Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Power

Generation

Cummins Natural Gas Generating Set


Range - 100 Kva
Options Technical Data
Gas Generating Set - Typical Maximum KWe Prime Power 80 - Radiator
Engine Rating at 50 Hz (0.8 p.f.) Cooling
Gas Generating Set - Typical KWe Baseload Power Rating at 65 - Radiator
❑ Spark arrester silencer 50 Hz (0.8 p.f.) Cooling
❑ Heavy duty air cleaner Output Voltage and Frequency 415 Volts, 50 Hz
❑ Heaters Power Factor 0.8 ( lag )
❑ Heat exchanger No.of Phases 3 Phase
❑ Hydraulic Governor with motorised head Overall Genset Dimensions (mm) Length 2868
Width 1006
Alternator Height 1870
Dry weight 1973
❑ Thermister Engine Model G - 743 - G
❑ PMG excitation No. of Cylinders 6
❑ Space heater Aspiration Naturally Aspirated
❑ 105 degree C temperature rise alternator Bore - mm 130
Stroke - mm 152
Control Panel Displacement - liter 12.2
Engine Output Prime - KWm (maximum) 102.2
❑ AMF control panel Engine Output Baseload - KWm (maximum) 86.9
❑ KW and Power factor meters Piston Speed - m / s 7.6
❑ Battery charger Break Mean Effective Pressure (BMEP) - kPa 670
❑ Remote and auto start panel Overall Engine Dimensions Length (Engine Only) 2082
❑ Auto / Manual synchronising panel Width (Engine Only) 811
❑ Indicating lamps for engine faults Height (Engine Only) 1695
/ Audio / Visual annunciation Dry weight of engine 1108
without cooling system
Others Engine Rating at 1500 RPM (BHP) 12.0 : 1 137
Piston Compression Ratio 10.0 : 1 129
❑ Acoustic enclosure 8.5 : 1 121
❑ Weatherproof enclosure Compression Ratio ( for following data ) **** 12:1
❑ Mobile set with canopy Natural Gas Consumption for Gas Calorific Value 31
(970 BTU/CFT or 8632 KCal/SM3) SCM/Hr
Exhaust Temperature ( Stack ) Deg C 649
Energy Input - KW 315

Power Energy Output - KW


Heat Rejected to Jacket Water - KW
102
108
Generation Heat Rejected to Aftercooler LTA Circuit - KW 0.0
Heat Rejected to Exhaust - KW 79
Heat Rejected to Ambient + Unaccounted - KW 26
Air Flow (Lit/Sec) 93
Cummins India Limited Exhaust Gas Flow - Lit / Sec 284
Energy Solutions Business Unit Exhaust System Permissible Back Pressure - mm Hg 76.2
35 A/ 1/ 2, Erandwana, Pune- 411 038 Engine Water Flow - (Lit / min) 212
Phone: (020) 402 7525 Fax: (020) 402 8090 After Cooler Circulating Water Flow - (Lit/Min) NA
Website: www.cumminsindia.com Raw water flow for Engine side Heat Exchanger 314
( 92 deg F / 32 deg C water inlet temperature ) - Lit / min
Raw water flow for Aftercooler Heat Exchanger NA
( 92 deg F / 32 deg C water inlet temperature )
Recommended Cooling Tower Capacity (TR)
Cummins has always been a pioneer in product improvement. Main Line Pipe size (mm) 40
Thus specifications may change without notice.
Illustrations may include optional equipment. Main Line Gas Pressure (kg/cm2) 1.4
Data is indicative and could vary based on gas composition and site conditions.
Data is based on typical natural gas with 970 BTU / CFT heat valve.