ENGINEERED SOLUTIONS

ARMORTEC Product Details

ArmorFlex - Open Cell ArmorFlex - Closed Cell

ArmorWedge

ArmorLoc
A-Jacks

ArmorFlex Block and a Half ArmorRoad

MANUFACTURING SPECIFICATION
ASTM D6684-04
ArmorFlex (not to scale)

L L

H
W W

Open Cell Block Closed Cell Block


4" - 6 DRAINAGE LAYER

ARMORFLEX TAPERED
ARTICULATED CONCRETE BLOCK (TYP.)

FLOW

H GEOGRID
(SIZED TO CONTAIN
DRAINAGE LAYER)

L SITE SPECIFIC
GEOTEXTILE

NATIVE SOIL

TAPERED BLOCK TYPICAL


H CROSS SECTION
NOT TO SCALE

Tapered Series Tapered Series - Cross Section

ArmorFlex Block and a Half (not to scale)

TOP - OPEN

TOP - OPEN

TOP - OPEN
Standard Block and a Half

TOP
Open - OPEN
Cell Block TOP - CLOSED
Closed Cell Block H

TOP - CLOSED
OPEN
Tapered Block and a Half
TOP - CLOSED
PLAN

ArmorFlex cont.
(not to scale) TYPICAL ARMORFLEX MAT
8 (nominal)
NOT TO SCALE

CABLE WASHER

CABLE

CABLE SLEEVE

AS REQUIRED
WASHER

CABLE SLEEVE N.T.S.

ArmorFlex Unit Specification


Concrete Open/Closed Nom. Dimensions (in.) Gross Area/ Min. Block Weight Open
Block Class Cell L W H (sq. ft.) lbs lbs/sq. ft. Area %

30S Open 13 11.6 4.75 0.98 33 35 20


Typical Mat 50S Open 13 11.6 6 0.98 42 50 20
PLAN
40 Open 17.4 15.5 4.75 1.77 59 40 20
TYPICAL ARMORFLEX MAT
BACKFILL WITH 4000 P.S.I. NOT TO SCALE 50 Open 17.4 15.5 6 1.77 76 50 20
GROUT, CONCRETE OR
APPROVED EQUAL 70 Open 17.4 15.5 8.5 1.77 108 70 20
VARIES AREA OF COVERAGE
WASHER
CABLE
40L Open 17.4 23.6 4.75 2.58 97 40 20
X 50L Open 17.4 23.6 6 2.58 116 50 20
1
70L Open 17.4 23.6 8.5 2.58 174 70 20
CABLE SLEEVE N.T.S.
45S Closed 13 11.6 4.75 0.98 39 45 10
1
1 SITE SPECIFIC 55S Closed 13 11.6 6 0.98 50 55 10
GEOTEXILE
45 Closed 17.4 15.5 4.75 1.77 71 45 10
2 UNIT MIN.
Existing Subgrade 55 Closed 17.4 15.5 6 1.77 91 55 10
85 Closed 17.4 15.5 8.5 1.77 136 85 10
TOP OF SLOPE
STANDARD DETAIL
45L Closed 17.4 23.6 4.75 2.58 109 45 10
1' MIN. N.T.S.
A-JACKS UNITS 55L Closed 17.4 23.6 6 2.58 138 55 10
85L Closed 17.4 23.6 8.5 2.58 207 85 10
High Velocity Application Block Classes
Top of Slope - Standard Detail 40-T Open 17.4 15.5 4.75 1.77 58 40 20
H
50-T Open 17.4 15.5 6.00 1.77 75 50 20
70-T Open 17.4 15.5 8.50 1.77 109 70 20

A-Jacks (not to scale)A-JACKS UNITS


A-JACKS PLACEMENT: PROFILE
(NOT TO SCALE)
H

"L"

A-Jacks Placement Profile


A-JACKS PLACEMENT: PROFILE
(NOT TO SCALE) A-Jacks Unit Specification
"L"
A-JACKS L(FT) H(FT) WT (LBS)

AJ-24 2 1.5 78
AJ-48 4 3.0 629
L
AJ-72 6 4.5 2,120
AJ-96 8 6.0 5,022
L
AJ-120 10 7.5 9,699
A-Jacks Unit
B
3510 Model
ArmorLoc (not to scale) B

1515A7/8"
/8 1111 7/8"
/8
A
A A

H
ArmorLoc Unit Specification
SECTION A SECTION B
DIMENSIONS AND WEIGHTS B
N.T.S.
B
N.T.S.

Thickness H Gross Area/ Min. Block 4511 & 5011 Models


BLOCK (in.) Grid ft2 Weights Open Area % 15 /8
BB
11 /8

3510 4 1.0 30 25 15
157/8"
7/8 117/8
11 7/8"
A AA
4511 5.25 1.1 45 20
A
15 /8 11 /8

5011 6 1.1 50 20 HH

BB SECTION
SECTION A-A A SECTION
SECTION B-B B

*Open-cell block shown. Closed-cell block also available. N.T.S. N.T.S.

15

ArmorRoad (not to scale) 15 7/8 W


W 11 7/8

H 1515 7/8"

6

SECTION A-A SECTION B-B

FRONT VIEW Cable 6"


6

LL
FRONT VIEW Cable
ArmorRoad Unit Specification 18

MIN. UNIT Cable Tunnels 18"


18

BLOCK L W H WEIGHT
(LB/SF)
Pointe Dr.
Mat 18.00 15.60 6.00 60 SIDE VIEW Pointe Dr.
TOP VIEW SIDE VIEW

ArmorWedge (not to scale)


18.00

2.00

5.105

14.88
rs
to
pira
As
*Isometric View

ArmorWedge Unit Specification


Side View - Typical Block
UNIT DIMENSION UNIT WEIGHT SYSTEM WEIGHT UNIT
(IN.) (LBS/ FT2) (LBS/ FT2) COVERAGE (SF)
12x18 130-140 54-59 1.1875

ARMORTEC Minimum Physical Requirements per ASTM D6684


MIN. DENSITY MIN. COMPRESSIVE MAX WATER
(IN AIR) LBS/FT3 STRENGTH PSI ABSORPTION LBS/FT3

Ave. of 3 Units Individual Unit Ave. of 3 Units Individual Unit Ave. of 3 Units Individual Unit
130 125 4,000 3,500 9.1 11.7

www.ContechES.com 800-338-1122
2016 Contech Engineered Solutions LLC. All rights reserved.