Download as txt, pdf, or txt
Download as txt, pdf, or txt
You are on page 1of 2

**************************Live load**********************

**DEFINE MOVING LOAD


******CLASS A TRAIN WITH IMPACT=1.154****
**TYPE 1 LOAD 15.56 15.56 65.78 65.78 39.3 39.3 39.3 39.3 15.56 15.56 65.78 65.78 -
**39.3 39.3 39.3 39.3
**DIST 1.1 3.2 1.2 4.3 3 3 3 20 1.1 3.2 1.2 4.3 3 3 3
*****70R(W) TRAIN WITH IMPACT=1.154****
**TYPE 2 LOAD 46.2 69.24 69.24 98.1 98.1 98.1 98.1 46.2 69.24 69.24 98.1 98.1 98.1
98.1
**DIST 3.96 1.52 2.13 1.37 3.05 1.37 30 3.96 1.52 2.13 1.37 3.05 1.37
******SV TRAIN****
**TYPE 3 LOAD 30 47.5 47.5 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90
90
**DIST 3.2 1.370 5.389 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
1.5 1.5 1.5 1.5
****LIVE LOAD CASES FOR OUTER GIRDER**
****CASE-1 2CLA PLACED MOST ECC.
**LOAD GENERATION 925
**TYPE 1 -64 0 3.125 XINC 0.15
**TYPE 1 -64 0 4.925 XINC 0.15
**TYPE 1 -64 0 6.625 XINC 0.15
**TYPE 1 -64 0 8.425 XINC 0.15
*************************************
*****LIVE LOAD CASES FOR INNER GIRDER**********
*****CASE-2 CLASS A PLACED TO THE TOP OF INTERNAL GIRDER NO 2
**LOAD GENERATION 925
**TYPE 1 -64 0 4.075 XINC 0.15
**TYPE 1 -64 0 5.875 XINC 0.15
**TYPE 1 -64 0 7.575 XINC 0.15
**TYPE 1 -64 0 9.375 XINC 0.15
***********************************************
******CASE-3 CLASS A PLACED TO THE TOP OF INTERNAL GIRDER NO 3
**LOAD GENERATION 925
**TYPE 1 -64 0 6.475 XINC 0.15
**TYPE 1 -64 0 8.275 XINC 0.15
**************************************
*******CASE-4 70RW PLACED MOST ECC.
**LOAD GENERATION 925
**TYPE 2 -64 0 4.355 XINC 0.15
**TYPE 2 -64 0 6.285 XINC 0.15
********************************************
*******LIVE LOAD CASES FOR INNER GIRDER**********
******CASE 5 ONE LANE 70RW CG MATCHING GIRDER NO 3
**LOAD GENERATION 925
**TYPE 2 -64 0 5.551 XINC 0.15
**TYPE 2 -64 0 7.440 XINC 0.15
************************************************
*****CASE-6 70RW PLACED TO THE TOP OF INTERNAL GIRDER NO 3
**LOAD GENERATION 925
**TYPE 2 -64 0 6.475 XINC 0.15
**TYPE 2 -64 0 8.405 XINC 0.15
******CASE-7 SV PLACED AT CENTER.
**LOAD GENERATION 800
**TYPE 3 -40 0 5.575 XINC 0.15
**TYPE 3 -40 0 7.375 XINC 0.15
********CASE-8 SV PLACED AT 300 ECC. TO CENTER
**LOAD GENERATION 800
**TYPE 3 -64 0 5.275 XINC 0.15
**TYPE 3 -64 0 7.075 XINC 0.15
*******************************************************

You might also like