Range - 100 Kva Options Technical Data Gas Generating Set - Typical Maximum KWe Prime Power 80 - Radiator Engine Rating at 50 Hz (0.8 p.f.) Cooling Gas Generating Set - Typical KWe Baseload Power Rating at 65 - Radiator ❑ Spark arrester silencer 50 Hz (0.8 p.f.) Cooling ❑ Heavy duty air cleaner Output Voltage and Frequency 415 Volts, 50 Hz ❑ Heaters Power Factor 0.8 ( lag ) ❑ Heat exchanger No.of Phases 3 Phase ❑ Hydraulic Governor with motorised head Overall Genset Dimensions (mm) Length 2868 Width 1006 Alternator Height 1870 Dry weight 1973 ❑ Thermister Engine Model G - 743 - G ❑ PMG excitation No. of Cylinders 6 ❑ Space heater Aspiration Naturally Aspirated ❑ 105 degree C temperature rise alternator Bore - mm 130 Stroke - mm 152 Control Panel Displacement - liter 12.2 Engine Output Prime - KWm (maximum) 102.2 ❑ AMF control panel Engine Output Baseload - KWm (maximum) 86.9 ❑ KW and Power factor meters Piston Speed - m / s 7.6 ❑ Battery charger Break Mean Effective Pressure (BMEP) - kPa 670 ❑ Remote and auto start panel Overall Engine Dimensions Length (Engine Only) 2082 ❑ Auto / Manual synchronising panel Width (Engine Only) 811 ❑ Indicating lamps for engine faults Height (Engine Only) 1695 / Audio / Visual annunciation Dry weight of engine 1108 without cooling system Others Engine Rating at 1500 RPM (BHP) 12.0 : 1 137 Piston Compression Ratio 10.0 : 1 129 ❑ Acoustic enclosure 8.5 : 1 121 ❑ Weatherproof enclosure Compression Ratio ( for following data ) **** 12:1 ❑ Mobile set with canopy Natural Gas Consumption for Gas Calorific Value 31 (970 BTU/CFT or 8632 KCal/SM3) SCM/Hr Exhaust Temperature ( Stack ) Deg C 649 Energy Input - KW 315
Power Energy Output - KW
Heat Rejected to Jacket Water - KW 102 108 Generation Heat Rejected to Aftercooler LTA Circuit - KW 0.0 Heat Rejected to Exhaust - KW 79 Heat Rejected to Ambient + Unaccounted - KW 26 Air Flow (Lit/Sec) 93 Cummins India Limited Exhaust Gas Flow - Lit / Sec 284 Energy Solutions Business Unit Exhaust System Permissible Back Pressure - mm Hg 76.2 35 A/ 1/ 2, Erandwana, Pune- 411 038 Engine Water Flow - (Lit / min) 212 Phone: (020) 402 7525 Fax: (020) 402 8090 After Cooler Circulating Water Flow - (Lit/Min) NA Website: www.cumminsindia.com Raw water flow for Engine side Heat Exchanger 314 ( 92 deg F / 32 deg C water inlet temperature ) - Lit / min Raw water flow for Aftercooler Heat Exchanger NA ( 92 deg F / 32 deg C water inlet temperature ) Recommended Cooling Tower Capacity (TR) Cummins has always been a pioneer in product improvement. Main Line Pipe size (mm) 40 Thus specifications may change without notice. Illustrations may include optional equipment. Main Line Gas Pressure (kg/cm2) 1.4 Data is indicative and could vary based on gas composition and site conditions. Data is based on typical natural gas with 970 BTU / CFT heat valve.