Professional Documents
Culture Documents
Capacity Check of Bolt
Capacity Check of Bolt
Note - Negative (-) sign indicates Hogging Bending Moment and Positive (+) sign indicates
Sagging Bending Moment.
Mx*, My* are the resistive stress resultants per unit width in the reinforcement direction
required for design.
For bottom reinforcement: For Top Reinforcement:
Design Calculation
d required= #VALUE! 102.6 mm
d provided= 234 mm Ok
Check in Shear
SQX= 0.292 N/mm2
pt= 0.573 %
tc= 0.538 N/mm2
Ok
Note - Negative (-) sign indicates Hogging Bending Moment and Positive (+) sign indicates
Sagging Bending Moment.
Mx*, My* are the resistive stress resultants per unit width in the reinforcement direction
required for design.
For bottom reinforcement: For Top Reinforcement:
Design Calculation
d required= #VALUE! 129.1 mm
d provided= 244 mm Ok
Check in Shear
SQX= 0.284 N/mm2
pt= 0.549 %
tc= 0.529 N/mm2
Ok
Note - Negative (-) sign indicates Hogging Bending Moment and Positive (+) sign indicates
Sagging Bending Moment.
Mx*, My* are the resistive stress resultants per unit width in the reinforcement direction
required for design.
For bottom reinforcement: For Top Reinforcement:
Design of Slab
Data
Grade of Concrete= M 40
Grade of Steel= Fe 500
Clear Cover= 40 mm
Thickness of Slab= 250 mm
Mx+Mxy= Max Mx 37.606 Max Mxy 20.325 57.931 KN-m/m
Mx-Mxy= 17.281 KN-m/m
My+Mxy= Max My 76.607 Max Mxy 20.325 96.932 KN-m/m
My-Mxy= 56.282 KN-m/m
SQX= 0.36 N/mm2
SQY= 0.694 N/mm2
Design Calculation
d required= #VALUE! 135.0 mm
d provided= #VALUE! 202 mm Ok
Check in Shear
SQX= 0.36 N/mm2
pt= 0.995 %
tc= 0.675 N/mm2
Ok
Note - Negative (-) sign indicates Hogging Bending Moment and Positive (+) sign indicates
Sagging Bending Moment.
Mx*, My* are the resistive stress resultants per unit width in the reinforcement direction
required for design.
For bottom reinforcement: For Top Reinforcement:
Design Calculation
d required= #VALUE! 134.8 mm
d provided= #VALUE! 252 mm Ok
Check in Shear
SQX= 0.442 N/mm2
pt= 0.798 %
tc= 0.618 N/mm2
Ok
Note - Negative (-) sign indicates Hogging Bending Moment and Positive (+) sign indicates
Sagging Bending Moment.
Mx*, My* are the resistive stress resultants per unit width in the reinforcement direction
required for design.
Design of Slab
Data
Grade of Concrete= M 40
Grade of Steel= Fe 500
Clear Cover= 45 mm
Thickness of Slab= 250 mm
Mx+Mxy= Max Mx- 41.392 Max. Mxy- 13.749 55.141 KN-m/m
My+Mxy= Max My- 18.736 Max. Mxy- 13.749 32.485 KN-m/m
SQX= 0.196 N/mm2
SQY= 0.262 N/mm2
Design Calculation
d required= #VALUE! 101.8 mm
d provided= #VALUE! 197 mm Ok
Check in Shear
SQX= 0.196 N/mm2
pt= 0.379 %
tc= 0.451 N/mm2
Ok
Note - Negative (-) sign indicates Hogging Bending Moment and Positive (+) sign indicates
Sagging Bending Moment.
Mx*, My* are the resistive stress resultants per unit width in the reinforcement direction
required for design.
For bottom reinforcement: For Top Reinforcement:
Design Calculation
d required= #VALUE! 61.9 mm
d provided= #VALUE! 202 mm Ok
Check in Shear
SQX= 0.14 N/mm2
pt= 0.664 %
tc= 0.572 N/mm2
Ok
Note - Negative (-) sign indicates Hogging Bending Moment and Positive (+) sign indicates
Sagging Bending Moment.
Mx*, My* are the resistive stress resultants per unit width in the reinforcement direction
required for design.
For bottom reinforcement: For Top Reinforcement:
Data
Grade of Concrete= M 40
Grade of Steel= Fe 500
Clear Cover= 40 mm
Thickness of Slab= 300 mm
Mx+Mxy= Max Mx 43.859 Max Mxy 24.137 67.996 KN-m/m
Mx-Mxy= 19.722 KN-m/m
My+Mxy= Max My 85.101 Max Mxy 24.137 109.238 KN-m/m
My-Mxy= 60.964 KN-m/m
SQX= 0.301 N/mm2
SQY= 0.374 N/mm2
Design Calculation
d required= #VALUE! 143.3 mm
d provided= 242 mm Ok
Check in Shear
SQX= 0.301 N/mm2
pt= 0.865 %
tc= 0.638 N/mm2
Ok
SQY= 0.374 N/mm2
pt= 0.598 %
tc= 0.548 N/mm2
Ok
ihgcuisahCDKL LKWNJCFKLMW;L,C