No. Doc.

:
GENERIC HIRAC - RISK ASSESSMENT LEVEL 1 Revision : 0
Date : 5 January 2017

Location : Leader /
Plant / Project : Team member : ……………. (Maint. Mgr), Hendro, Karyono
Job/Work Date of assessment : 25 April 2017
Description : Maintenance of Burner Feed Water Revision No. :0

Hazard Identification Residual risk


Risk
Hazard
Source (combination of the likelihood
(source, situation, or act with Current risk Additional control
(Motion/movement, Height, of an occurrence of a hazardous Regulation PIC
a potential for harm in terms Risk control Risk measure (if necessary)
No. Temperature, Hazardouz Energy, event or exposure and the L S L S
of human injury or ill health, Level Level
Chemicals, Light, Noise, severity of injury or ill health
Property/Asset, Environment,
walking/working surface and space) that can be caused by the event
Reputation damages)
or exposure)
1 Motion/Movement:  Kondisi kunci tidak aman,  Kerusakan kondisi minor L4 S3 B  UU No. 1/ 1970  DCS in the L2 S2 D  Lakukan pre-task Maint.
 Penggunaan kunci G15 dan G16 salah penggunaan dan/ atau <$25K = (D/S2) pada kunci tentang BMS. briefing Team,
 Penggunaan troli cara yang salah dapat dan peluang mungkin terjadi Keselamatan  Automated  Barikade lingkungan (Welder,
 Proses manual handling mengakibatkan kerusakan Probable (L4) Kerja double block kerja Mech,
 Pemasangan pompa kunci, terkilir tangan  Lengan tangan terkiir tingkat  Kepmenaker No. and bleed on  Inspeksi alat-alat kerja Technicia
karyawan, jatuh cedera MT (C/S3) dan peluang ……… tentang pilot and main termasuk kunci, troly SHE
anggota badan Probable (L4) gas supply  Lakukan gas test personnel
 Penggunaan troli dengan  Luka tergores/ memar  WI Maint-  Pengawasan prilaku
cara yang salah dan. atau anggota badan MT (C/S3) enance BFW karyawan aman; posisi
kondisi tidak aman dengan peluang Probable (L4) (modifikasi karyawan badan tidak
 Proses manual handling/  Kerusakan toli kondisi <$25K line, bongkar berada di daerah line of
pengangkatan yang tidak (D/S2) dan peluang pasang, pasang fire
ergonomis Occasional (L3) spool, install  Pastikan APD standard
 Pemasangan belt; posisi  Punggung terkilir tingkat MT pompa) dan apron, welding
karyawan tidak egonomis, (C/S3) dan peluang gloves, dan kedok las
posisi tangan pada titik jepit Occasional (L3) terpakai
 Pemasangan pompa tidak  Luka sayat jari tangan tingkat
mengikuti SOP, posisi tidak MT (C/S3) dan peluang
ergonomis Probable (L4)

