Professional Documents
Culture Documents
5266 Controls: Safety Exhaust (Dump)
5266 Controls: Safety Exhaust (Dump)
www.rosscontrols.com
G1
DM2 Monitoring:
The DM2 is a patented 3/2 normally closed valve (with an intermediate, lockout position)
distinguished by SERPAR Crossow passages with poppet and spool valving on the
main valve stems. This arrangement provides the valves outstanding ow characteristics
and an integrated monitoring capability with total memory. The valve provides dynamic
monitoring and dynamic memory.
Dynamic Monitoring means that all monitoring components change state on every valve
cycle. Should the valve elements cycle asynchronously, the valve will exhaust downstream
air and lock-out, prohibiting further operation.
Dynamic Memory within a monitoring system indicates that when a valve lock-out
occurs, the valve will retain the fault information regardless of air or electrical changes.
The DM2 system can only be reset by a dened operation/procedure, and will not
self-reset (turning the valve off and on) or reset when inlet air supply is removed and
re-applied. Such automatic resetting would conceal potential hazards from the operator.
Page
Remote
SERIES
Manual
4.63
DM2 D 2.17 2.17 2.8 4.63 20.22 G1.3 - G1.6
8.86
www.rosscontrols.com
Control Reliable Double Valves Safety Exhaust (Dump)
with Total Dynamic Monitoring & Complete Memory DM2 Series D
Choose your options (in red) to congure your valve model number.
DM2D D A 4 2 A 1 1
Thread Reset Type Status Indicator
BSPP D Revision Level Remote 1 Yes 1 3
1 2
NPT N Size 4, 8, 12, 30 A Solenoid 2 No X
N/A (no base) X Size 2 B Manual 4
Basic Size
Voltage* Simplied Schematic
2 2 %DVLF Port Size
Size Inlet Outlet 24 volts DC A
4 4 Valve CV Weight#
1/4 1/4 0 110 volts AC, 50 Hz;
8 5 2 B Basic Size 1-2 2-3 lb (Kg)
3/8 3/8 1 120 volts AC, 50/60 Hz
12 6 1/2 1/2 2
4 220 volts AC, 50/60 Hz C** 2 2.17 3.66 5 (2.3)
30 8 12 3/4 3
3/4 3/4 4 12 volts DC D 4 2.80 6.70 6.0 (2.8)
8 1 1 5 24 volts AC E 8 4.63 12.55 9.1 (4.2)
1 1 6 * For other voltages consult ROSS. 12 8.86 20.78 15.5 (7.1)
12 1 1 7
** 220 VAC not available in the U.S. 30 20.22 53.68 32.6 (14.8)
30 1 2 8 (OSHA regulations limit press control # Valve and base assembly with
Valve Only (less base) X voltage to no more than 120 volts AC). status indicator and solenoid reset.
Connectors ordered separately, refer to page G1.8. For other options, consult ROSS.
IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.
Online Version
Rev. 10/02/17 www.rosscontrols.com G1.3
Control Reliable Double Valves Valve Technical Data
with Total Dynamic Monitoring & Complete Memory DM2 Series D
Valve Dimensions inches (mm) SUB-BASE MODEL NUMBERS and
SUB-BASE SPECIFIC INFORMATION
View X
4.79 (121.6) 4.50 (114.3) (Base mounting hole pattern) Valve Port Size Sub-Base
Valve envelope
Status Weight
Basic Model
G1 Outlet Port
(Based in overall hole
dimnsions at left.) Size
Inlet Outlet
Number
Indicator lb (kg)
(Each Side)
10.89 0.22 (5.6)
1/4 1/4 1872C91 No 1.7 (0.8)
(276.7) (4 places)
7.90 1/4 1/4 1873C91 Yes 2.1 (1.0)
(200.8) 2
1.19 4.00 (101.6) 3/8 3/8 1874C91 No 1.7 (0.8)
Basic Size 2 (30.2) 2.99
0.82 10.32 (75.9) 3/8 3/8 1875C91 Yes 2.1 (1.0)
(262.2) 2.99
(20.9) (75.9) 4.00 (101.6)
1/2 1/2 1697C91 No 1.7 (0.8)
0.25
1.37 2.04 (6.4) 1/2 1/2 1698C91 Yes 2.3 (1.1)
(34.9) 2.04 (51.9) 4
Inlet Port (51.9) 1/2 3/4 1699C91 No 1.7 (0.8)
(Each Side)
Solenoid 0.25 0.57 (14.5) 1/2 3/4 1700C91 Yes 2.3 (1.1)
Reset (6.4) with Solenoid Reset
4.00 (101.6)
3/4 3/4 1701C91 No 3.6 (1.6)
3/4 3/4 1702C91 Yes 4.2 (1.9)
6.93 (176) 5.28 (134.1) View X 8
(Base mounting hole pattern) 1 1 1703C91 No 3.6 (1.6)
Valve envelope
(Based on overall
dimensions at left.)
