INTRODUCTION
Renewable energy is the energy which comes from natural resources such as sunlight, wind, rain,
tides and geothermal heat. These resources are renewable and can be naturally replenished.
Therefore, for all practical purposes, these resources can be considered to be inexhaustible,
unlike dwindling conventional fossil fuels. The global energy crunch has provided a renewed
impetus to the growth and development of Clean and Renewable Energy sources. Clean
Development Mechanisms (CDMs) are being adopted by organizations all across the globe.
Apart from the rapidly decreasing reserves of fossil fuels in the world, another major factor
working against fossil fuels is the pollution associated with their combustion. Contrastingly,
renewable energy sources are known to be much cleaner and produce energy without the harmful
Wind turbines can be used to harness the energy available in airflows. Current day turbines range
from around 600 kW to 5 MW of rated power. Since the power output is a function of the cube
of the wind speed, it increases rapidly with an increase in available wind velocity. Recent
advancements have led to aerofoil wind turbines, which are more efficient due to a better
aerodynamic structure.
1
1.2.2 Small Hydropower
renewable energy sources. These involve converting the potential energy of water stored in dams
into usable electrical energy through the use of water turbines. Run-of-the-river hydroelectricity
aims to utilize the kinetic energy of water without the need of building reservoirs or dams.
1.2.3 Biomass
Plants capture the energy of the sun through the process of photosynthesis. On combustion, these
plants release the trapped energy. This way, biomass works as a natural battery to store the suns
1.2.4 Geothermal
Geothermal energy is the thermal energy which is generated and stored within the layers of the
Earth. The gradient thus developed gives rise to a continuous conduction of heat from the core to
the surface of the earth. This gradient can be utilized to heat water to produce superheated steam
and use it to run steam turbines to generate electricity. The main disadvantage of
geothermal energy is that it is usually limited to regions near tectonic plate boundaries, though
The tapping of solar energy owes its origins to the British astronomer John Herschel who
famously used a solar thermal collector box to cook food during an expedition to Africa.
Solar energy is one of the most important renewable energy sources that have been gaining
increased attention in recent years. Solar energy is plentiful; it has the greatest availability
compared to other energy sources. The amount of energy supplied to the earth in one day by the
2
Sun is sufficient to power the total energy needs of the earth for one year. Solar energy is clean
and free of emissions, since it does not produce pollutants or by-products harmful to nature. The
conversion of solar energy into electrical energy has many application fields.
Solar to electrical energy conversion can be done in two ways: solar thermal and solar
photovoltaic. Solar thermal is similar to conventional AC electricity generation by steam turbine
excepting that instead of fossil fuel; heat extracted from concentrated solar ray is used to produce
steam and apart is stored in thermally insulated tanks for using during intermittency of sunshine
or night time. Solar photovoltaic use cells made of silicon or certain types of semiconductor
materials which convert the light energy absorbed from incident sunshine into DC electricity. To
make up for intermittency and night time storage of the generated electricity into battery is
needed.
Recently, research and development of low cost flat-panel solar panels, thin-film devices,
concentrator systems, and many innovative concepts have increased. In the near future, the costs
of small solar-power modular units and solar-power plants will be economically feasible for
large-scale production and use of solar energy.
The current trend across developed economies tips the scale in favour of Renewable Energy. For
the last three years, the continents of North America and Europe have embraced more renewable
power capacity as compared to conventional power capacity. Renewables accounted for 62% of
the newly installed power capacity in Europe in 2014 and nearly 30% of the annual power
production.
3
Figure 1: Global energy consumption in the year 2014
As can be seen from the figure, wind and biomass occupy a major share of the current renewable
incubation of projects in countries like Germany and Spain have brought around tremendous
growth in the solar PV market as well, which is projected to surpass other renewable energy
By 2011, more than 119 countries had some policy target to achieve a predetermined share of
their power capacity through renewables. This was an increase from around 22 countries in 2009.
Most of the targets are also very ambitious, landing in the range of 30-90% share of national
production through renewables. Noteworthy policies are the European Unions target of
achieving 20% of total energy through renewables by 2020 and Indias Jawaharlal Nehru Solar
Mission, through which India plans to produce 20GW solar energy by the year 2022.
