Professional Documents
Culture Documents
A0201 T1
A0201 T1
A0201 T1
RL RELATIVE LEVEL
4050 90 9390 155 4665 160 2200 160 6000 3675 HYD FIRE HYDRANT
WALL SETOUT GI GRATED INLET
WALL SETOUT
WALL TO STRUCTURAL UNITS FROM GR01 SERVICES PLENUM IO INSPECTION OPENING
200 ENG'S DETAIL AT HIGH LEVEL A0601 FOR CARPARK
89 36' 30.83 EXHAUST VENTILATION GPO GENERAL POWER OUTLET
500
NBN
970
SPOON DRAIN SPOON DRAIN
WT35
G G G G G B04 AREA OF 30mm SETDOWN TO SLAB
2200
COF3 UNITS FROM
BIKE STORAGE -
2800
G01AND G02 AT GENERAL PLAN NOTES
2375
R R R R R
REFER TO FFE LIFT SHAFT HIGH LEVEL
SCHEDULE OUTLINE OF SMOKE LOBBY
33
1 REFER TO FINISHES LEGEND SCHEDULE FOR ALL
STAIRS OVER WT05 B06
90
A0501 WT31 FINISHES CODE DESCRIPTION
16.
COF1
525
ST
2
1400
REFER TO DOOR TYPE PLAN LEGEND FOR DOOR
APT G02 TYPES AND SPECIFICATION
FHR SAFE
1345
WT01A APT 201 APT 202 APT G01 APT G02 APT 101
WT31 REFER TO CIVIL ENGINEER'S DWGS FOR IN GROUND /
BOL1 ZONE
0
5400 x 2700 5400 x 2700 1500 1000 4900 x 2950 4900 x 2950 4900 x 3200 FLOOR DRAINAGE SPECIFICATION AND LAYOUT
106
25'
BOL1 W FIXED GLAZED WINDOW AT
100
FW3 HIGH LEVEL FOR LIGHTING. REFER TO STURUCTURAL ENGINEER FOR COLUMN'S
ST GRATED PIT TO CIVIL
28
SIZES
APT G03 2445 90 REFER DWG A0401 FOR
STEEL CAGE STORAGE ENG'S SPECIFICATION
16.21
0
LOCATION
170
WALL - REFER TO FIXTURE
1120 SHOP GR01 BASEMENT CL
AND FITTINGS SCHEDULE
6110
FW3 ST 5400 x 2700 B01
APT 201
5
WALL LOUVRE ABOVE
5290
129
SSL 42.000
IN
DRIVEWAY RAMP CAR SPACE TO BE INSTALLED ON
RA
CAR PARKING SPACES: 9
180 06'
2
RAILS TO ALLOW INDEPENDENT GRATED PIT TO CIVIL
ND
A0501
5 ACCESS TO REAR BAYS. REFER COF2 ENG'S SPECIFICATION
OO
1900
ST A0904 WT31
TO FF&E SCHEDULE
SP
WT31
APT 202 WT31
SPOON DRAIN
DP FW3
825 1135 DP
3
RETENTION TANK TO CIVIL WATER TANK ROOM
1635
100mm HIGH SIDE KERB APT 103 APT 104
ENGINEERS DOCUMENTATION 2 X SLIMLINE WATER TANKS TG1 APT 102 4900 x 2950 4900 x 3200
COF3 WT35
REFER TO SERVICE 4900 x 2900
4
SPOON DRAIN
RAMP 1:4 RAMP 1:8
3000
ENGINEER'S DOCUMENTATION COF3 JUNCTION PIT TO
SPOON DRAIN, REFER CIVIl ENG'S DETAILS
TO CIVIL ENG'S
DOCUMENTATION
FW3
3820
OVERHEAD OVERHEAD OVERHEAD JBA CONSULTING ENGINEERS
STORAGE STORAGE STORAGE BUILDING E5 63-85 TURNER STREET
42.72AHD PORT MELBOURNE 3207 AUSTRALIA
000'
270 14' 28.69 T +61 3 9646 9144
1.50
200 1320 FW3 SPOON DRAIN FW3 www.jba.com.au
4
A0904 5
A-1 EASEMENT
270 05' 9.88 3.05
2575 200 9890 150 25160
WALL SETOUT IRWIN CONSULT
LEVEL 3, 289 WELLINGTON PARADE
WALL SETOUT
EAST MELBOURNE 3002 AUSTRALIA
T +61 3 9622 9700
www.irwinconsult.com.au
GRID
1 BASEMENT FLOOR
A0401 1 : 100
REVISIONS
T1 16.04.07 TENDER ISSUE SRM
A B C D E
2800
PROJECT :
PF2
PF3 98 HIGH ST, KEW
PF1
2
PROJECT NUMBER :
12134
DRAWING TITLE :
6110
B01 CONCRETE PROFILE
1000 1650 SSL 42.000
CONCRETE STRIP FOOTING
TO STRUCTURAL ENGINEER'S
SPECIFICATION CLIENT :
160
DRAWN BY : CHECKED BY :
3
475
SRM AF
CL
PF3
1635
WT35 100mm HIGH SIDE KERB DATE :
RAMP 1:4.5 RAMP 1:8
4 SEPTEMBER 2015
WT37 WATER TANK ROOM
B03 SCALE :
1 : 100 @ A1
3820
DRAWING NUMBER : REVISION :
A0201 T1
5
150 MGS ARCHITECTS PTY LTD
ABN 13006 488 302
10-22 MANTON LANE
MELBOURNE 300 AUSTRALIA
GRID
T +61 3 9670 1800
MGSARCHITECTS.COM.AU
6/04/2016 6:21:27 PM