1 1 1704C91 Yes 4.2 (1.9)
1 1 1705C91 No 6.2 (2.8)
0.97 1 1
(24.6) 3.68 (93.47)
1706C91 Yes 6.8 (3.1)
12
Basic Size 4 10.95 4.34 (110.2) 1 1 1707C91 No 6.2 (2.8)
(278.1) 0.16 (4.06)
1.32 (33.5) 9.44 1 1 1708C91 Yes 6.8 (3.1)
(239.8) 4.00 (101.6)
1.24 (31.5) 1 2 1709C91 No 12.0 (5.4)
Outlet Port
(Each Side) 0.65 30
X 2.74 (16.6) 1 2 1710C91 Yes 12.6 (5.7)
(69.6)
Inlet Port Solenoid * NPT port threads. For BSPP threads add a D
(Each Side) Reset
prex to the model number, e.g., D1872C91.
G Outlet Port
(Each Side)
2.08
(340.40)
0.57 (14.48)
(52.83) 1.59
Inlet Port 4.72 (119.89) (40.4)
(Each Side)
X 1.61
Solenoid (40.9)
Reset
1.95
(49.53) 0.50 (12.7)
16.87 (4 places)
(428.5)
1.16 (29.46)
Basic Size 30 3.34
9.73 (247.14)
(84.84) 16.56
(420.6)
Outlet Port
(Each Side) 2.56
(65.02) 6.14 (155.96)
Inlet Port
(Each Side) X 2.42 1.73
(61.5) (44)
Solenoid
Reset
Online Version
G1.4 Rev. 10/02/17
Control Reliable Double Valves Valve Operation
with Total Dynamic Monitoring & Complete Memory DM2 Series D
OUTLET
OUTLET
inlet poppets prevent air ow from crossover INLET
and exhaust poppets are fully closed. The outlet INLET
passages into the outlet chamber. Air pressure is then quickly pressurized, and pressure in the
acting on the inlet poppets and return pistons INLET inlet, crossovers, outlet, and timing chambers INLET
securely hold the valve elements in the closed are quickly equalized. De-energizing the pilots
position. (Air passages shown out of position quickly causes the valve elements to return to
and reset adapter omitted for clarity. the ready-to-run position.
Valve locked-out:
Whenever the valve elements operate in a sufciently asynchronous manner, either on actuation or de-actuation, the
valve will move to a locked-out position. In the locked-out position, one crossover and its related timing chamber will be B A
exhausted, and the other crossover and its related timing chamber will be fully pressurized. The valve element (side B)
that is partially actuated has pilot air available to fully actuate it, but no air pressure on the return piston to fully de-actuate
the valve element. Air pressure in the crossover acts on the differential of side B stem diameters creating a latching force. EXHAUST
EXHAUS
ST
OUTLET
Side A is in a fully closed position, and has no pilot air available to actuate, but has full pressure on the inlet poppet and OUTLET
return piston to hold the element in the fully closed position. INLET
Inlet air ow on side A into its crossover is restricted, and ows through the open inlet poppet on side B, through the
outlet into the exhaust port, and from the exhaust port to atmosphere. Residual pressure in the outlet is less than 1% INLET
of inlet pressure.
The return springs are limited in travel, and can only return the valve elements to the intermediate (locked-out) position.
Sufcient air pressure acting on the return pistons is needed to return the valve elements to a fully closed position.
Status Indicator:
The status indicator pressure switch will actuate when the main G
valve is operating normally, and will de-actuate when the main
valve is in the locked-out position or inlet pressure is removed.
This device is not part of the valve lockout function, but, rather,
only reports the status of the main valve.