4
2. Literature Review
Studies show that a solar panel converts 30-40% of energy incident on it to electrical energy. A
Maximum Power Point Tracking algorithm is necessary to increase the efficiency of the solar
panel.
There are different techniques for MPPT such as Perturb and Observe (hill climbing method),
Incremental conductance, Fractional Short Circuit Current, Fractional Open Circuit Voltage,
Fuzzy Control, Neural Network Control etc. Among all the methods Perturb and observe (P&O)
and Incremental conductance are most commonly used because of their simple implementation,
lesser time to track the MPP and several other economic reasons.
Under abruptly changing weather conditions (irradiance level) as MPP changes continuously,
P&O takes it as a change in MPP due to perturbation rather than that of irradiance and
sometimes ends up in calculating wrong MPP. However this problem gets avoided in
Incremental Conductance method as the algorithm takes two samples of voltage and current to
calculate MPP. However, instead of higher efficiency the complexity of the algorithm is very
high compared to the previous one and hence the cost of implementation increases. So we have
to mitigate with a trade off between complexity and efficiency. It is seen that the efficiency of
the system also depends upon the converter. Typically it is maximum for a buck topology, then
When multiple solar modules are connected in parallel, another analog technique TEODI is also
very effective which operates on the principle of equalization of output operating points in
correspondence to force displacement of input operating points of the identical operating system.
It is very simple to implement and has high efficiency both under stationary and time varying
Atmospheric conditions
5
3. Standalone Photovoltaic System Components
A photovoltaic cell or photoelectric cell is a semiconductor device that converts light to electrical
energy by photovoltaic effect. If the energy of photon of light is greater than the band gap then
channel of the semiconductor junction and gets converted into current or voltage signal but a
3.2 PV Module
Usually a number of PV modules are arranged in series and parallel to meet the energy
requirements. PV modules of different sizes are commercially available (generally sized from
60W to 170W). For example, a typical small scale desalination plant requires a few thousand
watts of power.
3.3 PV Modelling
A PV array consists of several photovoltaic cells in series and parallel connections. Series
connections are responsible for increasing the voltage of the module whereas the parallel
Typically a solar cell can be modelled by a current source and an inverted diode connected in
parallel to it. It has its own series and parallel resistance. Series resistance is due to hindrance in
the path of flow of electrons from n to p junction and parallel resistance is due to the leakage
current.
6
Figure 3.1 : Single diode model of a PV cell
In this model we consider a current source (I) along with a diode and series resistance (Rs). The
shunt resistance (RSH) in parallel is very high, has a negligible effect and can be neglected.
I=Isc Id (3.1)
where Io is the reverse saturation current of the diode, q is the electron charge, Vd is the voltage
across the diode, k is Boltzmann constant (1.38 * 10-19 J/K) and T is the junction temperature in
Kelvin (K)
7
Using suitable approximations,
where, I is the photovoltaic cell current, V is the PV cell voltage, T is the temperature (in Kelvin)
In order to model the solar panel accurately we can use two diode model but in our project
our scope of study is limited to the single diode model. Also, the shunt resistance is very high
8
The I-V characteristics of a typical solar cell are as shown in the Figure 3.2.
When the voltage and the current characteristics are multiplied we get the P-V characteristics as
shown in Figure 3.3. The point indicated as MPP is the point at which the panel power output is
maximum.
9
3.4 Boost Converter
As stated in the introduction, the maximum power point tracking is basically a load matching
problem. In order to change the input resistance of the panel to match the load resistance (by
It has been studied that the efficiency of the DC to DC converter is maximum for a buck
converter, then for a buck-boost converter and minimum for a boost converter but as we intend
to use our system either for tying to a grid or for a water pumping system which requires 230 V
10
Mode 1 operation of the Boost Converter
When the switch is closed the inductor gets charged through the battery and stores the energy. In
this mode inductor current rises (exponentially) but for simplicity we assume that the charging
and the discharging of the inductor are linear. The diode blocks the current flowing and so the
load current remains constant which is being supplied due to the discharging of the capacitor.
11
Mode 2 operation of the Boost Converter
In mode 2 the switch is open and so the diode becomes short circuited. The energy stored in the
inductor gets discharged through opposite polarities which charge the capacitor. The load current
remains constant throughout the operation. The waveforms for a boost converter are shown in
Figure 3.7.
