Nexera-i
Prominence-i
-Series
innovative
Realization of Advanced Laboratory
ICM (Interactive Communication Mode) to free operators from the laboratory
Remote monitoring regardless of operating environment
Maximum reliability and stability
Dual temp-control with TC-Optics and flow cells unaffected by room temperature fluctuation
intuitive
Achieving Easier Operation
Unified graphical user interface between system and workstation
Create analytical sequences on visualized vial positions: Quick batch function
intelligent
Smart Features Increase Work Efficiency
Automation of a number of routine analysis procedures
Migrate existing methods from either Shimadzu or non-Shimadzu systems
First, on the App store or on the When the application is launched, <Notifiaction concerning communication fee>
Google Play Store, please search AR information will be retrieved The use of the xAR application is
for XAR then download the from the QR code. totally free. However, application
application. Please keep this page open then download and packet communication
hold on this page with your fees for browsing content are at the
XAR smartphone. charge of the customer.
From HPLC to UHPLC
Extensive Lineup of Shimadzu LCs
Shimadzu's extensive LC lineup fulfills a wide range of analytical needs, from conventional to
ultra-high speed analysis. With scalable column size and packing material particle size, Shimadzu
can provide an LC system most appropriate for your applications.
Conventional Ultra-high speed/High-separation
Packing material particle size (m) 10 ~ 3 3~2 <2
Column size (mm) ~ 250 ~ 75 ~ 150
Typical column Shim-pack VP Shim-pack XR Shim-pack XR II Shim-pack XR III
Prominence / Prominence-i
Nexera XR / Nexera-i
Nexera X2
Routine Analysis
Easy Operation
4
The flagship UHPLC system supporting columns with
sub-2 m micro-particle packing materials, realizing both
ultra-high speed and ultra-high separation. Excellent
reproducibility of low injection volume and ultra-low
carryover ensures reliable data, even with ultra-sensitive
LC/MS/MS methods.
All-round LC
Expandability
LC Systems 5
innovative
Realization of Advanced Laboratory
Method edit
Start auto purge
Create batch file
Start analysis
6
Laboratory
With the i-Series and LabSolutions, Shimadzu offers a new relationship between operators and
analytical instruments. The data acquired by i-Series featuring ICM is sent to the data center via the
LabSolutions network and managed uniformly by a server. Confirm analytical results from your
C omm
room. Use a smart device to monitor the current system status and chromatograms from anywhere LabSolutions
utions
ti s
Server
in the facility.
u
e
nic
fic
at
Of
io
n
Ar
ea
LC Systems 7
innovative
Maximum reliability and stability
Fundamental functions assure analysis results
8
Refined Usability
Control panel with a color LCD touch
panel allows anyone to operate the
instrument, regardless of experience level.
Easily and reliably perform routine
maintenance following onscreen instructions.
Displays Chromatogram
in Real Time
The chromatogram real-time monitor
allows the user to immediately confirm the
success or failure of data, even in a
computer-less laboratory environment.
Quaternary Solvent
Delivery Unit
A 10 L micro plunger ensures accurate
quaternary gradient delivery. Optional
reservoir switching valve further extends the
solvent selection to seven so that the solvent
for the flow path rinsing can be set.
LC Systems 9
innovative
Shimadzu Quality Means Reliability
Excellent Baseline Stability: Dual-Temp Control with TC-Optics and Flow Cells
In addition to the temperature control function in flow cells, hardly affected by room temperature fluctuation, ensures
the i-Series employs new temperature control technology for high precision of validation and quantitation tests
detector optical systems, known as TC-Optics (Temperature on trace components.
Controlled Optics). Measurement with a stable baseline,
C
mAU
35
40 Room Temp. 30
30
25
10
Prominence-i (UV)
Fluctuation range: approx. 1.3 mAU
0
Area(x10 6)
6.0
Butylparaben R2=0.9999980
Injection Area Reproducibility
5.0
Volume (L) (%RSD)
1 0.076 3.0
5 0.020
2.0
10 0.006
1.0
50 0.006
10
Enhancing Multi-Analyte Processing
When analyzing a large number of analytes, it is crucial to about 14 seconds, the i-Series achieves processing speeds
reduce the time between analyses, specifically the time more than twice as fast as previous Shimadzu systems, and
before the next sample injection. With an injection cycle of almost three times faster than other vendors' systems.
