INTRODUCTION
The questionnaire is intended to assist auditors by illustrating the potential scope to
be covered in the auditing process. The questionnaire is not intended as a script for
the audit process and interviews, nor is it intended that each and every question
should be used. It suggests generic lines of enquiry and requires to be tailored down
to suit the terms of reference for the specific organisation, activity or facility to be
audited.
The questions are grouped such that they cover distinct topics applicable within the
context of each chapter with an element of prioritisation i.e. high level questions are
given first where possible. Within each group of questions covering a distinct topic,
there are a number of indented subsidiary questions as follows:
The main question
· A subsidiary question of the main question
- A subsidiary question of above.
If a main question is a dead end it does not automatically follow that
subsidiary questions are dead ends as well.
In preparing for auditing the specific topic and developing the structure for
conducting audit interviews with selected staff, the auditor should:
· Review the section of the questionnaire to obtain an overview of relevance
within the context of the topic audited.
· Select the areas most relevant to the person he is going to interview.
· Identify the most important questions to ask whilst realising the
appropriateness in the context of relative organisational level of the
interviewee.
· Convert generic questions to questions which are specific to the facility or
activity audited.
· Add other questions which are not given in the questionnaire .
'HSE' in questionnaires means 'Health, Safety and Environment', not just 'Safety':
the auditor should make sure that all 3 fields are adequately covered
The questionnaire is available in Word for Window format on IBMPC 5.25" or 3.25"
diskette.
Audit questions are aligned to EP95000 Volume 13. Volume 1 questions (HSE
Management System) are common to all audits.
1
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 2
Is a formal, authorised TWD procedure implemented?
· Which technical/safety standards are specified in the TWD procedure?
· Are there statutory requirements that apply to TWD?
· Are the documented TWD standards applied to:
mud programme design?
deviation programme design?
casing design?
expected maximum dog legs?
future well operations?
Are approved casing design calculation procedures used?
· Are complete casing design calculations carried out for all wells:
· Are formal checks carried out on the design conditions applied:
· Is there a formal procedure for approving casing design calculations?
Are kick calculations as specified in the Casing Design Manual, EP 922000?
· Are kick assumptions realistic in view of actual performance?
Are limit and leakoff tests as given in the Pressure Control Manual EP 891500?
Are approved cementation design calculation procedures used?
· Are standard, approved cementation design programmes used?
· Are cementation design procedures regularly reviewed and updated?
· Are standard, formal checks carried out in the cementation design on:
(bottom hole) pressures during cementations?
compatibility slurry/mud system?
critical sections for zonal isolation?
statutory requirements?
extended gas bearing intervals?
liner cementations?
high temperature wells?
high slurry gradients
platform loading
A formal policy on the cement bond logs for critical cementations?
Is formal approval required for cementation design calculations?
2
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 3
4.1.2 BOPs
Are casing rams used?
Are shear rams fitted?
· Is shearing force sufficient to cut pipe in use?
Are annular wellhead pressures monitored?
· Are gauges visible?
Is BOP configuration in accordance with EP 891500?
Are there hydraulically actuated valves on kill and choke line?
· Are manual valve handles securely installed?
Is good access provided to allow safe working on BOP system?
Is a BOP handling system installed?
Are there any screwed connections?
· Are there any sharp bends?
· Are hoses properly tied down?
Is BOP testing performed with low volume/high pressure pump?
· What is the BOP test frequency?
Is BOP bypassed during cementing operations?
Is BOP third party certification up to date (when was last overhaul)?
Is a maintenance register available?
· Are genuine parts being used?
Has any welding been done on BOP?
Are shear ram actuators guarded?
· Are functions clearly indicated?
· Is hydraulically actuated bypass valve installed? (for pipe shearing)
Are drilling staff competent w.r.t. use of the unit?
Is the unit fitted with adequate alarms?
· Is a low level fluid alarm fitted?
· Is a low pressure alarm fitted with repeater alarm on drillfloor?
3
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 4
Are BOP hydraulic operating lines well protected?
· Have they been tested to 3000 psi?
Are redundant functions plugged off and tested to 3000 psi?
Can bag type preventer closing pressure be regulated from the drill floor remote
panel?
At what frequency are BOP accumulator tests performed?
Has the minimum required bottle volume been determined and verified?
What is the pressure rating of the manifold?
· HP side?
· LP side?
Are all valves readily accessible?
Are 15k valves actuated?
Are all lines to and from manifold secured?
Are valves properly configured? (i.e. vertical or horizontal)
When drilling what are the open and closed positions of the valves?
Are standpipe and annular pressure gauges appropriately positioned?
· Is their function clearly indicated?
· Are they of the appropriate type?
· Do they show correct units?
Is there a hydraulic choke installed?
· Is the remote panel on drillfloor fully operational?
· When were chokes last inspected?
· Are they regularly flushed?
· Is a spare set of chokes and needles + tools to install available?
· Are chokes equipped with bleeder valves?
Is discharge (blooie) line from buffer manifold securely tied down?
Is the line to the atmospheric mud/gas separator appropriately sized?
4
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 5
Does unit conform to dimensions specified in EP 891500?
· Is it appropriately sized for potential well control problems?
What is length of "U" tube mud seal?
Are drawings of separator available?
Is a low range pressure gauge fitted at the top of the separator? Is it visible to the
operator?
Has impact of venting point on hazardous area classification and H 2S release been
considered?
4.1.6 Degasser
Is the unit working condition regularly checked?
· Is the unit regularly flushed?
· Is the unit regularly run?
when? ( for example as standard at bottomsup after a trip)
· Who operates the unit?
can operator explain how it functions?
Perform test run of unit
· Check operation of valves.
· Is vacuum gauge working?
· Check operation of float and the vacuum relief valve.
· Check linkage between relief valve and float bar.
Can inspection plug be accessed and removed?
To where is the gas discharge line routed?
Who is in charge of well control operations?
· What is the planned organisation in case of handling a kick? (who does what)
· Which shutin method is used?
· What are the close in procedures?
What is the procedure with regards to pre kick sheets?
· Who makes calculations?
who verifies?
5
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 6
· Where are copies kept?
how often are they updated?
· Does Company drilling supervisor receive a copy and check?
What shallow gas procedures are in place?
Where are slow circulation rates and pressures recorded?
What shift handover practices are in place?
Dimensions and configuration of ram positions in relation to the drillfloor?
