Professional Documents
Culture Documents
720-C-003 (LP Methanol Column)
720-C-003 (LP Methanol Column)
S-03848 P58003-T 1
Job No. Doc. No Rev.
Page Item No.
LP methanol column
1 of 7
09-T-0003
Process Specification
for
09-T-0003
LP methanol column
Inlet Streams
Methanol feed inlet
Performance point Design
Temperature 180 F
Pressure 12 psig
Liquid flow 377655 lb/h
Liquid density 46,55 lb/ft
Liquid viscosity 0,283 cP
Liquid surface tension 18,78 dyn/cm
Gas flow 4104 lb/h
Gas density 0,12 lb/ft
Gas viscosity 0,012 cP
Gas molecular weight 31,24 lb/lbmol
Reflux inlet
Performance point Design
Temperature 150 F
Pressure 2 psig
Liquid flow 423140 lb/h
Liquid density 46,79 lb/ft
Liquid viscosity 0,329 cP
Liquid surface tension 18,81 dyn/cm
Outlet Streams
Bottom product outlet
Performance point Design
Temperature 184 F
Liquid flow 162644 lb/h
Liquid density 47,56 lb/ft
Liquid viscosity 0,285 cP
Liquid surface tension 20,79 dyn/cm
OH vapor outlet
Performance point Design
Temperature 155 F
Gas flow 642254 lb/h
Gas density 0,08 lb/ft
Gas viscosity 0,011 cP
Gas molecular weight 32,04 lb/lbmol
Column
Mechanical Design Conditions
Fluid description Methanol/water
Design temperature (min.) 14 F Design pressure (min.) FV psig
Design temperature (max.) 330 F Design pressure (max.) 1) 50 psig
Vessel
Inner diameter 2) 269 246 in Tangent to tangent distance 3) 1846 in
Mounting Skirt Elevation 3) 158 in
Construction code ASME Sec. VIII Stress relieving According to code
Construction material CS Corrosion allowance 0,125 in
Insulation purpose Hot Insulation thickness in
Top head type Ellipsoidal Bottom head type Ellipsoidal
Liquid Levels from Lower Tangent Line
Maximum level 136 in Low level 4 in
High level 12 in Minimum level 0 in
Information contained herein is confidential; it may not be used for any purpose other than for which it has been
issued, and may not be used by or disclosed to third parties without written approval of Haldor Topse A/S.
RESEARCH | TECHNOLOGY | CATALYSTS
Document ID
S-03848 P58003-T 1
Job No. Doc. No Rev.
Page Item No.
LP methanol column
3 of 7
09-T-0003
Trays 1-56
Number of trays 56 Tray numbers 1 - 56
Tray diameter 2) 269 246 in Tray spacing 4) 25 in
Tray type Valve Tray material SS304
Location (from lower TL) in Valve material SS304
Number of passes 2) Double pass Max. downcomer backup %
Approach to flooding (design) 82 % Max. pressure drop per tray 4 in WC
Turndown ratio (design) 50 % System factor 1
Foaming tendency Negligible
Internal Streams
Liquid load
Performance point Design
Temperature 169 F
Liquid flow 428794 lb/h
Liquid density 46,13 lb/ft
Liquid viscosity 0,294 cP
Liquid surface tension 17,87 dyn/cm
Vapor load
Performance point Design
Temperature 155 F
Gas flow 642254 lb/h
Gas density 0,08 lb/ft
Gas viscosity 0,011 cP
Gas molecular weight 30,32 lb/lbmol
Trays 57-62
Number of trays 6 Tray numbers 57 - 62
Tray diameter 2) 269 246 in Tray spacing 4) 25 in
Tray type Valve Tray material SS304
Location (from lower TL) in Valve material SS304
Number of passes 2) Double pass Max. downcomer backup %
Approach to flooding (design) 82 % Max. pressure drop per tray 4 in WC
Turndown ratio (design) 50 % System factor 1
Foaming tendency Negligible
Internal Streams
Liquid load
Performance point Design
Temperature 178 F
Liquid flow 787677 lb/h
Liquid density 46,45 lb/ft
Liquid viscosity 0,286 cP
Liquid surface tension 18,56 dyn/cm
Vapor load
Performance point Design
Temperature 178 F
Gas flow 630932 lb/h
Gas density 0,12 lb/ft
Gas viscosity 0,012 cP
Gas molecular weight 29,72 lb/lbmol
Information contained herein is confidential; it may not be used for any purpose other than for which it has been
issued, and may not be used by or disclosed to third parties without written approval of Haldor Topse A/S.
RESEARCH | TECHNOLOGY | CATALYSTS
Document ID
S-03848 P58003-T 1
Job No. Doc. No Rev.
Page Item No.
LP methanol column
4 of 7
09-T-0003
Remarks
1 Operating pressure of the column at the top is 2.2 psig.
2 ID and number of passes estimated only. Shall be specified by tray vendor.
3 To be confirmed during detailed design.
4 Tray spacings estimated only. Tray spacing is 40" where manholes are located.
5 As indicated in sketch, a separate draw off tray shall be installed in connection with the draw off nozzle B2 to secure
that essentially all liquid passes to the reboiler also during start-up conditions etc., when the vapor rate is low.
6 Tray supplier shall include risers, downcomers and any other associated items as necessary to meet the hydraulics of
the column.
7 Bottom tray may accidentally be exposed to excessive hydraulic pressure from beneath.
8 Estimated weir height is 2". To be confirmed by vendor.
246 269
T.L.
40
13
25
1570
37
1846
49
40
62
60
Maximum level
136
High level
Low level
12
Minimum level
4
T.L.
B1
40
P2 M3 A2
M1 1
O4 41 T4
43
45
47
O5 49 T5
O1 11 T1
51
53
55
56
P3 T6
M4
O6 P1 M2
57 A1
O2 21 T2
60
24
62
M5
B2
P4
O3 31 T3
A3 A4
L5 L3 L1
U
36
M6 Maximum level
High level
Low level
A5
Minimum level
L6 L4 L2 T.L.
B3
Information contained herein is confidential; it may not be used for any purpose other than for which it has been
issued, and may not be used by or disclosed to third parties without written approval of Haldor Topse A/S.
RESEARCH | TECHNOLOGY | CATALYSTS
Document ID
S-03848 P58003-T 1
Job No. Doc. No Rev.
Page Item No.
LP methanol column
7 of 7
09-T-0003
H
09-T-0003
Weir height
52"
52"
10"
10"
36"
18"
36"
09-E-0010 2
18"
20"
36"
09-E-0010 1