Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Co. No.

675314 - P TUBE EXPANSION REPORT

Revision Rev. 0 POWER BOOSTER ENGINEERING AND MAINTENANCE SDN BHD

Manufacturer Name Report No


Client Project Code
Equipment Name E - 1201 Drawing No

Before Expansion After Expansion Tube's


Column Tube's Outside Tube's Inside Tubesheet's hole Tube's Inside Expansion
No. Row No. Inside Diameter
No. Diameter (mm) Diameter (mm) Diameter (mm) Ratio (%)
(mm)
a b d e E

1 19.05 14.60 19.19 -331.24%


2 19.05 14.61 19.20 -332.43%
3 19.05 14.60 19.21 -331.69%
4 19.05 14.59 19.21 -330.72%
5 19.05 14.60 19.20 -331.46%
6 #DIV/0!
7 #DIV/0!
8 #DIV/0!
9 AVERAGE VALUE #VALUE!
10 #DIV/0!
11 19.05 14.60 19.20 15.02 6.07%
12 19.05 14.60 19.20 15.03 6.29%
13 19.05 14.60 19.20 15.07 7.19%
14 19.05 14.60 19.20 15.10 7.87%
15 #DIV/0!
16 #DIV/0!
17 #DIV/0!
18 #DIV/0!
19 #DIV/0!
20 #DIV/0!
21 #DIV/0!
22 #DIV/0!
23 #DIV/0!
24 #DIV/0!
25 #DIV/0!
26 #DIV/0!
27 #DIV/0!
28 #DIV/0!
29 #DIV/0!
30 #DIV/0!
31 #DIV/0!
32 #DIV/0!
33 #DIV/0!
34 #DIV/0!

i. Expansion Ratio [(e-b)-(d-a)]


E= x 100%
(a-b)
ii. Expansion Ratio shall not exceed 8% as per API 660.