Professional Documents
Culture Documents
Supply Air Diffuser Selection - Telecom Room at Upstream Building
Supply Air Diffuser Selection - Telecom Room at Upstream Building
Supply Air Diffuser Selection - Telecom Room at Upstream Building
air master
Chapter 7
INDEX
A. Linear slot diffusers:
1. Supply linear slot diffusers ...........:ASLD...........7.1
2. Return linear slot diffusers............:ARLD...........7.2
3. Curved supply linear slot diffusers ..:ASLD (C).......7.3
Construction:
Frame & Blades: High quality extruded alumini-
um profiles.
Damper: Hit and miss damper.
Slot width: 20 mm as standard. 16 mm, 25 mm
and non standard sizes available as option.
Number of slots available: 1,2,3,4,5,6,7,8
1.5 mt.
Length: Up to 5.8 mt available in a single piece.
Optional accessories: Plenum box either
unlined, internally insulated or externally insulated.
Foam gasket is sealed around the back of the
Description: frame as option to avoid air leakage.
Frame and deflection blades are made of high
quality extruded aluminium profiled construction Suitable for installation for ceiling and sills.
with the advantages of corrosion resistance and
rigidity. Standard finishes:
Natural anodized aluminium finish.
Air distribution can be changed vertically or hor-
Powder coated colour finish as per RAL colour
izontally by means of deflection blades with out
code.
changing the air flow rate. These blades can be
Flexibility of finish available.
fully adjusted from face opening.
7.1
ISO 9002 certified company
Linear Slot Diffusers
Construction:
Frame and blades: High quality extruded alu-
minium profiles.
Optional Damper: Hit and miss damper.
Slot width: 20 mm as standard. 16 mm, 25 mm
and non standard sizes available as option.
Number of slots available: 1,2,3,4,5,6,7,8.
Length: Upto 5.8 mt available in a single piece.
Optional accessories: Plenum box either
unlined, internally insulated or externally insulat- Foam gasket is sealed around the back of the
ed. frame as option to avoid air leakage.
Construction:
Frame & Blades: High quality extruded alumini-
um profiles.
Damper: Hit and miss damper.
Slot width: 20 mm as standard. 16 mm, 25 mm
and non standard sizes available as option.
Number of slots available: 1,2,3,4,5,6,7,8
Length: Up to 3 meters are available in a single
piece.
Description:
Frame and deflection blades are made of high Model: ARLD(C): Same as ASLD(C), without hit
quality extruded aluminium profiled construction and miss damper.
with the advantages of corrosion resistance and
rigidity. Standard finishes:
Natural anodized aluminium finish.
Hit and miss damper will be fixed rigidly at the Powder coated colour finish as per RAL colour
rear side of the diffuser as option. code.
Flexibility of finish available.
Positive alignment of adjacent sections can be
made by using alignment strips.
7.3
ISO 9002 certified company
Linear Slot Diffusers
16 mm slot opening
No of slots 1 2 3 4 5 6 7 8
N=Neck size in mm 38 68 98 128 158 188 218 248
Duct size in mm 48 78 108 138 168 198 228 258
A in mm 31 61 91 121 151 181 211 241
B in mm 79 109 139 169 199 229 259 289
False ceiling opening size 59 89 119 149 179 209 239 269
20 mm slot opening
No of slots 1 2 3 4 5 6 7 8
N=Neck size in mm 42 76 110 144 178 212 246 280
Duct size in mm 52 86 120 154 188 222 256 290
A in mm 35 69 103 137 171 205 239 273
B in mm 83 117 151 185 219 253 287 321
False ceiling opening size 63 97 131 165 199 233 267 301
No of slots 1 2 3 4 5 6 7 8
N=Neck size in mm 47 86 125 164 203 242 281 320
Duct size in mm 57 96 136 174 213 252 291 330
A in mm 40 79 118 157 196 235 274 313
B in mm 88 127 166 205 244 283 322 361
False ceiling opening size 68 107 146 185 224 263 302 341
7.4
ISO 9002 certified company
Linear Slot Diffusers
air master
7 a. 90 Mitred corner
7.5
ISO 9002 certified company
Linear Slot Diffusers
air master
Optional profiles
Fixing details
C-Clamp fixing:
7.6
ISO 9002 certified company
Linear Slot Diffusers
air master
Flange models:
How to order:
Optional
Model No of slots Length End flange details Qty Finish
Slot width
1 5 A). With open ends A). Natural anodized
16 mm 6 No.
