PDS For Hot Regenerator - R0.

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
Rev. 0a
rights in relation to patents, utility models and/or other industrial property rights, are reserved.
Lurgi Process DS Cover Sheet.xls

00
Revision

Case-Name:
All
Sheet

Normal Case
Name

Project Name
PuWa
Date
Prepared, Revised
04/10/2015
DiS
Name
Checked
CS
Name

Project No.
Cover
Process

Date
Approved
04/10/2015
Hot Regenerator
06-T-0109
Process Data Sheet

Index of Revisions

IFI
Status

Document No.
Issued for Information

Printed by / date / time:


1 / 13
/
Remark, kind of revision

/
00
Sheet / of Q.L. Revision
CONFIDENTIAL
Process

Process Data Sheet


Column-Reactor Sections

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Designation Hot Regenerator


04
05 Number required 1
06 Orientation vertical
07 Total volume ft
08 Total height ft 204
09
10 Cyclic loading
11 Column Sections
12 Section number Section I Section II Section III
13 Section description HCN Stripping H2S Stripping Water Enrichment
14 Medium
15 Volume ft
16 Height in 534 1312 451
17 Inner diameter in 120.00 177.00 177.00
18 Density lb/ft
19 Op. temp. max. / min. F 155.62 / 147.38 214.64 / 186.44 217.27 / 215.03 /
20 Op. pres. max. / min. psi [a] 49.19 / 47.86 53.52 / 49.53 55.86 / 53.86 /
21 Des temp. max./min./vac. F 345 / 3 / 345 / 3 / 345 / 3 / / /
22 Des pres. max./min./vac. psi[g] 75 / / FV 75 / / FV 75 / / FV / /
23 Corrosive components
24 Sour gas service (acc. Lurgi Std. Spec.) rCAT1 rCAT1 no
25 H 2 -partial pressure psi [a] @ F @ F @ F @ F
26 Material CS CS CS
27 Corrosion allowance in 1/8 1/8 1/8
28 Lining
29 Cladding
30 Heat treatment
31 Process Internals
32 21 / Valve Trays 44 / Valve Trays 10 / Valve Trays /
33 SS Decks: CS Decks: CS
34 Valves: SS Valves: SS
35 / 1 / Chimney Tray / /
36 CS
37
38 / / / /
Internals number / type
39
Material
40
41 / / / /
42
43
44 / / / /
45
46
47 Insulation Yes Heat, external
48 Remarks: row 17) To be finally decided by tray manufacturer / contractor
3
row 18) Only applicable if density > 1000 kg/m (62.43 lb/ft3)
Rows 06) and 18) to be finally decided by tray manufacturer / Vendor

General Notes:
Lurgi Process DS Column-Reactor Sections.xls

1) For Tray design use information provided in "General Notes for column".
2) Refer General Notes for equipments .

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

2 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Nozzle

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Description Hot Regenerator


04
05 Table of Nozzles
06 Item No req NPS Rating Facing Designation
07 in
08 N1 1 2 Methanol outlet to 06-P-0107 A/B
09 N2 1 12 Methanol outlet to 06-E-0119 A
10 N3 1 12 Methanol outlet to 06-E-0119 B
11 N4 1 24 Methanol Vapor inlet from 06-E-0119 A
12 N5 1 24 Methanol Vapor inlet from 06-E-0119 B
13 N6 1 1) Min Flow inlet from 06-P-0107 A/B
14 N7 1 6 Methanol inlet from 06-P-0110 A/B
15 N8 1 24 Methanol outlet to 06-P-0106 A/B/C
16 N9 1 8 Methanol outlet to 06-P-0110 A/B
17 N10 1 1) Min Flow inlet from 06-P-0106 A/B/C
18 N11 1 1) Min Flow inlet from 06-P-0110 A/B
19 N12 A/B 2 10 Methanol Vapor inlet from 06-T-0110
20 N13 A/B 2 20 H2S Laden Methanol in from 06-T-0108
21 N13 C/D 2 20 H2S Laden Methanol in from 06-T-0108
22 N14 A/B 2 16 Methanol vapor inlet to section I from Section II
23 N15 A/B 2 6 H2S Laden Methanol inlet to Section II from Section I
24 N16 A/B 2 4 /3 H2S laden Methanol inlet from 06-T-0112
25 N17 1 3 H2S Laden Methanol in from 06-P-0108 A/B
26 N18 1 24 Acid Gas out to 06-E-0117
27 N19 1 2 Nitrogen Inlet
28 V1 1 2 Vent Section I
29 D1-D2 2 2 Drains
30 P1 1 2 Pressure Transmitter
31 P2 A/B 2 2 Pressure Transmitter
32 L1 A/B 2 2 Level Gauge (Section III)
33 L2 A/B 2 2 Level Transmitter (Section III)
34 L3 A/B 2 2 Level Transmitter (Section III)
35 L4 A/B 2 2 Level Transmitter (Section III)
36 L5 A/B 2 2 Level Gauge (Section II)
37 L6 A/B 2 2 Level Transmitter (Section II)
38 L7 A/B 2 2 Level Transmitter (Section II)
39 L8 A/B 2 2 Level Transmitter (Section II)
40 M1-M9 9 24 Manhole
41 D3 1 4 Drain
42
43
44
45
46
47
48
49
50
51
52
53
54 Remarks: Rating and Facing according pipe-class
1. Nozzle sizes for pump minimum circulation line to be finalised during detailed engineering
2. Inlet nozzle size to be checked by internals vendor.
Lurgi Process DS Nozzle.xls