12
Figure 3.7: Waveforms for a Boost Converter
13
4. Maximum Power Point Tracking Algorithms
A typical solar panel converts only 30 to 40 percent of the incident solar irradiation into
electrical energy. Maximum power point tracking technique is used to improve the efficiency of
According to Maximum Power Transfer theorem, the power output of a circuit is maximum
when the Thevenin impedance of the circuit (source impedance) matches with the load
impedance. Hence our problem of tracking the maximum power point reduces to an impedance
matching problem.
In the source side we are using a boost convertor connected to a solar panel in order to enhance
the output voltage so that it can be used for different applications like motor load. By changing
the duty cycle of the boost converter appropriately we can match the source impedance with that
There are different techniques used to track the maximum power point. Few of the most popular
techniques are:
14
The choice of the algorithm depends on the time complexity the algorithm takes to track the
Perturb & Observe (P&O) is the simplest method. In this we use only one sensor, that is the
voltage sensor, to sense the PV array voltage and so the cost of implementation is less and hence
easy to implement. The time complexity of this algorithm is very less but on reaching very close
to the MPP it doesnt stop at the MPP and keeps on perturbing on both the directions. When this
happens the algorithm has reached very close to the MPP and we can set an appropriate error
limit or can use a wait function which ends up increasing the time complexity of the algorithm.
However the method does not take account of the rapid change of irradiation level (due to which
MPPT changes) and considers it as a change in MPP due to perturbation and ends up calculating
the wrong MPP. To avoid this problem we can use incremental conductance method.
Incremental conductance method uses two voltage and current sensors to sense the output
(dP/dV)MPP=d(VI)/dV (4.1)
0=I+VdI/dVMPP (4.2)
15
The left hand side is the instantaneous conductance of the solar panel. When this instantaneous
Here we are sensing both the voltage and current simultaneously. Hence the error due to change
in irradiance is eliminated. However the complexity and the cost of implementation increases.
As we go down the list of algorithms the complexity and the cost of implementation goes on
increasing which may be suitable for a highly complicated system. This is the reason that Perturb
and Observe and Incremental Conductance method are the most widely used algorithms.
Owing to its simplicity of implementation we have chosen the Perturb & Observe algorithm for
The near linear relationship between VMPP and VOC of the PV array, under varying irradiance and
array being used, it usually has to be computed beforehand by empirically determining V MPP and
VOC for the specific PV array at different irradiance and temperature levels. The factor k1 has
been reported to be between 0.71 and 0.78. Once k1 is known, VMPP can be computed with VOC
measured periodically by momentarily shutting down the power converter. However, this incurs
16
4.2.4 Fractional short circuit current
Fractional ISC results from the fact that, under varying atmospheric conditions, IMPP is
I =k I
MPP 2 sc (4.5)
where k2 is a proportionality constant. Just like in the fractional VOC technique, k2 has to be
determined according to the PV array in use. The constant k2 is generally found to be between
0.78 and 0.92. Measuring ISC during operation is problematic. An additional switch usually has
to be added to the power converter to periodically short the PV array so that ISC can be
Microcontrollers have made using fuzzy logic control popular for MPPT over last decade. Fuzzy
logic controllers have the advantages of working with imprecise inputs, not needing an accurate
Another technique of implementing MPPT which are also well adapted for microcontrollers is
neural networks. Neural networks commonly have three layers: input, hidden, and output layers.
The number nodes in each layer vary and are user-dependent. The input variables can be PV
array parameters like VOC and ISC, atmospheric data like irradiance and temperature, or any
combination of these. The output is usually one or several reference signals like a duty cycle
signal used to drive the power converter to operate at or close to the MPP .
17
Table 1 : Characteristics of different MPPT techniques
conductance
18
4.3 Perturb & Observe Algorithm
The Perturb & Observe algorithm states that when the operating voltage of the PV panel is
perturbed by a small increment, if the resulting change in power P is positive, then we are going
in the direction of MPP and we keep on perturbing in the same direction. If P is negative, we are
going away from the direction of MPP and the sign of perturbation supplied has to be changed.
