Professional Documents
Culture Documents
Metodo Tabular
Metodo Tabular
discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/268149124
CITATION READS
1 635
2 authors:
All content following this page was uploaded by Valdir Pignatta Silva on 11 November 2014.
The user has requested enhancement of the downloaded file. All in-text references underlined in blue are added to the original document
and are linked to publications on ResearchGate, letting you access and read them immediately.
Dimensionamento de estruturas de concreto armado em situao de
incndio. Mtodos tabulares apresentados em normas internacionais.
Av. Prof. Almeida Prado, trav. 2, n 271, sala 123LMC. Dept. Eng. Estruturas e Fundaes [Ed. Eng. Civil].
CEP: 05508-900, Cidade Universitria, So Paulo S.P. Brasil. Tels.: (11) 3091-5542 / 5562.
Fax: (11) 3091-5181.
Resumo
2 Normatizao brasileira
Atualmente, o CEB (1997) apud ISAIA (2002) define o conceito de durabilidade das
estruturas de concreto como a capacidade de uma estrutura apresentar o desempenho
requerido durante o perodo de servio pretendido, sob a influncia dos fatores de
degradao incidentes, ou seja, durante toda a sua vida til, a estrutura deve apresentar
segurana tanto em situao normal, como em situao excepcional.
Figura 2.3: Runas do depsito das lojas Zlo S/A, por ocasio do incndio (COSTA (2002)).
fase de fase de
aquecimento resfriamento
ignio
tempo tempo
inflamao
generalizada
(flashover)
Figura 3.1: Curva temperatura-tempo de um incndio Figura 3.2: Modelo do incndio natural.
real (SILVA (2001)).
1200
1000
temperatura (C)
800
600
400
ISO 834 (1975)
200
"H" - curva de incndio para
hidrocarbonetos (prENV 1991-1-2 (2001))
0
0 30 60 90 120 150 180 210 240
tempo (min)
Figura 3.3: Curvas naturais paramtricas (prEN Figura 3.4: Curva-padro ISO 834 (1975) para
1991-1-2 Draft (2002)). Os valores de materiais celulsicos e curva H (prEN 1991-1-2
correspondem ao grau de ventilao. Draft (2002)) para materiais hidrocarbonetos.
Outras curvas-padro para materiais inflamveis (ASTM E1529 (1993), RWS, RABT)
foram modeladas em funo da severidade do incndio e tm sido internacionalmente
recomendadas para situaes especiais (COSTA (2002)).
Incndio-padro
o o
Temperatura ( C ) Temperatura ( C )
Incndio natural
Temperatura no
elemento estrutural
Temperatura no
elemento estrutural
Anexo B do
Instruccin EH-
80 (1980) apud
normas
NZS 3101
prEN 1992-1-2 CEBBulletin BS 8110-2 AS-3600
CNOVAS
NBR 5627 (1980) Projeto NBR
Projeto NBR 6118:2002 Part 1
(1988)
(2002) N 208 (1991) (1985) (2001) cancelada 6118 (2001)
(1985)
cancelado
hlaje
hlaje
hlaje
hlaje
hlaje
hlaje
hlaje
TRRF
cmn
hlaje
y x
y x
y x
y x
y x
y x
y x
y x
y x
30 60 10* 10* 10* 60 10 10 10 75 15 15 60 15 10 50 10 10 100 10 60 10 10 10
60 80 20 15* 15* 80 25 10 25 95 20 20 80 20 15 75 10 10 100 20 80 25 10 25 80 10 15 20
50 70 100 120 150 20 25 35 45
90 100 30 10* 20 100 35 15 35 110 25 20 100 25 15 95 20 15 125 30 120 45 20 I.E. 45 100 15 20 30
120 120 40 20 25 120 45 20 45 125 35 25 120 30 15 110 30 15 125 40 150 60 30 30 120 20 25 40
* Normalmente o cobrimento adotado para situao ambiente suficiente.
