Professional Documents
Culture Documents
Kyoritsu 2016-2017 L
Kyoritsu 2016-2017 L
INSULATION TESTERS
Analogue Insulaon Testers Analogue Insulaon/Connuity Testers
3165 3166 3161A 3131A 3132A
Appearance
Appearance
EARTH TESTERS
Earth Testers Earth Clamp Testers Simplied Earth Tester
4102A 4105A 4106 4200/4202 4300
Appearance 4202
Bluetooth
Conductor size(MAX.mm) - - - 32 -
Earth resistance 12/120/1200 20/200/2000 2/20/200/2000/20k/200k 20/200/1500 200/2000
Earth resisvity - - 2/20/200/2000/20k/200k - -
Earth vol tag e 30V AC 200V AC 50V AC - 300V AC
AC A - - - 100/1000mA/10/30A -
Noize check - - - -
Memory funcon - - 800 data 100 data -
Back light - -
IEC 61010-1 CAT 300V,
IEC 61010-1 CAT 300V ,
IEC 61010-1 CAT 300V, IEC 61010-1 CAT 300V, CAT 150V,
IEC 61010-1 CAT 300V, IEC 61010-031,
IEC 61010-031, IEC 61010-031, IEC 61010-031,
Applicable standards IEC 61010-2-032, IEC 61557-1, 5,
IEC 61557-1, 5, IEC 61557-1, 5, IEC 61557-1, 5,
IEC 61326 IEC 61326-1,
IEC 60529(IP54) IEC 60529(IP54) IEC 61326-1,
IEC 60529(IP40)
IEC 60529(P54)
Power source R6/LR6 6 R6/LR6 6 R6/LR6 8 R6/LR6 4 R6/LR6 2
Dimensions (L)(W)(D)mm 10515870 10515870 16718589 24612054 2325142
Weight (Approx.) 600g 550g 900g 780g 220g
HIGH VOLTAGE INSULATION TESTERS
Analogue High Voltage Insulaon Testers
3121B 3122B 3123A 3124
Appearance
Appearance
500V(500G)
250V(100M) 250V(10G)
250V(100M) 1000V(1T)
500V(1000M) 500V(100G)
Test voltage 500V(1000M) 2500V(2.5T)
1000V(2G) 1000V(200G)
(Max.measurement value) 1000V(2G) 5000V(5T)
2500V(100G) 2500V(1T)
2500V(100G) 10000V(35T)
5000V(1000G) 5000V(10T)
12000V(35T)
AC/DC Voltage ranges 30 - 600V AC/DC 30 - 600V AC/DC 30 - 600V AC/DC 30 - 600V AC/DC
Back light
Current - - 0.00nA - 5.50mA 0.00nA - 2.40mA
Capacitance - - 5.0nF - 50.0F 5.0nF - 50.0F
Memory - -
Rechargeable lead storage Rechargeable lead storage
Power s ource L R 14 8 LR14 8
baery (12V) baery (12V)
380430154 330410180
Dimensions (L)(W)(D)mm 177226100 177226100
*Instrument and Hard case *Instrument and Hard case
Weight (Approx.) 1.7kg 1.9kg 8kg 9kg
www.kew-ltd.co.jp
MULTIMETERS
Digital Mulmeters Analogue Multimeters Digital Mulmeters
1020R 1021R 1109S 1110 1018/1018H* 1019R 1030
Appearance
DC V 600mV - 1000V 600mV - 600V 0.1 - 1000V 3 - 600V 400mV - 600V 600mV - 600V 400mV - 600V
AC V 600mV - 1000V 600mV - 600V 10 - 1000V 30 - 600V 4 - 600V 6 - 600V 4 - 600V
DC A - 6A - 10A 50uA - 250mA 60uA - 300mA - - -
ACA - 6A - 10A - - - - -
Resistance
Connuity buzzer -
Capacitance - -
Frequency - - -
Back light - - - -
Logging memory - - - - - - -
CAT 300V,
Measurement CAT 300V, CAT 300V CAT 300V
categories CAT 600V, - CAT 300V CAT 600V
CAT 600V CAT 600V CAT 600V
CAT 1000V
Power source R03/LR03 2 R03/LR03 2 R62/6F221 R6 2 LR44 2 CR2032 1 LR44 2
Dimensions (L)x(W)x(D)mm 1557540 1557540 15010047 1409439 1075410 1268518 1903931