Is the toolpusher on the drill floor when starting trips out of the hole?
Are all supervisory staff in possession of a valid well control certificates?
Do you receive any "inhouse" well control training?
Do you have a copy of the Group Well Control Manual EP 891500?
Are records of BOP tests available?
· Are tests witnessed by the Company drilling supervisor?
· Who determines the test pressures and on what basis?
· With what fluids are tests performed?
What are the procedures for monitoring the well path position?
· Do you keep a plot of the well path?
Do you have a copy of the drilling programme?
· Are changes in the drilling programme fully discussed, agreed by all parties and
documented?
· Are all potential well hazards fully discussed and highlighted in the drilling
programme?
Was a prespud meeting held with all relevant experts present?
· Did you have it prior spud?
6
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 7
Are kick and trip drills held?
· At what frequency?
at least once per week per shift?
· Are the drills documented?
· Are deficiencies experienced during drills resolved and information
disseminated?
Are BOP drills also held on each trip?
· Is this logged in the IADC report?
Is stripping equipment in place?
· Are key staff trained in stripping and volumetric pressure control?
have all drill crews taken part in a stripping exercise?
who keeps track of current stripping competency status?
Are gaseous emission points identified
· Does this include
mud gas separator vent?
degasser vent?
shale shakers?
active mud tanks?
prime mover engine exhaust?
well test / flare point?
emergency generator exhaust?
Has the MOSAG Oil Spill Exposure and Preparedness Index questionnaire been used
to obtain an indication of the Opco's capabilities in case of oil spills?
· Has the outcome of this spill response capability estimate resulted in follow up
actions?
Has a contingency plan been prepared to cover the environmental aspects of a blow
out
· Does the plan provide adequate focus on minimising pollution?
· Are all drilling personnel aware of blow out contingency activities relating to
environmental aspects?
· Is all required equipment according to the blow out contingency plan available?
are all drilling personnel trained in the use of this equipment?
7
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 8
Are up to date communication procedures available for the event of a blow out to
inform authorities and request assistance?
How is the interface between rig and the overall facility managed?
· Are daily ops. meetings held, who attends, are they minuted?
· What is the definition of work crossing installation boundaries?
How, on a day to day basis, does the deputy OIM perform his role with respect to
Simultaneous Drilling and Production operations?
· Does he have a job description?
Is there a Manual of Permitted Operations w.r.t. SDP operations?
"All work is hazardous unless the opposite is proven". How is this managed on a day
to day basis?
What are the formal handover procedures? How long is the handover period (crew
change arrangements)?
Is well work performed under the PTW system (if the automatic shut down system is
overridden)?
How often is the "hot line" tested? Is it reliable? Is the rig end always manned?
Is there a "T" card system?
· Is it checked daily?
by whom?
· What is the process for reconciling deficiencies?
· How are newcomers to the platform identified (induction training)?
Are platform and rig station bills amended to take account of the prevailing
circumstances?
8
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 9
How are maintenance activities coordinated?
Do offshore supervisors get copies of the minutes of onshore planning and co
ordination meetings?
· Do offshore supervisors take part in these meetings on their days off?
9
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 10
Which HAC system is used?
· Are hazardous areas fully mapped out?
in plan view?
in elevation?
Is hot work and the use of diesel engines in hazardous areas strictly controlled or
excluded?
Are diesel engines, if used on Zone 1 or 2 areas, fully protected and certified for this
application?
Are the hazardous araeas around the rig pointed out during site induction?
Is the air intake for electric motors inside hazardous Zone 2 areas taken from outside
the hazardous Zone 2 area?
· Physically check conditions for:
drawworks motors
top drive and/or rotary table drives?
mud pumps?
· Are air lines purged before DC motors can be restarted?
Is air for pressurised work cabins and accommodation taken from non hazardous
areas?
Is emergency lighting and power tested on routine basis
Is all switch gear adequately identified (missing name plates)?
Are cables trays run where they cannot be stood or sat upon?
· Are cables properly clipped to trays or other supports?
· Is cable identification adequate?
Are cable glands/terminations correct for the area classification?
Are cables run close to hot equipment?
Are power and signal cables segregated?
10
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 11
Are certified electricians on location?
Are all electrical motors suitable for hazardous areas (certified)?
Are all light fixture Zone 1 rated?
Are there asbuilt drawings?
· How often are they updated?
· Who authorises changes/modification?
Have there been any accidents with portable electrical apparatus?
Is the supply voltage more than 50 V AC or 120 V DC?
Are there procedures to minimise the risk of electrical shock?
· Do these include:
earthing all exposed metal parts (Class I apparatus)?
monitoring the integrity of the earth path?
having an allinsulated outer enclosure (Class IIA apparatus)?
double insulation to isolate exposed unearthed metal (Class IIB)?
using a reduced voltage to supply apparatus?
sensitive earthleakage protection to limit the duration of the shock?
Is the apparatus always protected against overload and short circuit?
Are there any indications that flexible cables have been damaged?
Are sensitive earth leakage protection (ELCBs or RCDs) methods used?
Are the ELCBs equipped with test pushbuttons to prove the integrity?
Is there a register for portable electrical equipment?
· Does the register indicate when each item should be maintained?
· Is all portable equipment marked to indicate when maintenance is due?
· Is the inspection and maintenance carried out by a competent person?
Walking/working surfaces
Entrance and exit doors operate freely, exits lead to a safe area?
· Glass portion of door(s) is shatter resistant material?
11
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 12
Ear protection and a sign requiring its use located near the entrance?
Passageways are clear, not slippery?
Obstacles identified by bright paint?
Handrails/walkways around equipment are sturdy and sufficient?
Flammable liquids and gases are not stored in building?
Equipment
Panel boards have master shutdown switches identified?
· Function of other switches is adequately identified?
· Rear panels are in place?
no exposed wiring?
Floor by switchgear has rubber/wood mat?
· Mat is not a tripping hazard?
Relief valves (regular relief also) are adequately piped away?
· To area away from personnel
· To area away from potential ignition sources?
Guards installed over moving parts; e.g. fans, pump couplings?
Spark plug wiring not cracked or frayed?
Electrical apparatus
Check:
· Explosionproof fixtures in compressor room?
· Vapour covers and guards installed over lights?
Is illumination sufficient?
Any signs of exposed wires or broken conduit on light fittings?