ASLD Aluminium finish
2 6 1.5 mt. B). One side end flange
Specify
Specify in
25 mm in B). RAL 9010
3 7 meters C). One side end cap
numbers
ARLD
Other size With both sides C). Other colours
4 8
D). Flange (or) E) caps
Ordering example:
To select supply linear slot diffuser, 4 slots with a slot width of 20 mm of length 2.5 meters with open
ends. Quantity 50 numbers with RAL9010 colour finish.
Order as : ASLD-4-2.5- A -50-B.
ASLD-25-8-1.5-D-6-C
Data based on one meter length of the diffuser with damper fully opened.
Face velocity is measured in m/sec.
Ps: Static pressure loss is in mm of H2O. Area factor in square meters.
Throw (meters) is measured for a terminal velocities of 0.25, 0.5 and 0.75 m/sec.
NC based on a room attenuation of 10 dB.
Above data is tested & certified by ETL.
7.8
ISO 9002 certified company
Linear Slot Diffusers
Data based on one meter length of the diffuser with damper fully opened.
Face velocity is measured in m/sec.
Ps: Static pressure loss is in mm of H2O. Area factor in square meters.
Throw (meters) is measured for a terminal velocities of 0.25, 0.5 and 0.75 m/sec.
NC based on a room attenuation of 10 dB.
Above data is tested & certified by ETL.
7.9
ISO 9002 certified company
Linear Slot Diffusers
Data based on one meter length of the diffuser with damper fully opened.
Face velocity is measured in m/sec.
Ps: Static pressure loss is in mm of H2O. Area factor in square meters.
Throw (meters) is measured for a terminal velocities of 0.25, 0.5 and 0.75 m/sec.
NC based on a room attenuation of 10 dB.
Above data is tested & certified by ETL.
7.10
ISO 9002 certified company
Linear Slot Diffusers
Data based on one meter length of the diffuser with damper fully opened.
Face velocity is measured in m/sec.
Ps: Static pressure loss is in mm of H2O. Area factor in square meters.
Throw (meters) is measured for a terminal velocities of 0.25, 0.5 and 0.75 m/sec.
NC based on a room attenuation of 10 dB.
Above data is tested & certified by ETL.
7.11
ISO 9002 certified company
Linear Slot Diffusers
Data based on one meter length of the diffuser with damper fully opened.
Face velocity is measured in m/sec.
Ps: Static pressure loss is in mm of H2O. Area factor in square meters.
Throw (meters) is measured for a terminal velocities of 0.25, 0.5 and 0.75 m/sec.
NC based on a room attenuation of 10 dB.
Above data is tested & certified by ETL.
7.12
ISO 9002 certified company
Linear Slot Diffusers
Data based on one meter length of the diffuser with damper fully opened.
Face velocity is measured in m/sec.
Ps: Static pressure loss is in mm of H2O. Area factor in square meters.
Throw (meters) is measured for a terminal velocities of 0.25, 0.5 and 0.75 m/sec.
NC based on a room attenuation of 10 dB.
Above data is tested & certified by ETL.
7.13
ISO 9002 certified company
Linear Slot Diffusers
7.14
ISO 9002 certified company
Linear Slot Diffusers
7.15
ISO 9002 certified company
Linear Slot Diffusers
7.16
ISO 9002 certified company