Weight (Approx.) 250g 250g 330g 280g 70g 135g 100g
*HHard case type
Digital Mulmeters
1009 1011/1012 1051/1052 1061/1062 2000/2001 2012R
2000
1062
Appearance PEAK 6
1012 HOLD 2001
12
10
DC V 400mV - 600V 600mV - 600V 600mV - 1000V 50mV - 1000V 340mV - 600V 600mV - 600V
AC V 40mV - 600V 6 - 600V 600mV - 1000V 50mV - 1000V 3.4 - 600V 6 - 600V
60A(2000)
DC A 400uA - 10A 600uA - 10A 600uA - 10A 500uA - 10A 60/120A
100A(2001)
60A(2000)
AC A 400uA - 10A 600uA - 10A 600uA - 10A 500uA - 10A 60/120A
100A(2001)
Resistance
Connuity buzzer
Capacitance -
Frequency
Back light - - - -
Logging memory - - (1052) - -
Measurement CAT 300V CAT 600V, CAT 600V, CAT 300V, CAT 300V,
CAT 300V
categories CAT 600V CAT 1000V CAT 1000V CAT 600V CAT 600V
Power source R6 2 R6/LR6 2 LR6 4 LR6 4 R03/LR03 2 R03/LR03 2
1288424(2000)
Dimensions (L)(W)(D)mm 1618250 1618250 1929049 1929049 1289227
1289227(2001)
210g(2000)
Weight (Approx.) 280g 280g 560g 560g 220g
220g(2001)
Appearance
2433R 2413R
Conductor size(MAX.mm) 24 40 40 40 28 68
Frequency response 40 - 400Hz 20Hz - 1kHz 20Hz - 1kHz 40 - 400Hz 40 - 400Hz 40Hz - 1kHz
AC A 20mA - 200A 4mA - 100A 40mA - 400A 20mA - 500A 400mA - 100A 200mA - 1000A
ACV - - - 600V - -
Resistance - - - - -
Back light - - - - - (2413R)
Peak hold - - -
Frequency lter
Measurement categories CAT 300V CAT 300V CAT 300V - CAT 300V CAT 300V
Power source LR-44 2 R03/LR03 2 R03/LR03 2 6F22 1 R03/LR03 2 6F22 1
Dimensions (L)(W)(D)mm 1496026 1858132 1858132 2099645 1697540 25013050
Weight (Approx.) 120g 290g 270g 450g 220g 570g
CLAMP METERS
AC Clamp Meters
2007R 2200 2002PA 2204R
2031 2017 2027 2040 2608A
2117R 2200R 2002R 2210R
Appearance
2200R 2002R
Weight (Approx.) 100g 400g 220g 400g 300g 120g 470g 275g 470g
*1 2007R *3 2200 *5 2204R
*2 2117R *4 2200R *6 2210R
Appearance
2056
Conductor size
6 7.5 24 33 40 55 55 10
(MAX.mm)
DC DC DC DC DC DC DC
Frequency response DC
40Hz - 2kHz 20Hz - 1kHz 40 - 400Hz 40 - 400Hz 40Hz - 1kHz 20Hz - 1kHz 50/60Hz
ACA - 200mA - 20A 40/300A 600A 600/1000A 400/2000A 400/2000A 100A
DCA 20/120mA 2/20A 40/300A 600A 600/1000A 400/2000A 400/2000A 100A
ACV - - - 6 - 600V 6 - 600V 400/750V 40 - 750V -
DCV - - - 600mV - 600V 600mV - 600V 400/1000V 40 - 1000V -
Resistance - - - -
Connuity buzzer - - - -
Frequency - - - - -
Back light - - - - -
Peak hold - - - (2056R) (Max) -
Max/Min - - - - - -
Measurement CAT 600V CAT 600V
CAT 300V - CAT 300V CAT 600V CAT 600V CAT 300V
categories CAT 1000V CAT 1000V
Power source R6/LR6 4 6LR61 1 LR-44 2 R03/LR03 2 R03/LR03 2 R6/LR6 2 R6/LR6 2 R03/LR03 2
1116140 1426426
Dimensions (Display unit) (Display unit)
1475925 2437736 2548236 25010549 25010549 1614030
(L)(W)(D)mm 1043420 1532318
(Sensor) (Sensor)
Weight (Approx.) 290g 220g 100g 300g 310g 530g 540g 110g
*In the PEAK mode,the auto-ranging feature is disabled and measuring ranges are fixed as follows.