Transformer stations
Is there limited access to the area?
· Is it fenced?
· Do all entrances have 'HighVoltage' signs posted?
12
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 13
Where are detection systems located?
· UV sensors?
· smoke detectors?
Is there a central panel indicating alarm location?
Is there a deluge system?
· If so, how is it activated:
automatic
manually activated?
When are fire detectors tested?
Where are gas detectors situated?
Is there an established response procedure in case of alarm?
· Do staff understand the readings given on the gas detector gauges?
Are portable gas detectors available?
· Who is qualified to use them?
How often are gas detectors calibrated and tested?
Is there copy of "Guidelines for Detection & Control of H 2S in Drilling Operations",
EP53738 available?
Are there written emergency procedures?
All personnel on site trained and exercised (if appropriate)?
Where are gas detectors situated?
· Fixed and portable detectors calibrated and tested at an appropriate frequency?
Detectors and alarms available and in working order?
· Are performance reports made and followed up?
13
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 14
B.A. sets available for all personnel?
Is there a cascade system in place?
· Are crew rehearsed and familiar with its use?
· Escape capability part of cascade mask?
Bug blowers on standby?
Wind direction indicator i.e. flags visible from all areas on the location?
Warning flags?
Buddy system in place?
Are the fire and general alarms tested regularly?
· Do all personnel know what these alarms sound like?
· Have all personnel been given a full briefing on alarm response?
· Can these alarms be heard throughout the location?
including service contractor cabins and accommodation?
Are muster points clearly marked and identified?
How are personnel accounted for at muster points?
· Is there a central control against POB?
What ESD controls are available?
· Do drill floor staff know all ESD functions?
what they do
where they are?
Are all power sources within hazardous Zone 2 areas included?
When were ESD functions tested?
14
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 15
· Are tests documented?
What crownblock protection device is installed?
· How and when is it tested?
Do all supervisory staff know how to actuate the ESD function?
· Do they know what is actually shutdown?
Are there written description of the ESD system available?
· How about the ESD for DC logging generator and cement unit?
Are all alarms known to staff on the rig?
Is response to alarms regularly practised?
If an alarm is isolated is there a procedure for isolation?
What is the vessels survival draught?
· What are the requirements of going to this draught
· Can it be reached without dumping material?
if material needs to be dumped what is the dumping priority?
Is the ballast control room continuously manned?
How often are stability calculations made?
· Who checks them?
What are the storm monitoring procedures?
What are the standing instructions with regard to mooring system failure?
How is liaison between the ballast control room operative and driller?
15
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 16
Are rig specifications fully documented?
· Do these specifications agree with the contract?
· If there are variations, are they agreed and documented?
· Are the rig specifications compatible with the proposed drilling operations?
Have there been any significant modifications to the rig equipment?
· Are these modifications carried out under full engineering control?
Do asbuilt drawings exist, how are they updated?
Environment
Has a drilling EA been prepared prior to drilling?
Has an Environmental Management Plan (EMP) been prepared to cover all drilling
related environmental aspects?
Have all environmental aspects resulting from the EA been included in the HSE
Case?
Is a policy of minimum land use for drilling locations applied?
Is access to the location routed such as to cause least environmental impact?
Are measures in place to avoid / control erosion?
Is slim hole drilling considered as an option to minimise environmental impact?
Are land use issues discussed with the land owners / local authorities?
Is a plan in place to restore the drill site to its former use and status after
abandonment?
Is dredging of access slots to drill locations minimised?
· Is dredge slurry being disposed of in accordance with Group guidelines and local
legislation?
Is the drilling location offshore selected to cause minimum impact to the
environment? (e.g. coral and sea grass beds.
16
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 17
Community aspects
Have consultations been held with the local community to obtain their views with
regard to the drilling activity?
Are local community personnel involved or employed in the activity?
Is the impact of drilling activity such as emissions and noise kept to a minimum?
Is a claim system in place to pay for incidental damage?
Are local fishermen informed about possible disturbance to their activities during the
drilling activity?
How are pumps electrically isolated during repairs?
· Can the DC motors of the mud pumps be isolated locally?
· Are isolation procedures included in PTW system?
How are the suction dampeners charged?
· What is the HP pulsation dampener precharge?
Are pressure relief lines routed to mud pits?
· Do they slope correctly?
Does high pressure manifold and piping have screwed connections?
Is mud pump motor blower air taken from outside hazardous zone 2?
Are lifting devices installed to facilitate safe working during pump repairs?
Are HP jumper hoses properly secured?
Are power cables to mud pumps properly protected?
Are pressure gauges functional?
Is HP piping NDT tested as part of a systematic procedure?
What is the tank entry procedure?
How is paddle isolation effected and verified?
17
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 18
How are repairs to mast or structure controlled?
· What are the procedures under the preventive maintenance system for
inspecting major components of the rig and its equipment?
are manufacturers consulted?
· Are NDT records available?
· Are welders suitably coded?
Are there inspection certificates available for the mast covering the last 5 years?
· Are third party inspection records (NDT in disassembled condition) available for:
drawworks
travelling block
dead line anchor
rotary table
swivel
crown block
top drive
· Check for PMS, anticollision devices and pipe racking system.
When was mast raising sling last inspected?
Is drilling line in good condition?
· Is it subjected to a documented slip and cut programme?
Is there a system of weekly inspections of derrick equipment?
· Is this carried out by competent staff?
Is an independent battery backup for Elmagco brake installed?
Is there an alarm to alert the driller should power to the Elmagco brake be
lost?
Are kelly cocks with connections for DP and DC's available on floor complete with
keys?
· Are they included in the BOP pressure tests?
· Is a spare kelly cock available?
Are tong backup lines properly connected to proper backup posts and not to mast?
18
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 19
· Are tong backup and suspension lines entered in sling register?
Are all lifting tools inspected and colour coded?
In what condition are slips and elevators?
· At what frequency are they inspected?
Has any welding taken place on elevators or other lifting devices?
Is a casing washdown hose available?
Are controls labelled and easily accessible?
Does the driller (and A/D) know all alarms
· Does this include:
console air low pressure?
brake water failure?
brake overheating?
auxiliary brake power failure?
low accumulator fluid level?
low accumulator manifold pressure?
Are there emergency stop functions for all key functions:
· Does this include:
general ESD for electrical power, DC & AC?
drawworks
brakes
RT and topdrive
Iron Roughneck
Are gas detector alarms, audible/visible?
