, plasters, fixings, plasterboard
adhesive and metal systems.
Knauf Wallboard is plasterboard with an ivory paper
face ideally suited to receive a plaster finish or for
direct decoration.
Compliance: EN 520, Type A.

Square Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

9.5 900 1800 243699 100 162.0 1.01


1200 2400 243690 92 265.0 1.65
12.5 900 1800 243667 80 129.6 1.06
2400 243669 80 172.8 1.41
1200 2400 243643 72 207.4 1.69
2700 243654 60 194.4 1.58
3000 168040 60 216.0 1.76
15.0 900 2400 243684 60 129.6 1.33
1200 2400 168044 60 172.8 1.77

Tapered Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

9.5 1200 2400 243692 92 265.0 1.65


12.5 900 1800 243668 80 129.6 1.06
2400 243670 80 172.8 1.41
1200 2400 243647 72 207.4 1.69
2500 243651 72 216.0 1.76
2700 243657 60 194.4 1.58
3000 63461 60 216.0 1.76
15.0 900 1800 243683 60 97.2 1.00
2400 243685 60 129.6 1.33
1200 2400 168043 60 172.8 1.77
2500 58259 48 144.0 1.47
2700 243677 48 155.5 1.60
3000 58260 48 172.8 1.77

www.knauf.co.uk

Page 156 of 168


KS-0247-K - 26/09/2017 Rev L

High Performance Boards


Knauf Moisture Panel
Knauf high performance boards offer the convenience of
plasterboard but with significantly higher performance in key
areas. The Knauf high performance board range includes
solutions for elements of fire, moisture, vapour, sound, impact
resistance, X-ray resistance and even temperature regulation.
Knauf Moisture Panel is a high performance plasterboard for
use in internal areas of high humidity and temporary
external exposure.
Compliance: EN 520, Types A and H2.

Square Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

12.5 1200 2400 292680 60 172.8 1.64

Tapered Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

12.5 1200 2400 222210 60 172.8 1.64


2700 68551 60 194.4 1.85
3000 243622 54 194.4 1.85
15.0 1200 2400 168091 60 172.8 1.76
3000 400134 48 172.8 1.76

www.knauf.co.uk

Page 157 of 168


KS-0247-K - 26/09/2017 Rev L

High Performance Boards


Knauf Fire Panel
Knauf high performance boards offer the convenience of
plasterboard but with significantly higher performance in key
areas. The Knauf high performance board range includes
solutions for elements of fire, moisture, vapour, sound, impact
resistance, X-ray resistance and even temperature regulation.
Knauf Fire Panel offers superior fire protection.
Compliance: EN 520, Types A and F.

Square Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

12.5 900 1800 243496 80 129.6 1.30


1200 2400 243481 60 172.8 1.73

Tapered Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

12.5 900 1800 243498 80 129.6 1.30


1200 2400 244412 60 172.8 1.73
2700 243489 60 194.4 1.94
3000 243493 48 172.8 1.73
15.0 1200 2400 243501 48 138.2 1.66
2700 243507 48 155.5 1.87
3000 243513 42 151.2 1.82

www.knauf.co.uk

Page 158 of 168


KS-0247-K - 26/09/2017 Rev L

High Performance Board


Knauf Core Board
Knauf high performance boards offer the convenience of
plasterboard but with significantly higher performance in key
areas. The Knauf high performance board range includes
solutions for elements of fire, moisture, vapour, sound, impact
resistance, X-ray resistance and even temperature regulation.
Knauf Core Board is designed to be used in conjunction with
the Knauf Shaftwall systems. It has both fire and moisture
resistant qualities.
Compliance: EN 520 Types A, D, F, H1, I and R.