Figure 4.1: Solar panel characteristics showing MPP and operating points A and B [16]
Figure 4.1 shows the plot of module output power versus module voltage for a solar panel at a
given irradiation. The point marked as MPP is the Maximum Power Point, the theoretical
maximum output obtainable from the PV panel. Consider A and B as two operating points. As
19
shown in the figure above, the point A is on the left hand side of the MPP. Therefore, we can
move towards the MPP by providing a positive perturbation to the voltage. On the other hand,
point B is on the right hand side of the MPP. When we give a positive perturbation, the value of
MPP. The flowchart for the P&O algorithm is shown in Figure 4.2.
20
4.4 Limitations of Perturb & Observe algorithm
Figure 4.3: Curve showing wrong tracking of MPP by P&O algorithm under
In a situation where the irradiance changes rapidly, the MPP also moves on the right hand side of
the curve. The algorithm takes it as a change due to perturbation and in the next iteration it
changes the direction of perturbation and hence goes away from the MPP as shown in the figure.
However, in this algorithm we use only one sensor, that is the voltage sensor, to sense the PV
array voltage and so the cost of implementation is less and hence easy to implement. The time
complexity of this algorithm is very less but on reaching very close to the MPP it doesnt stop at
the MPP and keeps on perturbing in both the directions. When this happens the algorithm has
reached very close to the MPP and we can set an appropriate error limit or can use a wait
21
5. Modeling of standalone PV system
5.1 Introduction
Among the renewable energy resources, the energy due to the photovoltaic (PV) effect
can be considered the most essential and prerequisite sustainable resource because of the
The current source Iph represents the cell photocurrent. Rsh and Rs are the intrinsic
shunt and series resistances of the cell, respectively. Usually the value of Rsh is very large
and that of Rs is very small, hence they may be neglected to simplify the analysis.
PV cells are grouped in larger units called PV modules which are further
interconnected in a parallel-series configuration to form PV arrays.
22
5.2 Solar panel
The entire system has been modeled on MATLAB 2015a and Simulink. The block diagram
of the solar PV panel is shown in Figure 5.1 and Figure 5.2. The inputs to the solar PV panel are
temperature, solar irradiation, number of solar cells in series and number of rows of solar cells in
parallel.
23
Figure 5.3: Unmasked block diagram of the modeled solar PV panel
The simulation is carried out for a cell surface temperature of 28 C, 60 solar cells in series and 4
rows of solar cells in parallel. The irradiation (shown in Figure 5.3) is taken to be varying, to
reflect real life conditions and effectively show the use of an MPPT algorithm in field runs. It
varies from 60 Watt per sq. cm. to 85 Watt per sq. cm, which is close to the day values of solar
radiation received on the earths surface. The simulation is run for a total of 0.12 seconds, with
the irradiation taking up a new value every 0.03 seconds and staying constant for the consequent
0.03 seconds.
24
5.3 MPPT Interfacing
The controlled voltage source and the current source inverter have been used to interface the
modeled panel with the rest of the system and the boost converter which are built using the
SimPowerSystems module of MATLAB. The block diagram for the model shown in Figure 5.4
is a simulation for the case where we obtain a varying voltage output. This model is used to
highlight the difference between the power obtained on using an MPPT algorithm and the power
To compare the power output in both the cases stated above, the model is equipped with a
manual switch as shown. When the switch is thrown to the left the circuit bypasses the MPPT
algorithm and we obtain the desired power, voltage and current outputs through the respective
scopes. Contrarily when the switch is thrown to the right, the embedded MPPT function block is
included in the circuit and we obtain the desired outputs through the respective scopes.
25
Figure 5.4 : SIMULINK Model of MPPT system using P&O algorithm
26
6 DESIGN OF OPTIMAL CONFIGURATION FOR A
STANDALONE P-V MODULE
We have to design an optimal configuration for NS and NP so that we get the required power at
220V.
Therefore the total no of cells required to achieve 220V in series configuration is 13*no of cells per
Also net power achieved through configuration of series cells in 1 row = 37*no of panels
=37*13 = 481W
27
Total power to be compensated is assumed as 200 KW and the above case configuration is quite
less.