Are mud tank level and flowshow alarms tested and working?
What is the testing frequency for all of the above alarm and ESD devices?
4.4.8 Winches
Are winches in good overall condition?
Are all winches marked with SWL?
Is a winch suitable for manriding available?
· Is manriding controlled by the PTW system?
19
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 20
Are exhaust silencers fitted?
Is proper access provided?
Are pressure relief valves certified? With what frequency?
· At what pressure are they set?
· Is documentation available?
Have the tanks been tested?
· To what pressure?
· At what pressure is air delivered?
20
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 21
Are the extinguishers mounted off the floor?
· Are they in their designated place?
· No obvious physical damage?
Are the units sealed and tagged to indicate it is checked on a regular schedule?
· Any units overdue for hydrostatic test?
Are there written records available of annual (minimum) inspection?
· Is the manufacturers inspection procedure available in the field?
Are fire extinguishers properly colour coded?
Are end caps plastic or metal?
Is Halon being used as an extinguisher agent?
Any obvious signs of physical damage?
Hoses are not rotten or severely cracked?
Hose reels and nozzles operate freely, remote reels tagged and sealed.
Are valves pinned and sealed in the operating position?
Sealed and tagged to indicate it is being checked on a fixed schedule?
Do Nitrogen cylinder gauges indicate 'full' pressure?
Are the units sealed and tagged to indicate it is checked on a regular schedule?
· Any units overdue for hydrostatic test?
Are there written records available of annual (minimum) inspection?
· Is the manufacturers inspection procedure available in the field?
Hoses
Any signs of cuts or abrasions, stripped threads?
21
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 22
Connected to standpipe, spanner wrench available?
Nozzle connected to hose and operable?
Hose length sufficient for probable area of use?
Tested periodically for pressure reliability, leaks, etc.?
Hose boxes/reels/standpipe
Door/reel operates freely, not blocked?
Easily identified; e.g. painted red, stencilled 'Fire Hose'?
Valve operates freely, wrench (if applicable) on valve?
Equipment is free of insect nests?
Inspected on a weekly basis by qualified personnel for ease of starting, pressure,
suction and fuel?
Pump has starting/inspection procedure labelled on it?
All assigned personnel are familiar with pump operation?
Separate fuel supply sufficient for several hours operation?
Sufficient suction and discharge hose?
Correct coupling and nozzles for hoses?
Crossovers (if necessary) for standpipes in area of intended use?
Foam
Inductor tube and foam located with hoses?
Foam nozzle(s) stored in an accessible location?
Foam checked annually for chemical makeup?
Is foam concentrate in good condition?
Foam suitable to those liquids encountered?
22
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 23
Is the plan explained fully as part of newcomer induction process?
How frequently are full evacuation drills held?
· Are muster plans and head count procedures part of evacuation drills?
· Are all drills recorded and noted deficiencies rectified?
Are escape routes illuminated and clearly marked, also suitable for smoke conditions?
When were lifeboats last lowered into the water (if applicable)?
Have coxwains been trained in the use of the lifeboats and their equipment?
· Have coxwains all lowered a lifeboat into the water during a recent
drill/exercise?
· Are coxwains also part of firefighting teams, search & rescue parties?
if so, are there sufficient coxwains to man the lifeboats?
Have all personnel on board attended a valid offshore survival course?
Can adequate firstaid be provided for every worker within four minutes?
Have firstaiders/medic had appropriate initial and refresher training?
· What is medic's training, medical qualifications and background experience?
are there any language difficulties?
to whom does medic report?
· Are firstaiders/medic capable of conducting CPR?
Is the medic based permanently at the rigsite?
· Are there adequate provisions for travelling between rigs and camp sites?
Are their other qualified firstaiders on site?
· Are firstaiders equipped with appropriate firstaid boxes/kits?
Are standards of hygiene in the clinic high?
Are health and hygiene inspections made around rig camp sites and
recommendations followed up?
Who accompanies medic on his inspections
What is being done to combat the main risks to employees health?
Are all firstaid treatments reported to the person in charge?
· Is a medical log kept?
who gets the information?
23
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 24
Is the provision of medical supplies sufficient?
· Are narcotic drugs available?
if so how are they safeguarded?
Can a casualty be transported to a fully equipped hospital within four hours of
injury?
Is a complete set of MSDS sheets available and is the clinic equipped to treat cases of
chemical contamination or poisoning?
How often are medical inspections by a doctor performed?
Is the medic playing an active role during safety meetings?
What is the role of the medic during drills?
Are there written procedures for food hygiene and catering?
· Are food handlers trained and well aware of measures needed to prevent food
borne illnesses?
· Are catering inspections carried out?
recorded?
actions closed out?
Is there a written procedure in use for potable water testing?
· Is potable water regularly tested?
are results recorded?
Is auto start installed?
What is the test frequency?
Is their a separate distribution board?
Are key safety systems connected?
24
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 25
Is there a PTW system?
· Do the following work permits exist and how are they used?
Hot work
Electrical
Use of explosives
Work at height above 2m.
Manriding using rig manriding winches only
Entry to vessels
Electrical isolation
Mechanical isolation
Valve lock out
Radiation permit (how covered)
· Are there general definitions as to which permits are necessary when?
Does the PTW system cover all aspects of hazardous work?
· Are the requirements known to all the work force & supervisors?
Is there any system of review of the use of the PTW system?
· Who else in the organisation sees copies of all permits issued?
Is there a permit queue in the morning and how handled?
Who is allowed to sign what sort of permit?
· Are they officially nominated by name or job?
· Are they examined before being authorised?
How is a permit adapted if scope of job changes in the middle?
Where are permits stored?
· How long?
· When in use, where are they displayed?
How does one establish when a job is finished?
Who does what in the permit administration?
· Who fills in the bulk of the precautions to be taken?
· Who physically checks that precautions have been taken before work?
· Who personally briefs the men doing the job before work starts?
25
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 26
what briefing does he give a service contractor new to the site?
· Does he check their knowledge of Company regulations beforehand?
How is a permit arranged in an emergency, such as during the night?
Is PTW subject site of site induction and signatory training?
Safety hats
Are they being worn by appropriate personnel?
· Any signs of deficiencies?
cracks
torn suspension
defective clips
other evidence of rough treatment?