Square Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

19.0 600 3000 81062 32 57.6 0.93

www.knauf.co.uk

Page 159 of 168


KS-0247-K - 26/09/2017 Rev L

High Performance Boards


Knauf Soundshield Plus
Knauf high performance boards offer the convenience of
plasterboard but with significantly higher performance in key
areas. The Knauf high performance board range includes
solutions for elements of fire, moisture, vapour, sound, impact
resistance, X-ray resistance and even temperature regulation.
Knauf Soundshield Plus is the ideal plasterboard where sound
reduction is of particular importance. Its high mass and tuned
core give enhanced acoustic performance, excellent fire
resistance and severe duty impact rating when used on
Knauf systems.
Compliance: EN 520, Types A, D, F and I.

Tapered Edge
Dimensions (mm) Material No. Pallet Details

Thickness Width Length Boards m2 Tonnes (Approx.)

12.5 1200 2400 292622 56 161.2 1.86


2700 292620 48 155.5 1.79
3000 292627 42 151.2 1.74
15.0 900 2400 292644 60 129.6 1.66
1200 2400 292646 48 138.2 1.77
2700 292677 42 136.1 1.74
3000 292678 36 129.6 1.66

www.knauf.co.uk

Page 160 of 168


KS-0247-K - 26/09/2017 Rev L

High Performance Boards


Knauf high performance boards offer the convenience of
plasterboard but with significantly higher performance in key
areas. The Knauf high performance board range includes
solutions for elements of fire, moisture, vapour, sound, impact
resistance, X-ray resistance and even temperature regulation.

Knauf Performance Plus


Knauf Performance Plus, our highest specification plasterboard,
has a high-density core with added performance-enhancing
ingredients. The result is a board with extremely high levels
of sound, moisture, fire and impact resistance, ideally suited
to schools, hospitals and other large commercial projects.
Compliance: EN 520, Types A, D, F, H1, I and R.

Tapered Edge

Dimensions (mm) Material No. Pallet Details


Thickness Width Length Boards m2 Tonnes (Approx.)

12.5 1200 2400 400177 60 172.8 1.98


3000 400185 48 172.8 1.98
15.0 1200 2400 400189 48 138.2 1.77
3000 400195 36 129.6 1.66
































www.knauf.co.uk
Page 161 of 168
KS-0247-K - 26/09/2017 Rev L

SPEEDLINE Systems

General Notes:

Fire Resistance:
Fire resistance performance figures apply laboratory test on elements imperforate partitions. Fire resistance
information is based on the results of tests carried out to BS476: part 22 1987 or assessments based on these
tests. Some of our more recent fire tests have been conducted to European standard BS EN 1364-1: 1999
which is actually more stringent than the existing British Standard BS 476.

Sound Insulation:
Sound insulation performance figures apply laboratory test on elements imperforate partitions. Sound
insulation is based on the results of tests carried out to BS EN ISO 10140-2:2010 or assessments based on
these tests. Single figure ratings (RW) have been calculated to BS EN ISO 717-1.

Mechanical Performance:
Mechanical performance of Medium Duty, Heavy Duty or Severe Duty is determined from tests carried out to
BS 5234: 1992 or assessments based on these tests.

Galvanised Metal:
All sections are formed from pre galvanised mild steel to BS EN 10346: 2009.

Manufacture:
All sections are manufactured in accordance with BS EN 14195: 2005 which is the European Standard for
production of metal framing components for gypsum plasterboard systems used to build non load bearing
partitions, wall linings and ceilings.

CE Marking:
All relevant profiles conform to BS EN 14195: 2005. The products within this range are intended for use as
metal framing components within building construction works in conjunction with gypsum plasterboard where
the assembly is non-load bearing. The reaction to fire is Euroclass A1, being no contribution to fire. All
relevant products are ink marked with the official CE logo.

Test Data:
All sound insulation data is based on laboratory evaluation of the building element in isolation and cannot
reproduce your installed local conditions.
The actual tests carried out are used to offer an order of magnitude comparison for the performance of the
various systems. Sound insulation on site is a function of the partition chosen and the associated structures in
which it is installed. We cannot take any responsibility for overall design and we would advise that specialist
advice is sought at an early stage of design. This document must be read in conjunction with the SPEEDLINE
Product Application Guide.

All test data and system specifications are for systems constructed with materials and components as shown.
The inclusion of other components without prior approval or constructed on site contrary to these documents
will invalidate test certification and system performance.
The above information is provided in good faith on the basis of details received, which are assumed to
include all relevant facts.

Page 162 of 168


KS-0247-K - 26/09/2017 Rev L

K10 Notes

Dry Lining Generally:

Handle and store materials in accordance with BS 8212 section 5. Do not use damaged boards
Cut boards neatly and accurately without damage to core or tearing of paper facing. Keep cut edges to a minimum and
position at internal angles.
Finish neatly giving flush, smooth, flat surfaces free from bowing and abrupt changes of level.

Preparation of Solid Backgrounds:

Complete all cutting, chasing, plugging and making good.


Remove all loose material by brushing thoroughly.
Remove all oil, grease, wallpaper, etc. by scrubbing with water and detergent. Rinse with clean water and allow to dry.
For adhesive fixed wall linings, adjust suction of background as necessary using primers or bonding agents recommended
for the purpose.

Metal Stud Framing (C & I Stud Partitions and I Stud Wall Lining):

Set out floor / ceiling track and perimeter studs to give framework that is accurately aligned with a true vertical plane. Fix
securely at all perimeters at not more than 600 mm centres. For 94 mm and 148 mm tracks we recommend two rows of
staggered fixings at not more than 600 mm centres.
Position studs at equal centres to suit specific linings, maintaining sequence across openings. Provide additional studs as
necessary to ensure support to all vertical edges of boards
Accurately form openings to receive door sets using boxed studs and or timber framing as necessary to achieve the
strength grade requirement to BS 5234.
Single layer C stud partition installations should be constructed from side to side (not built on one side only) to prevent
stepping at joints.

Metal Framing for Wall Lining System:

Set out WL60 floor / ceiling track accurately aligned and fix securely at maximum 600 mm centres with the shallow leg
towards the wall. Position AWL03 or AWL04 fixing brackets at maximum 800 mm centres and secure to wall. Slot WL507
wall liner section at equal centres to suit specific linings into floor / ceiling track, maintaining sequence across openings.
Secure brackets to wall liner section using suitable screws. If brackets protrude beyond the face of the framework, bend the
overhang over at 90 degrees or cut off.

Suspended Ceilings and Grids (MF & Ceiling Liner System):

Set out accurately aligned and level. Grid members and hangers must be installed at the correct centres to suit specified
linings and imposed loads.
Additional grid members may be required to provide bracing and stiffening at upstands, partition heads and access
hatches.
MF Ceiling System primary channel must be supported using 25 x 25 x 90 degree angle with angle fixing bracket linking
to the soffit.

Fixing Plasterboard to Metal Framing:

Fix securely to all supports working from the centre of each board using drywall screws of the appropriate length.

Page 163 of 168


KS-0247-K - 26/09/2017 Rev L

Partitions and Wall Linings:

Single Layer installations


Plasterboard must be fixed at 300 mm maximum centres.
Plasterboard vertical joints must be staggered from one side of the partition to the other.
Double Layer Installations
Inner layers can be fixed at 600 mm maximum centres but outer layers must be fixed at 300 mm maximum centres
Plasterboard vertical joints on the inner layer must be staggered from one side of the partition to the other. The outer layer
of plasterboard must be fixed with all joints staggered in relation to the inner layer
Position screws not less than 10 mm from the edge of the board
Recess heads of screws below surface of plasterboard but do not break paper or gypsum core.

