FUGRO TECHNICAL SERVICES LIMITED ipsa Cot 10524802258 Sime Seen Taltam 5 Ngee Saco ence MateriaLab freon bate Report No. : 141695EN140507(2) Page 1 of 1 ‘Test Report on Analysis of Paint Information Supplied by Client Client B&S Group Holdings Limited Client's address Room 402-403, Winning House, 10-16 COCHRANE Street Central HK Project Tee ‘Sample description Rte CPE ETE ‘Sample identification BSM 903 Test required 2 Through dry time Laboratory Information Lab sample ID EN140507/1 Date of receipt of sample : 12/05/2014 Date test completed 22/05/2014 Test method used BS EN ISO 9117-3: 2010 Results Through dry time, min Average wet film thickness of test specimen, ym 50-55 Average dry film thickness of test specimen, ym Remarks : 41. Thinning Ratio — No dilution. 2. Single coating of paint was applied manually to chromated aluminium panel using a SQum bar for the test 3. The wet film thickness was measured with reference to BS 3900 : C5 : 1997 Method 1A using a comb gauge. 4. The dry film thickness was measured with reference to BS 3900 : C5 : 1997 Method 7. 5. The coated test panel was allowed to dry in a vertical position with free circulation of air, but shielded from draughts and direct sunlight, at a temperature of 23 + 2 °C and 50 +5 % RH. ‘Supervised by K. F. Wong Certified by proved Signatory: HO Kin Man, John Manager - Chemistry Department Date Waleare * End of Report Note : This report refers only to the sample(s) tested. ‘The copy ofthis documents owned by Fuge Techical Senices Lind, tay nt be reproduce Comons: