Professional Documents
Culture Documents
Izoelektro Catalogue
Izoelektro Catalogue
Katalog izdelkov
Product catalogue
Dejavnost Activity
Splošno General
Predmet našega poslovanja je razvoj, proizvodnja in prodaja The subject of our business is development, production and
opreme za izgradnjo elektroenergetskih sistemov do 52 kV. sale of power transport equipment intended for constructions of
Naši najpomembnejši proizvodi so: electro systems up to 52 kV. Our most important products are:
• odvodniki prenapetosti, • surge arresters,
• indikatorji stanja odvodnikov prenapetosti, • surge arresters’ condition indicators,
• natezni in podporni kompozitni izolatorji, • tension and post composite insulators,
• sistemi izgradnje daljnovodov, • overhead power lines construction systems,
• spojna in obesna oprema, • junction and suspension equipment,
• koncentrični material. • connecting sleeves.
Poleg prodaje lastnih izdelkov dobavljamo vso ostalo Within the supply of own products we supply all other
opremo, ki jo kupci pri nas zahtevajo. equipment that customers request from us.
Certifikati Certificates
Zavedamo se, da je za naše odjemalce najpomembnejša We are aware that the quality of products is most important
kakovost proizvodov. Od leta 2000 imamo v podjetju for our customers. Since 2000 we have established and
vzpostavljen in ustrezno vzdrževan sistem vodenja, ki suitably maintained a system of guidance which fulfils
izpolnjuje zahteve standarda ISO 9001. Leta 2007 pridobljen the demands of standard ISO 9001. Certificate ISO 14001
certifikat ISO 14001 pa potrjuje odgovorno načrtovanje novih gained year 2007 confirms responsible development of new
proizvodov in ekološko ravnanje z okoljem. products and eco-environmental management.
Inovativnost Innovativeness
V naših proizvodih je vgrajenih sedem lastnih patentov, ki In our products are embedded seven patents which were
smo jih razvili v lastnem razvojno-raziskovalnem inštitutu. Prvi developed in our own Research and Development Institute.
v svetu smo razvili, patentirali in leta 2004 pričeli s prodajo First in the world we have developed, patented and in 2004
kompozitnih podpornih izolatorjev z izolacijsko glavo in began to sale post composite insulators with insulated
inovativnim načinom pritrditve vodnika. V letu 2017 smo top fitting and innovative method for attachment of wire
razvili novo vzmetno sponko. conductor. In 2017 we developed a new spring clamp.
Novost Innovation
SN odvodnik razreda DH - tip SNO je preizkušen v skladu z Class DH surge arrester - SNO type is tested according to
najnovejšo izdajo standarda IEC 60099-4:2014. the latest edition of the IEC 60099-4:2014 standard.
PKI - E nova različica zgornjega PA priključka z vzmetno PKI E - new version of PA upper fitting with spring clamp for
sponko za vodnike premera Φ15 do Φ30. conductor with cross sections Φ15 to Φ30.
PKIL IZO - nov tip izolatorja za ločilnike v petih višinskih PKIL IZO - new type of insulator for switchers in five height
izvedbah za različne napetostne sisteme. versions for different voltage systems.
Cilji Goals
Naš cilj je razviti in prijaviti vsaj dva patenta letno in postati Our goal is to develop and apply at least two patents
v svetu prepoznaven proizvajalec izdelkov z vgrajenimi per year and to become a world recognized producer of
lastnimi patenti. products with its own patents installed.
Vizija Vision
Nadaljnji razvoj je usmerjen v proizvodnjo srednjenapetostnih Further development is focused on the production of
odvodnikov prenapetosti s silikonskim plaščem, kompozitnih medium voltage surge arresters with silicone coat and
podpornih izolatorjev z uporabo priključkov iz izolacijskega with an indication of leakage current, post line composite
materiala in kompozitnih izolatorjev s kapacitivnim insulators with end fittings made of insulating material and
kazalnikom. composite insulators with a capacitive pointer.
www.izoelektro.com 1
Kazalo Index
2
Kazalo Index
www.izoelektro.com 3
Kazalo Index
4.23 PKI izolatorji - primer naročila 72 4.23 PKI insulators - order example 72
4.24 PA jahači 74 4.24 PA covers 74
4.25 PA kapa SZM/0 74 4.25 PA cap SZM/0 74
4.26 PA kapa SZM/3 74 4.26 PA cap SZM/3 74
4.27 PA sornik 75 4.27 PA bolt 75
4.28 PA telo sponke z vzmetjo 75 4.28 PA body of spring clamp 75
4.29 PA sponka vijačna 75 4.29 PA screw clamp 75
4.30 PA vezica 76 4.30 PA cable tie 76
4.31 PA vijak 76 4.31 PA screw 76
4.32 SN silikonski plašč SILP 76 4.32 MV silicone coat SILP 76
4.33 SN vzmet 77 4.33 MV spring 77
4.34 OPKI oporniki 77 4.34 OPKI pins 77
4.35 OPKIL opornik za ločilnik 77 4.35 OPKIL pin for switcher 77
5. DV pribor 5. PL accesories
5.1 SZ-U sponka zatezna univerzalna 80 5.1 SZ-U universal tension clamp 80
5.2 SN-U sponka nosilna univerzalna 80 5.2 SN-U universal suspension clamp 80
5.3 VS 20 sponka vzmetna 80 5.3 VS 20 spring clamp 80
5.4 VS 25 sponka vzmetna 81 5.4 VS 25 spring clamp 81
5.5 VS SER b-20 sponka vzmetna z izolatorjem 81 5.5 VS SER b-20 spring clamp with insulator 81
5.6 VS SER b-25 sponka vzmetna z izolatorjem 81 5.6 VS SER b-25 spring clamp with insulator 81
5.7 VS R 125 N sponka vzmetna z izolatorjem 82 5.7 VS R 125 N spring clamp with insulator 82
5.8 VS R 125 L sponka vzmetna z izolatorjem 82 5.8 VS R 125 L spring clamp with insulator 82
5.9 DSI S distančnik izolacijski z vzmetno sponko 83 5.9 DSI S insulating spacer with spring clamp 83
5.10 DSI M distančnik izolacijski z vijačno sponko 83 5.10 DSI M insulating spacer with screw clamp 83
5.11 Distančnik jeklen 84 5.11 Steel yoke 84
5.12 Distančnik jeklen dvojni 84 5.12 Steel yoke double 84
5.13 Podaljšek jeklen 84 5.13 Steel extension link 84
5.14 Podaljšek jeklen 90° 85 5.14 Steel extension link 90° 85
5.15 S - kavelj 85 5.15 S - hook 85
5.16 S - kavelj 90° 85 5.16 S - hook 90° 85
5.17 Rogljič NKI 86 5.17 Arcing horn NKI 86
5.18 G streme OS 65 86 5.18 G shackle OS 65 86
5.19 G streme OS 80 86 5.19 G shackle OS 80 86
5.20 Vijak ozemljitveni 87 5.20 Earthing screw 87
6.1 R sponka ravna z dvojnim konusom 90 6.1 R double conoid flat clamp 90
6.2 T sponka odcepna z dvojnim konusom 90 6.2 T double conoid branch clamp 90
6.3 Td sponka odcepna s konusom 90 6.3 Td conoid branch clamp 90
6.4 Rp priključek ravni 91 6.4 Rp flat fitting 91
6.5 P priključek ploščat 91 6.5 P plane fitting 91
6.6 V konus 91 6.6 V cone 91
7. VN Laboratorij 7. HV Laboratory
4
Seznam ikon List of icons
HYDROPHOBIC
UV RESISTANCE
SELF-CLEANING
Samočistilnost Self-cleaning
IP zaščita IP 67 IP protection
100 %
100% kontrola SUCCESFULLY 100% control
TESTED
www.izoelektro.com 5
Seznam kratic List of abbreviations
μs – mikrosekunda μs – microsecond
°C – stopinj celzija °C – degrees celsius
AD – preskočna razdalja AD – arcing distance
AgL – tip varovalke AgL – type fuse
Al – aluminij Al – aluminium
CD – plazilna pot CD – creepage distance
d – premer d – diameter
Dmin – minimalna razdalja Dmin – minimum distance
DOPPS – Društvo za opazovanje in preučevanje ptic DOPPS – Association for the observation and study of birds
DV – daljnovod PV – power line
E – električna poljska jakost E – electric field strength
Fh – horizontalna sila Fh – horizontal load
Fv – vertikalna sila Fv – vertical load
H – višina H – height
IEC – Mednarodna komisija za elektrotehniko IEC – International Electrotechnical Commimisson
Iimp – impulzni odvodni tok Iimp – discharge current
Imax – maksimalni odvodni tok Imax – maximal discharge current
In – nazivni odvodni tok In – nominal discharge current
IP – stopnja zaščite IP – Ingress protection level
kg – kilogram kg – kilogram
kJ – kilo joule kJ – kilo joule
kV – kilo volt kV – kilo volt
l – dolžina l – length
L – faza L – line
m – meter m – meter
mA – miliamper mA – milliampere
mm – milimeter mm – millimetre
mm2 – kvadratni milimeter mm2 – square millimetre
Mt – torzijski moment Mt – Torque
Mu – upogibni moment Mu – Cantilever strength
N – newton N – newton
Nm – newton meter Nm – newton metre
NN – nizka napetost LV – low voltage
ns – nanosekunda ns – nanosecond
PA – poliamid PA – polyamide
PIV – polizoliran vodnik CC – covered conductor
s – sekunda s – second
SCL – nazivna upogibna sila SCL – specified cantilever load
SN – srednja napetost MV – medium voltage
ST – jeklo ST – steel
t – čas t – time
T – temperatura T – temperature
tA – odzivni čas tA – response time
Uc – trajna obratovalna napetost Uc – continuous operating voltage
UL 94 – standard gorljivosti UL 94 – flammability standard
Umax – maksimalna napetost Umax – maximum voltage
Up – napetostni zaščitni nivo Up – voltage protection level
Ur – nazivna napetost Ur – nominal voltage
Ures – preostala napetost Ures – residual voltage
UV – ultravijolična zaščita UV – ultra-violet protection
v – hitrost širjenja udarnega vala v – speed of shock wave
V-0 – stopnja gorljivosti V-0 – burning rate
W – energijska absorpcija W – energy absorption
6
1
NN odvodniki LV surge
prenapetosti arresters
1 NN odvodniki prenapetosti LV surge arresters
Lastnosti Characteristics
Odklopna naprava reagira: The disconnecting device reacts:
• po določenem številu udarov, ko v normalnem • after a certain number of strokes when in normal
obratovanju tok skozi odvodnik naraste nad 1 mA, operation the current through the surge arrester
• v primeru atmosferske praznitve (tok večji od 65 kA). increases over 1 mA,
Po delovanju odklopne naprave je potrebno zamenjati • in case of atmospheric discharge (current bigger than 65 kA).
odvodnik prenapetosti. Odklopna naprava je vidno ločena After the disconnecting device has been actived it is necessary
vendar povezana z odvodnikom prenapetosti. to replace the surge arrester. The disconnecting device is
visibly separated but still attached to the surge arrester.
