Professional Documents
Culture Documents
F200, F400 Technical Specifications: Front View
F200, F400 Technical Specifications: Front View
FRONT VIEW
InServ F400
in a 3PAR 3PAR INSERV STORAGESERVERFAMILY SPECIFICATIONS F200 F400
2-Meter Cabinet
SUMMARY
3PA
R
2
P
4
P
0 1
1
CONTROLLER NODE AC
Fibre Channel and iSCSI host ports are mixable on same 3PAR InServ Storage Server
INP
100 UT I o
NODE 1
-24
0V
2 E0
PS P E1
0 !
- 4 C0
E0
E1
Each port is full bandwidth 1 Gbit/s iSCSI with complete iSCSI and TCP/IP offload
PS-0
C0 AC
INP
100
-24
UT
0V
I o
* Max raw capacity currently supported with any and all drive types.
FCAL-B
ID PS
1 1 !
-
!
FCAL-A
Controller Node Chassis (Base Configuration) Max. Watts per Cabinet (fully populated) 6,330
F200 Dimensions (width x height x depth) 19 x 6.85 x 22 in. 48.3 x 17.4 x 55.9 cm Max. BTUs/hour per Cabinet (fully populated) 21,599
F400 Dimensions (width x height x depth) 19 x 13.85 x 22 in. 48.3 x 35.17 x 55.9 cm Input Voltage (VAC) 220 (200-240)
F200 with 2 Controller Nodes (fully populated) 90 lbs 40.8 kg Frequency (Hz) 50-60
F400 with 2 Controller Nodes (fully populated) 121 lbs 54.9 kg Circuit Breaker Max. 30 amps per PDU (de-rated to 24 amps)
2 Controller Nodes (fully populated) 36 lbs 16.3 kg
Power Connectors for Cabinet (4) L6-30P with 1+1 rdnt.
Drive Chassis
Power Receptacle (4) L6-30R with 1+1 rdnt.
Dimensions (width x height x depth) 19 x 5.12 x 22 in. 48.3 x 13 x 55.9 cm
Drive Chassis (without Drives) 154 watts / 525 BTUs/h
Drive Chassis (fully populated) 78 lbs 35.4 kg
Transactional* (watts / BTUs/h) Idle (watts / BTUs/h)
Service Processor
4 x 50-GB SSD Drives ** 8 / 26 4 / 14
Dimensions (width x height x depth) 19 x 1.68 x 15 in. 48.3 x 4.3 x 38.1 cm
Service Processor 16.5 lbs 7.5 kg 4 x 146-GB FC Drives ** 57 / 194 41 / 140
Dimensions (width x height x depth) 23.8 x 76.4 x 36 in. 60.5 x 194.1 x 91.4 cm 4 x 450-GB FC Drives ** 88 / 300 57 / 194
Service Clearance 30 in. (76.2 cm), front and back 4 x 1-TB NL Drives ** 47 / 160 32 / 109
Maximum Weight (fully populated) 1,361.5 lbs. 617.6 kg Temperature (F/C), 0 3,000 ft. 50104F/1040C
Maximum Weight per Leveling Foot 340.4 lbs. 154.4 kg Temperature (F/C), 3,000 10,000 ft. 5095F/1035C
Maximum Load per Leveling Foot 111 lbs/sq. in. 50.5 kg/sq. cm Altitude (ft/m) max. 10,000 ft. / 3,048 m
FC Cable Core Diameter 50- or 62.5-micron EMI/EMC FCC Part 15 47 CFR Class A, ICES-003 Class A, CISPR 22,
EN55022, EN55024
Supported Host iSCSI Connections
Safety UL 60950-1:2003, CAN/CSA-C22.2 No. 60950-1-03,
iSCSI Cable Type CAT5, CAT5E, CAT6 copper (1Gb)
EN 60950-1:2001+A1, EN 60825-1:1994+A1+A2,
POWER ANDHEAT DISSIPATION CB Scheme with all country differences
Components Two Controller Nodes Drive Chassis Certifications/Markings cTUVus Mark, GS Mark (Controller Only), CE Mark, FCC
Watts 730 525 Class A, ICES-003 Class A, VCCI Class A, WEEE, China RoHS
BTUs/hour (fully populated) 2,491 BTUs/hr. 1,791 Energy Consumption Efficiency
Input Voltage (VAC) 100-240 100-240 (JapanGreen Law) 0.182
Frequency (Hz) 50-60 48-62 INFORMOPERATING SYSTEM INTERFACES
Power Receptable (2) IEC-320 with 1+1 rdnt. (2) IEC-320 with 1+1 rdnt. Host Platform Support for InForm Microsoft Windows XP, Windows 2003,
Management Console (GUI) Sun Solaris 9 & 10
All components can be mounted in a 3PAR 2-meter cabinet, or in an EIA Standard 19-inch rack.
Host Platform Support for InForm Command Microsoft Windows XP, Windows 2000,
* Under maximum load
** Up to 16 Drives of any combination of FC, NL, and up to 8 SSD Drives per Drive Chassis Line Interfaces Windows 2003, Sun Solaris 8 & 9, Redhat
Specifications are subject to change without notice. Enterprise Linux 5, SuSE Enterprise Linux 10
SSH is supported for CLI. InForm CIM API and SNMP also supported.
Includes power and heat dissipation specifications for the Service Processor as follows: 317 Watts, 1082 BTUs/hour, 100 240 VAC
Input Voltage, 50 60 Hz Frequency, and (1) IEC-320 Power Receptacle
3PAR Inc.
4209 Technology Drive Japan Green Law statement of compliance: The energy consumption efficiency value has been calculated per requirements
Fremont, CA 94538 for Category-G Magnetic Disk Drive Units by dividing the power consumption, measured according to the definition in the Law
Concerning the Rational Use of Energy, by the storage capacity defined in the Energy Conservation Law. The efficiency value is
510.413.5999
based on either a host-maximized or a storage-maximized F200 configuration using 300-GB drives.
www.3PAR.com
2009 3PAR Inc. All rights reserved. 3PAR, the 3PAR logo, Serving Information, InServ, InForm, InSpire, and Thin Built In are all trademarks
or registered trademarks of 3PAR Inc. All other trademarks and registered trademarks are the property of their respective owners. 3PAR-fis-ts-10.0