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

3 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Sketch

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Description Hot Regenerator


04
05 H C N S tr ip p in g S e c tio n I
06 N 18
07 V1
08
09
10 T . L .
11 ID 1 2 0 "
12
13 M9
79 "

14 S e c tio n I
15 N 17
1
T.L.-T.L. 204 '

16
8x20"=160 "

17
18
19
20
9
21
22 N 16 B p lu g - in n o z z le : m a in N o z z le , 6 "
36 "

23 a n d p ip e lin e 4 "
24 10
25
26
27
5X20 " =100 "

28
534 "

29
30
31
32
33
15
34
N 15 B
35
36
M8
59 "

37 N 14 B
38
39 P2B N 16 A p lu g - in n o z z le : m a in N o z z le , 6 "
16 a n d p ip e lin e 4 "
40
41
5X20=100"

42
43
44
45 21
46
47
48
49
50
51 ID 1 7 7"
150 "

52
53
54
55
56
Lurgi Process DS Sketch.xls

57

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

4 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Sketch

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Description Hot Regenerator


04
05 H2 S Stripping Section II
06
07
08
09
2 ) Transition from 1-pass to 4- pass. Liquid
10 discharge from 1-pass side- DC into 4- pass
11 ID 177" false DC.Design by vendor
12
150"

13
Section II
14
15 N13C/D 2) M7
16 22
5x22"=110"

17
18
19
20 27
P2A
21
N14 A
22
79"

23 M6
24 N13 A / B
25 N15A
28
10x22"=220"

26
T.L.-T.L. 204'

27
28
29 38
30
32"

31 M5
32 39
11x22"=242"

33
34
1312"

35
36 50
37
40"

38 M4 N 12 A/B
39 51
14x18"=252"

40
41
42
43 65
44
36"

45 N10
N11
46
L5B,L6B,L7B,L8B
47
299"

48 M3
6 Chimneys in two rows:
49
18" each
50 L5A,L6A,L7A,L8A
51 Vortex Breaker
2"

52
53 N8 N9
54
55 D3 D2
56
Lurgi Process DS Sketch.xls

57

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

5 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Sketch

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Description Hot Regenerator


04
05 W ater E nrichm en t S ection III
06
07 ID 1 77 "
08 6 C him n eys in tw o row
:
09 18 " each
10
11 L5 B,L6 B,L 7B,L8B
299 "

M3
12
13
14 L 5 A,L6 A,L7 A,L8A V ortex B reaker
2"

15
16 N8 N9
17
D3 D2
18 S ection III
19
47 "

M2
20
21
2) Inlet D evice to be de sig n by
22 N7 2) Intern als V endo r / C o ntracto r
23 66
24
9x16"=144 "

25
T.L.-T.L. 204 '

26
27
28 75
451 "

29
30
31
P1
32 N19
33 N6
72 "

34
N4 2)
35 2) N5
36
259"

37 L1 B,L2 B,L3 B,L 4 B


38
39
40
177 "

M1
41
42
43 L 1 A,L2 A,L3 A,L4 A
44 V ortex B rea ker
10"

45
46
47 T.L.
48
N3
min. 1)

49
N2
50
51
N1
52
53 D1
54
55
56 1) H e igh t ab ove ground de pend s on N PS H of P um
, p to be con firm ed ba sed on vendo r in pu t
Lurgi Process DS Sketch.xls

57 data .