Installation
Vgradnja The position for installing NNO and MOSIPO surge arresters
Mesto montaže odvodnikov prenapetosti NNO in MOSIPO, is decided by directives and technical regulations.
določajo pravilniki in tehnični predpisi. They must be installed:
Obvezno se vgradijo na: • on all branches and ends of low voltage overhead
• vse odcepe in zaključke nizkonapetostnih prostih vodov, power lines,
• medsebojni razdalji maksimalno do 1000 m, • at a maximum mutual distance up to 1000 m,
• razdalji manjši od 500 m, kjer so nevihte pogostejše, • at a distance smaller than 500 m, where storms
• vseh prehodih prostih vodov na kable in obratno. occur more often,
• in all passages from free conductors to cables and
vice versa.
Splošni podatki General data
• Odzivni čas: tA < 25 ns • Response time: tA < 25 ns
• Temperaturno območje okolja: T = -60 °C … +85 ºC • Ambient temperature range: T = -60 °C … +85 ºC
• Stopnja zaščite: IP 67 • Ingress protection level: IP 67
• Plašč: silikon LSR • Coat: silicone LSR
• Barva silikona: siva • Silicone colour: grey
• Napetostni nivoji: 275, 280, 440, 500, 690 V • Voltage levels: 275, 280, 440, 500, 690 V
• Testirani po standardu: IEC 61643-1 in IEC 61643-11 • Tested according to standard: IEC 61643-1 and IEC 61643-11
• IEC razred: II • IEC class: II
• Ozemljitveni vodnik: H07V-K • Earthning connductor: H07V-K
HYDROPHOBIC UV RESISTANCE SELF-CLEANING
100 %
IP 67 SUCCESFULLY
TESTED
SLOVENIA
8
NN odvodniki prenapetosti LV surge arresters 1
1.2 NNO, In = 10 kA 1.2 NNO, In = 10 kA
2
Ozemljitveni vodnik: H07V-K 6 mm Earthing conductor: H07V-K 6 mm2
M8
Varovalo
Safety tie
Naziv NNO NNO Name
Ø38
10/280 10/440
Koda (l = 0,5 m) 20 60 50 20 60 60 Code (l = 0,5 m)
Koda (l = 1,0 m) 20 60 51 20 60 61 Code (l = 1,0 m)
Uc (AC/DC) 280/350 V 440/585 V Uc (AC/DC)
Up < 1,10 kV < 1,80 kV Up
l ± 10%
W 2450 J 3504 J W
Masa (l = 0,5 m) 0,0608 kg 0,0971 kg Mass (l = 0,5 m)
Ozemljitveni vodnik Masa (l = 1,0 m) 0,0967 kg 0,1037 kg Mass (l = 1,0 m)
Earthing conductor
7
16
M8
!
NOVO
!
Varovalo NEW
Safety tie
Naziv NNO NNO Name
10/280 10/440
Ø38 Uc (AC/DC) 280/350 V 440/585 V Uc (AC/DC)
Up < 1,10 kV < 1,80 kV Up
W 2450 J 3504 J W
Masa 0,0408 kg 0,0571 kg Mass
98 ± 10%
Povezovalni vodnik
Connecting conductor
Kabelski čevelj
Cable lug
www.izoelektro.com 9
1 NN odvodniki prenapetosti LV surge arresters
Varovalo
Safety tie
Varovalo
Safety tie
10
NN odvodniki prenapetosti LV surge arresters 1
1.6 MOSIPO, In = 10 kA brez 1.6 MOSIPO, In = 10 kA without
ozemljitvenega vodnika, kabelski čevelj earthing conductor, cable lug
Povezovalni vodnik: H07V-K 6 mm2 Connecting conductor: H07V-K 6 mm2
Kabelski čevelj: Cu 6/8 mm Cable lug: Cu 6/8 mm
M8
!
NOVO
!
Varovalo NEW
Safety tie Naziv MOSIPO MOSIPO Name
10/275 10/440
Uc (AC/DC) 275/350 V 440/585 V Uc (AC/DC)
Up < 1,00 kV < 1,80 kV Up
W 2450 J 3200 J W
Ø47
Masa 0,0800 kg 0,0900 kg Mass
93 ± 10%
Povezovalni vodnik
Connecting conductor
Kabelski čevelj
Cable lug
90
450 ± 10%
Up 40 kA 40 kA 40 kA Up
Ozemljitveni vodnik
Earthing conductor
W < 1,86 kV < 2,0 kV < 2,24 kV W
Masa 2450 J 3200 J 3504 J Mass
250 ± 10%
Kabelski čevelj
Cable lug
www.izoelektro.com 11
1 NN odvodniki prenapetosti LV surge arresters
1.8 NNO in MOSIPO - primer naročila 1.8 NNO and MOSIPO - order example
Priključek P1
Connector P1
NNO 10/440
Varovalo
Safety tie
l ± 10%
12
NN odvodniki prenapetosti LV surge arresters 1
1.9 Priključek P1 1.9 Connector P1
Namen: priključek za goli vodnik ø4-12 Purpose: connector for bare conductor ø4-12
Koda: 20 66 01 Code: 20 66 01
42
ø8-12 ø4-8
M5
M8 30
M8
l ± 10%
79
ø9
58
M8
www.izoelektro.com 13
1 NN odvodniki prenapetosti LV surge arresters
74
Al 16-95 mm²
79
M8
M8 150
ø13
260
23
ø4-16
29
M8
14
NN odvodniki prenapetosti LV surge arresters 1
1.15 TY1 in TY1-F splošno 1.15 TY1 and TY1-F generally
Proizvod Product
TY1 so kovinsko oksidni odvodniki prenapetosti v TY1 are metal oxide surge arresters in modular housing.
modularnem ohišju. TY1-F so kompaktni kovinsko oksidni TY1-F are compact metal oxide surge arresters with
odvodniki prenapetosti z varovalko. Namenjeni so za integrated backup fuse. They are designed to be
vgradnjo v glavno razdelilno omarico kot prva stopnja installed into the main junction box as the first level of
zaščite pred direktnim udarom strele. protection against direct lightning strikes.
Lastnosti Characteristics
Odklopna naprava reagira: The disconnecting device reacts:
• ko v normalnem obratovanju tok skozi odvodnik • when in a normal operation the current through the
naraste nad 1 mA, surge arrester increases over 1 mA,
• v primeru atmosferske praznitve • In case of an atmospheric discharge (current higher
(tok večji od 100 kA). than 100 kA).
Po delovanju odklopne naprave se vidno polje obarva After the disconnecting device has been active the visual
rdeče. V tem primeru je potrebno pri TY1 zamenjati modul, field shows red colour. In this case it is necessary to replace
pri TY1-F pa celoten odvodnik prenapetosti. the TY1 module or in case of TY1-F a complete surge arrester.
Installation
Vgradnja The position for installing TY1 and TY1-F surge arresters is
Mesto montaže TY1 in TY1-F odvodnikov prenapetosti determined by directives and technical regulations. They must
določajo pravilniki in tehnični predpisi. be installed into junction boxes.
Obvezno se vgradijo v razdelilne omare.
General data
Splošni podatki • Response time: tA < 25 ns
• Odzivni čas: tA < 25 ns • Main Backup fuse: 100 AgL
• Glavna predvarovalka pri TY1: 100 AgL • Ambient temperature range: T = -20 °C … +80 °C
• Temperaturno območje okolja: T = -20 °C.. +80 °C • Ingress protection level: IP 20
• Stopnja zaščite: IP 20 • Housing material: thermoplastic V-0 (UL 94)
• Material ohišja: termoplast V-0 (UL 94) • Possibility of remote control
• Možnost daljinskega upravljanja • Mounting on top hat rail 35 mm2
• Montaža na klobučno letev 35 mm2 • Cross-section of connection conductor:
• Presek priključnega vodnika: - single-strand 35 mm2
- enožilni 35 mm2 - multi-strand 25 mm2
- večžilni 25 mm2 • Tested according to standard: IEC 61643-11
• Testirani po standardu: IEC 61643-11 • IEC class: l, ll
• IEC razred: l, ll
TY1 in TY1-F odvodniki prenapetosti za notranjo TY1 and TY1-F surge arresters for indoor installation
montažo imajo: have:
• certifikat akreditiranega laboratorija, • a certificate by an accredited laboratory,
• visok odvodni tok, • high discharge current,
• visoko stopnjo zaščite, • high level of protection,
• ugodno ceno, • favourable price,
• zanesljivo delovanje. • reliable performance.