Fixing Drywall Adhesive Board Linings:

Apply dabs of SPEEDLINE Drywall Adhesive to the background for one board at a time, to achieve at least 20% contact
with the surface area of the boards:
One row of horizontal dabs to coincide with the top edge of each board.
One continuous line of horizontal dabs to coincide with the bottom edge of each board.
One row of vertical dabs to coincide with the side edges of each board, and additional vertical row(s) at the following max
centres:
- 400 mm for boards 9.5 mm thick x 1200 mm wide.
- 600 mm for boards 12.5 mm thick x 1200 mm wide.
- 450 mm for boards 9.5 mm thick x 900 mm wide.
- 450 mm for boards 12.5 mm thick x 900 mm wide.
Ensure dabs are at least 25 mm from board edges.
For linings to receive ceramic finishes, apply one additional row of dabs at mid storey height.

Thermal Seals for Drywall Adhesive Board Linings:


Manufacturer and reference: SIG PLC, SPEEDLINE Drywall Adhesive or SPEEDLINE Fire Rated Acoustic Sealant.
Before/during installation of dry lining system, fully seal all airpaths around the perimeter of the background and around
structural openings and service penetrations through the background.
Apply as a continuous fillet, leaving no gaps.

Ceilings:

Single layer or double layer installation


Plasterboard must be fixed at 230 mm maximum centres and reduced to 150 mm centres at board ends and the
perimeters of the room.
Inner Layer plasterboard must be fixed with the bound edges of the plasterboard at 90 degrees to the metal framework
with board ends staggered by half a board length.
Outer layer plasterboard must be fixed with all joints staggered in relation to the inner layer.
Position screws not less than 10 mm from the edge of the board
Recess heads of screws below surface of plasterboard but do not break paper or gypsum core.

Minor Damage in Existing Plasterboard:

Repair small areas of broken plasterboard by cutting away paper, removing loose core material and filling with joint filler.
Apply PVAC sealer to exposed plaster and cut edge of paper before filling. Finish off to give a smooth, flush surface ready
for decoration.

Major Damage in Existing Plasterboard:

Repair large areas of broken plasterboard by cutting out and replacing with an identical piece of plasterboard. Form a
neat hole with sides vertical and horizontal. Fix the patch using the same method as the existing dry lining ensuring full
support to all edges of the new and existing plasterboard. Fill joints, apply tape and finish off to give a smooth, flush
surface ready for redecoration.

Page 164 of 168


KS-0247-K - 26/09/2017 Rev L

Fixtures:

Heavy or medium duty fixtures must be attached to the metal framework. If necessary, additional framework must be added.
Partition Brace fixed horizontally between studs is particularly useful for hanging heating units, radiators and cupboards etc.
Plywood pattresses can also be secured between studs using ASP19B Service Support Plates.

Ceramic Tiling:

If ceramic tiles are being fixed to the finished wall, to prevent cracking of the tiles, stud centres must be reduced to 400 mm.
Tiles should only be fitted to double layer installations or single layers of 15 mm plasterboard up to a maximum height of
3600 mm.

Mineral Wool Insulation to Metal Stud Partitions and Linings:

Closely butt all joints with no gaps. Unless the insulation is a self-supporting slab type fitted between the studs, fix at head of
frame using long drywall screws or self-adhesive stick pins.

Fire Stopping:

Seal any air gaps at junctions of linings and service penetrations using tightly packed rock mineral wool or fire rated
acoustic mastic to prevent penetration of smoke and flame.

Deflection Heads:

Plasterboards or studs must not be fixed to the head track.


Top fixings must be made through the plasterboard to partition brace which is mounted horizontally approximately 100 mm
from the top of the partition.

Acoustic Sealant:

Seal any air gaps at junctions of linings with walls, floors, ceilings and around openings with a continuous bead of fire rated
acoustic mastic to clean dry dust free surfaces leaving no air gaps.

Moisture Resistance:

Moisture Resistant plasterboard of the specified type to be used in all wet environments or areas of high humidity.

