Typical Floor Beam

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 13

Project Commercial Building Date Jul-05

Description Typical Floor Beam Design By


Chkd

Typical Floor Beam - TFB1AS1

0.5 d = 0.465 m

0.3
Negative Moment 117.254 kn-m
Positive Moment 85.592 kn-m
Shear 77.433 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Positive Reinforcement


m = 23.02 m = 23.02
Rn = 1807.5924 Rn = 1319.49
r = 0.0076 r = 0.005393
As = 0.00106 As = 0.00075
f = 20 f = 20
No = 2 No = 2
f = 20 f = 16
No = 2 No = 1
As prvd = 0.00125664 As prvd = 0.0008
Capacity = 136.63 Capacity = 93.72
Reserve = 16.53% Reserve = 9.50%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 20.02
k1 = 1.450
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.61 m
Vc = 57.41 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB1AS2

0.5 d = 0.465 m

0.3
Negative Moment 158.13 kn-m
Posetive Moment 73.446 kn-m
Shear 65.05 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 2437.73847 Rn = 1132.247
r = 0.0107 r = 0.004582
As = 0.00149 As = 0.00064
f = 20 f = 20
No = 2 No = 2
f = 20 f = 16
No = 3 No = 1
As prvd = 0.0015708 As prvd = 0.0008
Capacity = 165.85 Capacity = 93.72
Reserve = 4.88% Reserve = 27.61%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 3.18
k1 = 1.563
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 3.83 m
Vc = 61.87 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB1AS3

0.5 d = 0.465 m

0.3
Negative Moment 155.402 kn-m
Posetive Moment 70.571 kn-m
Shear 119.405 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 2395.68351 Rn = 1087.925
r = 0.0104 r = 0.004392
As = 0.00146 As = 0.00061
f = 20 f = 16
No = 2 No = 2
f = 20 f = 16
No = 3 No = 2
As prvd = 0.0015708 As prvd = 0.0008
Capacity = 165.85 Capacity = 91.09
Reserve = 6.72% Reserve = 29.07%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 57.54
k1 = 1.563
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.21 m
Vc = 61.87 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB2AS1

0.5 d = 0.465 m

0.3
Negative Moment 168.339 kn-m
Posetive Moment 86.715 kn-m
Shear 70.144 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 2595.12082 Rn = 1336.802
r = 0.0115 r = 0.005469
As = 0.00160 As = 0.00076
f = 20 f = 20
No = 2 No = 2
f = 20 f = 16
No = 4 No = 1
As prvd = 0.00188496 As prvd = 0.0008
Capacity = 193.10 Capacity = 93.72
Reserve = 14.71% Reserve = 8.08%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 3.82
k1 = 1.676
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 3.19 m
Vc = 66.33 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB2AS2

0.5 d = 0.465 m

0.3
Negative Moment 159.125 kn-m
Posetive Moment 90.532 kn-m
Shear 83.219 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 2453.07743 Rn = 1395.645
r = 0.0107 r = 0.005728
As = 0.00150 As = 0.00080
f = 20 f = 20
No = 2 No = 2
f = 20 f = 16
No = 3 No = 1
As prvd = 0.0015708 As prvd = 0.0008
Capacity = 165.85 Capacity = 93.72
Reserve = 4.23% Reserve = 3.53%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 21.35
k1 = 1.563
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.57 m
Vc = 61.87 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB3S1

0.5 d = 0.465 m

0.3
Negative Moment 3.446 kn-m
Posetive Moment 3.446 kn-m
Shear 4.595 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 53.1236752 Rn = 53.12368
r = 0.0002 r = 0.000204
As = 0.00003 As = 0.00028
f = 16 f = 12
No = 2 No = 2
f = 12 f = 12
No = 0 No = 1
As prvd = 0.00040212 As prvd = 0.0003
Capacity = 47.16 Capacity = 40.01
Reserve = 1268.57% Reserve = 1060.93%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.144
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 45.29 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB3S2

0.5 d = 0.465 m

0.3
Negative Moment 153.018 kn-m
Posetive Moment 59.681 kn-m
Shear 51.036 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 2358.93167 Rn = 920.0447
r = 0.0103 r = 0.003683
As = 0.00143 As = 0.00051
f = 20 f = 16
No = 2 No = 2
f = 20 f = 12
No = 3 No = 1
As prvd = 0.0015708 As prvd = 0.0005
Capacity = 165.85 Capacity = 59.84
Reserve = 8.39% Reserve = 0.27%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.563
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 61.87 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB3S3