www.izoelektro.com 15
1 NN odvodniki prenapetosti LV surge arresters
62,5
Naziv kompleta Modul TY1 Uc In Iimp Imax Up
50,5 18 Name of set Module TY1 (V) (kA) (kA) (kA) (kV)
TY1-1-275-40 M1-275-40 275 20 8 40 < 1,2
TY1-1-320-40 M1-320-40 320 20 8 40 < 1,5
L
TY1-1-385-40 M1-385-40 385 20 8 40 < 1,8
izoelektro.com
TY1-40
TY1-1-440-40 M1-440-40 440 20 8 40 < 1,8
T1 T2
TY1-1-275-60 M1-275-60 275 30 12,5 60 < 1,5
Modul TY1
35
90
62,5
Naziv kompleta Modul TY1 Uc In Iimp Imax Up
50,5 36 Name of set Module TY1 (V) (kA) (kA) (kA) (kV)
TY1-2-275-40 M2-275-40 275 20 8 40 < 1,2
TY1-2-320-40 M2-320-40 320 20 8 40 < 1,5
L L
TY1-2-385-40 M2-385-40 385 20 8 40 < 1,8
izoelektro.com
TY1-40
izoelektro.com
TY1-40
TY1-2-440-40 M2-440-40 440 20 8 40 < 1,8
T1 T2 T1 T2
TY1-2-275-60 M2-275-60 275 30 12,5 60 < 1,5
Modul TY1
35
90
45
Module TY1 Uc =275VAC/ 350VDC Uc =275VAC/ 350VDC TY1-2-320-60 M2-320-60 320 30 12,5 60 < 1,8
Up =1,2kV Up =1,2kV
In =20kA
Imax =40kA
In =20kA
Imax =40kA TY1-2-385-60 M2-385-60 385 30 12,5 60 < 2,0
Iimp =8kA Iimp =8kA
F =50/60Hz F =50/60Hz
TY1-2-440-60 M2-440-60 440 30 12,5 60 < 2,0
TY1-2-275-80 M2-275-80 275 40 20 80 < 2,0
www.izoelektro.com TY1-2-320-80 M2-320-80 320 40 20 80 < 2,2
TY1-2-385-80 M2-385-80 385 40 20 80 < 2,4
TY1-2-440-80 M2-440-80 440 40 20 80 < 2,5
TY1-2-275-100 M2-275-100 275 50 25 100 < 2,4
TY1-2-320-100 M2-320-100 320 50 25 100 < 2,8
TY1-2-385-100 M2-385-100 385 50 25 100 < 3,0
TY1-2-440-100 M2-440-100 440 50 25 100 < 3,2
TY1-2-320-140 M2-320-140 320 80 25 140 < 3,0
TY1-2-385-140 M2-385-140 385 80 25 140 < 3,3
TY1-2-440-140 M2-440-140 440 80 25 140 < 3,5
16
NN odvodniki prenapetosti LV surge arresters 1
1.18 TY1 tripolni 1.18 TY1 triple pole
62,5
Naziv kompleta Modul TY1 Uc In Iimp Imax Up
50,5 54 Name of set Module TY1 (V) (kA) (kA) (kA) (kV)
TY1-3-275-40 M3-275-40 275 20 8 40 < 1,2
TY1-3-320-40 M3-320-40 320 20 8 40 < 1,5
L L L
TY1-3-385-40 M3-385-40 385 20 8 40 < 1,8
izoelektro.com
TY1-40
izoelektro.com
TY1-40
izoelektro.com
TY1-40
TY1-3-440-40 M3-440-40 440 20 8 40 < 1,8
T1 T2 T1 T2 T1 T2
TY1-3-275-60 M3-275-60 275 30 12,5 60 < 1,5
Modul TY1
35
90
45
Module TY1 Uc =275VAC/ 350VDC Uc =275VAC/ 350VDC Uc =275VAC/ 350VDC TY1-3-320-60 M3-320-60 320 30 12,5 60 < 1,8
Up =1,2kV Up =1,2kV Up =1,2kV
In =20kA
Imax =40kA
In =20kA
Imax =40kA
In =20kA
Imax =40kA TY1-3-385-60 M3-385-60 385 30 12,5 60 < 2,0
Iimp =8kA Iimp =8kA Iimp =8kA
F =50/60Hz F =50/60Hz F =50/60Hz
TY1-3-440-60 M3-440-60 440 30 12,5 60 < 2,0
TY1-3-275-80 M3-275-80 275 40 20 80 < 2,0
www.izoelektro.com TY1-3-320-80 M3-320-80 320 40 20 80 < 2,2
TY1-3-385-80 M3-385-80 385 40 20 80 < 2,4
TY1-3-440-80 M3-440-80 440 40 20 80 < 2,5
TY1-3-275-100 M3-275-100 275 50 25 100 < 2,4
TY1-3-320-100 M3-320-100 320 50 25 100 < 2,8
TY1-3-385-100 M3-385-100 385 50 25 100 < 3,0
TY1-3-440-100 M3-440-100 440 50 25 100 < 3,2
TY1-3-320-140 M3-320-140 320 80 25 140 < 3,0
TY1-3-385-140 M3-385-140 385 80 25 140 < 3,3
TY1-3-440-140 M3-440-140 440 80 25 140 < 3,5
45
Module TY1 Uc =275VAC/ 350VDC Uc =275VAC/ 350VDC Uc =275VAC/ 350VDC Uc =275VAC/ 350VDC
TY1-4-320-60 M4-320-60 320 30 12,5 60 < 1,8
Up =1,2kV Up =1,2kV Up =1,2kV Up =1,2kV
In =20kA
Imax =40kA
In =20kA
Imax =40kA
In =20kA
Imax =40kA
In =20kA
Imax =40kA
TY1-4-385-60 M4-385-60 385 30 12,5 60 < 2,0
Iimp =8kA Iimp =8kA Iimp =8kA Iimp =8kA
F =50/60Hz F =50/60Hz F =50/60Hz F =50/60Hz
TY1-4-440-60 M4-440-60 440 30 12,5 60 < 2,0
TY1-4-275-80 M4-275-80 275 40 20 80 < 2,0
www.izoelektro.com TY1-4-320-80 M4-320-80 320 40 20 80 < 2,2
TY1-4-385-80 M4-385-80 385 40 20 80 < 2,4
TY1-4-440-80 M4-440-80 440 40 20 80 < 2,5
TY1-4-275-100 M4-275-100 275 50 25 100 < 2,4
TY1-4-320-100 M4-320-100 320 50 25 100 < 2,8
TY1-4-385-100 M4-385-100 385 50 25 100 < 3,0
TY1-4-440-100 M4-440-100 440 50 25 100 < 3,2
TY1-4-320-140 M4-320-140 320 80 25 140 < 3,0
TY1-4-385-140 M4-385-140 385 80 25 140 < 3,3
TY1-4-440-140 M4-440-140 440 80 25 140 < 3,5
www.izoelektro.com 17
1 NN odvodniki prenapetosti LV surge arresters
68 18
Naziv kompleta Uc In Iimp Imax Up
Name of set (V) (kA) (kA) (kA) (kV)
TY1-F-1-275-40 275 20 8 40 < 1,2
L TY1-F-1-320-40 320 20 8 40 < 1,5
izoelektro.com TY1-F-1-385-40 385 20 8 40 < 1,8
TY1-40-F
TY1-F-1-440-40 440 20 8 40 < 1,8
T1 T2
TY1-F-1-275-60 275 30 12,5 60 < 1,5
90
37
Uc =440VAC/ 585VDC
Up =1,8kV
In =20kA
Imax =40kA
TY1-F-1-320-60 320 30 12,5 60 < 1,8
Iimp =8kA
F =50/60Hz
TY1-F-1-385-60 385 30 12,5 60 < 2,0
TY1-F-1-440-60 440 30 12,5 60 < 2,2
TY1-F-1-275-80 275 40 20 80 < 2,0
www.izoelektro.com
TY1-F-1-320-80 320 40 20 80 < 2,2
TY1-F-1-385-80 385 40 20 80 < 2,4
TY1-F-1-440-80 440 40 20 80 < 2,5
TY1-F-1-320-100 320 50 25 100 < 2,8
TY1-F-1-385-100 385 50 25 100 < 3,0
TY1-F-1-440-100 440 50 25 100 < 3,2
TY1-F-1-320-140 320 80 25 140 < 3,0
TY1-F-1-385-140 385 80 25 140 < 3,3
TY1-F-1-440-140 440 80 25 140 < 3,5
18
NN odvodniki prenapetosti LV surge arresters 1
1.22 TY1 in TY1-F - primer naročila 1.22 TY1 and TY1-F - order example
L L L
izoelektro.com izoelektro.com izoelektro.com
TY1-40 TY1-40 TY1-40
T1 T2 T1 T2 T1 T2
Modul TY1
Module TY1 Uc =275VAC/ 350VDC
Up =1,2kV
Uc =275VAC/ 350VDC
Up =1,2kV
Uc =275VAC/ 350VDC
Up =1,2kV
In =20kA In =20kA In =20kA
Imax =40kA Imax =40kA Imax =40kA
Iimp =8kA Iimp =8kA Iimp =8kA
F =50/60Hz F =50/60Hz F =50/60Hz
www.izoelektro.com
Naziv/Name: TY1-3-275-40
www.izoelektro.com 19
1 NN odvodniki prenapetosti LV surge arresters
Beležke Notes
20
2
11 12 1
10 2
9 3
8 4
7 6 5
SN odvodniki MV surge
prenapetosti arresters
2 SN odvodniki prenapetosti MV surge arresters
Lastnosti Characteristics
Vrhunsko kvaliteto jim zagotavlja: Their top quality is ensured by:
• zmogljiv varistorski blok, • top quality varistor block,
• toga konstrukcija, • rigid construction,
• plašč odporen na UV sevanje in kemične vplive, • resistance to UV radiation and chemical influences,
• vgrajen material, obstojen na vremenske vplive in staranje, • built-in material is resistant to weathering and ageing,
• varistorski blok, neposredno zaliti s silikonom. • varistors are directly enclosed by silicone.
Vgradnja Installation
Mesto montaže odvodnikov prenapetosti SNO in 2SS15N, The position for installing SNO and 2SS15N surge arresters
določajo pravilniki in tehnični predpisi. is decided by directives and technical regulations.
Odvodnike SNO in 2SS15N prenapetosti vgrajujemo: Surge arresters SNO and 2SS15N are used for:
• zunaj in znotraj, • indoor and outdoor installation,
• pri zaščiti elektroenergetskih naprav, • protection of electric devices,
• za zaščito kompenzacijskih naprav, • protection of compensation devices,
• na železnicah. • the railways.
Na zahtevo kupca izdelamo in dobavimo odvodnike At the customer’s request we produce and deliver surge
prenapetosti SNO in 2SS15N: arresters SNO and 2SS15N:
• kot tovarniški komplet po izbiri kupca, • as a factory set by buyer's choice,
• z željeno plazilno razdaljo, • with desired creepage distance,
• s trajno obratovalno napetostjo Uc do 1 do 44 kV. • with continuous operating voltage Uc from 1 to 44kV.
22
SN odvodniki prenapetosti MV surge arresters 2
2.2 SNO in 2SS15N 2.2 SNO and 2SS15N
izračun in parametri calculation and parameters
2. Podatki odvodnikov tipov SNO in 2SS15N 2. Data for surge arresters types SNO and 2SS15N
• k0 = 0,8 • k0 = 0,8
• k t = faktor trajne obratovalne napetosti za časno • k t = factor of permanent operating voltage for
prenapetost. temporary over voltage duration time.
kt=f(t)
1,5
Karakteristike Characteristics
1,45
1,4
Legenda: 1,35 Legend:
Krivulja T1: 1,3 Curve T1:
kt
1,15
Krivulja T2: Curve T2:
1,1
100 kA, 4/10 μs T2 T1 100 k A , 4/10 μs
1,05
predhodna energija prior energy
1
0,1 1 10 100 1000 10000 100000
t(s)
3. Izračun 3. Calculation
• Trajna obratovalna napetost sistema: • Continuous operating voltage of system:
[kV] [kV]
• Predhodna obratovalna napetost odvodnika: • Preliminary operating voltage of surge arrester:
[kV] [kV]
• Najvišja pričakovana časna prenapetost odvodnika: •
Highest expected transient over voltage of surge arrester:
[kV] [kV]
• Trajna obratovalna napetost odvodnika: • Continuous operating voltage of surge arrester:
[kV] [kV]
Ustrezen odvodnik prenapetosti izberemo iz tabel s We choose a suitable surge arrester from tables with data
podatki, na podlagi višje izračunane vrednosti med UC1 based on higher calculated value between UC1 and UC2
in UC2 tako, da izberemo prvo višjo trajno obratovalno so, that we choose the first higher value of permanent
napetost UC, ki je podana v tabeli. operating voltage UC specified in the table.
www.izoelektro.com 23
2 SN odvodniki prenapetosti MV surge arresters
Za izračun so potrebni najmanj naslednji podatki: At least next data is necessary for the calculation:
• lz – zaščitna razdalja odvodnika • lz – shielding distance of the surge arrester
• Uz – zdržna udarna napetost izolacije opreme. • Uz – allowed trigger voltage of insulating equipment.
