Design Calculation For Wall
Design Calculation For Wall
Design Calculation For Wall
Reference Code: IS: 875 Part 1 & 2 for Dead Load and Live Load on the structures
IS: 875 Part 3 for Wind Load Calculation
IS:800
Design Consideration :
The Structure is temporary structure with structural steel framing and RCC block foundation.
3 sp @ 5.0 m = 15.0 m
2 sp @ 6.0 m = 12 m
X
Axis of reference
Vz = Vb x K1 x K2 X k3
= 44 x0.71 x 1 x 1
= 31.24 m/s
1
Pressure, Pz = 0.6 x Vz^2
2
= 59.71 kg/m
2
Design Pressure, Pd = Pz x Kd x Ka = 53.739 kg/m
This pressure shall be reduced by 20% as the height of wall is less than 10 m
2
Hence Pd = 43 kg/m
b= 15 m
h = 8.2 m
b= 15 m
h= 8.2 m
b/h = 1.83
WL in X direction: WL X
WL on col = 43 x 1.2 x 6 x1
= 309.6 kg/m
= 0.310 t/m
WL in Z direction: WL Z