· Any evidence of plastic hats having been field modified by:
painting
bolts and nuts installed to hold ear muffs?
Electrical protection hat provided for the electrician?
Safety boots
Are they being worn by appropriate personnel?
By observation note general condition of shoe?
Proper type available for the jobs involved?
Stored in easy to locate areas?
Kept clean, not scratched, cracked or pitted?
Cleaning equipment available?
Strap/snaps are secure, not worn?
Safety belts
Available to be used when working at heights?
Stored out of the weather, straps not rotten?
All rivets in place, 'D' rings and hooks not rusty or bent?
26
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 27
Safety line (1/2" nylon minimum) stored with belt, lines are spliced not tied?
Hearing protection
Being worn when needed by appropriate personnel?
Located in areas where they are needed?
Sufficient quantity and kept dry and clean?
· Involving all crew members?
Are toolbox meetings held before hazardous work begins?
Is a toolbox talk used to precede non routine or unusual work?
Is there an active system of Job Safety Analysis (JSA)?
· Are JSA's used for toolbox meetings and prejob briefings?
What system is used to report unsafe acts or conditions?
· Is there a weekly/monthly target set for returns handed in?
· Are trends analysed and published?
are returns reviewed daily?
Are worthy reports or suggestions included in weekly crew safety/HSE meetings?
· What follow up is evident?
Is there a central record kept of deficiencies noted from all possible sources?
· Who is responsible for close out?
Is the register reviewed at management level
· How frequently?
Are serious, high potential deficiencies circulated promptly to other rigs and areas?
At which meetings are deficiencies discussed and close out targets set?
27
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 28
4.6.6 Maintenance
What are the systems used for controlling and recording maintenance?
Are complete weekly / monthly status reports generated?
· Are safety critical items of equipment flagged?
· Is the backlog report seen and acted upon promptly?
is there a backlog of maintenance on any listed safety critical items?
Is there a formal system for initiating engineering/ electrical changes?
Is there a commissioning and acceptance procedure for changed equipment?
· Is changed equipment properly tested and certified?
Are updated asbuilt drawings available?
· If so, where?
4.6.8 Housekeeping
Are housekeeping inspections part of the weekly inspection routine?
· Do inspection records show deficiencies?
· Who is responsible for verifying that deficiencies are corrected?
Are there signs of poor housekeeping?
· Are emergency exit and escape signs kept clean and legible?
· Are safety signs kept clean?
· Is the chemical sack store area kept neat and tidy?
· Are chemical spills cleaned up promptly?
· Is soiled clothing properly segregated from clean clothing?
· Are mess tables and floors kept clean?
· Are there signs of insect or rodent infestation?
Do all work and accommodation areas have a person assigned responsible for
housekeeping?
What legislation exists concerning waste disposal?
· If applicable, are disposal permits obtained?
Is there a quantified inventory kept of wastes?
28
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 29
Is there a waste disposal plan given in the HSE plan?
Who is responsible for waste management?
Is waste segregated?
· By type?
· By hazard potential?
· By pollution potential?
Is waste oil and other used oil properly manifested for subsequent transport?
Is there equipment on site for total containment of oil based mud?
· What is done with OBM cuttings / solids?
is OBM fully recycled?
what is done with waste OBM?
Is an oil spill response plan in place?
· Is equipment available to cope with minor oil spills?
Is there a blowout contingency plan prepared to minimise pollution?
Is oil separated from water/mud?
· For separate disposal
· For reuse?
Are location drains of sufficient capacity to contain major drilling fluid or fuel spills?
What activities are in place to prevent / minimise waste?
· What is done with kitchen / food remains?
· What is done with chemical wastes?
· Is a sewage treatment facility being used?
For marine facilities, are MARPOL requirements fully complied with?
Are chemicals selected based on minimum toxicity to the environment?
· Is information on environmental toxicity of chemicals used available?
Are chrome based chemicals being used?
Is a complete inventory of chemicals including information on consumption and losses
kept?
29
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 30
Is a purchase back agreement in place with suppliers for unused / excess chemicals?
Are chemicals packed and stored to ensure minimum loss from damage, weather
conditions and handling?
Is the expiry date of chemicals checked?
Is the location design providing for total containment of chemicals stored and used?
30
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 31
4.7.1 Noise
Has the rig and accommodation area been surveyed for noise levels?
Are areas with ear defender signs in locations with noise at 85 dB(A) or more?
· Is the use of hearing protection in high noise areas mandatory?
Is there evidence of noise reduction plans?
· Any examples?
Are audiometry tests and records kept for personnel working in high noise
environments?
· What form of scrutiny of such records exists?
4.7.2 Chemicals
Are all chemicals on site listed on MSDS or similar data sheets?
· Does the medic keep this list?
is it up to date?
· Are service contractor chemicals with laboratory chemicals included in the
MSDS
Are dangerous chemicals identified and segregated?
Are appropriate dust masks used when handling chemical powders?
Is mixing and handling of dangerous chemicals supervised by senior, experienced
staff?
Is chemical data available in the mixing area?
4.7.3 Lighting
Is lighting adequate for all work and accommodation day and night?
Do emergency lighting units illuminate escape routes?
Are portable lighting units available for work in unusual locations?
Are explosion proof hand lamps available in all accommodation and strategic work
areas?
31
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 32
4.7.4 Accommodation
Doors operate freely, glass portion is shatter resistant material?
Exits are of sufficient quantity, identified and lead to a safe passageway?
· Any exits locked or blocked.
Do two storey buildings have an upstairs exit?
Fire doors installed in corridors?
· Stairways?
No obstructions and well illuminated?
Fire extinguisher every 150 linear feet of hallway?
Handrails are secure, no sharp edges and easy to negotiate?
Emergency (battery powered) lights of a sufficient amount?
· Spaced to best advantage?
Sleeping accommodation
Ladders provided to reach upper bunks?
No evidence of smoking in bed?
No exposed electrical wiring?
Fire extinguisher nearby (inside room when occupied by more than 4 persons)?
Adequate ventilation?
Smoke and fire detectors installed?
Gas stove in adequate working order?
· Use of odourised gas
· Pilots and burners work
· Personnel know location (away from stove) of cutoff valve?
Electrical equipment in good working condition?
32
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 33
· No exposed wires?
· Earthed?
· Personnel know location of circuit breaker switch?
Area surrounding stove is grease free?
· Vents are grease free?