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

6 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Sketch

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Description Hot Regenerator


04
05
06 Water Enrichment Section
07
08
and Reboiiler
09
10
11
12
13
14
15
Tray1
16
17
18 N6
51"

19
20
21
22 24" /20" 24" /20"
23 ID177"
24 N5
25 N4
78"

26 06- E- 0119A 06-E-0119B


56"

27
28 64" Section III
29
30
31
32 HLL
33
34
144"

35
36
37
38 NLL
39
116"

40
130"

41
42
43
44
45
46
47
48
49
50
51 N2 N3
52
53
54 N1
55
56
Lurgi Process DS Sketch.xls

57 To06-P-0107A/B

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

7 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Tray

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Designation Hot Regenerator


04
05 Column section number Section I Section I Section I
06 Column section designation HCN Stripping HCN Stripping HCN Stripping
07 Top Middle Middle
08 Tray No. from to 1 9 1 9 10 21
09 Operating data of decisive tray No. 1 9 10
10 Operating pressure psi [a] 47.86 48.53 48.86
11 Medium Acid gas / Methanol Acid gas / Methanol Acid gas / Methanol
12 Operating temperature t op F 152.67 153.75 155.62
Vapour to tray

13 Normal load lb/h 157365 157388 156655


14 Required load min. max. % 39 150 39 150 39 150
15 Molecular weight lb/lbmol 37.49 37.44 37.34
16 Density @ t op lb/ft 0.282 0.283 0.285
17 Dynamic viscosity @ t op cP 0.01 0.01 0.01
18 Compressibility factor Z = pV / RT 0.98 0.98 0.98
19 Medium H2S laden MeOH H2S laden MeOH H2S laden MeOH
F 147.38 153.36 154.34
Liquid from tray

20 Operating temperature
21 Normal load lb/h 47021 47043 73350
22 Required load min. max. % 50 150 50 150 50 150
23 Density @ t op lb/ft 47.12 46.88 46.93
24 Dynamic viscosity @ t op
cP 0.34 0.33 0.33
25 Surface tension dyn/cm 18.73 18.81 19.29
26 Allowable pressure drop per tray psi 0.11 0.11 0.11
27 Allowable level in the downcomer ft
28 Allowable hold-up time in the downcomer min
29 Allowable leakage rate per tray lb/h
30 Allowable flooding factor % 80 80 80
31 Foaming factor (system factor) 1.00 1.00 1.00
32 Column inside calculated in 177.00 177.00 177.00
33 diameter selected in
34 Type of tray Valve Valve Valve
35 Tray spacing in 20.00 20.00 20.00
36 Number of passes 1 1 1
37 Tray SS SS SS
Material

38 Valve
39 Bubble or tunnel caps
40
41 Remarks: row 8, 9) Count from top
row 32, 35) To be stated by tray manufacturer
Internals to be installed into the column/vessel through manhole.
Maximum recommended downcomer inlet velocity: 0.39 ft/s
Maximum recommended downcomer clear liquid backup: 50%, I.e. 0.5 (TS + h_weir)
TS: Tray Spacing
h_weir: Outlet Weir Height

General Notes:
1) Consider fouling service for tray design
Lurgi Process DS Tray.xls

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

8 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Tray

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Designation Hot Regenerator


04
05 Column section number Section I Section II Section II
06 Column section designation HCN Stripping H2S Stripping H2S Stripping
07 Bottom Top Middle
08 Tray No. from to 10 21 22 50 22 50
09 Operating data of decisive tray No. 21 22 50
10 Operating pressure psi [a] 49.19 49.53 51.86
11 Medium Acid gas / Methanol Acid gas / Methanol Acid gas / Methanol
12 Operating temperature t op F 155.32 186.44 213.44
Vapour to tray

13 Normal load lb/h 156978 67551 151825


14 Required load min. max. % 39 150 50 150 50 150
15 Molecular weight lb/lbmol 37.36 33.36 32
16 Density @ t op lb/ft 0.286 0.249 0.242
17 Dynamic viscosity @ t op cP 0.01 0.01 0.01
18 Compressibility factor Z = pV / RT 0.98 0.97 0.95
19 Medium H2S laden MeOH H2S laden MeOH H2S laden MeOH
F 155.62 165.83 212.8
Liquid from tray