Legenda: cobertura no em balano
piso ou cobertura em balano
suportam veculos com peso at 30 kN
suportam veculos com peso acima de 30 kN
lajes protendidas
I. E. = interpolao linear
Nota: Nem todas as normas apresentam o cobrimento mnimo explicitamente. Ele pode ser estimado em funo da distncia a, pela expresso cmn a 10 mm
Tabela 4.1: Dimenses mnimas de lajes macias de concreto de densidade normal (agregados granticos) recomendadas por algumas normas internacionais, em funo do TRRF.
Figura 4.3: Dimenses de largura bmin e o cobrimento das armaduras cmn distncia a entre o centro geomtrico da
armadura principal e a face exposta ao fogo (AS 3600 (2001)). Essas dimenses so referncias dos mtodos tabulares.
BS 8110-2
Normas
NBR 5627 Anexo B do Projeto NBR 6118
(1985)
(1985)
cobrimentos mnimos possveis combinaes entre bmn e
cmn (mm) possveis combinaes entre bmn e possveis combinaes entre bmn cmn
Largura classes de agressividade a e a
mnima ambiental
das
vigas
bmn
bmn
cmn
cmn
TRRF
bmn
bmn
bmn
bmn
bmn
cmn
cmn
cmn
cmn
(mm)
bmn
bmn
bmn
bmn
bmn
bmn
bmn
bmn
bmn
cmn
a
a
30 80 25 120 20 160 15* 200 15* 80 25 120 15 160 10 200 10 80 20 80 20 80 25 120 15 140 10 190 10
120
60 120 40 160 35 200 30 300 25 120 40 160 35 200 30 300 25 120 30 120 30 120 40 120 40 140 35 190 30 300 25
25 30 40 50
90 150 55 200 45 300 40 400 35 150 55 200 45 250 40 400 35 150 40 150 45 200 65 140 55 190 45 250 40 400 35
100 120 200 65 240 60 300 55 500 50 200 65 240 55 300 50 500 45 200 50 200 55 240 80 190 65 240 55 300 50 500 45
* Normalmente o cobrimento adotado para situao ambiente suficiente.
Tabela 4.3: Dimenses mnimas de vigas bi-apoiadas de concreto de densidade normal (agregados granticos) recomendadas por algumas normas internacionais,
em funo do TRRF.
Normas
BS NBR 5627 Anexo B do Projeto
(1985)
cobrimentos mnimos possveis combinaes
cmn (mm) possveis combinaes entre possveis combinaes entre entre bmn e cmn
Largura classes de agressividade bmn e a bmn e a
mnima ambiental
das
vigas
bmn
bmn
cmn
cmn
TRRF
bmn
bmn
bmn
bmn
cmn
cmn
cmn
(mm)
bmn
bmn
bmn
bmn
bmn
bmn
bmn
bmn
bmn
cmn
cmn
a
a
30 80 15* 160 12* 80 12 200 12 80 20 75 20 80 20 80 12 140 12 190 12
120
60 120 25 200 12* 120 25 200 12 300 12 80 20 120 20 120 20 80 25 120 25 190 12 300 12
25 30 40 50
90 150 35 250 25 400 25 450 25 150 35 250 25 400 25 120 35 150 25 150 25 115 40 140 35 250 25 400 25
100 120 220 45 300 35 450 35 500 30 200 45 300 35 500 35 150 50 200 35 200 35 240 80 220 45 300 35 500 35
Legenda: bmn = largura mnima da viga;
cmn = cobrimento mnimo das armaduras principais da viga;
a = distncia entre o centro geomtrico das armaduras principais e a face mais prxima do elemento de concreto, exposta ao fogo.
Nota: Nem todas as normas apresentam o cobrimento mnimo explicitamente. O cobrimento pode ser estimado em funo da distncia a, por meio da expresso cmn a 10 mm
Tabela 4.4: Dimenses mnimas de vigas contnuas de concreto de densidade normal (agregados granticos) recomendadas por algumas normas internacionais,
em funo do TRRF.