Sharp implements are properly stored?
Adequate firefighting equipment available?
· CO2 or dry chemical extinguishers?
· Fire blanket available?
Floor drain available for effective washing down?
Relief valve piped so as not to injure personnel?
Uses odourised gas?
Units are grounded and no exposed wires?
Cutoff valve located away from unit?
· Location is known?
Pressure containers subject to heat rupture are not stored near these appliances?
Showers
Safety glass or curtain used for shower door?
Floor not slippery?
No broken glasses, mirrors or sharp edges in room?
Wall heaters have no burn marks on them?
Electric switches and receptacles are located away from the shower area?
Miscellaneous
Walkin coolerfreezer can be opened from the inside?
All electrical appliances (coffee pots, icemakers, freezers, etc.) in good working
condition?
· Any signs of broken insulation (especially where cord enters appliance)?
· Are all properly earthed?
33
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 34
Circuit breaker switches are easily identified, have no exposed wires and no sign of
arcing near box?
Flammables/explosives are not stored inside living quarters?
Building appears to be kept in a clean and sanitary manner?
Are eye wash and deluge facilities available in strategic chemical handling areas?
· Is water supply clean and at an acceptable temperature?
· Are the eye wash stations inspected daily/weekly?
Are deluge facilities tested daily?
Are laboratory facilities equipped with eye wash/deluge capability?
Where are radioactive sources stored and used on location?
· Is the storage container adequately sign posted and barriered
has the radiation level at the barrier been verified?
· Has access above and below the storage container been included in the barrier
system?
Is movement of radioactive sources conducted under PTW?
Is a register kept on site?
· By whom?
· Is it complete?
34
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 35
4.8.1 Land
Are responsibilities for management of road safety defined for:
· Operating vehicles?
· Driver training?
· Performance monitoring (both Company and Contractor)?
Is sufficient time allocated/available for the completion of these responsibilities?
Does the vehicle selection process involve Well Operations Dept?
Are design and performance features verified against critical specifications?
· Does this include?
4WD;
seat belts;
roll over protection;
speed limits;
tyre standards;
defect reporting;
accident reporting;
maintenance schedules;
Is a driver monitoring system (e.g. VAPS) installed in vehicles.
Is prequalification made of all contractor and subcontractor equipment, personnel
and safety management?
Are adequate standards detailed in tender documents and contracts?
· Does this include:
driver qualification and experience?
driver training?
vehicle operating and maintenance procedures
35
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 36
Do vehicle operating procedures define maximum working hours, rest stops and work
cycles?
Do contracts specify conditions for subcontracting?
Are authorised drivers, both Company and contractor, verified as meeting company
standards?
Is defensive driving training given?
· If so what proportion of drivers have been trained?
Are drivers supervised while loading/offloading on location?
What liaison takes place between vehicle drivers and Contractor crane/forklift
drivers?
Are drivers sourced from a 'pool' system or can they be selected?
Who supervises the loading of vehicles at the supply base?
· Have supply base supervisors adequate:
training
experience
knowledge
Is the supply base subjected to regular inspection?
What controls are there on vehicle movements on / off the location?
· Are location access points clearly identified?
· Is there a parking or waiting area provided?
Is it clear where drivers report to upon arrival and prior to departure?
Is the person in charge of materials handling from vehicles identified?
· Is he qualified in the use of:
lifting equipment
cranes / forklift trucks?
· Has he been briefed on the restrictions in Hazardous Zones?
Are all drivers in possession of valid driving licenses for the categories of vehicles
driven?
Are crew change vehicles and the designated ambulance in satisfactory condition?
· Does the stretcher fit into the ambulance?
36
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 37
How frequently are rig site vehicles inspected by a competent member of staff?
What other controls are in place?
· Is a drink drive policy enforced?
· Are seat belts required?
is their use mandatory?
· Are speed restrictions enforced?
· Is journey management used as mandatory routine?
4.8.2 Marine
Are supply vessels generally fit for purpose?
Are suitable moorings available for supply vessels?
Who is in charge of supply vessel operations whilst alongside the rig or platform?
Where is the fast rescue boat kept?
· When was it last inspected and taken into the water?
· Who is trained to use the fast rescue boat?
Is there a standby boat?
· Does this vessel participate in MOB drills
Is there a 24 hr. watch kept for approaching vessels?
Are materials arriving on the rig preslung?
· How is preslinging controlled?
Is third party lifting gear also subject to inspection and certification?
Are rig cranes fitted with adequate lighting to illuminate supply boat decks?
Does the crane have a warning horn?
Is there radio contact between crane driver and the supply boat deck crew?
Does the crane driver have good visibility over supply boat decks?
Are roustabouts trained in banksmanship?
Who supervises boat loading and unloading to and from the rig?
Is bulk transfer of chemicals, cement, fuel and water satisfactory?
37
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 38
4.8.3 Air
Are safety briefings given before each flight?
Are flight manifests complete for all passengers and cargo?
Has the Medevac plan been tested with the aircraft contractor?
· Does the stretcher fit into the aircraft?
has this been rehearsed?
Are night landing lights available in the case of an airstrip?
Is there a qualified HLO (if appropriate) ?
Are firefighting facilities available at the aircraft landing area?
· Who is trained to use the firefighting equipment?
are fire monitors manned during landing / take off?
do fire monitor attendants wear full fire suits?
Is aircraft fuel, if stored in drums, kept separate from any other fuels?
· Are there drains / gutters to cater for fuel spillage?
are these drains separated from process and domestic drain systems?
Is crane included in PMS?
· Are daily checks performed?
Is an operational load indicator in place?
· Is there an overload alarm?
· Can above devices be bypassed?
· Is all lifting gear marked with the SWL?
any lifting gear being used which is not registered and colour coded?
Is reversing alarm fitted and working?
Is hoisting wire in good shape?
· Is it subjected to a planned slipping/replacing schedule?
Are trained, nominated crane drivers assigned?
Is it suitable for hazardous zone usage?
Is there a register kept updated of lifting gear, including slings and pad eyes?
· Are all lifting appliances, including slings, colour coded?
38
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 39
· How is third party lifting gear checked and certified?
who keeps records of third party inspection?
Is forklift included in PMS?
Is a hazard warning light and reversing alarm fitted?
Is driving restricted to trained nominated persons?
Are attachments properly engineered?
Is it suitable for hazardous zone usage?