Status indicator (optional) in normal ready-to-run position.
Online Version
Rev. 10/02/17 www.rosscontrols.com G1.5
Control Reliable Double Valves Valve Response Charts
with Total Dynamic Monitoring & Complete Memory DM2 Series D
The charts below represent the ll and exhaust times for each of the various sizes of DM2 Series D double valves. The ll times were measured
while raising (lling) the pressure in a volume from 0 to 30, 60, & 80 psi (0 to 2.1, 4.1, & 5.5 bar) with a 90 psi (6.2 bar) inlet pressure. Conversely, the
exhaust times were measured while lowering the pressure (exhausting) in a volume from 90 psi (6.2 bar) down to 90 to 60, 30, & 9 psi (4.1, 2.1, &
G1 0.6 bar). Exhausting tests performed with silencer installed.
Filling Exhausting
Basic Size 2
0.25 (15.25) 0.5 (30.5) 0.75 (45.75) 1 (61) 0.25 (15.25) 0.5 (30.5) 0.75 (45.75) 1 (61)
Volume litres (cubic inches) Volume litres (cubic inches)
Basic Size 4
Basic Size 8
Basic Size 12
G
Basic Size 30
Online Version
G1.6 Rev. 10/02/17
Safety Exhaust (Dump)
Preassembled Wiring Kits DM2 Series D
Solenoid Cables Status Indicator Cable
Preassembled Wiring Kits with EN connector with EN connector
NOT USED GRN/YEL
GROUND
Kit Number* Length
BRN
PIN 1 GRYY
GRY
4 BRN
Solenoid Connector PIN 2
G1
Connector Lighted Connector meters 2 1
Type /YEL
GRN/YEL 3 BLK
without Light 24 Volts DC 120 Volts AC (feet) GROUND
UND
BRN BLUE 3 BLK
2 1
2288H77 M12 5 (16.4)
3 4
3 4
2289H77 M12 10 (32.8) BLUE BLACK
These kits include 1 cable for the status indicator, and 3 cables with
connector plus a cord grip for each.
10 PIN MINI Cable These cables have a 10-pin MINI connector for connecting the J-Box kits above to the users control system.
Kits include one cable with connector and cord grip. Cable conductors are 18-gauge wire.
Kit Number Length meters (feet)
2253H77 3.66 (12) PIN # PIN # Wire Colors: Wire Colors:
1 +24 volts DC 6 - Orange Orange w/Black 7 8 1
2254H77 6.1 (20) 2 Common volts DC 7 Remote Reset Blue Red
6 9 10 2
3 - 8 - White w/Black Green/Yellow
2255H77 9.1 (30) 4 Solenoid A 9 Remote Valve Fault Light Red w/Black Black 5 3
4
2256H77 15.2 (50) 5 Solenoid B 10 Remote System OK Light Green w/Black White
5 4 3 2 1 (40)
(17) 1.6 Pressure switch available separately,
M12x1 0.7
MALE
3 5 4 Female see valve options.
2 1 M12x1
Male
IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.
Online Version
Rev. 10/02/17 www.rosscontrols.com G1.7
for Safety Exhaust (Dump)
Accessories & Options DM2 Series D
Electrical Connectors
Electrical Connector Model Number
G1 Electrical Connector Electrical Connector Cord Length Cord
Type meters (feet) Diameter Without Light Lighted Connector
Form
24 Volts DC 120 Volts AC
Prewired Connector (18 gauge) 2 (6) 6-mm 721K77 720K77-W 720K77-Z
Prewired Connector (18 gauge) 2 (6) 10-mm 371K77 383K77-W 383K77-Z
EN 175301-803
Form A Connector for threaded conduit
723K77 724K77-W 724K77-Z
(1/2 inch electrical conduit ttings)
Connector Only 937K87 936K87-W 936K87-Z
CAUTIONS: Do not use electrical connectors with surge suppressors, as this may increase valve response time when de-actuating the
solenoids.
Status Indicator
The Status Indicator pressure switch actuates when the valve is in a ready-to-run condition and
Model Number
de-actuates when the valve is in a lockout condition or when the inlet air pressure has been
670B94
removed. Although, the valves can be purchased with this option already installed, the Status
Indicator can be purchased separately.