• Ures – maksimalna vrednost preostale napetosti za • Ures – m aximum value of redidual voltage for the
določen tip odvodnika chosen type of surge arresters
• v – hitrost širjenja udarnega vala po električnih • v – speed of shock wave spreading through electric
vodih power lines
v = 300 m/μs – nadzemni vod v = 300 m/μs – overhead line
v = 150 m/μs – kabel v = 150 m/μs – cable
• S – pričakovana strmina prenapetostnega udara • S – anticipated steepness of over voltage lightning
strele stroke
S = 1550 kV/μs – leseni drogovi S = 1550 kV/μs – wooden poles
S = 800 kV/μs – ozemljene konzole S = 800 kV/μs – earthed brackets
2. Izračun 2. Calculation
Poenostavljena formula za izračun zaščitne razdalje: Simplified formula for calculating the shielding distance:
Po pravilu naj bo odvodnik prenapetosti priključen čim By the rules the surge arrester should be mounted as near
bliže ščiteni napravi. as possible to the device it protects.
24
SN odvodniki prenapetosti MV surge arresters 2
rimerjava med razredom 1 in
P he Comparison between class 1
T
razredom DH and class DH
Grafično je podana testna primerjava absorpcij energij A graphic comparison of energy absorption of surge
prenapetostnih odvodnikov za razred 1 in razred DH. Pri arresters for both Class 1 and Class DH can be found
uspešnem testiranju odvodnikov prenapetosti razreda 1 below. The arrester of Class 1 had to absorb a total of 18
mora odvodnik prenesti skupno 18 kJ/kV energije, po novem kJ/kV to pass the test where as the new standard arrester
standardu pa 40 kJ/kV. Kovinsko oksidni varistorji v razredu must absorb 40 kJ / kV. The Class DH metal oxide varistors
DH so pri testu veliko bolj obremenjeni in morajo absorbirati must absorb and dissipate twice as much energy as the
in odvesti enkrat več energije, kot je pri odvodnikih Class 1 surge arresters during the long wave test.
prenapetosti razreda 1 s preizkusom dolgega vala.
45
40
SNO
Legenda: 35 Legend:
W: energija [kJ/kV]
30
40 W: energy [kJ/kV]
kJ/kV
W [kJ/kV]
25
20
Razred 1 2SS15N Class 1 2SS15N
Razred DH SNO 15 2SS15N Class DH SNO
10
18
5 kJ/kV
0
www.izoelektro.com 25
2 SN odvodniki prenapetosti MV surge arresters
!
SNO
Uc= kV Ur= kV In=10kA NOVO!
NEW
Class DH Isc=20kA
www.izoelektro.com
32
H±5
11 12 1
10 2
9 3
8 4
7 6 5
M12x20
54
Ø140
Koda Uc Ur Ures CD AD A B H
Code (kV) (kV) (kV) (mm) (mm) (mm) (mm) (mm)
10 40 00 3,20 4,00 13 80 100
10 60 00 6,40 8,00 22 343 154 100 120 136
10 80 00 7,60 9,50 31 120 140
11 00 00 10,8 13,50 35 140 160
453 186 168
11 20 00 12,0 15,00 39 160 180
11 40 00 14,0 17,50 47 563 218 180 200 200
11 60 00 16,0 20,00 60 674 250 200 220 232
12 00 00 20,4 25,50 64 784 282 240 260 263
12 20 00 22,0 27,50 72 674 250 270 300 232
12 40 00 24,0 30,00 76 784 282 300 320 263
12 60 00 26,0 32,50 85 894 314 320 340 295
12 80 00 28,0 35,00 88 340 360
1004 345 327
13 40 00 34,0 42,50 110 400 420
13 60 00 36,0 45,00 114 1114 377 420 440 359
13 80 00 38,0 47,50 124 440 460
14 00 00 40,4 50,50 130 1234 409 450 470 391
14 40 00 44,0 55,00 143 470 490
Ures - preostala napetost pri 10kA (8/20 µs) Ures - residual voltage at 10kA (8/20 µs)
CD - plazilna pot CD - creepage distance
AD - preskočna razdalja AD - arcing distance
A - minimalna razdalja do stene A - minimum distance to wall
B - minimalna razdalja med fazami B - minimum distance between phases
Opomba: možne so še izvedbe z Uc (kV) Note: other possible versions with Uc (kV)
8,8; 12,8; 13,2; 15,2; 16,4; 17,2; 17,6; 18,4; 19,2; 19,6; 20,4; 20,8; 8,8; 12,8; 13,2; 15,2; 16,4; 17,2; 17,6; 18,4; 19,2; 19,6; 20,4; 20,8;
21,6; 22,4; 22,8; 23,6; 24,8; 25,2; 26,4; 26,8; 27,2; 28,4; 21,6; 22,4; 22,8; 23,6; 24,8; 25,2; 26,4; 26,8; 27,2; 28,4;
29,2; 29,6; 30,4; 30,8; 31,2; 32,4; 32,8; 33,2; 33,6; 34,4; 29,2; 29,6; 30,4; 30,8; 31,2; 32,4; 32,8; 33,2; 33,6; 34,4;
34,8; 35,2; 35,6; 36,8; 37,2; 38,4; 39,2; 39,6; 41,6; 42,8. 34,8; 35,2; 35,6; 36,8; 37,2; 38,4; 39,2; 39,6; 41,6; 42,8.
26
SN odvodniki prenapetosti MV surge arresters 2
2.4 2SS15N - oblika R 2.4 2SS15N - shape R
M12x25
www.izoelektro.com
2SS15N
Uc= kV Ur= kV In=10kA
29
H±5
11 12 1
10 2
9 3
8 4
7 6 5
M12x20
ø70
ø120
Koda Uc Ur Ures CD AD A B H
Code (kV) (kV) (kV) (mm) (mm) (mm) (mm) (mm)
21 48 01 3 3,75 9 60 90
21 48 02 4 5,00 13 360 139 80 100 147
21 48 03 6 7,50 22 100 120
21 48 04 8 10,00 31 120 140
21 48 05 10 12,50 35 520 185 140 160 193
21 48 06 12 15,00 39 160 180
21 48 07 14 17,50 47 180 200
21 48 08 16 20,00 51 600 235 200 220 243
21 48 09 18 22,50 60 220 240
21 48 10 20 25,00 64 240 260
21 48 11 21 26,25 68 680 262 260 280 270
21 48 12 22 27,50 72 270 300
21 48 22 24 30,00 76 320 320
21 48 13 24 30,00 76 320 320
21 48 14 26 32,50 85 760 309 340 340 317
21 48 15 28 35,00 88 360 360
21 48 16 30 37,50 97 295 380
21 48 17 32 40,00 101 1000 362 380 400 370
21 48 23 36 45,00 114 420 440
21 48 18 34 42,50 110 400 420
21 48 24 35 43,75 113 1080 396 410 430 404
21 48 19 36 45,00 114 420 440
21 48 26 40,5 50,60 132 450 470
Ures - preostala napetost pri 10kA (8/20 µs) Ures - residual voltage at 10kA (8/20 µs)
CD - plazilna pot CD - creepage distance
AD - preskočna razdalja AD - arcing distance
A - minimalna razdalja do stene A - minimum distance to wall
B - minimalna razdalja med fazami B - minimum distance between phases
www.izoelektro.com 27
2 SN odvodniki prenapetosti MV surge arresters
M12x25
2SS15N
Uc= kV Ur= kV In=10kA
Class I Isc=20kA
www.izoelektro.com
32
H±5
11 12 1
10 2
9 3
8 4
7 6 5
M12x20
54
Ø140
Koda Uc Ur Ures CD AD A B H
Code (kV) (kV) (kV) (mm) (mm) (mm) (mm) (mm)
221 48 01 3 3,75 9 60 90
221 48 02 4 5,00 13 80 100
343 154 136
221 48 03 6 7,50 22 100 120
221 48 04 8 10,00 31 120 140
221 48 05 10 12,50 35 140 160
453 186 168
221 48 06 12 15,00 39 160 180
221 48 07 14 17,50 47 180 200
563 218 200
221 48 08 16 20,00 51 200 220
221 48 09 18 22,50 60 220 240
674 250 232
221 48 10 20 25,00 64 240 260
221 48 11 21 26,25 68 260 280
221 48 12 22 27,50 72 784 282 270 300 263
221 48 13 24 30,00 76 300 320
221 48 14 26 32,50 85 320 340
894 314 295
221 48 15 28 35,00 88 340 360
221 48 16 30 37,50 97 360 380
1004 345 327
221 48 17 32 40,00 101 380 400
221 48 18 34 42,50 110 400 420
1114 377 359
221 48 19 36 45,00 114 420 440
221 48 20 38 47,50 124 440 460
221 48 21 40 50,00 130 450 470
1234 409 391
221 48 22 42 52,50 138 460 480
221 48 23 44 55,00 143 470 490
Ures - preostala napetost pri 10kA (8/20 µs) Ures - residual voltage at 10kA (8/20 µs)
CD - plazilna pot CD - creepage distance
AD - preskočna razdalja AD - arcing distance
A - minimalna razdalja do stene A - minimum distance to wall
B - minimalna razdalja med fazami B - minimum distance between phases
28
SN odvodniki prenapetosti MV surge arresters 2
2.6 2SS15N - oblika RO 2.6 2SS15N - shape RO
700 ± 10%
www.izoelektro.com
2SS15N
Uc= kV Ur= kV In=10kA
29
H±5
11 12 1
10 2
9 3
8 4
7 6 5
M12x20
ø70
ø120
Koda Uc Ur Ures CD AD A B H
Code (kV) (kV) (kV) (mm) (mm) (mm) (mm) (mm)
21 49 01 3 3,75 9 60 90
21 49 02 4 5,00 13 491 257 80 100 129
21 49 03 6 7,50 22 100 120
21 49 04 8 10,00 31 120 140
21 49 05 10 12,50 35 651 303 140 160 175
21 49 06 12 15,00 39 160 180
21 49 07 14 17,50 47 180 200
21 49 08 16 20,00 51 731 353 200 220 225
21 49 09 18 22,50 60 220 240
21 49 10 20 25,00 64 240 260
21 49 11 21 26,25 68 811 380 260 280 252
21 49 12 22 27,50 72 270 300
21 49 20 24 30,00 76 320 320
21 49 13 24 30,00 76 320 320
21 49 14 26 32,50 85 891 427 340 340 299
21 49 15 28 35,00 88 360 360
21 49 16 30 37,50 97 295 380
21 49 17 32 40,00 101 1131 480 380 400 352
