LOW VOLTAGE AUTOMOBILE WIRES & CABLES (JASO D611-94) SOUTHERN CABLE

TYPE AVS, AVSf

Construction of thin Insulation Wall Cables (Types AVS, AVSf)

Insulation
Nom. Size Conductor Overall Dia.
Thickness Conductor
Resistance
Approx. Outside o
at 20 C
Stranding Calculated Area Std. Min. Std. Max.
Diameter

mm2 No./mm mm2 mm mm mm mm mm W/m


0.3 7/0.26 0.3716 0.8 0.5 0.32 1.8 1.9 0.0502

0.5 7/0.32 0.5629 1.0 0.5 0.32 2 2.1 0.0327

0.5f 20/0.18 0.5087 1.0 0.5 0.32 2 2.1 0.0367

0.85 16/0.26 0.8494 1.2 0.5 0.32 2.2 2.3 0.022

1.25 16/0.32 1.287 1.5 0.5 0.32 2.5 2.6 0.0143

1.25f 50/0.18 1.273 1.5 0.5 0.32 2.5 2.6 0.0147

2 26/0.32 2.091 1.9 0.5 0.32 2.9 3.1 0.00881

3 41/0.32 3.297 2.4 0.6 0.48 3.6 3.8 0.00559

5 65/0.32 5.228 3.0 0.7 0.56 4.4 4.6 0.00352


Remark : f means flexible conductor

Abrasion Data for AVS and AVSf


Min Abrasion
Nom. Size Mass of Load
Resistance
mm2 mm g
0.3 457 450

0.5 457 450

0.75 535 450

0.85 535 450

1.25 560 450

2 305 1350

3 410 1350

5 & Above 510 1350

http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
LOW VOLTAGE AUTOMOBILE WIRES & CABLES (JASO D611-94) SOUTHERN CABLE

TYPE AVSS, AVSSf, CAVS

Construction of Thin Insulation Wall Cables (Types AVSS, AVSSf)


Conductor Insulation Thickness Overall Dia. Conductor
Nom.
Calculated Approx. Resistance at
Size Stranding Std. Min. Std. Max. o
Area Outside Dia. 20 C
mm2 No./mm mm2 mm mm mm mm mm W/m
0.3 7/0.26 0.3716 0.8 0.30 0.24 1.4 1.5 0.0502
0.3f 19/0.16 0.3821 0.8 0.30 0.24 1.4 1.5 0.0488

0.5 7/0.32 0.5629 1.0 0.30 0.24 1.6 1.7 0.0327

0.5f 19/0.19 0.5387 1.0 0.30 0.24 1.6 1.7 0.0346

0.75f 19/0.23 0.7895 1.2 0.30 0.24 1.8 1.9 0.0236

0.85 19/0.24 0.8596 1.2 0.30 0.24 1.8 1.9 0.0217


1.25 19/0.29 1.255 1.5 0.30 0.24 2.1 2.2 0.0149

1.25f 37/0.21 1.282 1.5 0.30 0.24 2.1 2.2 0.0146

2 19/0.37 2.043 1.9 0.40 0.32 2.7 2.8 0.0090

2f 37/0.26 1.964 1.8 0.40 0.32 2.6 2.7 0.0095


Remark : f means flexible conductor

Construction of Thin - Insulated Cables (Types CAVS)


Conductor Insulation Thickness Overall Dia. Conductor
Nom.
Calculated Approx. Resistance at
Size Stranding Std. Min. Std. Max.
Area Outside Dia. 20oC

mm2 No./mm mm2 mm mm mm mm mm W/m


0.3 7/0.26 0.3716 0.7 0.30 0.24 1.4 1.5 0.0502
0.5 7/0.32 0.5629 0.9 0.30 0.24 1.6 1.7 0.0327

0.85 11/0.32 0.8846 1.1 0.30 0.24 1.8 1.9 0.0208

1.25 16/0.32 1.2877 1.4 0.30 0.24 2.1 2.1 0.0143

http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently
evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our
product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
LOW VOLTAGE AUTOMOBILE WIRES & CABLES (JASO D611-94) SOUTHERN CABLE

TYPE AV, AVF, HAV

Construction of PVC - Insulated Cables (Types AV, Avf, HAV)


Conductor Insulation Thickness Overall Dia. Conductor
Nom. Size Calculated Approx. Resistance
Type Stranding Std. Min. Std. Max.
Area Outside Dia. at 20oC

mm
2
No./mm mm
2
mm mm mm mm mm W/km
0.3 7/0.26 0.3716 0.8 0.50 0.40 1.9 2.0
0.3f 12/0.18 0.3054 0.8 0.60 0.48 2.0 2.2
0.5 7/0.32 0.5629 1.0 0.60 0.48 2.2 2.4
0.5f 20/0.18 0.5087 1.0 0.60 0.48 2.2 2.4
0.75f 30/0.18 0.763 1.2 0.60 0.48 2.4 2.6
0.85 16/0.26 0.8494 1.2 0.60 0.48 2.4 2.6
0.85f 33/0.18 0.8397 1.2 0.60 0.48 2.5 2.7
AV & AVF 1.25 16/0.32 1.287 1.5 0.60 0.48 2.7 2.9 0.00881
1.25f 50/0.18 1.273 1.5 0.60 0.48 2.7 2.9
2 26/0.32 2.091 1.9 0.60 0.48 3.1 3.4
2f 37/0.26 1.964 1.8 0.70 0.56 3.4 3.6
3 41/0.32 3.297 2.4 0.70 0.56 3.8 4.1
5 65/0.32 5.228 3.0 0.80 0.64 4.6 4.9
8 50/0.45 7.952 3.7 0.90 0.72 5.5 5.8
15 84/0.45 13.26 4.8 1.10 0.88 7.0 7.4
o
HAV 105 C 0.5 7/0.32 0.5629 1.0 1.00 0.80 3.0 3.2 0.0327
HAV 0.85 11/0.32 0.8846 1.2 1.00 0.80 3.2 3.4 0.0208

Construction of Thin Insulation Wall Cables (Types EB)


Conductor Insulation Thickness Overall Dia. Conductor
Nom. Size Calculated Approx. Resistance at
Stranding Std. Min. Std. Max.
Area Outside Dia. 20oC

mm2 No./mm mm2 mm mm mm mm mm W/m


5 65/0.32 5.228 3.0 0.80 0.64 4.6 4.9 0.00352
15 19/9/0.32 13.75 5.3 0.60 0.48 6.5 6.9 0.00132
20 19/13/0.32 19.86 6.5 0.60 0.48 7.7 8.1 0.000915

Construction of Thin Insulation Wall Cables (Types HEB)


Conductor Insulation Thickness Overall Dia. Conductor
Nom. Size Calculated Approx. Resistance at
Stranding Std. Min. Std. Max.
Area Outside Dia. 20oC

mm2 No./mm mm2 mm mm mm mm mm W/m


10 19/6/0.32 9.17 4.2 1.0 0.88 6.2 6.6 0.00196
15 19/9/0.32 13.75 5.2 1.10 0.88 7.4 7.8 0.00132
20 19/13/0.32 19.86 6.2 1.10 0.88 8.4 8.8 0.000915