RRC Fail Counter Analysis PDF

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Counter Name Sub Counter Name Counter explanation Cause & Solution

1. CE shortage;need CE
Number of failed RRC
expansion
C310080064 connection preparation,Due To Rl setup FAIL
2. Check alarm for more
Number of failed RRC Rl setup FAIL
C310080063 information
connection preparation, NodeB
Number of failed RRC
C310080065 connection preparation, Due Due To Rl setup expiry Transmission problem
To Rl setup expiry.
Number of failed RRC Code shortage, need traffic
C310080067 connection preparation, Due CODE Shortage balance, add new cell, second
To Codes carrier
Number of failed RRC Power shortage, need traffic
C310080068 connection preparation, Due DL POWER Shortage balance, add new cell, second
To DL POWER Shortage carrier
Number of failed RRC Check the reason for RTWP
Number of failed RRC
C310080066 connection preparation, Due increase, follow the
C310080069 connection preparation, Due UL Interference
To Admission Control interference shooting
To UL Interfere
document
Number of failed RRC
CE shortage;need CE
C310080070 connection preparation, Due UL CE
expansion
To UL CE Shortage
Number of failed RRC
CE shortage;need CE
C310080071 connection preparation, Due DL CE
expansion
To DL CE Shortage
Number of failed RRC 1. RCB OVERLOAD
C310080072 connection preparation, Due / / RL setup fail, Due to RNC 2. DSP on RUB not config IP
To RNC Internal Reasons address
Number of failed RRC
C310080077 connection preparation,Due To Iub Transmission Fail Transmission problem
Iub RlSetup TbFail
Number of failed RRC Number of failed RRC
C310080076 connection preparation, Due C310080078 connection preparation,Due To Iub Transmission access Fail Transmission problem
To Trans Iub RlSetup TbCacFail
Number of failed RRC
C310080079 connection preparation,Due To IUB Use Plane Fail Transmission problem
Iub UP Fail
Number of failed RRC Number of failed RRC
C310086446 connection preparation,Due To C310086447 connection preparation, Due CN OVERLOAD CN OVERLOAD
CN To CN Overload

CAUSE:
DSP Failed
Other hardware problem
RRC lodebalance strategy
Radio interface failure has
Have Sent RRC Connection Timer for RL restore is to short
been attributed to some
Number of failed RRC Setup,
hardware failures(in sympathy
C310080167 connection access, due to / / But do not received RRC SOLUTION: change hardware
with traffic as what happened
Radio Interface Synch. Connection Setup Complete or to check if it is the problem
at site selbone Park (BPC),
Radio Link Restore 1. change the site CMP
Nguboyenja (RRU))
2. change resource shelf
priority
if it worked, need upgrade or
repalce
Meanwhile, UU interface may
Have sent RRC Connection
require some downtilt
Number of failed RRC Setup, but do not receiced
adjustments and that is what I
C310080168 connection access, due to / / RRC Connection Setup N/A
will be doing for those cells
timeout of Uu interface Complete, but received Radio
with more than 100 RRC setup
Link Restore
blocked due to UU interfac
Have sent RRC Connection
Number of failed RRC
Setup,but do not received RRC
C310080169 connection access, due to / / N/A
Connection Setup Complete,
RNC Inner Reasons
because of RNC