21 49 21 36 45,00 114 420 440
21 49 18 34 42,50 110 400 420
21 49 24 35 43,75 113 1211 517 410 430 386
21 49 19 36 45,00 114 420 440
21 49 26 40,5 50,60 132 450 470
Ures - preostala napetost pri 10kA (8/20 µs) Ures - residual voltage at 10kA (8/20 µs)
CD - plazilna pot CD - creepage distance
AD - preskočna razdalja AD - arcing distance
A - minimalna razdalja do stene A - minimum distance to wall
B - minimalna razdalja med fazami B - minimum distance between phases
www.izoelektro.com 29
2 SN odvodniki prenapetosti MV surge arresters
700 ± 10%
11 12 1
10 2
9 3
8 4
7 6 5
M12x20
ø70
Koda Uc Ur Ures CD AD A B H
Code (kV) (kV) (kV) (mm) (mm) (mm) (mm) (mm)
21 59 01 3 3,75 9 60 90
21 59 02 4 5,00 13 243 215 408 100 129
21 59 03 6 7,50 22 508 120
21 59 04 8 10,00 31 120 140
21 59 05 10 12,50 35 289 271 683 160 175
21 59 06 12 15,00 39 887 180
21 59 07 14 17,50 47 180 200
21 59 08 16 20,00 51 339 321 200 220 225
21 59 09 18 22,50 60 220 240
21 59 10 20 25,00 64 240 260
21 59 11 21 26,25 68 366 348 260 280 252
21 59 12 22 27,50 72 270 300
21 59 20 24 30,00 76 320 320
21 59 13 24 30,00 76 320 320
21 59 14 26 32,50 85 413 395 340 340 299
21 59 15 28 35,00 88 360 360
21 59 16 30 37,50 97 295 380
21 59 17 32 40,00 101 466 418 380 400 352
21 59 21 36 45,00 114 420 440
21 59 18 34 42,50 110 400 420
21 59 24 35 43,75 113 500 482 410 430 386
21 59 19 36 45,00 114 420 440
21 59 26 40,5 50,60 132 450 470
Ures - preostala napetost pri 10kA (8/20 µs) Ures - residual voltage at 10kA (8/20 µs)
CD - plazilna pot CD - creepage distance
AD - preskočna razdalja AD - arcing distance
A - minimalna razdalja do stene A - minimum distance to wall
B - minimalna razdalja med fazami B - minimum distance between phases
30
SN odvodniki prenapetosti MV surge arresters 2
2.8 SNO in 2SS15N - primer naročila 2.8 SNO and 2SS15N - order example
Priključek A
Connector A
SNO
Uc=24kV Ur=30kV In=10kA
Class DH Isc=20kA
www.izoelektro.com
SNO-RP
11 12 1
10 2
9 3
8 4
7 6 5
Priključek N
Connector N
Naziv/Name: SNO-RP 24 kV + AN
www.izoelektro.com 31
2 SN odvodniki prenapetosti MV surge arresters
25
M12
M12
ø7,5-22,4
60
M12
32
SN odvodniki prenapetosti MV surge arresters 2
2.12 Priključek D 2.12 Connector D
Opis: vijačni priključek za PIV ø9-16 mm Description: screw connector for CC ø9-16 mm
Koda: 21 47 04 Code: 21 47 04
60
100
ø9-16
M12
M12
71
71
ø10-22,4 ø7,5-10
M12 M12
34 34
74
M12
34
www.izoelektro.com 33
2 SN odvodniki prenapetosti MV surge arresters
80
M12
M12 ø13,5
14
105
M12 ø13,5
14
105
34
SN odvodniki prenapetosti MV surge arresters 2
2.18 Priključek N 2.18 Connector N
Opis: izolacijski nosilec R s SN priključkom G Description: insulative bracket R with MV connector G
Koda: 21 47 24 Code: 21 47 24
M12 ø13,5
14
105
M12 ø11
5
125
M12
ø11
5
125
www.izoelektro.com 35
2 SN odvodniki prenapetosti MV surge arresters
144 60
40
14
ø13,5 ø13,5
40
20 125 15 40
5
1
ø13 ø1
60
20 125 15 5
3
ø1
1
ø1
40
36
SN odvodniki prenapetosti MV surge arresters 2
2.24 SN indikatorja stanja - splošno 2.24 MV condition indicators - generally
Proizvod Product
Odklopna naprava ON in indikator stanja odvodnika Disconnecting device ON and condition indicator ISOP
prenapetosti ISOP sta indikatorja stanja SN odvodnikov are indicators of MV surge arresters condition. During
prenapetosti. Določata uporabnost vgrajenih odvodnikov operation they monitor functionality and determine
med obratovanjem. usability of installed surge arresters.
Lastnosti Characteristics
ON - odklopna naprava ON - disconnecting device
Reagira pri tokovni preobremenitvi. Ozemljitveni vodnik It reacts at current overload. Surge arrester’s earthing
odvodnika prenapetosti, pritrjen na odklopno napravo, se conductor, which is attached to ON, sunders from the device
po reagiranju oddvoji od odklopne naprave. V tem primeru after functioning. In this case both surge arrester and the
je potrebno zamenjati odvodnik prenapetosti in odklopno disconnecting device need to be replaced.
napravo.
ISOP - indikator stanja odvodnika prenapetosti. ISOP - condition indicator for surge arresters.
Indikator brez daljinske komande ne potrebuje zunanjega Indicator without remote command does not need an
napajanja. ISOP reagira pri: external power source. ISOP reacts at:
• trajno previsokem uhajavem toku, • to high leakage current,
• atmosferskih praznjenjih nad 100 kA. • atmospheric discharges over 100 kA.
Po delovanju ISOP brez daljinske komande je potrebno After ISOP without remote command functions the device
indikator stanja zamenjati. Okvara odvodnika je vidna needs to be replaced. Defect on surge arrester is shown
tako, da se zelena površino indikatorja zamenja z rdečo. when green surface on device colours red. Remotely
Daljinsko voden indikator stanja ISOP upravljamo iz centra controlled condition indicator ISOP is managed from a
vodenja. command centre.
Vgradnja Installation
ON ON
pritrdimo ga na prosto viseči odvodnik prenapetosti ali is fitted to a freely hanging surge arrester or to a surge
odvodnik prenapetosti pritrjen na izolacijsko konzolo. arrester fixed to an insulating bracket.
ISOP ISOP
je namenjen za zunanjo in notranjo montažo. Indikator is applicable for outdoor and indoor installation.
okvare pritrditi na ustrezni višini tako, da čelno stran Condition indicator needs to be placed on an adequate
indikatorja namestimo v vidno polje. height with front side visible.
www.izoelektro.com 37
2 SN odvodniki prenapetosti MV surge arresters
40
M12
90
70
160
M10
160
200 200
ISOP M ISOP R
38
3
SN MV
natezni/nosilni tension/suspension
izolatorji insulators
3 SN natezni izolatorji MV tension insulators
Lastnosti Characteristics
Natezni/nosilni kompozitni izolatorji NKI so: Tension/suspension composite insulators NKI are:
• odporni na UV sevanje in kemične vplive, • resistant to UV radiation and chemical influences,
• obstojni na vremenske vplive in staranje, • resistant to weathering and aging,
• oplaščeni s silikonom brez dodatkov, • coated with silicone without additives,
• primerni za agresivna okolja (industrija, morska obala • suitable for aggressive environments (industry,
in puščavsko podnebje,…), seaside and desert climate,…),
• neobčutljivi na udarce. • insensitive to impacts.
Vgradnja Installation
Mesto montaže nateznih/nosilnih kompozitnih izolatorjev The position for installing tension composite insulators NKI
NKI določajo pravilniki in tehnični predpisi. Vgrajujejo is decided by directives and technical regulations. They
se v novogradnje, rekonstrukcije in pri vzdrževanju. Ne are being installed in new constructions, reconstructions
glede na druge že vgrajene izolatorje v daljnovodih, and at maintenance. Newly installed NKI insulators have no
novo vgrajeni NKI izolatorji ne vplivajo na spremembo impact on any change of insulation coordination regardless
koordinacije izolacije. to previous installed insulators in overhead power lines.
40
SN natezni izolatorji MV tension insulators 3
3.2 NKI uho-uho 3.2 NKI eye-eye
28
522 ± 10
35
286
35
458 ± 10
34
418 ± 10
222
385 ± 10
182
253
ø98 ø98 ø116 ø120
28
522 ± 10
35
286
35
458 ± 10
34
418 ± 10
222
385 ± 10
182
253
NKI N/UU 90° NKI L/UU 90° NKI M/UU 90° NKI X/UU 90°
www.izoelektro.com 41
3 SN natezni izolatorji MV tension insulators
!
NOVO
!
NEW
Izoelektro
28
80 kN
Izoelektro
Izoelektro
35
510 ± 10
80 kN
286
Izoelektro
35
450 ± 5 80 kN
34
80 kN
222
410 ±10
370 ± 5
182
253
11 12 1 11 12 1
10 2 11 12 1 10 2
10 2
9 3 9 3 9 3
8 4 8 4 8 4
7 5 7 5
6 6 7 6 5
11 12 1
10 2
NKI N NKI L
9
8
7
6
5
4
3
NKI X
!
NOVO
!