2 Height:
TBN
3 Temperature: Paparan lingkungan kerja yang '- karyawan cepat lelah karena L4 S3 B UU No. 1/ 1970 '- DCS in the L2 S2 D '-Pengaturan 'Maint.
panas melebihi suhu kamar dehidrasi dapat berakibat tentang BMS. Automated keseimbangan waktu Team,
Proses gerinda dan pengelasan dapat menyebabkan dehidrasi pingsan MT (C/S3), dan peluang Keselamatan Kerja double block and kerja dan istirahat (Welder,
Probable (L4) -Kepmenaker No. bleed on pilot - Penggunaan baju lengan Mech,
……… tentang and main gas panjang (tertutup) Technicia
supply - Pengaturan minum yang n), SHE
- WI Maintenance cukup personel
BFW (modifikasi
line, bongkar
pasang, pasang
spool, install
pompa)
4 Hazardouz Energy: - Kondisi kabel listrik mesin L4 S4 B UU No. 1/ 1970 '- DCS in the L2 S2 D '- Lakukan pemeriksaan 'Maint.
gerinda terkelupas '- karyawan tersetrum arus tentang BMS. Automated (checklist) mesin las, Team,
- Penggunaan mesin gerinda berenergi menyebabkan tersetrum listrik dapat berakibat Fatality Keselamatan Kerja double block and gerinda dan peralatan (Welder,
listrik (A/S5) peluang Probable (L4) bleed on pilot kerja lain aman dipakai Mech,
- Pemasangan batu gerinda - Permenaker No. and main gas - Penggunaan dan Technicia
- Penggunaan mesin las listrik terlalu ketat dapat pecah - Pecahan batu gerinda dapat 13/MEN/X/2011/ supply pemasangan batu gerinda n), SHE
menyebabkan amputasi mata NAB Faktor Fisika - WI Maintenance sesuai dengan personel
- Kualitas batu gerinda tidak Critical/ Disabling (B/S4), dan kimia BFW (modifikasi rekomendasi pabrik
baik/ aman dapat pecah peluang occasional (L3) line, bongkar - Pemasangan ELCB pada
-Permenaker No pasang, pasang kabel-kabel listrik'
- Melepas pengaman kick back - Pecahan batu gerinda dapat 02/MEN/1982 spool, install - Pelaksanaan isolasi dan
mesin gerinda, batu pecah menyebabkan luka sobek serius tentang kwalifikasi pompa) aplikasi LOTO
dapat mengenai badan/ wajah pada anggota tubuh Critical/ juru las listrik - Pamasangan fire blanket
karyawan Disabling (B/S4), peluang pada bagian yang
occasional (L3) potensial terkena
'- Kondisi kabel listrik mesin percikan api
las panas terkelupas - Busur api (percikan) dapat - Pengawasan karyawan
menyebabkan tersetrum dan/ berkibat kebakaran Serious secara ketat untuk
atau terbakar $25K-$100K (C/S3), peluang kepatuhan pelaksanaan
occasional (L3) safe work practice
- Busur api/ percikan tidak
terkendali dapat terbakar - Busur api (percikan) dapat
berkibat lika bakar Serious
$25K-$100K (C/S3), peluang
occational (L3)
5 Chemicals: '- Asap - Kabon Monoksida '- karyawan yang terhisap asap L4 S3 B UU No. 1/ 1970 '- DCS in the L2 S2 D -Pemasangan ventilasi 'Maint.
(CO) melebihi TWA 50 ppm CO dapat PAK keparahan MT tentang BMS. Automated tempat kerja yang Team,
Asap dan debu proses pengelasan dan dari proses las terhirup (C/S3), peluang Probable (L4) Keselamatan Kerja double block and memadai (Welder,
gerinda karyawan bleed on pilot -Penggunaan APD Mech,
- Debu dari proses gerinda - karyawan yang terhisap debu - Permenaker No. and main gas standard, termasuk Technicia
terhirup karyawan melebihi dapat PAK keparahan First Aid 13/MEN/X/2011/ supply respirator yang n), SHE
TWA (D/S2), peluang Probable (L4) NAB Faktor Fisika - WI Maintenance direkomendasikan personel
dan kimia BFW (modifikasi - Pengawasan safe work
line, bongkar practice karyawan
pasang, pasang
spool, install
pompa)

6 Light: Paparan Sinar Ultra Violet IUV) '- Paparan sinar UV dapat L4 S3 B UU No. 1/ 1970 '- DCS in the L2 S2 D Penggunaan APD yang 'Maint.
yang bekelebihan pada mata berakibat sobek retina mata tentang BMS. Automated standar ( googles, dll) Team,
Sinar UV karyawanan pengelasan karyawan (kebutaan) keparahan Keselamatan Kerja double block and (Welder,
Serius (C/S3), peluang Probable bleed on pilot Mech,
(L4) - Permenaker No. and main gas Technicia
13/MEN/X/2011/ supply n), SHE
NAB Faktor Fisika - WI Maintenance personel
dan kimia BFW (modifikasi
line, bongkar
pasang, pasang
spool, install
pompa)
7 Noise: Kebisingan melebihi TWA (> Paparan kebisingan dapat L4 S3 B UU No. 1/ 1970 '- DCS in the L2 S2 D -Pengendalian 'Maint.
85 dBA) saat menggerinda menyebabkan penurunan tentang BMS. Automated administrative dengan Team,
Kebisingan proses karyawanan gerinda pendengaran pada karyawan Keselamatan Kerja double block and mengatur jam kerja (Welder,
Serius (C/S3), peluang Probable bleed on pilot karyawan Mech,
(L4) -Permenaker No. 33 and main gas Technicia
tahun 2015 tentang supply -Penggunaan APD yang n), SHE
tingkat baku - WI Maintenance standar yang personel
kebisingan tingkat BFW (modifikasi direkomendasikan
baku kebisingan line, bongkar perusahaan.
pasang, pasang
-Permenaker No. spool, install
13/MEN/X/2011/ pompa)
NAB Faktor Fisika
dan kimia

UU No. 1/ 1970 '- DCS in the -Penempatan barang- 'Maint.


tentang BMS. Automated barang yang rapih Team,
'- Housekeeping yang buruk, Keselamatan Kerja double block and (Welder,
tidak terpeliharanya -Kepmenaker No. bleed on pilot -Penggunaan APD Mech,
- lingkungan yang buruk dapat
Walking/Working surface & space: lingkungan sekitar tempat ……… tentang and main gas standard, yang Technicia
menyebabkan karyawan
8 kerja, karyawan dapat terjatuh supply Direkomendasikan n), SHE
terjatuh, terpeleset, terbentur L4 S2 D L3 S2 D
- WI Maintenance personel
Minot (D/S2), peluang Probable
-Tidak memperhatikan cable BFW (modifikasi -Pengawasan safe work
(L4)
management, karyawan dapat line, bongkar practice karyawan
terjatuh pasang, pasang
spool, install
pompa)