Techincal Specifications With Details

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 11

Techincal Specifications with Details

CONTINUOUS / LIQUID PRESSURE

Measuring Principle Absolute and gauge pressure

Characteristic / Application Digital transmitter with piezo resistive sensor and diaphragm
seal
Modular transmitter
Long term stability
Minimum oil volume
Enhanced safety via self-diagnostic functions
Secondary process barrier

Specialities Diagnostic functionalities


Different languages in software

Supply / Communication 4...20mA HART:


10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC

Accuracy 0,075% + influence of diaphragm seal

Long term stability 0,05% of URL/year

Ambient temperature -40°C...85°C


(-40°F...185°F)

Process temperature -70°C...400°C


(-94°F...752°F)

Process pressure absolute 1050bar (15,200psi)


/ max. overpressure limit

Pressure measuring range 100mbar...400bar


(1.5psi...5800psi)

Main wetted parts Alloy C276


316L
Monel
Tantalum
PTFE-Foil

Process connection Threads


Flanges (DIN, ASME, JIS) with flush membrane
Tri-Clamp ISO02852
Hygienic connections

Max. measurement 7000m (22.966ft) H2O


distance
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus

Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing

Application limits Measuring cell: Metal welded


If pressurized, possibly use differential pressure meas-urement
with two pressure transmitters (electronic dp). Observe ratio
head pressure : hydrostatic pressure
Flow Meter

Measuring Principle Electromagnetic

Product headline Sensor with certified corrosion protection (EN ISO 12944) and a state‐
of‐the‐art transmitter for Water & Wastewater. For direct underground
installation or permanent underwater use. The specialist in the water
and wastewater industry for the most demanding applications.

Sensor features Secure, reliable long‐term operation – robust and completely welded
sensor. Energy‐saving flow measurement – no pressure loss due to
cross‐section constriction. Maintenance‐free – no moving parts.
International drinking water approvals. Degree of protection IP68 (Type
6P enclosure).

Transmitter Safe operation – no need to open the device due to display with touch
features control, background lighting. Time-saving local operation without
additional software and hardware – integrated web server. Integrated
verification – Heartbeat Technology. Transmitter housing made of
durable polycarbonate or aluminium. WLAN access.

Nominal diameter DN 25 to 2000 (1 to 78")


range

Wetted materials Liner: Polyurethane; Hard rubber


Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Measured variables Volume flow, conductivity, mass flow

Max. measured Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
error Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec

Measuring range 9 dm³/min to 110 000 m³/h (2.5 gal/min to 700 Mgal/d)

Max. process PN 40, Class 300, 20K


pressure

Medium Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)


temperature range Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)

Ambient Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)


temperature range Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)

Sensor housing DN 25 to 300 (1 to 12"): AlSi10Mg, coated


material DN 25 to 2000 (1 to 78"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate

Transmitter Polycarbonat; AlSi10Mg, coated


housing material

Degree of Compact version: IP66/67, type 4X enclosure


protection Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure, with
protective varnish
according to EN ISO 12944 C5‐M/Im1/Im2/Im3
Transmitter remote version: IP66/67, Type 4X enclosure

Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display, web browser and operating tools
possible

Outputs 3 ouputs:
0‐20 mA/4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Pulse/frequency output (passive)
Switch output (passive)

Inputs Status input

Digital HART, PROFIBUS DP, EtherNet/IP, Modbus RS485


communication

Power supply AC 100…240 V / AC/DC 24 V

Level Meter

Measuring Principle Ultrasonic

Product headline Compact ultrasonic measuring


instrument
Cost effective solution for open
channel

Max. measured error Low accuracy

Measuring range 0,25...5m [0.8...16ft]

Max. process pressure atm.

Medium temperature -40°C ... 80°C


range (-40°F...176°F)
Degree of protection IP68

Outputs 4...20mA(Hart),PA,FF

Inputs 2-wire 16-36V DC,


4-wire 16-36V DC,
90-253V AC 50/60Hz

Digital communication PROFIBUS PA


FOUNDATION Fieldbus

Energy Meter

Power Source From L1 Phase to L2 Phase or USB

Connection Points • USB A/B Connector - Computer connection using a USB A/B cable
• N, L1, L2, and L3 - Line voltage connection points
• CT1, CT2, and CT3 - Current Transformers connection points
• HART Communication Terminals

Phase Check LEDs • LEDs CT1, CT2, and CT3 - Phase connection check and health of unit

Wireless HART • Remotely adjustable reporting interval


Mesh Features • Received Signal Strength Indication (RSSI) available for radio signal
monitoring
• Automatic self-healing mesh network
• Ease of adding and removing sensors

Gateway Any WirelessHART Gateway

Approximate 26.7 x 9.1 x 4.0 cm (10.5” x 3.6” x 1.6” in


Dimensions (L x W
x H)

Operational Temperature: -20°C to +55°C [20°F to +131°F] / Humidity: 5% to 90%


Environment (non-condensing)