39
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 40
Work schedule of site staff?
How often do managers visit the site?
· Are visits documented?
Is the contract available with engineer?
· Is he familiar with HSE clauses?
· Is his training in accordance with the contract?
· Does he take part in full range of safety meetings?
· Is he familiar with chemicals used?
· Was engineer given an induction upon arrival?
by whom?
Is MSDS appropriately posted and available with medic?
· Where is the master MSDS kept, by whom?
Do Drilling Contractor and Company Rep. include facilities in inspection schedule?
Is an RCCB installed and is the unit earthed?
Is chemical storage area well organised?
· Are hazardous chemicals segregated?
· Is there good access for the forklift?
do awkward or heavy loads need to be manhandled into position?
· Are storage containers suitable?
· Are contents of sacks and drums readily identifiable?
Is there an emergency shower close to the mixing hopper?
40
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 41
· Is it simply activated?
Are eye wash facilities available?
· Is water a reasonable temperature?
Are there adequate safety signs?
Is appropriate PPE readily available?
Who supervises operations with caustic soda?
Are mud tanks etc. well maintained to prevent loss of product?
· Are valves and flanges regularly checked for leaks?
Work schedule of site staff?
How often does manager visit?
· Are visits documented?
Is the contract available with engineer?
· Is he familiar with HSE clauses?
· Is his training in accordance with the contract?
· Does he take part in full range of safety meetings?
· Was engineer given an induction when he arrived?
by whom?
Is there a chemicals inventory?
Are MSDS appropriately posted and available with medic?
Do Drilling Contractor and Company Rep. include facilities in inspection schedule?
Is an RCCB installed and is the unit earthed?
Is a register of radioactive sources kept on site?
· Is it updated following source movements?
What is the rate of gamma and neutron emissions from the radioactive store?
· How often are they measured?
· If emissions are above 2.5 micro Sieverts/hr, what precautions are being taken?
Are primary and secondary explosives segregated?
· Are explosives and radioactive sources stored in different areas?
Are effective radio silence procedures in place?
41
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 42
· If not, is radio safe perforating equipment in use?
Are operations using radioactive sources and explosives performed under PTW?
If explosives container is jettisonable:
· Who decides when this should be done
· Who is tasked with effecting the jettison?
Work schedule of site staff?
How often does manager visit?
· Are visits documented?
Is the contract available with engineer?
· Is he familiar with HSE clauses?
· Is his training in accordance with the contract?
· Does he take part in full range of safety meetings?
· Is he familiar with chemicals used?
· Was engineer given an induction when he arrived?
by whom?
Is MSDS appropriately posted and available with medic?
Do Drilling Contractor and Company Rep. include facilities in inspection schedule?
Who supplies the cementing programme?
Cement unit
Is discharge manifold of integral construction?
Is a pressure limiting device installed and tested prior to each job?
· Do pressure relief valves need resetting after operating?
where is relieved fluid discharged?
· Are shear discs installed in pump fluid ends?
· Are lines properly constructed and tied down?
· Do relief/limiting devices protect downstream pipework (are they set
appropriately)?
Is the unit manifolded to kill line?
· Is a nonreturn valve installed?
Are diesel engines suitable for hazardous zone use?
42
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 43
Is adequate PPE and recovery equipment available close by:
· Does this include:
shower
eye bath
breathing apparatus
goggles
gloves
aprons
dust masks
Are telecommunications fit for purpose (audibility)?
Are emissions from radioactive densometer regularly checked?
· Are they within permitted limits?
Are plug containers, circulating heads and pumping iron all certified?
Work schedule of site staff?
How often does manager visit?
· Are visits documented?
Is the contract available with engineer?
· Is he familiar with HSE clauses?
· Is his training in accordance with the contract?
· Does he take part in full range of safety meetings?
· Was engineer given an induction when he arrived?
by whom?
Is there a chemicals inventory?
Are MSDS appropriately posted and available with medic?
Do Drilling Contractor and Company Rep. include facilities in inspection schedule?
Is carbide used, where is it stored?
Is an RCCB installed and is the unit earthed?
Can engineer describe what is expected of him:
· During drilling
· During tripping
· During logging
43
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Page 44
· When on bottom after tripping
· Involvement in BOP drills?
What signs indicate a reduction in hydrostatic overbalance?
Have any BOP drills been held recently? What do you monitor?
What communication equipment is available?
Is engineer kept informed of:
· Changes in parameters?
· Tank level changes due to mud treatment?
Is there a sample catcher?
Does engineer have to leave the cabin during drilling or tripping to perform his job?
· Is there full 24 hour coverage?
Where are following equipment mounted:
· Mudpit level sensors?
· Gas level sensors mounted?
· When were they last calibrated?
are records of calibration kept?
Is the unit or its pressurisation air source positioned in a Zone 2 area?
· Check working of pressurisation system
Which services are integrated through which contract holder?
· Is there a site Integrated Services Contractor (ISC) coordinator
does the ISC coordinator have a job description?
Is there a common HSE plan and objectives?
· Do they have compatible HSE policies?
Do all integrated services personnel on site use the same safety systems?
44
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Attachment 1 Page 1
There are several categories of staff and rig crew to interview on each rig site and
each category will provide audit input to specific topics related to his/her job
description and responsibilities. Listed below are staff and crew with issues which
should be addressed during the interview, not necessarily all topics for each
individual in one interview; possibly as follow up from previous interviews.
Interviews are not necessarily listed in sequence of interview priority, as this will
frequently depend on availability of the interviewee and the priority of ongoing
operations.
There is common information which should be collected from all individuals
interviewed, which if recorded can greatly assist in forming an overall picture of
staffing levels, competency, HSE training and experience levels. A sample interview
cover page is attached as Appendix 1.
Staff / Crew category
Interview topic & issues
OM / TD / MD, Company Hd. of Drilling, Co. Rig Superintendent
TOR, current concerns, scope of work contracts, HSE plan, HSE plan review, rig site
visits, company HSE and daughter policies, drilling engineering HSE case.
Rig Manager
Organigrams, training and audit records, deficiency, audit / inspection programme,
audit & incident report follow up, meetings, rig visits, incentive schemes, HSE plan
review, rig specific HSE case.
OIM / Captain / rig supt.
