Overview: Menus and User Interface (UI)
My online CV
Download sites
For details on command-line usage, see section CSV Import and misc .
http://www.plcsimulator.org/documentation/overview 1/3
4/10/2017 Overview - Modbus PLC Simulator
Menus
The first menu is the Task/System menu. Right-click on the window title.
My Projects
DipSW Bitmask
The normal ways of controlling a window are available here, highlighted is the About box,
which gives program version and contact information
Always on top - ensures that the simulator window remains on top of other windows, select it
again to turn the mode off
Advanced Emulation - Takes you to the advanced emulation settings dialog relevant to the
protocol you are using.
Read only - Turns the simulator into read-only mode, registers cannot be set.
Solid Window,Alpha blend % - set the transparncy of the window, (not for windows versions
< Windows2000)
Port open/close - In Serial protocols this makes the sim release the serial port so other
programs can access it. The simulator is effectively disabled in this mode.
User Interface
........................
Hotkeys
<CTRL>-A = Save register values
http://www.plcsimulator.org/documentation/overview 2/3
4/10/2017 Overview - Modbus PLC Simulator
<CTRL>-B = About box
<CTRL>-C = Toggle display registers/comms debugger mode
<CTRL>-E = Erase, clears all register values
<CTRL>-J = inJect error, injects a char on the RS232 protocol used
<CTRL>-L = Load (opposite of save)
<CTRL>-M = Open emulation settings dialog for the current protocol
<CTRL>-N = Noise, opens noise settings dialog (RS232 protocols only)
<CTRL>-S = Settings, opens dialog for current protocols's settings
<CTRL>-T = Transparency, toggles to the next alpha-blend level 1=opaque, 2=semi
see-thru, 3=very see-thru, this is more a fancy feature that is useful in that the program
becomes transparent, so you can sometimes superimpose it over another program
F1 = Help, opens the local help file in your default web browser.
Serial protocols:Hook up a cable (just a 2,3 and 7 crossed ,4,5 looped, and 6,8,20
looped should be fine, hardware handshaking is not my strong side), but there is some
support there.
Ethernet:U must have an ethernet adapter or loopback adapter installed.
New option for starting with all devices offline added.
The "responsiveness" setting changes the delay in the program before it responds to a
valid request.
Note: If the station indicator button for a station is off, the simulator will not respond to data
requests for that station ID, even though the client is connected.