Regulatory • Compliant with FCC, UL Listed, and CE Mark


• Conforms to UL Std. 61010-1
• Certified to CSA Std C22.2 No. 61010-1, 3rd Edition
Electrical Details • Service Type - Single Phase, 3 Phase-4 Wire (WYE), 3 Phase-3 Wire
(Delta)
• Voltage channels - 80-346 Volts AC Line-to-Neutral, 600V Line-to-Line,
CAT III
• Line frequency - 50/60 H

Measurement • Measurement type - True RMS using high-speed digital signal


Details processing (DSP)
• Measurement variables - Volts, Amps, kW, kWh, kVAR, kVARh, kVA,
kVAh, Apparent Power Factor, Displacement Power Factor
• Averaged variables - Volts, Amps, kW, kVA, kVAR, Apparent Power
Factor, Displacement Power Factor
• All parameters for each phase and system total
• Resolution - 0.01 Amp, 0.1 Volt, 0.01 Watt, 0.01 VAR, 0.01 VA, 0.01
Power Factor depending on scalar setting
• Accuracy - 0.2% (<0.1% typical) ANSI C12 .20-2010 class 0.

Current Channels 3 channels, 0.52 VAC max, 333 mV CTs, 0-4000A

Waveform 12 kHz (200 Samples/60Hz, 240 Samples/50Hz)


Frequency

Ingress Protection 20
Rating

Enclosure ABS Plastic, 94-VO Flammability Rating

Chlorine Analyzer (Sensors)

Measuring Total Chlorine


Principle

Application Potable water,Process water, Waste water, pools

Characteristic Amperometric measurement of total chlorine.

Measurement 0,1 - 10ppm total chlorine; pH 6,5 - 9,5


range

Measuring - Total chlorine consists of free chlorine (HOCl, OCl) and bounded chlorine
principle (chloramines).
- A constant polarisation voltage between working and counter electrode
instigates the electrochemical reaction.
- Only slightly pH dependent.

Design Closed amperometric two electrode sensor for continuous measurement of total
chlorine.

Material Sensor shaft : PVC


Membrane cap : PPE

Dimension Diameter : appr. 25mm


Length : 210mm

Process 5°C - 45°C


temperature

Process pressure 0bar - 3bar

temperature Including NTC-temperature sensor.


sensor

Connection TOP68 plug-in head

pH Analyzer (Sensor) (Raw Water)


Measuring Glass electrode
Principle

Application Standard applications in process and environment. Long-term


monitoring, processes with little change.

Characteristic Very robust, heavy-duty version / high pressure, integrated potential


matching, flat membrane available.

Measurement pH 0-14
range

Measuring Gel compact electrode with PTFE ring-diaphragm.


principle

Design - all shaft lengths with temperature sensor, advanced gel technology -
digital electrode with Memosens technology

Material Glass / PTFE

Process Max. 135°C (274°F)


temperature

Process pressure Max. 16 bar (230 psi)

temperature NTC 30k


sensor

Connection Inductive, digital connection head with Memosens technology.

pH Analyzer (Sensor) (Clear Water)

Measuring Glass electrode


Principle

Application Hygienic and sterile applications, process

Characteristic - resistant against reference poisoning - CIP/SIP and autoclavable - high


accuracy - biocompatibility of the gel inside (EHEDG, 3A) - version upside-
down installation available - pressurized reference (6 bar) available
Measurement pH 0-14
range

Measuring - ceramic diaphragm - ion-trap


principle

Design - All shaft lengths with temperature sensor - advanced gel technology -
digital electrode with Memosens technology

Material glass / ceramic

Process -15°C ... 140°C


temperature (5°F - 284°F)

Process max. 13 bar


pressure (188 psi)

temperature NTC 30k


sensor

Connection Inductive, digital connection head with Memosens technology.

Turbidity (Sensor)

Measuring Principle Four beam alternating light

Application Turbidity in the effluent of WWTP, solids in the biological process and in different
sludge

Installation Inset (immersion in process or retractable holder), extractive with sample and flow
cell

Measurement 0..9999 FNU, 0..150g/l SS


range

Measuring principle Scattered light in 90°/135° and 4beam cross light

Design 40 mm sensor, stainless steel

Material stainless steel 316L

Dimension 194 mm x 40 mm

Process Process temperature -50 ... 50°C / 23 ... 120°F Ambient temperature -20 ... 60°C / -4
temperature ... 140°F

Connection G1, NPT3/4

Ingres protection IP68 (1m/3,3ft) water column with 1N KCl during 60 days
Analyzer(s) Transmitter
Measuring Sensor ORP / Redox
Principle

Application Modular 4 wire controller


Multichannel:1-8 digital channels for Memosens protocol
Multipara meter: pH, redox, ISFET, conductivity inductive and conductive,
dissolved oxygen, nitrate and turbidity
8 sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors

Characteristic Robust plastic housing


All non-ex applications

Design 8x Memosens input


2...8x current output
alarm relay
2x relay
SD card for software update and copy & paste of setup