NEW Izoelektro
28
80 kN
Izoelektro
Izoelektro
35
510 ± 10
80 kN
286
Izoelektro
35
80 kN
450 ± 5
34
80 kN
222
410 ±10
370 ± 5
182
253
11 12 1 11 12 1
11 12 1 10 2 10 2
10 2
9 3 9 3
9 3 8 4
8 4
8 4 7 5 7 5
7 5 6 6
6
11 12 1
10 2
NKI X
9 3
NKI N NKI L
8 4
7 5
6
NKI N/OO 90° NKI L/OO 90° NKI M/OO 90° NKI X/OO 90°
42
SN natezni izolatorji MV tension insulators 3
3.6 NKI batič-batič 3.6 NKI ball-ball
28
493 ± 10
35
286
35
429 ± 10
34
389 ± 10
222
352 ± 10
182
253
ø98 ø98 ø116 ø120
28
482 ± 10
35
286
35
418 ± 10
34
378 ± 10
222
342 ± 10
182
253
www.izoelektro.com 43
3 SN natezni izolatorji MV tension insulators
28
499 ± 10
35
286
35
435 ± 10
34
395 ± 10
222
358 ± 10
182
253
ø98 ø98 ø116 ø120
28
508 ± 10
35
286
444 ± 10
35
34
404 ± 10
222
366 ± 10
182
253
44
SN natezni izolatorji MV tension insulators 3
3.10 NKI ponvica-uho 3.10 NKI socket-eye
28
35
502 ± 10
286
35
34
438 ± 10
222
398 ± 10
182
362 ± 10
253
ø98 ø98 ø116 ø120
28
35
511 ± 10
286
35
447 ± 10
34
407 ± 10
222
369 ± 10
182
253
www.izoelektro.com 45
3 SN natezni izolatorji MV tension insulators
28
488 ± 10
35
286
35
424 ± 10
34
384 ± 10
222
346 ± 10
182
253
ø98 ø98 ø116 ø120
28
496 ± 10
35
286
35
432 ± 10
34
392 ± 10
222
355 ± 10
182
253
46
SN natezni izolatorji MV tension insulators 3
3.14 NKI ponvica-vilica 3.14 NKI socket-clevis
28
35
491 ± 10
286
35
427 ± 10
34
387 ± 10
222
350 ± 10
182
253
ø98 ø98 ø116 ø120
28
499 ± 10
35
286
35
435 ± 10
34
395 ± 10
222
358 ± 10
182
253
NKI N/VV 90° NKI L/VV 90° NKI M/VV 90° NKI X/VV 90°
www.izoelektro.com 47
3 SN natezni izolatorji MV tension insulators
28
528 ± 10
35
286
35
464 ± 10
34
424 ± 10
222
387 ± 10
182
253
ø98 ø98 ø116 ø120
28
528 ± 10
35
464 ± 10
286
35
424 ± 10
34
222
387 ± 10
182
253
48
SN natezni izolatorji MV tension insulators 3
3.18 NKI izolatorji - primer naročila 3.18 NKI insulators - order example
19 ø14
ø25 30
22
M10
42
50
ø5,5
M5
22
U I I 3/4'' P
O Y B V
www.izoelektro.com 49
3 SN natezni izolatorji MV tension insulators
3.19 NKI enojna zatezna veriga 3.19 NKI single tension string
Opomba: SZ-U sponka (poz. 1) omogoča Note: SZ-U clamp (pos. 1) allows fastening
vpetje v dveh ravninah into two planes
2 1
l ± 10 mm
3.20 NKI enojna zatezna veriga z iskriščem 3.20 NKI single tension string with arcing horn
Opomba: SZ-U sponka (poz. 1) omogoča vpetje Note: SZ-U clamp (pos. 1) allows fastening
v dveh ravninah into two planes
140-160
3 2 3 1
Naziv Koda l Poz. Kos Koda Masa
Name Code (mm) Pos. Pcs Code Mass
(kg)
1 1 80 60 03 1,1
EZI-01 N/UU 91 70 55 590 2 1 80 70 55 1,0
3 2 80 70 54 0,3
1 1 80 60 03 1,1
l ± 10 mm
EZI-01 L/UU 91 70 57 630 2 1 80 70 57 1,1
ali / or 3 2 80 70 54 0,3
140-160
1 1 80 60 03 1,1
EZI-01 M/UU 91 71 00 557 2 1 80 71 00 1,1
3 2 1 3 2 80 70 54 0,3
1 1 80 60 03 1,1
EZI-01 X/UU 91 70 59 686 2 1 80 70 59 1,3
3 2 80 70 54 0,3
l ± 10 mm
50
SN natezni izolatorji MV tension insulators 3
3.21 NKI dvojna zatezna veriga 3.21 NKI double tension string
Opomba: SZ-U sponka (poz. 1) omogoča Note: SZ-U clamp (pos. 1) allows fastening
vpetje v dveh ravninah into two planes
3.22 NKI enojna nosilna veriga 3.22 NKI single suspension string
1 1 80 60 04 0,7
EN-01 M/UU 92 71 00 478
2 1 80 71 00 1,1
1 1 80 60 04 0,7
EN-01 X/UU 92 70 59 607
2 1 80 70 59 1,3
www.izoelektro.com 51
3 SN natezni izolatorji MV tension insulators
3.23 NKI enojna nosilna veriga 90° 3.23 NKI single suspension string 90°
1 1 80 60 04 0,7
EN-02 X/UU 92 70 84 607
2 1 80 70 84 1,3
3.24 NKI enojna nosilna veriga 3.24 NKI single suspension string
z iskriščem with arcing horn
Opomba: uporaba za polizolirane vodnike (PIV) Note: use with covered conductors (CC)
3 3 2 80 70 54 0,3
2
1 1 80 60 04 0,7
l ± 10 mm
52
SN natezni izolatorji MV tension insulators 3
3.25 NKI enojna nosilna veriga 90° 3.25 NKI single suspension string 90°
z iskriščem with arcing horn
Opomba: uporaba za polizolirane vodnike (PIV) Note: use with covered conductors (CC)
140-160
3 1 1 80 60 04 0,7
2
l ± 10 mm
3.26 NKI dvojna nosilna veriga 3.26 NKI double suspension string
2 2 80 70 57 1,1
DN-01 L/UU 94 70 58 750
3 2 43 29 408 1,6
4 1 80 60 30 0,5
3 1 1 80 60 04 0,7
2 2 80 71 00 1,1
DN-01 M/UU 94 71 00 677
4 3 2 43 29 408 1,6
4 1 80 60 30 0,5
1 1 80 60 04 0,7
1
2 2 80 70 59 1,3
DN-01 X/UU 94 70 57 806
3 2 43 29 408 1,6
4 1 80 60 30 0,5
www.izoelektro.com 53
3 SN natezni izolatorji MV tension insulators
3.27 NKI dvojna nosilna veriga 90° 3.27 NKI double suspension string 90°
54
SN natezni izolatorji MV tension insulators 3
3.28 NKI izolatorska veriga - 3.28 NKI insulator string -
primer naročila 1 order example 1
Podaljšek jeklen
Steel extension link
L/UU - uporabljen je naziv nateznega L/UU - use the name of the tension
kompozitnega izolatorja brez oznake NKI composite insulator without the mark NKI.
www.izoelektro.com 55
3 SN natezni izolatorji MV tension insulators
l ± 10 mm
N/UU - uporabljen je naziv nateznega N/UU - use the name of the tension
kompozitnega izolatorja brez oznake NKI composite insulator without the mark NKI.
56
4
SN podporni MV post
izolatorji insulators
4 SN podporni izolatorji MV post insulators
Lastnosti Characteristic
Podporni kompozitni izolatorji PKI so: Post composite insulators PKI are:
• odporni na UV sevanje in kemične vplive, • resistant to UV radiation and chemical influences,
• obstojni na vremenske vplive in staranje, • resistant to weathering and aging,
• oplaščeni s silikonom brez dodatkov, • coated with silicone without additives,
• primerni za agresivna okolja (industrija, morska obala • suitable for aggressive environments (industry,
in puščavsko podnebje), seaside and desert climate),
• uporabni za daljnovode in naprave, • usable for overhead power lines and devices,
• neobčutljivi na udarce. • insensitive to impacts.
Vgradnja Installation
Mesto montaže podpornih kompozitnih izolatorjev PKI The position for installing post composite insulators PKI is
določajo pravilniki in tehnični predpisi. Vgrajujejo se v decided by directives and technical regulations. They are
novogradnje, rekonstrukcije in pri vzdrževanju. Prigrajena being installed in new constructions, reconstructions and
vzmetna sponka z ustreznim jahačem zagotavlja tovarniško at maintenance. The fitted spring clamp provides factory-
nastavljeno vertikalno in horizontalno izvlečno silo. Ne set vertical and horizontal pull-out force by using the
glede na druge že vgrajene izolatorje v daljnovodih, appropriate cover. Newly installed PKI insulators have no
novo vgrajeni PKI izolatorji ne vplivajo na spremembo impact on any change of insulation coordination regardless
koordinacije izolacije. to previous installed insulators in overhead power lines.
58
SN podporni izolatorji MV post insulators 4
4.2 PKI inovacija 4.2 PKI innovation
Izkušnje uporabnikov in termovizijski posnetki daljnovodov Experiences of users and thermo-vision snaps of power
dokazujejo, da v času življenjske dobe prihaja do parcialnih lines are proving that in the lifespan partial discharges
praznitev, kadar je goli ali pol izoliran vodnik: occur when a bare conductor or a covered conductor is:
• vpet v kovinsko pritrdišče, • fastened to a metal anchorage,
• pritrjen s kovinsko vezjo na keramični izolator. • astened with the metal bond to the ceramic insulator.
Študija porazdelitve električne poljske jakosti na zgornjem The study of distribution of electric field strength on metal
kovinskem priključku kompozitnega podpornega top end fitting of composite post insulators confirms high
izolatorja potrjuje, da obstaja velika verjetnost, da bo probability of too high electric field strength (at prolonged
zaradi previsoke električne poljske jakosti ob dolgotrajni usage of insulators with top end metal fitting). It will come
uporabi izolatorjev z zgornjim kovinskim priključkom prišlo to burns at the lower end point of the top end fitting or the
do prežiga na mestu spodnjega roba zgornjega priključka conductor will burn off from the fixation place.
izolatorja ali do odžiga vodnika na mestu pritrditve. Some theoretical research showed that while in operation
Teoretične raziskave so pokazale, da se v obratovanju a non-homogenous electric field that depends on material
vzdolž izolatorja vzpostavi električno polje, ki ni homogeno, characteristics and insulator geometry is established
temveč je odvisno od lastnosti materialov in geometrije. To along the insulator. This affects the dielectric loads of the
vpliva na dielektrične obremenitve izolatorja, ki so odvisne insulator that depend upon the shape of conducting parts
od oblike prevodnih delov in rastejo z velikostjo napetosti and increase with the heights of voltage U or electric
U oziroma električnega polja E. field E.
4,0
MEJNA VREDNOST
3,0
2,0
1,0
izolator z izolacijsko glavo
-150 -90 -30 30 90 150
(mm)
www.izoelektro.com 59
4 SN podporni izolatorji MV post insulators
,5
R12
,5 ,5 R12,5
R12 R12
22,5
R12,5 R12,5
25
330 ± 5
50
285 ± 5
285 ± 5
M M M
Ø59 Ø59 Ø59
Ø120 Ø140
,5
R12
R12,5
R12,5 R 12,5
22,5
R12,5 R12,5
25
330 ± 5
50
285 ± 5
285 ± 5
M M M
Ø120 Ø140
60
SN podporni izolatorji MV post insulators 4
4.5 PKI z vzmetno sponko 4.5 PKI with spring clamp
Horizontalna izvlečna sila vodnika (Fh): 1,2 kN Horizontal pull-out force of conductor (Fh): 1,2 kN
Vertikalna dopustna obremenitev sponke (Fv): 2,8 kN Vertical maximum load of clamp (Fv): 2,8 kN
22,5
25
365 ± 5
320 ± 5
320 ± 5
50
M M M
Ø59 Ø59 Ø59
Ø120 Ø140
365 ± 5
320 ± 5
320 ± 5
50
M M M
Ø120 Ø140
www.izoelektro.com 61
4 SN podporni izolatorji MV post insulators
22,5
25
365 ± 5
320 ± 5
320 ± 5
50
M M M
Ø59 Ø59 Ø59
Ø120 Ø97 Ø110
Ø120 Ø140
!
NOVO
22,5
!
NEW
25
340 ± 5
50
305 ± 5
305 ± 5
M M M
Ø59 Ø59 Ø59
Ø120 Ø97 Ø110
Ø120 Ø140
62
SN podporni izolatorji MV post insulators 4
4.9 A PKI z oslabljeno vzmetno sponko 4.9 A PKI with weakened spring clamp
Horizontalna izvlečna sila vodnika (Fh): 1,2 kN Horizontal pull-out force of conductor (Fh): 1,2 kN
Vertikalna dopustna obremenitev sponke (Fv): 2,8 kN Vertical maximum load of clamp (Fv): 2,8 kN
!
NOVO
22,5
!
NEW
25
340 ± 5
305 ± 5
50
305 ± 5
!
NOVO
22,5
!
NEW
25
340 ± 5
305 ± 5
305 ± 5
50
M M M
Ø59 Ø59 Ø59
Ø120 Ø140
www.izoelektro.com 63
4 SN podporni izolatorji MV post insulators
!
NOVO
!
NEW
22,5
25
340 ± 5
305 ± 5
305 ± 5
50
M M M
Ø59 Ø59 Ø59
4.12 PKI za vodnik AlFe 120/PIV 99 4.12 A PKI for conductor AlFe 120/PIV 99
Horizontalna izvlečna sila vodnika (Fh): 5,6 kN Horizontal pull-out force of conductor (Fh): 5,6 kN
Vertikalna dopustna obremenitev sponke (Fv): 5,8 kN Vertical maximum load of clamp (Fv): 5,8 kN
!
