Detailed Performance Summary For Untitled1

Project: LNG Intl. school 05/02/2017


Prepared By: 10:48AM

Non contractual photo

PackagedChillerReport:DoNotEdit

30XA1312-A Air Cooled Screw Chiller


Cooling Mode Unit Information
Performance Information Manufacturing Source: Montluel, France
Cooling Capacity: 1149.0 kW Refrigerant: R-134a
Cooling Efficiency (EER): 2.25 kW/kW Minimum Capacity: 15 %
Seasonal Efficiency (IPLV.SI): 4.29 kW/kW Number of Refrigerant Circuit: 2
Unit Power Input: 509.73 kW Operating/Shipping Weight: 9441/9258 kg
Evaporator Information Unit Dimensions (LxWxH): 11962/2253/2297 mm
Fluid Type: Fresh Water
Fouling Factor: 0.0176 (sqm-K)/kW MCHE Coating Requirements Information
Number of Passes: 1 Distance from coast (km): 2.0 km
Leaving Temperature: 6.5 C Average Annual Temperature: 46.0 C
Entering Temperature: 12.0 C Average Annual Relative Humidity: 32.0 %
Fluid Flow: 49.78 l/s
Total Pressure Drop: 21.8 kPa Electrical Information
Condenser Information Unit Voltage: 400(+/-10%)-3-50 V-Ph-Hz
Altitude: 0 m Standby Power: 0.24 kW
Number of Fans: 20 Power Factor: 0.88
Entering Air Temperature: 48.0 C
Electrical Electrical
Amps (Un) Circuit 1 Circuit 2
Acoustic Information (cooling mode) Maximum Current In (A): 436 356
Sound Power Level (LwA): 105 dB(A) Start Up Current (A) 629 None
Sound Pressure Level at 5.0m (LpA): 77 dB(A) Current at Eurovent 341 None
Conditions (A)

Accessories and Installed Options


Opt. 119 High Efficiency Option
Opt. 20A IP 54 Protection
Middle East Market Only
Opt. 149 Bacnet over-IP
Opt. 23A Side Panels Only

Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which is based on AHRI Standard
550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.

Packaged Chiller Builder EMEA 3.39c Page 1 of 2


Detailed Performance Summary For Untitled1
Project: LNG Intl. school 05/02/2017
Prepared By: 10:48AM

Integrated Part Load Value (AHRI)


IPLV.SI: 4.29 kW/kW

Unit Performance
Percent Full Load Capacity, % 100 75 50 25
Percent Full Load Power, % 100.0 62.9 34.9 15.5
Unloading Sequence A A A A
Cooling Capacity, kW 1317.1 987.8 658.5 329.3
Unit Power Input, kW 414.5 260.7 144.5 64.4
Efficiency, kW/kW 3.18 3.79 4.56 5.11
Evaporator Data
Fluid Entering Temperature, C 12.0 10.4 9.2 7.9
Fluid Leaving Temperature, C 7.0 7.0 7.0 7.0
Fluid Flow Rate, l/s 62.96 62.96 62.96 62.96
Fouling Factor, (sqm-K)/kW 0.0176 0.0176 0.0176 0.0176
Condenser Data
Entering Air Temperature, C 35.0 27.0 19.0 13.0

Values given are interpolated and are not directly measurable under laboratory conditions.

Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which is based on AHRI Standard
550/590 (I-P) and AHRI Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.

Packaged Chiller Builder EMEA 3.39c Page 2 of 2