Green Felt sloping roof

Half round P.V.C gutter


fixed to facia board,
connected to R.W.D.P.
discharging into gully

Timber Cladding on
blockwork walls
Brickwork below DPC
set above 150mm
ground DPM to lap to
DPC

Ground level

1200mm
1200mm Proposed Rear Elevation

Sports p c table
equipment
/weights

Snooker/pools Table

Rowing
Outbuilding Summer house,
Gym,Games room
Half round P.V.C gutter
fixed to facia board,
connected to R.W.D.P.
discharging into garden

Bicycle Treadmill Stacking table tennis top Toilet


New Wooden cladding

Brickwork below DPC


set above 150mm
ground DPM to lap to
DPC
1200mm

Ground level

Proposed Front Elevation


Proposed Ground Floor Plan T.M.D.S.Limited
Architectural and Planning Consultancy
Mobile : 07958002357

CLIENT'S:
0 1 2 3 4 5 6 7 8 9 10m Mr Satishbhai

Scale 1: 50 PROPOSED DEVELOPMENT:


14 Westward Way Kenton
Harrow HA3 0SE
JOB No: 270 SCALE: DATE:
GENERAL NOTES : Do not scale from this drawing, any dimensions shown are indicative only and are subject to verification on site. This drawing to be read in conjunction with all other Architect's and Engineer's drawings, Structural Engineers calculations and any specialist supplier's drawings. 1: 50 November 2013
AGENT will not be responsible for the contract after having obtained planning permission and/ or building regulation approvals and that there can be no guarantee that planning permission or building regulation will be obtained. any works which are started before approvals will be at owners risk. no responsibility will be taken for works which are unforeseen and for any
subsequent alterations made which are beyond the control of the agent. This Set of drawings is to be submit to planning and/or building control Approval Only. AutoCAD Files do not from part of the fee DRG No: 1/R1 ISSUE: Planning Approval
Green Felt sloping roof

Half round P.V.C gutter


fixed to facia board,
connected to R.W.D.P.
14
discharging into gully
3000

2500

Timber Cladding on
blockwork walls
Brickwork below DPC
set above 150mm
ground DPM to lap to
DPC

RE
GE
Ground level

NT
1

CL
OS
Proposed Side Elevation

E
25

17
19
N
Green Felt sloping roof
9
26
AY
R DW
WA
ST
Half round P.V.C gutter WE
fixed to facia board, 14
connected to R.W.D.P.
3000

discharging into gully


2500

Timber Cladding on
blockwork walls 1200mm 1200mm
Brickwork below DPC
set above 150mm
ground DPM to lap to
DPC Location Plan
Ground level
Scale : 1:1250

1200mm
Proposed Other Side Elevation

Side Plan Scale : 1:200

T.M.D.S.Limited
Architectural and Planning Consultancy
Mobile : 07958002357

CLIENT'S:
Mr Satishbhai
PROPOSED DEVELOPMENT:
14 Westward Way Kenton
Harrow HA3 0SE
JOB No: 270 SCALE: DATE:
GENERAL NOTES : Do not scale from this drawing, any dimensions shown are indicative only and are subject to verification on site. This drawing to be read in conjunction with all other Architect's and Engineer's drawings, Structural Engineers calculations and any specialist supplier's drawings. 1: 50 November 2013
AGENT will not be responsible for the contract after having obtained planning permission and/ or building regulation approvals and that there can be no guarantee that planning permission or building regulation will be obtained. any works which are started before approvals will be at owners risk. no responsibility will be taken for works which are unforeseen and for any
subsequent alterations made which are beyond the control of the agent. This Set of drawings is to be submit to planning and/or building control Approval Only. AutoCAD Files do not from part of the fee DRG No: 2/R1 ISSUE: Planning Approval