NOVO
!
NEW
22,5
25
340 ± 5
305 ± 5
305 ± 5
50
M M M
Ø59 Ø59 Ø59
64
SN podporni izolatorji MV post insulators 4
4.13 A PKI z vijačno sponko 4.13 A PKI with screw clamp
Horizontalna izvlečna sila vodnika (Fh): 2,8 kN Horizontal pull-out force of conductor (Fh): 2,8 kN
Vertikalna dopustna obremenitev sponke (Fv): 4,0 kN Vertical maximum load of clamp (Fv): 4,0 kN
Opomba: Vijaka sponke privijemo z navorom 8 Nm Note: Tighten the screws on the clamp with a torque 8 Nm
!
NOVO
22,5
!
NEW
25
343 ± 5
308 ± 5
308 ± 5
50
M M M
Ø59 Ø59 Ø59
Ø120 Ø140
4.14 PKI E za vodnike od ø15 do ø30 4.14 PKI E for conductor from ø15 to ø30
Opomba: Možnost uporabe v kombinaciji s kapo SZM/0 Note: Can be used in combination with a cap SZM/0
!
NOVO
22,5
!
NEW
25
350 ± 5
308 ± 5
308 ± 5
50
M M M
Ø59 Ø59 Ø59
Ø120 Ø140
www.izoelektro.com 65
4 SN podporni izolatorji MV post insulators
M12 Ø7 M8 M8
36
22,5
19 36
25
50
320 ± 5
280 ± 5
280 ± 5 20 20
8
M12 Ø7 M16 Ø5 M16 Ø5
!
NEW M
22
M
343 ± 5
22
299 ± 5
255 ± 5
22
211 ± 5
167 ± 5
22
M M M M M
Ø40 Ø40 Ø40 Ø40 Ø40
66
SN podporni izolatorji MV post insulators 4
4.17 A PKI in PKI nagib in odkloni 4.17 A PKI and PKI inclination and
vodnika declination of conductor
Opomba: podani so maksimalni nagibi in odkloni vodnika v Note: the data in the table is for the maximum inclinations
glavi izolatorjev A PKI in PKI glede na način vpetja vodnika. and declinations of conductors in the insulator’s head A
PKI and PKI in the way of mounting.
55°
Vrtišče
Nagib Fulcrum Inclination
glave izolatorja of insulator top
15°
15°
15°
15°
Odklon vodnika Declination of
vertikalno conductor vertical
15°
15°
15°
15°
30°
30°
15°
15°
15°
30°
30°
Nagib Inclination
55°
15°
15°
15°
15°
www.izoelektro.com 67
4 SN podporni izolatorji MV post insulators
Lastnosti Characteristic
Podporni kompozitni izolatorji A PKI z oznako »B« imajo Post composite insulators A PKI with mark »B« have a
prigrajeno kapo za zaščito kovinskih delov glave fitted hat for protecting metal parts of head of a composite
kompozitnega izolatorja. Silikonski plašč SILP, montiran insulator. The silicone coat SILP mounted on the conductor
na vodniku na vsaki strani izolatorja, izolira goli vodnik insulates the bare conductor attached to the insulator
pritrjen na izolator. Vijačna sponka privita z predpisanim on each side of the insulator. Screw clamp screwed with
navorom zagotavlja zdrs vodnika skozi silikonski plašč the specified torque ensures slippage of the conductor
SILP istočasno pa onemogoča premik silikonskega plašča through the silicone coat SILP at the same time prevents
glede na mesto pritrditve. the movement of a silicon coat according to the site of
attachment.
Vgradnja Installation
Mesto montaže sistema zaščite za ptice določajo pravilniki The position for installing the system of birds’ protection is
in tehnični predpisi elektrodistribucij. Priporočamo decided by directives and technical regulations of electrical
vgradnjo na daljnovodih, kjer pogosto prihaja do distributors. We recommend installation on overhead power
zemeljskih stikov zaradi: lines wherever earth faults often occur because of:
• večjih ptic, • larger birds,
• preskakovanja glodalcev na oporiščih. • rodents jumping on poles.
V našem podjetju smo skupaj z uporabniki razvili sistem Together with users we created a system for installing
za vgradnjo tipskih zaščitnih elementov. Za izvedbo standard protective elements. For implementing the
sistema zaščite za ptice je potrebno uporabiti: system “protection for birds” it is necessary to use:
Naročanje Ordering
Izberete kateri koli podporni kompozitni izolator A PKI z Choose any post composite insulator A PKI with mark
oznako »G«, kapo SZM/0 in priporočeno število metrov »G«, cap SZM/0 and the recommended number of meters
silikonskega plašča SILP. Primer garniture za en izolator of silicone coat SILP. Example for a single set insulator is
je podan v točki 4.19 A PKI zaščita za ptice. given in section 4.19 A PKI protection for birds
68
NN slo LV ang 4
4.19 Zaščita za ptice - garnitura 4.19 Protection for birds - set
Horizontalna izvlečna sila vodnika (Fh): 2,8 kN Horizontal pull-out force of conductor (Fh): 2,8 kN
Vertikalna dopustna obremenitev sponke (Fv): 4,0 kN Vertical maximum load of clamp (Fv): 4,0 kN
2m
2m
2m
A PKI NB A PKI XB
A PKI LB
Navodila za namestitev zaščite za ptice z vijačno sponko Installation instructions for the protection for birds with
screw clamp
1. S ilikonski plašč SILP 70/35 namestimo na vodnik 1. Silicone coat SILP 70/35 is installed on the conductur
simetrično na vijačno sponko. symmetrically to the screw clamp.
2m
2. Vijaka privijemo z navorom Mt=6 Nm. 2. Tighten the screws with a torque Mt=6 Nm.
Vijak M8 Mt Mt Screw M8
www.izoelektro.com 69
4 SN podporni izolatorji MV post insulators
4.20 PKI varna montaža skozi gozd 4.20 PKI safe installation through
splošno the woods generally
Proizvod Product
PKI izolatorji z oznako »V« so namenski podporni kompozitni PKI insulators with mark »V« are purposed post composite
izolatorji s silikonskim plaščem in z oslabljeno vzmetno insulators with silicone coating and a weakened spring
sponko. Namenjeni so za varno montažo skozi gozd. clamp shuttle. Their purpose is for a safe installation
Vgrajujemo jih v nadzemne električne vode do nazivne through the forest. They are designed to be installed on
napetosti 52 kV. overhead power lines with rated voltages up to 52 kV.
Lastnosti Characteristic
Podporni kompozitni izolatorji imajo oslabljeno telo sponke Post composite insulators have a weakened spring clamp
zaradi lažje porušitve pri izrednih vremenskih razmerah. shuttle for easier collapsing in extreme weather conditions.
Vgradnja Installation
Mesto montaže namenskih podpornih kompozitnih izolatorjev The position for installing purposed post composite insulators
PKI določajo pravilniki in tehnični predpisi elektrodistribucij. PKI is decided by directives and technical regulations of
Na daljnovodih, kjer trasa poteka skozi gozd, pogosto prihaja electrical distributors. On power lines passing through the
do prekinitev napajanja zaradi: woods often comes to interruptions of power supply due to:
• izrednih vremenskih razmer, • extreme weather conditions,
• podiranja dreves, • falling trees,
• lomljenja vej, • breaking branches,
• otresanja snega in žleda. • shaking off snow and ice.
V najhujših primerih prihaja do porušitve DV. Dejstvo je, In the worst-cases the collapse of the power line occurs.
da pri teh porušitvah v večini primerov ostane vodnik The fact is that at these collapses in most cases the
nepretrgan. conductor remains unbroken.
Zaradi tega smo v našem podjetju skupaj z uporabniki in For this reason our company conducted a study together
strokovnimi sodelavci izvedli študijo o varni izgradnji DV with users and technical staff on safe installation of PL
skozi gozd ter raziskave podkrepili s preskusom v naravi through the woods. The research was reinforced by a test
(video na www.izoelektro.com). Za izvedbo varne montaže in nature (video on www.izoelektro.com). To implement
skozi gozd so uporabljeni: safe installation through the woods use:
• izolatorji PKI z oslabljenim telesom sponke, • insulators PKI with weakened spring clamp shuttle,
• kavelj in • hook and
• varnostni lok vodnika. • conductor safety arc.
70
SN podporni izolatorji MV post insulators 4
4.21 PKI varna montaža skozi gozd - 4.21 PKI safe assembly through
primer the woods - example
140-160
m
D=1,2
www.izoelektro.com 71
4 SN podporni izolatorji MV post insulators
Jahač
Cover
4.23 A PKI izolatorji - primer naročila 4.23 A PKI insulators - order example
Fv
70
°
Fh
Priključek zgoraj
Top fitting
Priključek spodaj
Bottom fitting
A PKI, PKI - Tip SN kompozitnega izolatorja A PKI, PKI - Type of MV composite insulator
N, L, X - Plazilna pot N, L, X - Creepage distance
S, O, H, D, Z, M, G, B - Oblika priključka zgoraj S, O, H, D, Z, M, G, B - Shape of top end fitting
M24, M20 - Navoj priključka spodaj M24, M20 - Connector thread
on bottom end fitting
72
SN podporni izolatorji MV post insulators 4
Priključki zgoraj Top fittings
Ø58
,5 58
R12 ,5
R12
R12,5 R12,5 R12,5 R12,5
40
40
Ø58 Ø58
19
17
Ø11
O - brez sponke Ø11 H - brez sponke, z luknjo
O - without a clamp H - without a clamp, with a hole
,5
R12
Ø13
www.izoelektro.com 73
4 SN podporni izolatorji MV post insulators
20
Naziv Name Koda Premer vodnika
Code Conductor diameter
100 Jahač 35 PIV Cover 35 CC 11 12 08 9,5 – 11,5
Jahač 70 PIV Cover 70 CC 11 12 07 11,5 – 14,5
Jahač 99 PIV Cover 99 CC 11 12 12 17,5 – 19,0
Jahač 35 AlFe Cover 35 AlFe 11 12 09 7,5 – 8,2
Jahač 50 AlFe Cover 50 AlFe 11 12 10 8,2 – 9,5
35 PIV/CC 70 PIV/CC 99 PIV/CC 35 AlFe Jahač 70 AlFe Cover 70 AlFe 11 12 08 9,5 – 11,5
Jahač 95 AlFe Cover 95 AlFe 11 12 11 11,5 – 14,5
Jahač 120 AlFe Cover 120 AlFe 11 12 12 17,5 – 19,0
100
100
74
SN podporni izolatorji MV post insulators 4
4.27 PA sornik 4.27 PA bolt
Uporaba: pri zamenjavi PA telesa sponke v glavi Usage: at the replacement of PA clamp in
A PKI in PKI izolatorjev top fitting of A PKI and PKI insulators
Koda: 40 10 32 Code: 40 10 32
96
ø14
100
M8 M8
!
