Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Noise Control Services

Impedance and Transmission Tube Suite


Follows ISO 10534-2, ASTM E1050,
and ASTM E2611 (using 3 or 4 microphones methods)

Overview

Mecanums tube suite differentiates itself from the competition


by its quality and by the service that comes with it.
It can characterize a wide range of materials from simple foams
to complex multilayers including resistive screen sand fabrics.
Mecanums tube suite complies with ISO 10534-2 and ASTM
E1050 for sound absorption, and with ASTM E2611 for
transmission loss measurements.

Features
Standard Mecanum's tube suite includes:
Acoustic tube 44.5 mm [50-4100 Hz] frequency range (Default size):
o 29 mm [500-6000 Hz] frequency range (optional);
o 100 mm [50-1800 Hz] frequency range (optional);
o Custom shape and dimension (optional)
2 microphones for impedance tube suite only;
3 or 4 microphones for impedance/transmission suite tube;
DAQ system with ultra-low distortion audio amplifier;
Tube-X software, automatically communicates with the DAQ (plug & play system);
Verification sample used to check the measurement procedure;
Mounting rings to improve sample position in the tube and avoid acoustic leak;
Mounting grid to test limp materials at a fixed thickness;
Data exports to Microsoft Excel format.
Measured normal incidence properties 2-mic 3 or 4-mic
Sound absorption coefficient
Complex reflection coefficient
Specific surface impedance
Characteristic acoustic impedance
Complex wave number
Equivalent fluid dynamic density
Equivalent fluid dynamic bulk modulus
Transfer matrix coefficients (4-pole)

Tube-X software fully controls the measurement procedure from the calibration to the
measurement itself. It corrects for atmospheric conditions and tube's internal dissipation,
and automatically controls the sound level inside the tube.
The 3 microphones method, only offered by Mecanum, provides more accuracy and precision than the 4
microphones method, with quicker and simpler measurements.
J. Acoust. Soc. Am. 131, EL216 (2012); http://dx.doi.org/10.1121/1.3681016

Mecanum Inc. (819) 563-3317 (819) 563-0649


3523, Alfred-Desrochers info@mecanum.com
Sherbrooke QC J1K 0A2 Canada www.mecanum.com
Noise Control Services

Add-ons & Complements


Mecanums tube suite is a very powerful tool for any acoustic lab, especially when combined with Mecanum accessories and
simulation software.

Resistive screen and fabric holder


These accessories will improve the measurement for thin material that do not have enough mechanical strength to
hold in place in the tube. They will also minimize acoustical leaks around samples.
Foam-X software
Based on the sound absorption coefficient measured in impedance tube
(ASTM E1050, ISO 10534-2), Foam-X computes all the acoustic parameters
you need to model a single or an equivalent acoustic material.

Nova software
Nova predicts sound absorption and transmission loss (and more) of single
or multilayer materials. Simulation is based on the acoustic parameters you
determined with FoamX or direct characterisation apparatuses such as a
airflow resistance meter (SIGMA), a porosity meter (PHI), a tortuosity meter
(TOR), and a mechanical analyzer (QMA).

Technical Data
Tube Instrumentation Software
Tube internal diameter: 29, 44.5 or 100 mm DAQ Version: Tube-X 2013
Maximum samples length: 160 mm Type: USB controlled DAQ Minimum operating system: Windows 2003, XP,
Nominal dimensions: small tube: 60 x 20 x 20 cm (opt.) Input: 4 channels 100 kHs/ch 24 bit Vista, 7,8
med. tube: 60 x 20 x 20 cm Output: 1 channel 96 kHz/ch 24 bit Results file format: Excel file
large tube: 90 x 20 x 20 cm (opt.) Power supply: USB port
Weight: small tube: 3.5 kg (opt.) Amplifier
med. tube: 4 kg Type: Class T digital audio amplifier
large tube: 6 kg (opt.) Power supply: 110-240 Vac 50/60Hz
Material: CNC machined Aluminum Microphones
Support: Plexiglas support included for each tube Type: BSWA pressure type microphones
Number: 2 to 4
Frequency Response: 20~20kHz

Warranty & Support


Because Mecanum clients expect nothing but first quality instrumentation, all our characterization systems are
covered by a 1-year limited warranty1. Technical support is also provided for the whole of this period. Instrumentation
is covered by there manufacturers original warranty.
1 Mecanum Warranty is only valid on manufacturing defects and will not cover damage due to any abusive or improper use.

Mecanum Inc. (819) 346-5666 (819) 563-0649


3523, Alfred-Desrochers info@mecanum.com
Sherbrooke QC J1K 0A2 Canada www.mecanum.com