Professional Documents
Culture Documents
B-W Calibration Procedure
B-W Calibration Procedure
B-W Calibration Procedure
1) Speed Calibration
Take down the data from Technical Data Sheet
a) Diameter of tacho wheel, b) No of teethes on wheel,
Calculation of Imp/mtr
1
11) Press Up or Down Key till display shows Charact. Val. Ns
B04 50.0 I/m
12) Press Prepare entry key
14) To come out normal display Press Abort key at any time.
2
2) Tare Calibration :-
There are two Tare calibration parameters,
i) Under Function Distributor without password (Normally this is used for operation
people). The name indicates >0: Zero Set
ii) Second under Calibration Function with password protected. The name indicates
TW: Tare
The difference between two Tare programs is as follows,
>0: Zero Set TW: Tare
a) Not required Password. a) Required password.
b) The result differences with Basic Tare b) The result is directly stored in
are store in D 05 Tare Correction T D04 Basic Tare and same data
and add to D03 Total Tare are stored in D03 Total Tare
Hang known weight on the weigh cradle, enter this weight value in the parameter
C08.
To start Span Calibration follow the steps given.
10) After showing display note down the value and enter in parameter D02