20 Operating temperature
21 Normal load lb/h 73673 1379001 1463275
22 Required load min. max. % 50 150 50 110 50 110
23 Density @ t op lb/ft 46.83 46.16 43.48
24 Dynamic viscosity @ t op
cP 0.32 0.31 0.25
25 Surface tension dyn/cm 19.06 17.99 15.76
26 Allowable pressure drop per tray psi 0.11 0.11 0.11
27 Allowable level in the downcomer in
28 Allowable hold-up time in the downcomer min
29 Allowable leakage rate per tray lb/h
30 Allowable flooding factor % 80 80 80
31 Foaming factor (system factor) 1.00 1.00 1.00
32 Column inside calculated in 177.00 177.00 177.00
33 diameter selected in
34 Type of tray Valve Valve Valve
35 Tray spacing in 20.00 22.00 22.00
36 Number of passes 1 4 4
37 Tray SS CS CS
Material

38 Valve SS SS
39 Bubble or tunnel caps
40
41 Remarks: row 8, 9) Count from top
row 32, 35) To be stated by tray manufacturer
Internals to be installed into the column/vessel through manhole.
Maximum recommended downcomer inlet velocity: 0.39 ft/s
Maximum recommended downcomer clear liquid backup: 50%, I.e. 0.5 (TS + h_weir)
TS: Tray Spacing
h_weir: Outlet Weir Height

General Notes:
1) Consider fouling service for tray design
Lurgi Process DS Tray.xls

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

9 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Tray

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Designation Hot Regenerator


04
05 Column section number Section II Section II Section III
06 Column section designation H2S Stripping H2S Stripping Water Enrichment
07 Middle Bottom Top
08 Tray No. from to 51 65 51 65 66 75
09 Operating data of decisive tray No. 50 65 66
10 Operating pressure psi [a] 52.19 53.52 53.86
11 Medium Acid gas / Methanol Acid gas / Methanol Methanol vapour
12 Operating temperature t op F 213.55 214.92 215.43
Vapour to tray

13 Normal load lb/h 99896 103414 103301


14 Required load min. max. % 50 150 50 150 50 150
15 Molecular weight lb/lbmol 32 31.99 31.98
16 Density @ t op lb/ft 0.245 0.249 0.252
17 Dynamic viscosity @ t op cP 0.01 0.01 0.01
18 Compressibility factor Z = pV / RT 0.95 0.95 0.95
19 Medium H2S laden MeOH H2S laden MeOH Methanol vapour
F 213.18 214.64 215.03
Liquid from tray

20 Operating temperature
21 Normal load lb/h 1464192 1467710 110963
22 Required load min. max. % 50 110 50 110 50 150
23 Density @ t op lb/ft 43.46 43.37 43.35
24 Dynamic viscosity @ t op
cP 0.25 0.25 0.25
25 Surface tension dyn/cm 15.76 15.66 15.68
26 Allowable pressure drop per tray psi 0.11 0.11 0.11
27 Allowable level in the downcomer in
28 Allowable hold-up time in the downcomer min
29 Allowable leakage rate per tray lb/h
30 Allowable flooding factor % 80 80 80
31 Foaming factor (system factor) 1.00 1.00 1.00
32 Column inside calculated in 177.00 177.00 177.00
33 diameter selected in
34 Type of tray Valve Valve Valve
35 Tray spacing in 18.00 18.00 16.00
36 Number of passes 4 4 1
37 Tray CS CS CS
Material

38 Valve SS SS SS
39 Bubble or tunnel caps
40
41 Remarks: row 8, 9) Count from
row 32, 35) To be stated by tray manufacturer
Internals to be installed into the column/vessel through manhole.
Maximum recommended downcomer inlet velocity: 0.39 ft/s
Maximum recommended downcomer clear liquid backup: 50%, I.e. 0.5 (TS + h_weir)
TS: Tray Spacing
h_weir: Outlet Weir Height

General Notes:
1) Consider fouling service for tray design
Lurgi Process DS Tray.xls

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

10 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Tray

01 Item Number Unit Number 06


06-T-0109
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in

Rectisol
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

02 Unit Name
rights in relation to patents, utility models and/or other industrial property rights, are reserved.

03 Designation Hot Regenerator


04
05 Column section number Section III
06 Column section designation Water Enrichment
07 Bottom
08 Tray No. from to 66 75
09 Operating data of decisive tray No. 75
10 Operating pressure psi [a] 55.19
11 Medium Methanol vapour
12 Operating temperature t op F 217.27
Vapour to tray

13 Normal load lb/h 205048


14 Required load min. max. % 50 150
15 Molecular weight lb/lbmol 31.77
16 Density @ t op lb/ft 0.254
17 Dynamic viscosity @ t op cP 0.01
18 Compressibility factor Z = pV / RT 0.95
19 Medium Methanol vapour
F 217.18
Liquid from tray