Material Polycarbonate

Process -20...55°C / 0...130°F


temperature

Ingres protection IP67

Input 1...8x Memosens digital input 2x 0/4..20mA Input optional 2..4x Digital input
optional

Output 2...8x 0/4...20 mA current outputs


alarm relay
4x relay
Pro fi bus DP
Modbus RS485
Modbus TCP
Ethernet

WirelessHART Adapter
Measuring Principle WirelessHART

Function Intelligent WirelessHART interface module for connection to 4...20


mA/HART devices

Certification Non-hazardous area


ATEX II 2G Ex ia IIC T4/T3 Gb
ATEX II 2G Ex ia IIC T4/T3 Gb, ATEX II 2D Ex tb [ia] IIIC T60oC Db
CSA general purpose
CSA C/US IS Cl.I,II,III Div.1 Gp.A-G, NI Cl.I Div.2 AEx ia
IECEx Ex ia IIC T4/T3 Gb, IECEx Ex tb [ia] IIIC T70oC Db, IECEx Ex ia IIC
T4/T3 Gb

Input One point-to-point with a HART device, or


One point-to-point connection with a 4...20 mA device, or
Up to four HART field devices connected in multidrop mode if a wide
range power unit is used.

Output WirelessHART communication interface


Transmission rate: Nominal 250 kBits/s
Operating frequency: 2.4 GHz (ISM band)
Transmission range under reference conditions:
Outdoor 250 m, indoor 50 m

Auxiliary power supply / Special long life lithium thionylchloride battery pack
Loop power supply 24-230V AC/DC external power
DC power unit

Software Internal software for controlling, powering, and reading from 4…20
mA/HART field devices

Operation Integral via Pushbutton, PC configuration via DTM and FieldCare or


DD

Display Integral via 3 LEDs

Operating Voltage Special long life lithium thionylchloride battery pack


For versions with electronically regulated power supply:
Wide-range power supply: 24 V...230 V AC/DC ± 10%, 50/60 Hz
DC power unit: 8 V...50 V DC ± 10%
In the event of an external power supply failure, wireless
communication is maintained for at least one hour by means of an
internal supply.

WirelessHART Fieldgate
Measuring Principle WirelessHART

Function Intelligent WirelessHART gateway with Ethernet and RS-485


interfaces

Certification Non-hazardous area


ATEX II 3G Ex nA II T4
IECEx Ex nA nC IIC T4 Gc
FM Cl. I, Zone 2 AEx nA nC IIC T4 Gc
FM Cl. I, Zone 2 Ex nA nC IIC T4 Gc

Input WirelessHART communication interface


Transmission rate: Nominal 250 kBits/s
Operating frequency: 2.4 GHz (ISM band)
Transmission range under reference conditions:
Outdoor 250 m, indoor 50 m

Output Ethernet (10 BASE-T/10 BASE TX)


- Configurable for HART IP and MODBUS TCP communication
RS-485 serial interface
- Configurable for HART Version 7.0 or MODBUS RTU
communication
EtherNet/IP interface

Auxiliary power supply / 20 VDC to 30 VDC


Loop power supply

Dimensions (wxhxd) W x H x D:
257 mm x 85 mm x 285 mm with cable glands and antenna
257 mm x 85 mm x 115 mm without cable glands and
antenna

Software Internal software for controlling the WirelessHART network


including web interface for configuration.

Operation Integral via Pushbuttons


PC configuration:
- Web browser via Ethernet
- FieldCare via Ethernet (HART IP CommDTM) or RS-485 (S-
MUX DTM)

Display Integral via 5 LEDs

Operating Voltage 20 VDC to 30 VDC

Nominal current <5 W

Data Logger

Measuring Principle Energy manager

Functions Secure data recording and signal analysis


Visualization
Integrated web server for device set-up
HART(R) transparency, RSG45 as a HART modem
E-Mail notification (encrypted mails)
100 ms scan rate, high speed storage cycle 100 ms
Modular design for simple expansion
Data readout and processing via Field Data Manager Software
OPC server for indication of instantaneous values (optional)

Maximal input 20 Analog (U, I, TC, RTD, frequency, impulse)


20 HART (HART, 4…20mA)
14 Digital (control-, event- und counting input)

Maximal output 12 Relays


2 Analog (I, Puls)
1 Transmitter power supply

Interface RS232/485
Ethernet
USB´
Modbus RTU/TCP Slave (optional)
Modbus RTU/TCP Master (optional)
Profibus DP(optional)
PROFINET IO-Device (optional)
EtherNet/IP Server

Storage/Recording Internal memory


SD card
USB flash drive

Display TFT 7" colour graphic display


TFT 7" colour graphic display with touch panel

Housing Panel mounting with zink diecast bezel


Panel mounting with stainless steel bezel
Desktop housing
Field housing

Power supply 100...230 V AC +/-10%


24V (-10%; +15%) AC/DC

Software package Mathematic


Telealarm
Batch software
Waste water + storm overflow
Energy software

You might also like