Institute of Technology of Cambodia Hydropower &Pumping Station
Department of Rural Engineering
I. Instruction
‐ This assignment to be solved by everyone. It is an individual work.
‐ The score will be used as final score for Pumping station subject
‐ You must finish this assignment and submit both in print (hard copy by giving it to
secretary) and pdf (soft copy by giving it to your class Major) by Sunday 18, 2017
before 5PM. Missing or late submit will be given 0 point for your final grade.
‐ The questions and problem to be answered and solved are in section II bellow.
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
1. What did you learn from EBARA workshop 8‐9 June, 2017? What are new things
aside in class (pumping station) lecture? (10pt)
2. Explain clearly the various methods to control flow rate and compare their electrical
consumptions in water pumping system (which method is more efficiency? more
economic?) (20pt)
3. A centrifugal pump has the characteristics shown in table below. It is used lift water
between two reservoirs with a difference of elevation 0.5 m as shown in figure
below as well. The pipe connecting the reservoirs has diameter of 150 mm and is 800 m
long. The friction factor is assumed to be 0.01. The pipeline includes four standard
elbows and three gate valves. The entrance and exit are sharp. (30pt)
GOOD
LUCK
2. Controlling the discharge capacity with the number of pumps requires two or more pumps
installed in parallel. The number of operating pumps is changed in accordance with demand.
Determining the appropriate number of pumps that can accommodate the max. and the
min. demand is important for adopting discharge capacity control with the number of
pumps.
Even when discharge capacity control with the number of pumps has already been
adopted, changing the trigger values to change the number of operating pumps may
contribute to energy savings.
When 2 pumps are used
The figure below shows that when a high discharge capacity in needed, using a high-
capacity pump (broken line) achieves high efficiency, whereas when the required discharge
capacity is small, using two pumps can achieve high efficiency.
3.
Power consumption at
566.4 614.4 683.2
3 m3/min
3. A centrifugal pump has the characteristics shown in table below. It is used lift water between
two reservoirs with a difference of elevation 0.5 m as shown in figure below as well. The pipe
connecting the reservoirs has diameter of 150 mm and is 800 m long. The friction factor is
assumed to be 0.01. The pipeline includes four standard elbows and three gate valves. The
entrance and exit are sharp. (30pt)
a) Plot the characteristic curves including the system curves
b) Determine the rate of flow delivered by the pump
c) What is the power required?
Solution
a) Plot the characteristic curves including the system curves
Pipe Characteristics
Discharge (L/s) 0 5 10 15 20 25
Efficiency (%) 0 44 60 63 53 1
L V2
And, h friction h f
D 2g
V2 V2 V2 V2
hlocal hentrance helbow hgatevalve hexit K entrance 4K elbow 3K gatevalve K exit
2g 2g 2g 2g
Q2 L
H ha K entrance 4 K elbow 3K gatevalve K exit
D
2
2 gD 4
4
Q2 800
0.5 2
0.01 0.5 4 0.3 3 0.1 1
0.15
2 9.81 (0.15) 4
16
0.5 9194.36304 Q 2
Pump characteristics
Discharge (l/s) 0 5 10 15 20 25
Efficiency (%) 0 44 60 63 53 1
System characteristics
Ha (m) 5 5 5 5 5 5
1,
Q 19 l / s 1.14 m 3 / min
H 8.5 m
p 58% 0.58