This heat exchanger specification sheet provides details for a shell and tube heat exchanger with one shell and four tube passes. It will transfer heat between kerosene and crude oil, lowering the kerosene temperature from 25°C to 66°C and the crude oil from 114°C to 66°C, exchanging over 4,500 kW of thermal energy. The key components include a single segmented baffle with 25% cut and 207.2mm spacing, 5000mm long tubes made of steel in a 25mm pitch pattern, and meets TEMA class requirements.
Original Description:
TEMA Heat Exchanger blank sheet for STHE specification
This heat exchanger specification sheet provides details for a shell and tube heat exchanger with one shell and four tube passes. It will transfer heat between kerosene and crude oil, lowering the kerosene temperature from 25°C to 66°C and the crude oil from 114°C to 66°C, exchanging over 4,500 kW of thermal energy. The key components include a single segmented baffle with 25% cut and 207.2mm spacing, 5000mm long tubes made of steel in a 25mm pitch pattern, and meets TEMA class requirements.
This heat exchanger specification sheet provides details for a shell and tube heat exchanger with one shell and four tube passes. It will transfer heat between kerosene and crude oil, lowering the kerosene temperature from 25°C to 66°C and the crude oil from 114°C to 66°C, exchanging over 4,500 kW of thermal energy. The key components include a single segmented baffle with 25% cut and 207.2mm spacing, 5000mm long tubes made of steel in a 25mm pitch pattern, and meets TEMA class requirements.
1 Company: Chemical Engineering University of Sriwijaya 2 Service Of Unit: Our Reference : 3 Item No.: 5 Your Reference:Coulson and Richardson 4 Date: May 06th 2017 Rev No.: 1 Job No.: 1 5 Size / m Type BEM hor Connected in 1parallel 1series 6 Surf/unit(eff.) 303,851 m2 Shells/unit 1 Surf/shell (eff.) m2 7 PERFORMANCE OF ONE UNIT 8 Fluid allocation Shell Side Tube Side 9 Fluid name Kerosene Crude Oil 10 Fluid quantity, Total Kg/h 191160 156960 11 Vapor (In/Out) Kg/h - - - - 12 Liquid Kg/h 191160 156960 13 Noncondensable - - 14 15 Temperature (In/Out) C 25 66 114 66 16 Dew / Bubble point C 17 Density Kg/m3 823 790 810 839 18 Viscosity Ns/m2 0,0024 0,00128 0,00108 0,00225 19 Molecular wt, Vap 20 Molecular wt, NC 255 537 21 Specific heat kJ/KgoC 1,989 2,1771 2,26 2,0725 22 Thermal conductivity W/m K 0,141 0,139 0,1255 0,1289 23 Latent heat J/KgoC - - - - 24 Pressure KPa 1,0125 1,0125 1,0125 1,0125 25 Velocity m/s 0,4426 1,1995 26 Pressure drop, allow./calc. psi <10 6,057 <10 0,826 27 Fouling resist. (min) m2 oC/W 0,0002 0,0002 28 Heat exchanged W 4512,49536 MTD corrected 97 C 29 Transfer rate, Service Dirty Clean 30 CONSTRUCTION OF ONE SHELL Sketch 31 Shell Side Tube Side 32 Design/Test pressure psi / / 33 Design temperature C 34 Number passes per shell 1 4 35 Corrosion allowance mm 36 Connections In / / 37 Size/rating Out / / 38 in Intermediate / / 39 Tube No. OD 30 Tks-avg mm Length 5000 mm Pitch 25 mm 40 Tube type Plain Material Steel Tube pattern 41 Shell ID OD mm Shell cover 42 Channel or bonnet Channel cover 43 Tubesheet-stationary Tubesheet-floating 44 Floating head cover Impingement protection 45 Baffle-crossing Type single seg Cut(%d)25 hor Spacing: c/c 207,20 mm Split Ring 46 Baffle-long 5000 mm Seal type Floating Heat Inlet Mm 47 Supports-tube Split Ring Type 48 Bypass seal Tube-tubesheet joint Expand 49 Expansion joint Type Kg/(mm 50 RhoV2-Inlet nozzle Bundle entrance Bundle exit s2) 51 Gaskets - Shell side Tube Side 52 Floating head 53 Code requirements TEMA class 54 Weight/Shell Filled with water Bundle Kg 55 Remarks 56 57