0.5 d = 0.465 m

0.3
Negative Moment 150.455 kn-m
Posetive Moment 61.13 kn-m
Shear 31.032 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 2319.42036 Rn = 942.3825
r = 0.0101 r = 0.003777
As = 0.00140 As = 0.00053
f = 20 f = 16
No = 2 No = 2
f = 20 f = 12
No = 3 No = 2
As prvd = 0.0015708 As prvd = 0.0006
Capacity = 165.85 Capacity = 72.27
Reserve = 10.23% Reserve = 18.22%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.563
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 61.87 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB4AS1

0.5 d = 0.465 m

0.3
Negative Moment 3.446 kn-m
Posetive Moment 3.446 kn-m
Shear 4.595 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 53.1236752 Rn = 53.12368
r = 0.0002 r = 0.000204
As = 0.00003 As = 0.00028
f = 12 f = 12
No = 2 No = 2
f = 12 f = 12
No = 0 No = 1
As prvd = 0.00022619 As prvd = 0.0003
Capacity = 26.93 Capacity = 40.01
Reserve = 681.38% Reserve = 1060.93%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.081
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 42.79 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB4AS2

0.5 d = 0.465 m

0.3
Negative Moment 107.39 kn-m
Posetive Moment 77.664 kn-m
Shear 46.264 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 1655.52858 Rn = 1197.271
r = 0.0069 r = 0.004862
As = 0.00096 As = 0.00068
f = 20 f = 16
No = 2 No = 2
f = 16 f = 16
No = 2 No = 2
As prvd = 0.00103044 As prvd = 0.0008
Capacity = 114.37 Capacity = 91.09
Reserve = 6.50% Reserve = 17.28%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.369
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 54.20 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB4AS3

0.5 d = 0.465 m

0.3
Negative Moment 103.251 kn-m
Posetive Moment 53.466 kn-m
Shear 34.368 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 1591.72159 Rn = 824.234
r = 0.0066 r = 0.003284
As = 0.00092 As = 0.00046
f = 20 f = 16
No = 2 No = 2
f = 16 f = 12
No = 2 No = 1
As prvd = 0.00103044 As prvd = 0.0005
Capacity = 114.37 Capacity = 59.84
Reserve = 10.77% Reserve = 11.93%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.369
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 54.20 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB4AS4

0.5 d = 0.465 m

0.3
Negative Moment 130.875 kn-m
Posetive Moment 44.558 kn-m
Shear 33.101 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 2017.57429 Rn = 686.9079
r = 0.0086 r = 0.002718
As = 0.00120 As = 0.00038
f = 20 f = 12
No = 2 No = 2
f = 20 f = 12
No = 2 No = 2
As prvd = 0.00125664 As prvd = 0.0005
Capacity = 136.63 Capacity = 52.83
Reserve = 4.40% Reserve = 18.56%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.450
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 57.41 kn Max S = 0.180 m Use 0.180
Project Commercial Building Date Jul-05
Description Typical Floor Beam Design By
Chkd

Typical Floor Beam - TFB4AS5

0.5 d = 0.465 m

0.3
Negative Moment 95.315 kn-m
Posetive Moment 95.923 kn-m
Shear 47.81 kn

Calculate Reinforcement

Concrete - Grade C-25 Steel


Fck 20,000 kpa [EBCS 2 Table 2.3] Fyk 300,000 kpa
Fctk 1,500 kpa [EBCS 2 Table 2.4] PS 1.15
PS Factor 1.5 [EBCS 2 Table 3.1] Fyd 260,870 kpa
Fcd 11333.33 kpa Es 200,000 kpa
Fctd 1,000 kpa r (min) = 0.002
Ecm 29,000 kpa [EBCS 2 Table 2.5] r (max) = 0.0165

f Mu
req =
1
m [
1 1
2 mR n
f yd ] m=
f
yd

cd
Rn =
bd 2

Negative Reinforcement Posetive Reinforcement


m = 23.02 m = 23.02
Rn = 1469.37989 Rn = 1478.753
r = 0.0061 r = 0.006096
As = 0.00084 As = 0.00085
f = 20 f = 20
No = 2 No = 2
f = 16 f = 16
No = 2 No = 2
As prvd = 0.00103044 As prvd = 0.0010
Capacity = 114.37 Capacity = 114.37
Reserve = 19.99% Reserve = 19.23%

Shear Capacity of Concrete Design Shear Reinforcement


A v df yd
V c=0 .25 f ctd k 1 k 2 b w d s=
Vs Vs = 0.00
k1 = 1.369
k2 = 1.135 Use Dia 8 Av = 0.000101
s = 0.20 m
Vc = 54.20 kn Max S = 0.180 m Use 0.180

You might also like