20 iinjections
20 njje
n jjec
ecti
e cttions
tion
io
ons
ns / 1
100m
min
iin
n 15 iinj
15 injections
njje
n jjec
ecti
ec
ections
e ctio
tion
tti
io
ons
onns / 1
100m
min
iin
n
5.0 7.5 10.0 12.5 min 5.0 7.5 10.0 12.5 min
i-Series
41 injections
41 in
njjjec
ect
ec
e ctio
ons
onns / 1
100 min
miin
n
1250
40
1000 20
0
750 0.9 1.0 1.1 min
500
250
LC Systems 11
intuitive
The combination of i-Series and LabSolutions brings about
Achieving Easier Operation changes in the laboratory and office. Uniform graphical user
interfaces between system and workstation allow intuitive
operations regardless of experience level and increase the
operation availability of the i-Series. The browser functions in
LabSolutions bring rapid processing of large amount of data,
realtime statistical calculation and easy confirmation of anomalous
values, enabling more efficient data processing.
12
Laboratory
C omm
LabSolutions
utions
ti s
Server
u
e
nic
fic
at
Of
io
n
Ar
ea
LC Systems 13
intelligent
Smart Features Increase Work Efficiency
T h e i - S e r i e s sa ve s l a b o p e r a t o r s t i m e a n d e n e r g y. Co m b i n ed
w i t h t h e La b S o l u t i o n s a u t o m a t e d f u n ct i o n s, i t r e l i ab l y
co m p l e t e s a n a l yse s u n d e r sp e ci f i e d p r o ce d u r e s. I n ad d i t i o n ,
t h e E - m a i l n o t i f i ca t i o n f e a t u r e a l l o w s yo u t o f o cu s o n o t h er
w o r k , w i t h o u t w o r r yi n g a b o u t a n a l ysi s e n d t i m e .
14
Automation of Routine Analysis Procedures
The entire series of operations involved in analysis can be automated, automatic pass/fail judgment function for system conformity testing,
from system startup, mobile phase purging, column equilibration in operations for routine analysis, such as injecting samples based on test
preparation for starting measurements, and starting the analysis to results and stopping the analysis, can also be automated.
shutting down the system after analysis. In combination with the
Auto start-up
Start up system Automatically starts up the system. Power consumption can be minimized by
activating the sleep mode until the user is ready to run the analysis.
Auto purge
Purge flow lines with mobile phase
Automatically purges mobile phases before analysis.
for analysis
Baseline check
Monitors baseline noise and drift values, automatically determines that the values
Column equilibration are within the pass/fail criteria specified for each UV/ VIS or PDA detector channel
(baseline stability), and then starts the analysis.
E
Pump delivery switches OFF Auto-shutdown function
Detector switches OFF reduces power consumption
The auto-shutdown function
minimizes power consumption while the system is
Sleep mode (Power-ON)
in the sleep mode after analyses. This allows you Power Consumption:
Column oven temperature control to reduce power consumption in sleep mode by Approx. 90 W
switches OFF 95% or more. Also, by executing operations
specified in instrument methods, such as rinsing 95% OFF
lines inside the instrument, before the
Auto-shutdown (Power-OFF)
auto-shutdown function puts the system in sleep
Power Consumption:
Shutdown mode, the function can help manage the Approx. 2.5 W
instrument status after analyses are finished.
LC Systems 15
intelligent
Seamlessly Transfers Existing Methods
to a Cutting-Edge System
LC-2010HT
Prominence-i
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 min
Other vendor's
system
Prominence-i
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 min
16
System-to-System Reproducibility Improves Data Compatibility
In addition to its reproducible performance on a single system, areas such as solvent delivery precision, concentration accuracy,
the i-Series' excellent system-to-system reproducibility further and injection volume accuracy, the i-Series is now a new
improves data reliability. With its unsurpassed performance in industry standard for global labs.
mAU
1 2 3 4
600
500
Instrument 1
400
300
Instrument 2
200
100
Instrument 3
00
0 1 2 3 4 5 6 7 8 9 10 11 min
Prominence-i Nexera-i
mAU mAU
20 150
Shim-pack VP-C8 Shim-pack VP-ODS
(150x4.6 mmI.D., 5 m) (250x4.6 mmI.D., 5 m)
15
100
10
50
5
0 0
0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 min 0.0 5.0 10.0 15.0 20.0 25.0 30.0 min
Approx. Approx.
20
mAU 1/4 150
mAU 1/5
Shim-pack XR-C8 Shim-
Shim-pack XR-ODSII
15 (75x3.0 mmI.D., 2.2 m) (150x3.0 mmI.D., 2.2 m)
100
10
50
5
0 0
0.0 1.0 2.0 3.0 4.0 5.0 min 0.0 1.0 2.0 3.0 4.0 5.0 6.0 min
LC Systems 17
i-Series Addresses a Wealth of Applications
Pharmaceuticals
The i-Series supports a wide range of HPLC analyses in the
pharmaceutical industry, from identification and purity
1. Impurity B 2. Impurity C
testing at the drug discovery stage to impurity testing and
3. Impurity D 4. Impurity E
quantitative determination at the manufacturing and 5. Duloxetine 6. Impurity F 5
3
1
4
6
0 10 20 30 min
18
Standard performance features, such as excellent baseline
stability, ultra-low carryover performance, and excellent
1. Impurity E 3
reproducibility of sample injection, ensure stable and 2. Impurity A
validated results in any analysis based on national 3. Pramipexole
4. Impurity B
Pharmacopeia of each country. 5. Impurity C
4
1 2 5
Analysis using a PDA detector has the advantage of confirming the UV/VIS spectrum for each peak in the chromatogram.
