This document provides a fault description, diagnosis, and recommended actions for a vehicle with VIN P762353. The diagnosis monitors the voltage supply line between terminals 15 N_1 and KL87_1 for open circuits or shorts to ground. The fault is detected when no voltage is applied at the DME input despite the main relay being enabled. The recommended actions are to check the voltage supply and wiring harness between the DME and main relay, and potentially replace the main relay.
This document provides a fault description, diagnosis, and recommended actions for a vehicle with VIN P762353. The diagnosis monitors the voltage supply line between terminals 15 N_1 and KL87_1 for open circuits or shorts to ground. The fault is detected when no voltage is applied at the DME input despite the main relay being enabled. The recommended actions are to check the voltage supply and wiring harness between the DME and main relay, and potentially replace the main relay.
This document provides a fault description, diagnosis, and recommended actions for a vehicle with VIN P762353. The diagnosis monitors the voltage supply line between terminals 15 N_1 and KL87_1 for open circuits or shorts to ground. The fault is detected when no voltage is applied at the DME input despite the main relay being enabled. The recommended actions are to check the voltage supply and wiring harness between the DME and main relay, and potentially replace the main relay.
system version data version VIN P762353 Vehicle 1'/F20/SHA/M135i/N55/AUTO/ECE/LL/2015/05 Int.lev.works - Int.lev. - Int.lev.(tar.) - (cur.) Mileage 0 km
Fault description Diagnosis monitors the voltage supply line of terminals
15N_1 and KL87_1 for open circuit and short to ground.
Malfunction monitoring conditions
The fault is detected when no voltage is applied at the
DME input (KL87_1 or 15N_1) despite the main relay being enabled.
Condition for fault Voltage precondition
identification - Vehicle voltage between 9V and 16V
Temperature condition
- None
Time condition
- None
Other preconditions
- None
Terminal status
- Terminal 15
Condition for fault The fault is entered within 10 seconds.
memory entry
Action in service - Check voltage supply
- Wiring harness between DME and main relay
13/04/2017 2/2
- Replace main relay
Fault effect and Breakdown in extreme cases
breakdown warning
Driver information Emissions warning light and engine warning light