Professional Documents
Culture Documents
Design Hydrostatics Report For Chemical Tanker
Design Hydrostatics Report For Chemical Tanker
Lateral plane
Lateral area 1241.6 (m 2)
Longitudinal center of effort 86.082 (m)
Vertical center of effort 3.836 (m)
The following layer properties are calculated for both sides of the ship
Location Area Thickness Weight LCG TCG VCG
(m 2) (m) (tonnes) (m) (m) (m)
Hull 8632.3 0.000 0.0 84.228 0.000 (CL) 4.777
Sectional areas
Location Area Location Area Location Area Location Area Location Area
(m) (m 2) (m) (m 2) (m) (m 2) (m) (m 2) (m) (m 2)
0.000 0.0 35.000 181.0 70.000 219.2 105.000 222.4 140.000 182.9
5.000 5.2 40.000 193.0 75.000 220.4 110.000 221.9 145.000 161.7
10.000 33.2 45.000 201.2 80.000 221.5 115.000 221.1 150.000 133.6
15.000 65.3 50.000 207.0 85.000 222.1 120.000 219.4 155.000 99.0
20.000 100.5 55.000 211.4 90.000 222.5 125.000 215.8 160.000 60.0
25.000 134.1 60.000 214.7 95.000 222.6 130.000 209.2 165.000 23.4
30.000 161.1 65.000 217.1 100.000 222.6 135.000 198.4 170.000 0.0
15-09-2017 1
Design hydrostatics report
Sectional areas
220
210
200
190
180
170
160
150
140
130
Area (m2)
120
110
100
90
80
70
60
50
40
30
20
10
0
Location (m)
NOTE 1: Draft (and all other vertical heights) is measured from base Z=0.000
NOTE 2: All calculated coefficients based on actual dimensions of submerged body.
15-09-2017 2