2
1. Salicylic Acid 2. Benzoic Acid
3 3. Sorbic Acid 4. Phenoxyethanol
1 5. Methylparaben 6. Dehydroacetic Acid
7. Ethylparaben 8. Glycyrrhetinic Acid
9. Isopropylparaben 10. Propylparaben
6 11. Isobutylparaben 12. Butylparaben
7
5 9
10
4 11 12
8
Therapeutic dentifrice
mAU mAU
mAU mAU
300 300
60 200
200 200
40
100
100 100 20
0 0 0 0
200 250 300 nm 200 250 300 nm 200 250 300 nm 200 250 300 nm
1. Salicylic Acid 7. Ethylparaben 8. Glycyrrhetinic Acid 10. Propylparaben
LC Systems 19
Foods and Beverages
The i-Series supports a wide range of HPLC analyses in the food
and beverage industry, such as active ingredient analysis and
toxic substance analysis.
2
3
Standard sample 4
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 min 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 min
High-temperature analysis of sugars Gradient analysis of oligosaccharides using ELSD in Japanese sake
20
Environmental
The i-Series supports a wide range of HPLC analyses in the
environmental industry, water, atmospheric and soil analysis.
Peaks Peaks
1. Naphthalene 2. Acenaphthylene 1. C10
1
3. Acenaphthene 4. Fluorene 2. C11
3 5. Phenanthrene 6. Anthracene
7. Fluoranthene 8. Pyrene 3. C12
2
9. Benzo[a]anthracene 10. Chrysene 4. C13
11. Benzo[b]fluoranthene 12. Benzo[k]fluoranthene 5. C14
13. Benzo[a]pyrene 14. Dibenzo[a,h]anthracene 3
15. Benzo[g,h,i]perylene 16. Indeno[1,2,3-cd]pyrene
4
1 5
12
2 4 15
9 13
10 11 14 230 nm (UV)
5 6 7 8 16
RF-20Axs
The drinking water spiked with 0.04 mg/L each component
0.0 5.0 10.0 15.0 20.0 25.0 30.0 min 0.0 5.0 10.0 15.0 20.0 min
Simultaneous analysis of polycyclic aromatic hydrocarbons High-sensitivity analysis of anionic surfactants (LAS) in drinking water
UV spectrum of
The i-Series supports a wide range of HPLC analyses in the polymer additive (peak2)
chemical industry, from small molecules to polymers.
200 300 nm
Peaks
1 1. Polystyrene
2. Irganox 1010
230nm (UV)
RID-20A
80
Mn=15422
Result of molecular 60
enables GPC analysis of hydrophobic polymers and other weight distribution
40
materials. In addition, LabSolutions GPC software 20
facilitates molecular weight distribution calculation. For 0
trace amounts of light-absorbing additives in samples, a 3.5 4.0 4.5 5.0 log (M.W.)
LC Systems 21
High-Performance Columns for Stable Routine Analyses
Shim-pack XR Series
Shim-pack XR series employs particle sizes of 2.2 m and 1.6 m to correspond
with both ultrafast and high-resolution analyses. The three series, differing
according to pressure tolerance, can be selected according to the analysis purpose
and the device to be used.
22
Shim-pack VP Series
Shim-pack MAqC-ODS I
Shim-pack MAqC-ODS I reversed-phase columns are packed This increases the retention of basic compounds. Therefore,
with a silica gel containing metal and added octadecylsilyl this allows use with only a buffer solution as the mobile
group. In addition to the hydrophobic characteristics of the phase for analyses that previously required using an ion pair
ODS, the metal content provides cation-exchange effects. reagent and enables using gradient elution.
Ghost Trap DS
Ghost Trap DS-HP
It has been designed to effectively adsorb impurities in the mobile phase in order
to reduce the time required for method development and impurity analysis. There
are two types. The Ghost Trap DS is a high cost-performance cartridge type that
can be used at 35 MPa. The Ghost Trap DS-HP is for UHPLC and can be used at 100
MPa.
LC Systems 23
Nexera-i / Prominence-i
Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its
affiliates, whether or not they are used with trademark symbol TM or .
Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu
disclaims any proprietary interest in trademarks and trade names other than its own.