NOVO
18,5
!
NEW
18
100
www.izoelektro.com 75
4 SN podporni izolatorji MV post insulators
l
4,8
M10
76
SN podporni izolatorji MV post insulators 4
4.33 SN vzmet 4.33 MV spring
Uporaba: pri PA telo sponke Usage: for PA body of spring clamp
Koda: 12 10 01 Code: 12 10 01
43
43 39
M2
M16
www.izoelektro.com 77
4 SN podporni izolatorji MV post insulators
Beležke Notes
78
5
DV pribor PL accessories
5 DV pribor PL accessories
5.1 SZ-U sponka zatezna univerzalna 5.1 SZ-U universal tension clamp
Moment: 45 Nm Torque: 45 Nm
Premer vodnika AlFe: 6,8-14,0 mm Conductor diameter AlFe: 6,8-14,0 mm
Koda: 80 60 03 Code: 80 60 03
25
20
179
139 53
5.2 SN-U sponka nosilna univerzalna 5.2 SN-U universal suspension clamp
Moment: 45 Nm Torque: 45 Nm
Premer vodnika AlFe: 6,8-14,0 mm Conductor diameter AlFe: 6,8-14,0 mm
Koda: 80 60 04 Code: 80 60 04
ø16
150
50 85
130
Fh = 1,2 kN
82,5
ø70 - 105
80
DV pribor PL accessories 5
5.4 VS 25 sponka vzmetna 5.4 VS 25 spring clamp
Moment: 25 Nm Torque: 25 Nm
Premer vodnika AlFe: 6,8-18,8 mm Conductor diameter AlFe: 6,8-18,8 mm
Nagib vodnika: 70° Inclination conductor: 70°
Koda: 10 10 02 Code: 10 10 02
Fv = 2,8 kN
100
Fh = 1,2 kN
82,5
ø80 - 115
5.5 VS SER b-20 sponka vzmetna 5.5 VS SER b-20 spring clamp
z izolatorjem with insulator
Premer vodnika AlFe: 6,8-18,8 mm Conductor diameter AlFe: 6,8-18,8 mm
Nagib vodnika: 55° Conductor inclination: 55°
Koda: 66 33 038 Fv = 2,8 kN Code: 66 33 038
Fh = 1,2 kN
240
Rd 28x1/8"
ø175
5.6 VS SER b-25 sponka vzmetna 5.6 VS SER b-25 spring clamp
z izolatorjem with insulator
Premer vodnika AlFe: 6,8-18,8 mm Fv = 2,8 kN Conductor diameter AlFe: 6,8-18,8 mm
Nagib vodnika: 55° Conductor inclination: 55°
Koda: 66 33 039 Code: 66 33 039
Fh = 1,2 kN
270
Rd 28x1/8"
ø205
www.izoelektro.com 81
5 DV pribor PL accessories
Fv = 2,8 kN
Fh = 1,2 kN
345
fi150
M20
ø130
Fh = 1,2 kN
350
ø170
M20
ø130
82
DV pribor PL accessories 5
5.9 DSI S distančnik izolacijski 5.9 DSI S insulating spacer
z vzmetno sponko with spring clamp
Izvedba: z vzmetno sponko Version: with spring clamp
l (mm): 0400 - 4100 l (mm): 0400 - 4100
Koda: 24 xxxx * Code: 24 xxxx *
* xxxx = dolžina (l) v mm * xxxx = length (l) in mm
ø29
l
ø29
www.izoelektro.com 83
5 DV pribor PL accessories
8
92
3
ø17,5 x
130
ø16
32
18
92
130
17,5
84
140
23
8
55
84
DV pribor PL accessories 5
5.14 Podaljšek jeklen 90° 5.14 Steel extension link 90°
Minimalna prelomna sila: 90 kN Minimal breaking strength: 90 kN
Koda: 80 60 31 Code: 80 60 31
8
ø17,5
140
23
55
A
d
D
A
d
www.izoelektro.com 85
5 DV pribor PL accessories
45°
175
ø2
8
30
80
60
80
90
86
DV pribor PL accessories 5
5.20 Vijak ozemljitveni 5.20 Earthing screw
Naziv: Vijak ozemljitveni – rumen; koda: 70 76 01 Name: Earthing screw – yellow; code: 70 76 01
Naziv: Vijak ozemljitveni – črn; koda: 70 76 02 Name: Earthing screw – black; code: 70 76 02
Material: CuZn28, PA6 Material: CuZn28, PA6
Moment: 8 Nm Torque: 8 Nm
Naziv: Vijak ozemljitveni – rumen Cu; koda: 70 76 03 Name: Earthing screw – yellow Cu; code: 70 76 03
Naziv: Vijak ozemljitveni – črn Cu; koda: 70 76 04 Name: Earthing screw – black Cu; code: 70 76 04
Material: Cu, PA6 Material: Cu, PA6
ø21
M12x1,25
12
58
79
www.izoelektro.com 87
5 DV pribor PL accessories
Beležke Notes
88
6
6.1 R sponka ravna z dvojnim konusom 6.1 R double conoid flat clamp
d
ø (mm)
7 - 10 42 40 00 R10 11,3 70
7 - 13 42 40 01 R13 14,2 88
l
10 - 16 42 40 02 R16 16,6 102
16 - 20 42 40 03 R20 20,5 120
6.2 T sponka odcepna z dvojnim konusom 6.2 T double conoid branch clamp
l
Priključek Koda Tip h d l
Connector Code Type (mm) (mm) (mm)
ø (mm)
d
7 - 10 42 41 00 T10 41 11,3 82
7 - 13 42 41 01 T13 47 14,2 93
10 - 16 42 41 02 T16 60 16,6 118
h
l
Priključek Koda Tip h d d2 l
Connector Code Type (mm) (mm) (mm) (mm)
ø (mm)
d
90
SN koncentrični material MV connecting sleeves 6
6.4 Rp priključek ravni 6.4 Rp flat fitting
d
ø (mm)
7 - 10 42 42 00 Rp10 55 11,3 M12
l 7 - 13 42 42 01 Rp13 64 14,2 M16
10 - 16 42 42 02 Rp16 74 16,6 M20
16 - 20 42 42 03 Rp20 80 20,5 M24
d
Priključek Koda Tip D d d2 l
Connector Code Type (mm) (mm) (mm) (mm)
ø (mm)
7 - 10 42 44 00 P10 30 11,3 13 55
7 - 13 42 44 01 P13 33 14,2 17 64
10 - 16 42 44 02 P16 36 16,6 21 74
l
16 - 20 42 44 03 P20 39 20,5 25 80
d₂
b D
d₁
www.izoelektro.com 91
6 SN koncentrični material MV connecting sleeves
Beležke Notes
92
7
VN laboratorij HV laboratory
7 VN laboratorij HV laboratory
Obratovanje Operation
V podjetju imamo laborato- In the company, we have a labora-
rij, opremljen z napravami za tory equipped with devices for per-
opravljanje električnih in me- forming electrical and mechanical
hanskih meritev. V glavnem je measurements. We use the labo-
namenjen lastnim potrebam za ratory mostly for our own needs
izvajanje preskusov od razvo- to perform various tests from the
ja do validacije izdelka. Vršimo early phase of development to
tudi usluge za podjetja, razi- the final validation of a product.
skovalne institucije in izobra- We also perform services for oth-
ževalne ustanove. Na osnovi er companies, research institutes,
dobljenih rezultatov naši stro- and educational institutions. On
kovnjaki izdajajo preskusna bases of the results they get, our
poročila in strokovna mnenja. Natančnost meritev in ve- experts issue test reports and expert opinions. We assure
rodostojnost podatkov zagotavljamo z rednim umerjanjem accuracy of measurements and credibility of data with regular
instrumentov s strani akreditirane institucije. calibration of instruments from an accredited institution.
Preskusi izolatorjev se izvajajo z izmenično napetostjo do Insulators are tested using power frequency voltage up to
višine 220 kV in z udarno napetostjo oblike vala 1,2/50 µs 220 kV and the lightning impulse voltage with wave shape
do višine 500 kV. 1,2/50 µs up to 500 kV.
Z generatorjem tvorimo trajno izmenično napetost, ki se pri Generator forms a continuous power frequency voltage
izolatorjih uporablja za določanje zdržne napetosti v mokrem which is used to define a wet power frequency withstand
v skladu s standardi IEC 61109, IEC 61952 in IEC 60383. voltage at insulators in accordance with standards
Pri odvodnikih prenapetosti generator izmenične napetosti IEC 61109, IEC 61952 and IEC 60383.
uporabljamo za meritev referenčne napetosti v skladu s The same generator is used to define a reference voltage
standardi IEC 60099-4 in IEC 61643. Uporabljamo ga of surge arresters in accordance with IEC 60099-4 and
tudi za meritev ohmske komponente uhajavega toka IEC 61643. It is also used to measure a resistive component
odvodnikov prenapetosti. of the leakage current of surge arresters.
94
VN laboratorij HV laboratory 7
Oblike udarnih tokov Current impulses generated
Standardne: Standard:
• 4/10 μs • 4/10 μs
• 8/20 μs • 8/20 μs
• 10/350 μs • 10/350 μs
• dolgega trajanja 1 ms • long duration current 1 ms
• dolgega trajanja 2 ms • long duration current 2 ms
Nestandardne: Nonstandard:
• od 4/10 do 30/60 μs • from 4/10 μs to 30/60 μs
• od 250 do 2000 μs • from 250 μs to 2000 μs
Generator uporabljamo za delovne preskuse v skladu s The generator is used for operating duty tests in accordance
standardoma IEC 60099-4 in IEC 61643. with standards IEC 60099-4 and IEC 61643.
Digitalna naprava za merjene parcialnih praznitev Digital partial tester for measuring partial discharges
Napravo uporabljamo za merjenje parcialnih praznitev na Digital partial tester is used for measuring partial discharges
odvodnikih prenapetosti in izolatorjih z izmenično napetostjo on surge arresters and insulators with alternating voltage up
do 100 kV in natančnostjo 0,1 pC v skladu s standardom IEC to 100 kV and sensitivity 01 pC in accordance with standard
60270. IEC 60270.
www.izoelektro.com 95
7 VN laboratorij HV laboratory
Beležke Notes
96
Naziv podjetja Izoelektro d.o.o., Name of company
proizvodnja in trgovina
Skrajšan naziv Izoelektro d.o.o. Shortened name
Datum registracije 25. 01. 1999 Date of registration
Pravnoorganizacijska oblika Družba z omejeno odgovornostjo / Legal form
Limited liability company
Izjava o omejitvi odgovornosti: Dimenzije in teže izdelkov, ki Legal disclaimer statement: Dimensions and weight of products
so navedene v katalogu lahko odstopajo od dejanskih zaradi that are listed in the catalogue may differ from actual due to the
uporabe različnih materialov. Risbe v katalogu so simbolične. use of different materials. Drawings in catalogue are symbolic.
V primeru tiskarskih napak veljajo podatki s katerimi razpolaga In the case of printing errors the correct data is available by the
proizvajalec. manufacturer.
www.izoelektro.com