stream type T supply T target FCp dH dTmin

1 hot 30 120 1.8 162


2 hot 60 100 4 160
3 cold 180 80 1 100
4 cold 130 40 2 180

ACTUAL TEMP. SHIFTED TEMP.


Ts Tt Ts Tt
C1 180 80 C1 185 85
C2 130 40 C2 135 45
H1 30 120 H1 35 125
H2 60 100 H2 65 105

Set up global temp.


no duplic. Setup int.
85 85 185 185 180
C1
185 185 135 135 130
45 45 125 125
C2
135 135 105 105 80
125 125 85 85
H1
35 35 65 65 40
105 105 45 45
H2
65 65 35 35
C1 C2
1 2
10

dT interv FCp H-C dH

50 -1 -50 deficif -50


10 -3 -30 deficif -50 -30
120 20 -1.2 -24 deficif -80 -24 -54
100 20 2.8 56 surplus -104 56 32
60 20 3.8 76 surplus -48 76 132
20 -0.2 -4 deficif 28 -4 72
30 10 1.8 18 surplus 24 18 14
42 18
H1 H2
1.8 4 Qh min 50
Qc min 18
0,0 pich = 135 oC