Valves with the remote reset option require a small 3/2 reset valve and the installation of a 1/8 inch air line from the reset valve to the reset
port of the double valve. ROSS offers 3/2 normally closed valves with either manual or electric control that are suitable for this purpose.
Reset Valves
Description Model Number
Flush Pushbutton: Green 1223B1FPG
G Mushroom Button: Green 1223B1MBG
Direct Solenoid Model
Direct Solenoid Control for Line Mounting 1613B1020**
for Line Mounting:
W1413A1409** 1613B1020**
Direct Solenoid Control for Base Mounting
(Base: 516B91)
* NPT threads. For BSPP threads add a D prex to the model number, e.g., D1223B1FPG.
** Insert voltage code: W = 24 volts DC; Z = 110-120 volts AC, 50/60 Hz; e.g., 1613B1020W.
IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.
Online Version
G1.8 2017, ROSS CONTROLS. All Rights Reserved. Rev. 10/02/17
General Information
Standard Specications Solenoids
The standard specications for the products on each page of this All ROSS standard solenoids are rated for continuous duty (unless
catalog are given on the same page or referenced. For solenoid pilot noted otherwise) and will operate the valve within the air pressure
valves, models with internal pilot supply are listed. Most models are range specied in this catalog.
also available for use with external pilot supply or have a built-in pilot
Explosion-Proof Solenoid Pilot available, for more information
supply selector valve.
consult ROSS.
The products in this catalog are intended for use in industrial pneumatic
systems. Most products are adaptable to other uses and conditions not Voltage & Hertz
covered by the standard specications given in this catalog. Weights
When ordering a solenoid valve, also specify the desired solenoid
shown are approximate and are subject to change. Dimensions given,
voltage and hertz.
unless otherwise noted, are envelope dimensions (not for mounting).
Consult ROSS for further information. Voltage Types by Model Sufx Letter
ROSS products are designed to meet a number of industrial standards, Information or Technical Assistance
including the Canadian Standards Association (C.S.A.) guidelines. For additional information or application assistance concerning ROSS
For more information on specic product approvals, contact your local products, consult ROSS or your local ROSS distributor (see contact
distributor or ROSS. information on the back cover).
Order Placement
Online Version
10 Rev. 04/07/17
CAUTIONS, WARNINGS and STANDARD WARRANTY
PRE-INSTALLATION or SERVICE
1. Before servicing a valve or other pneumatic component, be 7. Only use lubricants which are compatible with materials
sure that all sources of energy are turned off, the entire pneumatic used in the valves and other components in the system.
system is shut off and exhausted, and all power sources are locked Normally, compatible lubricants are petroleum based oils with
out (ref: OSHA 1910.147, EN 1037). oxidation inhibitors, an aniline point between 180F (82C) and
2. All ROSS products, including service kits and parts, should 220F (104C), and an ISO 32, or lighter, viscosity. Avoid oils
be installed and/or serviced only by persons having training and with phosphate type additives which can harm polyurethane
experience with pneumatic equipment. Because any installation components, potentially leading to valve failure which risks human
can be tampered with or need servicing after installation, persons injury, and/or damage to property.
responsible for the safety of others or the care of equipment
must check every installation on a regular basis and perform all
AVOID INTAKE/EXHAUST RESTRICTION
necessary maintenance. 8. Do not restrict the air ow in the supply line. To do so could
3. All applicable instructions should be read and complied with reduce the pressure of the supply air below the minimum
before using any uid power system in order to prevent harm to requirements for the valve and thereby cause erratic action.
persons or equipment. In addition, overhauled or serviced valves 9. Do not restrict a valves exhaust port as this can adversely
must be functionally tested prior to installation and use. If you have affect its operation. Exhaust silencers must be resistant to clogging
any questions, call your nearest ROSS location listed on the cover
and must have ow capacities at least as great as the exhaust
of this document.
capacities of the valves. Contamination of the silencer can result
4. Each ROSS product should be used within its specication in reduced ow and increased back pressure.
limits. In addition, use only ROSS parts to repair ROSS products.
WARNING: ROSS expressly disclaims all warranties and
WARNING: Failure to follow these directions can adversely responsibility for any unsatisfactory performance
affect the performance of the product or result or injuries caused by the use of the wrong type,
in the potential for human injury or damage to wrong size, or an inadequately maintained silencer
property. installed with a ROSS product.