NZS 3101
AS-3600
Projeto NBR 6118:2002
(2001)
(1985)
Part 1
cobrimentos mnimos cmn todas as faces expostas
expostas
pilar
todas as
exposta
exposta
exposta
50% da
1 face
seo
1 face
faces
(mm)
possveis combinaes entre bmn, a e Fd
classes de agressividade
fck = 20 (MPa) fck = 45 (MPa)
ambiental
bmn
TRRF
bmn
bmn
cmn
cmn
bmn
bmn
bmn
bmn
bmn
bmn
bmn
bmn
cmn
cmn
cmn
Fd
Fd
Fd
Fd
a
a
3,0 200 820 370 1300
30 150 25 200 25 150 25 200 25 100 10 150 20 125 20 100 20 150 10 150 10
6,0 100 360 140 500
3,0 440 730 830 1500
60 200 35 240 30 200 35 240 30 120 25 200 25 160 25 120 25 200 20 200 20
6,0 200 360 260 510
190 25 30 40 50
3,0 530 1000 1000 1800
90 240 50 300 35 240 50 300 35 140 35 250 30 200 25 140 25 240 35 250 35
6,0 330 640 470 1300
3,0 810 1500 1500 3000
120 300 50 350 35 300 50 350 35 160 40 300 35 240 25 160 25 300 45 300 45
6,0 480 1000 1000 2100
Em casos especiais permite-se 120 mm b < 190 mm (vide item 13.2.3 do Projeto NBR 6118:2002).
cmn
bmn
IV
TRRF
I II III bmn cmn (mm) bmn cmn bmn cmn bmn cmn bmn cmn
muito bmn (mm) bmn (mm)
fraca moderada forte (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
forte
Em casos especiais permite-se 120 mm b < 190 mm (vide item 13.2.3 do Projeto NBR 6118:2002).
Legenda: Fd ,fi Fd = valor de clculo da ao em situao normal;
fi = , onde:
Fd Fd,fi = valor de clculo da ao em situao de incndio.
Tabela 4.7: Dimenses mnimas recomendadas pela normatizao brasileira e pela Instruccin espaola, para pilares de concreto de densidade normal
(agregados granticos) em funo do TRRF.
Durao do
Corpo-de prova Tipo de Carregamento Modo de
ensaio
n agregado (kN) ruptura
(hr : min)
1 silicoso 0 4:00 nenhum
2 silicoso 1300 2:50 compresso
3 silicoso 800 3:38 compresso
4 silicoso 710 3:40 compresso
5 silicoso 0 5:00 nenhum
6 silicoso 170 3:00 flambagem
7 silicoso 1070 3:28 compresso Notas: seo transversal de 406 mm x 406 mm
8 silicoso 1800 2:26 compresso seo transversal de 203 mm x 203 mm
9 silicoso 1300 3:07 compresso
10 calcreo 800 8:30 compresso Tabela 4.8: Desempenho de pilares ensaiados, de dimenses 305 mm x 305 mm. Para
11 calcreo 1070 6:06 compresso sees transversais menores, as respectivas dimenses esto indicadas nas notas supra (ACI
12 calcreo 1800 3:36 compresso 216R (1989)).
Tabela 4.9: Dimenses mnimas de pilares de seo circular ou retangular (desprezando-se a esbeltez) em funo do TRRF, propostas pelo Eurocode 2 (prEN
1991-1-2 (2002)) e pelo Projeto NBR 6118 (2002).
Tabela 4.10: Dimenses mnimas da largura e da distncia entre o eixo da armadura e a face exposta ao
fogo para pilares de sees retangular e circular. Taxa mecnica de armadura = 0,1. Valores moderados
para momentos de 1 ordem: e = 0,05.b 100 mm (prEN 1991-1-2 (2002)).
5.1.3 Normas europias (prEN 1992-1-2 (2002), CEBBulletin N 208 (1991) e BS 8110-2
(1985))
Para TRRF = 30 ou 60 minutos, as lajes de espessura hlaje 80 mm atendem aos
mnimos requeridos pelas normas europias.
Para o TRRF = 90 minutos, as lajes armadas em uma direo no atendem aos mnimos
requeridos pelo Eurocode 2 (prEN 1992-1-2 (2002)), para hlaje < 100 mm ou classes de
agressividade ambiental I e II. As lajes armadas em duas direes atendem aos mnimos
requeridos pelo Eurocode 2 para hlaje > 100 mm.
A comparao com a BS 8110-2 e o CEB-FIP Model Code 90 (Bulletin N 208 (1991))
depende da combinao entre espessura e cobrimento adotados.