20 Operating temperature
21 Normal load lb/h 212711
22 Required load min. max. % 50 150
23 Density @ t op lb/ft 43.46
24 Dynamic viscosity @ t op
cP 0.25
25 Surface tension dyn/cm 16.67
26 Allowable pressure drop per tray psi 0.11
27 Allowable level in the downcomer in
28 Allowable hold-up time in the downcomer min
29 Allowable leakage rate per tray lb/h
30 Allowable flooding factor % 80
31 Foaming factor (system factor) 1.00
32 Column inside calculated in 177.00
33 diameter selected in
34 Type of tray Valve
35 Tray spacing in 16.00
36 Number of passes 1
37 Tray CS
Material

38 Valve SS
39 Bubble or tunnel caps
40
41 Remarks: row 8, 9) Count from
row 32, 35) To be stated by tray manufacturer
Internals to be installed into the column/vessel through manhole.
Maximum recommended downcomer inlet velocity: 0.39 ft/s
Maximum recommended downcomer clear liquid backup: 50%, I.e. 0.5 (TS + h_weir)
TS: Tray Spacing
h_weir: Outlet Weir Height

General Notes:
1) Consider fouling service for tray design
Lurgi Process DS Tray.xls

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

11 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Nozzle Stream Table

01 Item Number Unit Number 06


02 06-T-0109 Unit Name Rectisol
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

03 Designation Hot Regenerator


rights in relation to patents, utility models and/or other industrial property rights, are reserved.

04
05 Case Normal Case
06 Nozzle-ID N1 N2 / N3 N4 / N5 N7
07 Nozzle designation Methanol outlet to Methanol outlet to Methanol Vapor inlet from Methanol inlet from
08 06-P-0107 A/B 06-E-0119 A / B 06-E-0119 A / B 06-P-0110 A/B
09 Stream no. 400
10 Internal stream no. 400 400A 400B 356
11 Stream designation Methanol / Water MeOH H2O MeOH H2O Lean Methanol to
12 to 06-P-0107 A/B to Reboiler 06-E-0119 from Reboiler 06-E-0119 06-T-0109 (Sec III)
13 Phase Liquid Liquid Mixed Liquid
14 Total flow lbmol/h 242.6 17226.85 17226.85 3475.0
15 Total flow lb/h 7662 544024 544024 111077
16 Liquid Vapour Liquid Vapour Liquid Vapour Liquid Vapour
17 Vol. flow ft/h 176.30 - 12517.81 - 9859.03 - 2562.37 -
18 Norm. vol. flow 10^6 scf/day - - - 31.12 -
19 Mass flow lb/h 7662 544024 436065 107959 111077
20 Mole flow lbmol/h 242.6 17226.85 13808.26 3418.59 3475.0
21 Molweight lb/lbmol 31.58 31.58 31.58 31.58 31.96
22 Eff. density lb/ft 43.46 43.46 44.23 0.27 43.35
23 Spec. heat cap. Btu/(lb F) 0.80 0.80 0.79 0.44 0.79
24 Viscosity cP 0.25 0.25 0.22 0.01 0.25
25 Ther. conductivity (Btu/h)/(ft F) 0.10 0.10 0.10 0.01 0.10
26 Mole fraction fraction 1.00 1.00 0.80 0.20 1.00
27 Mass fraction fraction 1.00 1.00 0.80 0.20 1.00
28 Temperature F 217 217 218 215
29 Pressure psi [a] 55.2 55.2 55.2 70.0
30
31 Nozzle-ID N8 N9 N12 A/B N13 A/B /C/D
32 Nozzle designation Methanol outlet to Methanol outlet to Methanol Vapor inlet from H2S Laden Methanol in
33 06-P-0106 A/B/C 06-P-0110 A/B 06-T-0110 from 06-T-0108
34 Stream no. 403
35 Internal stream no. 340 340A 403 218
36 Stream designation Lean Methanol Methanol outlet to Methanol Water Column H2S Laden Methanol
37 to 06-P-0106 A/B/C 06-P-0110 A/B Ovhd to 06-T-0109 to 06-T-0109
38 Phase Liquid Liquid Vapour Mixed
39 Total flow lbmol/h 41022.76 4894.40 1651.6 42924.1
40 Total flow lb/h 1311263 156446 52845 1394762
41 Liquid Vapour Liquid Vapour Liquid Vapour Liquid Vapour
42 Vol. flow ft/h 30218.66 - 3605.47 - - 27731.53 -
43 Norm. vol. flow 10^6 scf/day - - - 15.0 - 23.4
44 Mass flow lb/h 1311263 156446 52845 1295553 99208
45 Mole flow lbmol/h 41022.76 4894.40 1651.6 40356.3 2567.7
46 Molweight lb/lbmol 31.96 31.96 32.00 32.10 38.64
47 Eff. density lb/ft 43.37 43.37 0.25 46.72 0.39
48 Spec. heat cap. Btu/(lb F) 0.79 0.79 0.39 0.69 0.26
49 Viscosity cP 0.25 0.25 0.01 0.32 0.01
50 Ther. conductivity (Btu/h)/(ft F) 0.10 0.10 0.01 0.10 0.01
51 Mole fraction fraction 1.00 1.00 1.00 0.94 0.06
52 Mass fraction fraction 1.00 1.00 1.00 0.93 0.07
53 Temperature F 215 214.65 215 157
Lurgi Process DS Nozzle Stream Table.xls