So we take different configurations of NS and Np to achieve the required power for which the
The different configurations for the panel can be viewed through the table 1 for the case of
28
6.1 Results
29
Case 3: ns=479 np=208 VMP=170 V PMP=82 kW Vreq=220 V
30
Case 5: ns=479 np=104 VMP=198 V PMP=46 kW Vreq=220 V
31
Case 7: ns=479 np=35 VMP=210 V PMP=17 kW Vreq=220 V
32
Case 9: ns=479 np=18 VMP=216 V PMP=8.8 kW Vreq=220 V
33
For Irradiation= 0.75kW/m2
34
Case 3: ns=479 np=100 VMP=198 V PMP=33 kW Vreq=220 V
35
Case 5: ns=479 np=20 VMP=215 V PMP=7.2 kW Vreq=220 V
36
6.1.2 Table For Different PV Panel Configurations
VREQ (In
Sl. No. Ns Np VMP (In Volts) PMP (In kW)
Volts)
1 479 417 150 126 220
37
6.2 Conclusion
From the above it can be deducted that the best configuration for achieving the required
objective is given below as
NS = 479
NP = 15
PMP = 7.2KW at 220V
The same procedure can again be repeated for the case of irradiance level 0.75
KW/m2.
So we again repeat the whole procedure through our Simulink model and we get the
best configuration as
NS = 479
NP = 12
PMP = 4.2KW at 220V
From theabove results it can be deducted that as we decrease the irradiance levels
there also a decrease in the maximum power.
38
7 DESIGN OF MAXIMUM POWER POINT TRACKING
(MPPT) BASED PV CHARGER
7.1 Abstract
There are two charging stages for the proposed PV charger. At the beginning of the
battery can be avoided using the pulse-charging scheme with adaptive rest period.
The main difference between the method used in the MPPT system and other
techniques used in the past is that the PV array output power is used to directly
A SEPIC circuit is used to realize a PV charger that can step up the PV panel
voltage for battery charging. Continuous input inductor current is helpful in achieving
a high MPPT accuracy. According to the maximum power transferring theorem, the
39
following relationship equation can be derived, Rth =Vmp/Imp=Rin=Rb (1-D)2/D2
panel current at maximum power point, respectively. The input resistance Rin of the
SEPIC circuit can be regulated by directly controlling the converter duty cycle D. As
long as the circuit is operated under maximum power transfer condition, MPPT can
be achieved.
40
As shown in Fig. 7.1, there are two charging stages for the proposed PV charger. At
adopted to extract maximum power from the PV panel. Under a constant solar power
condition, the battery current will decrease in accordance with the increase in battery
charging scheme with an adaptive rest period is applied to obtain an average charging
current with an exponential profile. During the charging period, the MPPT function is
Overcharging of the battery can be avoided using the pulse-charging scheme with
For the system proposed in this paper, MPPT is used to increase the efficiency of
maximum power of the PV panel can be extracted both in the continuous MPPT
charging stage and in the charging period of the pulse MPPT charging stage.
41
Figure 7.2(a) Average charging current waveform and (b) exponential profiles with
During the pulse charging stage, an average charging current with an exponential
battery voltage level Vb,set . The equation of the average charging current Ib (t) can
be expressed as follows:
where the attenuating factor determines the charging speed. The relationship
between the rest period Tr and the attenuating factor can be derived by
current during the pulse- charging stage. However, the battery voltage may be over
Vb,set due to the decline in the battery capacity if a fixed attenuating factor is
adopted. To prevent the battery from overcharging, an adaptive rest period Tr could
be realized by sensing the battery voltage. As the battery voltage goes over a given
value Vb,m, the rest period Tr can be extended to change the attenuating factor and
42
Figure 7.3shows a flowchart of the studied charging scheme.
The initial open-circuit battery voltage Vb,oc(t0) is measured at the beginning of the
charging process. The initial charge quantity Q(t0) can then be estimated as follows:
43
where Vb,ec and Vb,fc are the open-circuit battery voltages under fully discharged
and fully charged conditions, respectively, and C denotes the rated battery charge
quantity.
During the continuous MPPT charging stage, the P&O MPPT algorithm was used to
extract the maximum power of the PV panel. The charging process was switched to
the pulse MPPT charging stage from the continuous MPPT stage when the estimated
deterioration into consideration, pulse MPPT charging was also enabled as long as the
battery voltage rose to a given voltage Vb , set for overcharge prevention. During the
charging period of the pulse MPPT charging stage, MPPT was retained to achieve
profile is used to relax the electrolyte reaction and prolong battery lifetime.