DC/ACA:0-400.0A
DC/ACV:0-400.0V
LOOP/PSC TESTERS PORTABLE APPLIANCE TESTER
LOOP/PSC Testers Portable Appliance Tester
4118A 4140 6201A
Appearance Appearance
RCD TESTERS
RCD Testers
5406A 5410
Appearance
15/30/50/100mA(5)
Rated tripping current 10/20/30/200/300/500mA 15/30/50/100/200/500mA
(1,1/2, AUTO)
Fault condion s ettings 1/2, 1, 5, DC, AUTO 5, 1, 1/2, AUTO
Voltage measurement - 80-450V
Lowest res olution 1ms 1ms
0 and 180 degree phase angle switch
Constant current tesng
Check operaon of DC sensive breakers -
Operang voltage 230V +10%, -15%(50Hz) 100V 10%, 200V +32%, -10%, 400V 10%(50/60Hz)
IEC 61010-1 CAT 300V, IEC 61010-1, CAT 300V/CAT 400V,
Applicable standards
IEC 61557-1, 6, IEC 60529(IP54) IEC 61557-1, 6, IEC 60529(IP54)
Power source - R6/LR6 8
Dimensions (L)(W)(D)mm 18616789 18616789
Weight (Approx.) 800g 965g
PHASE INDICATORS
Phase Indicators
8030 8031/8031F 8035
Non-Cantach
Safety Phase
Standard type Indicator
Appearance
CE type
www.kew-ltd.co.jp
MULTI FUNCTION TESTERS
Mul Funcon Testers
6010B 6011A 6016 6018
Appearance
KEWTECH Brand
Voltage Testers Digital Clamp Meters
KT170 KT171 KT200 KT203
Appearance Appearance
Bluetooth Bluetooth
LOGGERS
3 channel inputs for the simultaneous 3 channel inputs for the simultaneous
recording of Leakage and Load Current recording of Leakage Current, Load
Current and Voltage
5020
5010 Normal, Trigger, Capture,
Recording mode Normal, Trigger, Capture Recording mode
Power quality analysis
Communicaon Interface USB Communicaon Interface USB
Power supply External supply DC9V/LR64 Power supply External supply DC9V/LR64
Dimensions 111(L)60(W)42(D)mm Dimensions 111(L)60(W)42(D)mm
Weight (Approx.) 265g Weight (Approx.) 265g
SENSORS
Load current Load current(For Power Meter)
8121 8122 8123 8124 8125 8126 8127 8128 8129 8130
Appearance
Appearance
Conductor size(MAX.mm) 24 40 68 24 40 68 -
Rated current(AC)/voltage(AC) 1000mA 1000mA 1000mA 30A 70A 100A 600V
Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely for correct use. Failure to follow the safety rules can cause
Safety Warnings : fire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument.
http://www.kew-ltd.co.jp
In consideration of the environment, vegetable oil ink and recycled paper were used in this publication.The contents of this leaflet are subject to change without notice. 16.06 F