Horizontal Joints:

Partition brace or flat strip must be used behind any horizontal joint in the plasterboard
For double layers, stagger joints between plasterboards by at least 600 mm.
Ensure that all plasterboard edges are supported by the metal framework.

Service Penetrations:

The drylining contractor must liaise with other contractors to ensure that fire resistance and other specific performance
requirements are not impaired by service penetrations.
Form metal framed openings (letterbox) accurately for grouped services and ducts allowing for fire stopping materials.
Provide insulation backing or putty pads to recessed electrical outlets and switches.

Joining of Metal Sections:

To join C Studs splice together with a minimum overlap of 600 mm and secure in both flanges with suitable screws.
To join I Studs butt together and cloak with a short length of deep track approximately 300 mm long and secure to both
flanges using suitable screws.
To join Wall Liner Section WL507 use AWL05 connector.
To join Ceiling Furring MF5 overlap by at least 150 mm and secure to both sides with suitable fixings.
To join Primary Channel MF7 overlap back to back by at least 150 mm and secure with two nuts and bolts.

Page 165 of 168


KS-0247-K - 26/09/2017 Rev L

BS 5234-1:1992
Partition Grades by categories of duty:

Light Duty (LD)


Adjacent space only accessible to persons with high incentive to exercise care. Small chance of accident occurring or of
misuse.
Typical use Domestic accommodation.

Medium Duty (MD)


Adjacent space moderately used, primarily by persons with some incentive to exercise care. Some chance of accident
occurring and of misuse.
Typical use Office accommodation.

Heavy Duty (HD)


Adjacent space frequently used by the public and others with little incentive to exercise care. Chances of accident occurring
and of misuse.
Typical use Public circulation areas & Industrial areas.

Severe Duty (SD)


Adjacent space intensively used by the public and others with little incentive to exercise care. Prone to vandalism and
abnormal rough use.
Typical use Major circulation areas & Heavy industrial areas.

Relevant Standards

Fire
BS 476: 1987
Fire tests on building materials and structures

Part 20
Method for Determination of the fire resistance of elements of construction (general principles)
Part 22
Method of determination of the fire resistance of non-load bearing elements of construction
Part 23
Method for the determination of the contribution of components to the fire resistance of a structure.

BS EN 1364 1 : 1999
Fire tests on building materials and structures

BS EN 1356 2 : 2000
Fire resistance tests for load bearing elements
Part 2 Floors & Ceilings

Acoustics
BS EN ISO 10140-2:2010
Acoustic laboratory tests on elements imperforate partitions.
Mechanical
BS5234 - 2 : 1992
Partitions (including matching linings)

Part 1
Code of practice for design & installation
Part 2
Specification for performance requirements for strength and robustness including methods of test.

Page 166 of 168


KS-0247-K - 26/09/2017 Rev L

Relevant Standards

General
BS EN 14195: 2005
Metal framing components for gypsum plasterboard systems Definitions, requirements and test methods.

BS EN 10143:1993
Specification for continuously hot-dip metal coated steel.

BS EN 10162: 2003
Specification for cold rolled steel sections

BS 1230: 1994
Part 1
Specification for plasterboard excluding materials submitted to secondary operations.

BS8212: 1995
British Standard code of practice for dry lining and partitioning using gypsum plasterboard

BS4787: 1995
Part1
Internal and external wood door sets, door leaves and frames

BS 8290: 1991
Suspended Ceilings

Part 1
Code of practice for design
Part 2
Specification for performance requirements of components and assemblies and methods of test
Part 3
Code of practice for installation and maintenance

BS 8000-8: 1994
Workmanship on building sites

BS EN 520: 2004
Gypsum plasterboards Definitions requirements and test methods

BS 7364: 1990
Galvanised steel studs and channels for stud and sheet partitions and linings using screw fixed gypsum wallboards

Page 167 of 168


KS-0247-K - 26/09/2017 Rev L

Page 168 of 168