Para TRRF = 30 ou 60 minutos, as vigas atendem aos mnimos requeridos pelas normas
europias, exceto as vigas isostticas de classe de agressividade ambiental I. Para TRRF
= 90 minutos, as vigas isostticas com dimenses usuais no atendem aos mnimos
requeridos pelas normas europias. Para as vigas contnuas a comparao com as
normas europias depende da combinao entre espessura e cobrimento adotados.
As lajes e vigas no apresentam dimenses suficientes para resistirem ao TRRF = 120
minutos.
No caso dos pilares, a comparao com o CEBFIP Model Code 90 depende do nmero
de faces expostas, das dimenses da seo transversal, da resistncia do concreto, da
taxa de armadura e do carregamento aplicado.
Para TRRF = 30 ou 60 minutos, os pilares atendem aos mnimos requeridos pela BS
8110-2. Para TRRF 90 minutos, a comparao com a norma britnica depende do
nmero de faces expostas e das dimenses da seo transversal.
Segundo o Eurocode 2, os pilares atendem aos mnimos requeridos para TRRF = 30
minutos, desde que apresentem comprimento 0,fi 3 m, rea de ao As < 0,04.Ac,
6 Concluses
O concreto armado, como qualquer outro material, sofre os efeitos da ao trmica,
podendo comprometer a sua capacidade mecnica e de compartimentao. Os esforos
solicitantes colaboram na reduo progressiva da resistncia do concreto aquecido. Tais
fatores devem ser avaliados no projeto (fire design) da estrutura para assegurar sua
estabilidade.
A nova norma de dimensionamento de estruturas de concreto NBR 6118 (2002)
recomenda aumentar cobrimentos e dimenses mnimas das peas de concreto, visando
aumentar a durabilidade das estruturas. Dessa forma, indiretamente, induzir
concepo de elementos de concreto com resistncia ao fogo, ligeiramente superiores
quelas projetadas segundo as normas antigas.
Neste trabalho as recomendaes de segurana contra incndio apresentadas por
normas internacionais foram comparadas s recomendaes do Projeto NBR 6118 (2002)
para dimensionamento temperatura ambiente. Em uma anlise expedita, considerando-
se apenas as caractersticas geomtricas dos elementos estruturais concluiu-se que para
TRRF igual a 30 e 60 minutos os elementos estruturais com dimenses usuais atendem
as prescries internacionais, com algumas excees.
No caso de edificaes de maior risco. cujo TRRF 90 minutos, as dimenses usuais
ainda esto aqum das exigncias internacionais.
Lajes pr-moldadas tipicamente utilizadas no Brasil ainda esto sem soluo, pela falta de
laboratrios de ensaio de resistncia ao fogo no pas, a fim de avaliar o comportamento
ao fogo desses elementos.
O meio tcnico brasileiro precisa se conscientizar da importncia de seguir-se padres
internacionais para o dimensionamento das estruturas de concreto em situao de
incndio, visando qualidade do desempenho das construes.
7 Agradecimentos
A CAPES Coordenao de Aperfeioamento de Pessoal de Nvel Superior, pelo apoio
dado a esta pesquisa.
8 Referncias
AMERICAN CONCRETE INSTITUTE (ACI). Guide for determining the fire endurance
of concrete elements. ACI 216R89. New York, 1989.
ASSOCIAO BRASILEIRA DE NORMAS TCNICAS (ABNT). Componentes construtivos
estruturais - Determinao da resistncia ao fogo. NBR 5628. Rio de Janeiro, 2001.
ASSOCIAO BRASILEIRA DE NORMAS TCNICAS (ABNT). Dimensionamento de
estruturas de ao de edifcios em situao de incndio Procedimento. NBR
14323. Rio de Janeiro, 1999.
ASSOCIAO BRASILEIRA DE NORMAS TCNICAS (ABNT). Exigncias de resistncia
ao fogo de elementos construtivos das edificaes. NBR 14432. Rio de Janeiro, 2000.
ASSOCIAO BRASILEIRA DE NORMAS TCNICAS (ABNT). Exigncias particulares