PIC, sling register, explosives register, radioactive substance register, PTW records,
PTW quality control, deficiency register, third party inspection, classification and
certification records, drill reports, emergency response plans, fast rescue boat,
lifeboat drills, MODU code exceptions, company policies posted, alerts, DENs and
other notices received, application of the HSE case, environmental issues, waste mgt.
and pollution control.
1
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Attachment 1 Page 2
Toolpusher
PTW, BOP & well control certification, well control competency, derrick & lifting
equipment inspection, shift & tour handover, top drive PMS, application of the HSE
case hazard register, pre shift toolbox talks.
Snr. Mechanic and Electrician
PMS, PTW, crane maintenance, gas detection, alarms, ESD systems, ESD tests, P
tank and compressed air vessel tests/certification, relief valves, emergency generator
operation.
Drillers
Rig floor tools, air winches, man riding winches, PTW, ESD, alarms, drills, BOP
drills, shut in procedure, Elmagco brake, crew change and handover, emergency
disconnect, top drive, accumulator unit, SPM, BPM, degasser, mud gas separator,
instrumentation, shift instructions, toolbox talks.
Assistant driller
Mud mixing, pump maintenance, PTW, BOP operation, well control certification,
tank cleaning, derrick inspection, degasser operation.
Derrickman
Mud pump repair, chemical mixing supervision, chemical storage area ownership,
tank cleaning, PTW, derrick inspection, manriding winch, safety harness, Geronimo
line, BOP flange up/down, use of cascade system.
Floorman
Air winches, man riding winches, PPE, language problems, escape B.A.s, cascade
system, BOP drills, STOP/UAA, rig floor housekeeping, lifting equipment colour
coding, near miss incidents.
Safety officer
Training records, HSE live systems, STOP/UAA, meetings & minutes, dissemination
of information, MSDS, PTW, drills, HSE statistics, rig induction process, HLO, fire
crew training, H2S, MOB drills, breathing apparatus, advice & support received from
HSE advisor(s).
2
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Attachment 1 Page 3
Medic
Records kept, Medevac, MSDS, firstaid training, stretcher drills, occupational health
statistics, drills, dangerous drugs, potable water quality control, accommodation
inspections, other duties POB etc.
Radio operator
Drill duty, standby vessel, communication with other radio watch stations, emergency
contact numbers/frequencies, aircraft procedures, radio silence, crew change
monitoring.
HLO
Qualifications, fire team training, pre flight briefings, crane control, other duties.
Deck foreman
Deck crew duties, crane supervision, lifting equipment, boat off loading / backloading,
chemical handling & mixing, service contractor equipment, heavy lifts.
Crane driver
Lifting slings, third party equipment, roustabout supervision, crane maintenance and
inspection.
Roustabout
Supervision, PPE, banksman training, firstaid, materials handling (toxic/non toxic,
flammable, radioactive etc.).
Control/stability operator
24 hr manning, deck loads & limitations, ballast control, emergency response, alarms,
ESD, PTW control, emergency power.
Service contractors
HSE common plan, integration with rig HSE systems, drills, induction, radio silence,
radioactive source register, PTW, explosives, third party lifting gear, integrated
services coordinator, contract availability, OBM containment & spillage control,
MSDS for cement and completion fluids, use of PPE, laboratory chemicals.
Integrated Services Coordinator
Job description, coordination meetings, integrated HSE policies, combined
incident reporting system and safety systems, internal inspection and audit,
common PTW system, direct communication with Co. and drilling contractor
senior supervision.
Camp boss
Housekeeping, hygiene, health certificates, insect / rodent infestation,
3
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Attachment 1 Page 4
dissemination of information, fresh food supply, food storage, laundry, toilet & shower
room cleanliness.
Welder
PTW, hot work procedures, radio silence, hazardous area control, PPE.
Company DSV
Contracts, well programme, BOP pressure test records, HSE plan, rig inspection
records, meetings attended, handover, incident / near miss reports, audit followup,
PIC, drill evaluation, PTW control.
Visitors & new employees
Induction, ID tag, POB 'T' card system, use of PPE, breathing / smoke hoods / life
vests, alarms, smoking policy, "green hats", nogo areas, sick bay location.
Drivers
Competency, defensive driving training, license legislation, speed restrictions,
seat belt policy, night driving rules, roll bars, location entry / exit control, ambulance
driver, vehicle checks, journey management, crew change procedures
Standby boat
Oil spill equipment and trained operators, MOB drills, firefighting equipment,
radar surveillance, radio watch, crew changes, cargo and materials handling, fast
rescue boat, rescue equipment and medical supplies.
Co. HSE Advisor
HSE performance statistics, STOP/UAA analysis, dissemination of performance
statistics and all HSE advice/alerts, HSE training, HSE plan monitoring,
competence of advisor(s). Incident report input and quality control, issue of HSE
advice.
4
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Attachment 2 Page 1
Interview notes :
Name of interviewee: Date:
Job title:
Location of interview:
Years in present job:
Years in industry:
Training rec'd during last two years:
Reports to:
1
2
Responsibilities:
Meetings attended routinely:
Mgt visits:
Weekly HSE meeting topics:
Drills participated in:
2
3
Ways to improve HSE management:
Hazards which need addressing:
3
AUDITKIT97 4drilling.doc Drilling Audit Questionnaire Rev.A
Attachment 3 Page 1
List of Abbreviations
4WD Four wheel drive
B.A Breathing Apparatus
BPM Barrels Per Minute
BOP Blow Out Preventor
DEN Drilling Equipment Newsletter
DSV Drilling Supervisor
EA Environmental Assessment
ELCB Exposed Location Circuit Breaker
EMP Environmental Management Plan
ESD Emergency Shutdown
HLO Helicopter Landing Officer
IADC International Association of Drilling Contractors
ISC Integrated Services Coordinator
JSA Job Safety Analysis
MARPOL Marine Pollution
MODU Mobile Offshore Drilling Unit
MSDS Materials Safety Data Sheets
Medevac Medical Evacuation
NDT Non Destructive Testing
OBM Oil Based Mud
OIM Offshore Installation Manager
PIC Person In Charge
PMS Preventative Maintenance System
POB Persons On Board
PTW Permit to Work
RT Rotary Table
SPM Strokes Per Minute
SWL Single Weight Lift
TOR Terms Of Reference
UAA Unsafe Act Auditing
VAPS Vehicle Accident Prevention System
simops Simultaneous Operations
w.r.t. with respect to