54 Pressure psi [a] 53.5 60.48 53.5 65.0


55 Remarks:

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

12 / 13 00
Case-Name: Normal Case Printed by / date / time: / /
Process

Process Data Sheet


Nozzle Stream Table

01 Item Number Unit Number 06


02 06-T-0109 Unit Name Rectisol
writing by Lurgi. Offenders are liable for damages. All rights, including but not limited to all proprietary
or distribution, of this document and its contents are strictly prohibited unless expressly authorized in
Any exploitation and/or other utilization, including but not limited to reproduction, dissemination and/

03 Designation Hot Regenerator


rights in relation to patents, utility models and/or other industrial property rights, are reserved.

04
05 Case Normal Case
06 Nozzle-ID N16 A/B N17 N18
07 Nozzle designation H2S laden Methanol inlet H2S Laden Methanol in Acid Gas out to 06-E-0117
08 from 06-T-0112 from 06-P-0108 A/B
09 Stream no. 376 370
10 Internal stream no. 306 376 370
11 Stream designation Prewash Flashed Hot Regenerator Reflux Hot Regenerator Ovhd
12 Methanol to 06-E-0117
13 Phase Mixed Liquid Vapour
14 Total flow lbmol/h 842.26 1353.94 4087.16
15 Total flow lb/h 27047.68 43732.17 154091.50
16 Liquid Vapour Liquid Vapour Liquid Vapour Liquid Vapour
17 Vol. flow ft/h 511.19 - 846.04 - - -
18 Norm. vol. flow 10^6 scf/day - 0.41 - - 37.22 -
19 Mass flow lb/h 25213.79 1833.89 43732.17 154091.50
20 Mole flow lbmol/h 797.67 44.59 1353.94 4087.16
21 Molweight lb/lbmol 31.61 41.13 32.30 37.70
22 Eff. density lb/ft 49.32 0.44 51.69 0.28
23 Spec. heat cap. Btu/(lb F) 0.65 0.23 0.58 0.26
24 Viscosity cP 0.41 0.01 0.58 0.01
25 Ther. conductivity (Btu/h)/(ft F) 0.10 0.01 0.11 0.01
26 Mole fraction fraction 0.95 0.05 1.00 1.00
27 Mass fraction fraction 0.93 0.07 1.00 1.00
28 Temperature F 109.13 51.51 147.35
29 Pressure psi [a] 64.50 64.50 47.86
30
31 Nozzle-ID
32 Nozzle designation
33
34 Stream no.
35 Internal stream no.
36 Stream designation
37
38 Phase
39 Total flow lbmol/h
40 Total flow lb/h
41 Liquid Vapour Liquid Vapour Liquid Vapour Liquid Vapour
42 Vol. flow ft/h - - - -
43 Norm. vol. flow 10^6 scf/day - - - -
44 Mass flow lb/h
45 Mole flow lbmol/h
46 Molweight lb/lbmol
47 Eff. density lb/ft
48 Spec. heat cap. Btu/(lb F)
49 Viscosity cP
50 Ther. conductivity (Btu/h)/(ft F)
51 Mole fraction fraction
52 Mass fraction fraction
53 Temperature F
Lurgi Process DS Nozzle Stream Table.xls

54 Pressure psi [a]


55 Remarks:

Line revised under Rev. No.

Project Name Project No. Document No. Sheet / of Revision


Rev. 0a

13 / 13 00
Case-Name: Normal Case Printed by / date / time: / /