1-General Information : Girder ID = MBT-1-1 *Total No of Girders = 18 Girder Length = 29.5 m 2- . Calculation for Round Duct Length : Profile Length Duct Diameter STD Duct Length No of Ducts Tendon No (mm) (mm) (mm) Required T#1 29510.83 85 4000 8 T#2 29510.83 85 4000 8 T#3 29583.48 90 4000 8 3- Calculation for Couplers Length : Coupler Standard coupler No of Couplers Length of Coupler Tendon No Diameter Length (mm) Required (mm) (mm) T#1 400 88 7 2800 T#2 400 88 7 2800 T#3 400 93 7 2800 4- Round Duct required for one beam : * Total Length of Duct : 85 mm Duct Length for T1&T2 = 66.24 m 90 mm Duct Length for T3 = 33.12 m * Total Length of Couplers: 88mm Coupler Length for T1&T2 = 5.80 m 93mm Coupler Length for T3 = 2.90 m 5- Calculation for Flat Duct Length :
Profile Length Duct Diameter STD Duct Length No of Ducts
Tendon No (mm) (mm) (mm) Required T#1 5275 90x23 4000 2 T#2 5275 90x23 4000 2 T#3 8775 90x23 4000 3 T#4 8775 90x23 4000 3 6- Calculation for Couplers Length : Coupler Standard coupler No of Couplers Length of Coupler Tendon No Diameter Length (mm) Required (mm) (mm) T#1 400 93x26 1 400 T#2 400 93x26 1 400 T#3 400 93x26 2 800 T#4 400 93x26 2 800 7- Flat Duct required for one beam : * Total Length of Duct : 90x23 mm Duct Length for T1&T2 = 16.56 m 90x23 mm Duct Length for T3&T4 = 24.84 m * Total Length of Couplers: 93x26mm Coupler Length for T1&T2 = 0.83 m 93x26mm Coupler Length for T3&T4 = 1.66 m * Including wastage