Tthe time length Tpulse of pulse MPPT charging stage can be calculated as follows:
Where tf and ti are the ending and starting times of the pulse
44
7.4.1 Advantages of MPPT based Charge Controller over existing
Controllers
1. The system uses MPPT algorithm hence the efficiency of the system is higher.
2. 16x2 LCD display have been interfaced hence battery voltage can be
displayed on it. The user will be informed regarding battery status without
use of LED.
45
7.6 Conclusion
Perturb and Observe algorithm is simple method as it uses only voltage sensor to
sense PV array voltage. Time complexity of this method is also less as compared to
short circuit current, Fuzzy Logic Control, Neural Network Control). Such type of
algorithm is required as solar energy is uncertain source of power. The voltage and
current greatly depends upon insolation and temperature, hence the maximum power
point gets varied. MPPT is an electronic system that does not physically vary the
module towards sun to obtain maximum power but instead it varies electrical
operating point of modules so that modules can deliver maximum available power.
The operation of the PV system may fail to track the maximum power due to sudden
change in environmental conditions. The charge controller looks at the output of the
panels, and compares it to the battery voltage. It then Fig.s out what is the best power
that the panel can put out to charge the battery. It takes this and converts it to best
control of the devices as the program is burned into the permanent memory. It
performs fast calculations as 16 MHz crystal is used. Battery gets charged rapidly
when MPPT algorithm is implemented in the system. If Perturb and Observe method
is used frequently, the MPPT tracking method proves to be best over the methods like
MPPT attempt is always made to charge the battery at maximum possible power of
input source.
46
The MPPT based charge controllers are best suitable for wind and solar systems as
they track the maximum power in case of power fluctuations at the input side due to
computer and brings much more accuracy in the control of MOSFET and IGBT. The
MPPT charge controller operates with high efficiency (90% or even higher) as
47
8 References
boost converter for photo voltaic system, European journal of Scientific research,
14. Jui Liang yang, Ding Tsair Su, Ying Shing Shao, Research on MPPT and single
48
16. A. Daoud, A. Midoun, Fuzzy control of a lead acid battery charger, Journal of
17. Huang-Jen Chiu, Senior Member, IEEE, Yu-Kang Lo, Member, IEEE, Chun-Jen
2011
converters, IEEE Transactions Power Electronics., vol. 25, no. 9, pp. 2409-2419,
Sep. 2010.
19. S. J. Chiang, Hsin-Jang Shieh, Member, IEEE, and Ming-Chieh Chen, Modeling
20. B. Yang, W. Li, Y. Zhao, and X. He, Design and analysis of a grid connected
49
Appendix
50
Output Waveform of Boost Converter
51
State of Charging of Battery
52
Graph at the Time of Pulse Charging
53
Programs
function D = PO(V,I,T)
persistent P2 P1 dP d dd n;
if isempty(V)
V=20;
end
if isempty(I)
I=0;
end
if isempty(P2)
P2=0;
end
if isempty(P1)
P1=0;
end
if isempty(dP)
dP=0;
end
if isempty(d)
d=1;
end
if isempty(dd)
dd=0;
end
if isempty(n)
n=1;
end
%%%%%%%%%%%%%%%%%%%%%
if (T > n*0.02) %chu ki lay mau 0.02s
n = n + 1;
P1=P2;
P2=V*I;
dP=P2-P1;
if (dd==0)
if dP>1
dd=0.01;
d=d+dd;
else
if dP<-1
dd=-0.01;
d=d+dd;
else
dd=0;
end
end
else
if ((dP<1)&&(dP>-1))
dd=0;
d=d+dd;
else
if ((dP/dd)>0)
54
dd=0.01;
d=d+dd;
else
dd=-0.01;
d=d+dd;
end
end
end
end
D=d/(d+1);
if D<0.1
D=0.1;
d=D/(1-D);
else
if D>0.9
D=0.9;
d=D/(1-D);
else
end
end
end
2. Controller programming
55
temp_i=0.1;
temp_v=0;
temp_signal=1;
else
CV=1;
end
end
if CV
if I>5.0
temp_i=0;
temp_v=1;
temp_signal=2;
else
temp_fault=0;
end
end
end
signal=temp_signal;
SD=temp_fault;
Iref=temp_i;
Vref=temp_v;
end
56