Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 5

T 10

T* 5

No. Stream In Stream Out Tin (C) Tout (C) T*in (C) T*out (C)

1 13 15 104 107 109 112

4 4 5 25.1 150 30.1 155

6 7 8 25 90 30 95

Ti (C) Stream Population


Ti (C)
No. 1 4 6
CP 0.028300 0.080283 0.152460
155
1 43
112
1 1 3
109
1 14
95
1 1 64.9
30.1
1 0.1
30

Ti (C) Hot Utility Q (MW) Ti (C) Q (MW)


155 0.000000 155 20.022208
3.452183
112 -3.452183 112 16.570025
0.325749
109 -3.777931 109 16.244277
1.123966
95 -4.901898 95 15.120310
15.105064
30.1 -20.006962 30.1 0.015246
0.015246
30 -20.022208 30 0.000000
0 Cold Utility
Type Hin (MW) Hout (MW) H (MW) CP (MW/C)
Cold -116.2488 -116.1639 0.08490 0.028300

Cold -59.5340 -49.5066 10.02739 0.080283

Cold -593.8639 -583.9539 9.90992 0.152460

CPc - CPh Surplus /


Hi (MW)
(MW/C) Deficit

0.080283 3.4521825 Deficit

0.108583 0.3257489 Deficit

0.080283 1.1239664 Deficit

0.232744 15.1050641 Deficit

0.152460 0.0152460 Deficit

Ti (C) Q (MW)
155.00 20.022208
112.00 16.570025
109.00 16.244277
95.00 15.120310
30.10 0.015246
30 0.000000

180.00

160.00

140.00

120.00

100.00

80.00

60.00

40.00
X Y 20.00
20.022208 155.0
0.00
0 155.0 0.000000 5.000000 10.000000 15.000000 20.000000 25.000000

0.000000 0.0
0 0.0
0000 20.000000 25.000000

You might also like