5. Dirt, scale, moisture, etc. are present in virtually every air system. 10. Mechanical power presses and other potentially hazardous
Although some valves are more tolerant of these contaminants than machinery using a pneumatically controlled clutch and brake
others, best performance will be realized if a lter is installed to mechanism must use a press control double valve with a monitoring
clean the air supply, thus preventing contaminants from interfering device. A double valve without a self-contained monitoring device
with the proper performance of the equipment. ROSS recommends should be used only in conjunction with a control system which
a lter with a 5-micron rating for normal applications. assures monitoring of the valve. All double valve installations
involving hazardous applications should incorporate a monitoring
6. All standard ROSS lters and lubricators with polycarbonate
system which inhibits further operation of the valve and machine in
plastic bowls are designed for compressed air applications only.
the event of a failure within the valve mechanism.
Do not fail to use the metal bowl guard, where provided, to
minimize danger from high pressure fragmentation in the event of ENERGY ISOLATION/EMERGENCY STOP
bowl failure. Do not expose these products to certain uids, such
as alcohol or liqueed petroleum gas, as they can cause bowls to 11. Per specications and regulations, ROSS L-O-X and L-O-X
rupture, creating a combustible condition, hazardous leakage, and with EEZ-ON operation products are dened as energy isolation
the potential for human injury or damage to property. Immediately devices, NOT AS EMERGENCY STOP DEVICES.
replace a crazed, cracked, or deteriorated bowl. When bowl gets
dirty, replace it or wipe it with a clean dry cloth.
All products sold by ROSS CONTROLS are warranted for a one-year period
[with the exception of all Filters, Regulators and Lubricators (FRLs) which are
STANDARD WARRANTY warranted for a period of seven years] from the date of purchase to be free of
defects in material and workmanship. ROSS obligation under this warranty is
limited to repair or replacement of the product or refund of the purchase price paid solely at the discretion of ROSS and provided
such product is returned to ROSS freight prepaid and upon examination by ROSS is found to be defective. This warranty becomes
void in the event that product has been subject to misuse, misapplication, improper maintenance, modication or tampering.
THE WARRANTY EXPRESSED ABOVE IS IN LIEU OF AND EXCLUSIVE OF ALL OTHER WARRANTIES AND ROSS EXPRESSLY
DISCLAIMS ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED WITH RESPECT TO MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. ROSS MAKES NO WARRANTY WITH RESPECT TO ITS PRODUCTS MEETING THE PROVISIONS
OF ANY GOVERNMENTAL OCCUPATIONAL SAFETY AND/OR HEALTH LAWS OR REGULATIONS. IN NO EVENT IS ROSS LIABLE TO
PURCHASER, USER, THEIR EMPLOYEES OR OTHERS FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES WHICH MAY RESULT
FROM A BREACH OF THE WARRANTY DESCRIBED ABOVE OR THE USE OR MISUSE OF THE PRODUCTS. NO STATEMENT OF
ANY REPRESENTATIVE OR EMPLOYEE OF ROSS MAY EXTEND THE LIABILITY OF ROSS AS SET FORTH HEREIN.
Online Version
Rev. 04/07/17 www.rosscontrols.com 11
ROSS CONTROLS
U.S.A.
Tel: +1-248-764-1800
Customer Svs. 1-800-GET-ROSS
(438-7677)
Technical Svs. 1-888-TEK-ROSS
(835-7677)
sales@rosscontrols.com
www.rosscontrols.com
ROSS UK Ltd.
United Kingdom
Tel: +44-1543-671495
sales.uk@rosscontrols.com
www.rossuk.co.uk
ROSS CANADA Other literature is available for engineering, maintenance, and service requirements. If you need
Canada SURGXFWVRUVSHFLFDWLRQVQRWVKRZQKHUHSOHDVHFRQWDFW5266RU\RXU5266GLVWULEXWRU7KH\ZLOO
Tel: +1-416-251-7677 be happy to assist you in selecting the best product for your application.
sales@rosscanada.com
www.rosscanada.com
6077170 CANADA INC.
AN INDEPENDENT REPRESENTATIVE For a current list of countries and local distributors, visit ROSS website at www.rosscontrols.com.
U.S.A. - Content subject to change. 2017, ROSS CONTROLS. All Rights Reserved. Form ROSS-DMPress
Online version only...