KEY PLAN

03
01
02

NOTES:

7200 +17.40M FFL (21.689M FFL)


ROOF FLOOR LVL.

ROOF
SKY LIGHT

UP

0.7mm THICK ALUMINIUM CLADDING


WITH 100mm THICK INSULATION.
+13.80M FFL (18.089M FFL) 0.7mm THICK ALUMINIUM CLADDING
WITH 100mm THICK INSULATION.
(CLADDING COLOUR APPROVED BY THE CONSULTANT) (CLADDING COLOUR APPROVED BY THE CONSULTANT)
FOURTH FLOOR LVL.
STEEL 'Z' PURLIN AS PER STEEL STEEL 'Z' PURLIN AS PER STEEL
STRUCTURE SPECIALIST DESIGN STRUCTURE SPECIALIST DESIGN

+13.275 M +13.275 M
STEEL FRAMING TO SUPPORT STEEL FRAMING TO SUPPORT
EXTERNAL CLADDING EXTERNAL CLADDING

4MM THICK APPROVED 4MM THICK APPROVED


ALUMINUM COMPOSITE PANEL ALUMINUM COMPOSITE PANEL

PARKING BLOCK
+10.50M FFL (14.789M FFL)
THIRD FLOOR LVL.
PROPOSED CROSS OVER
WEIGHT OF MEP SERVICES 50 Kg.
Per Sq.Mtr.

B B +9.075 M
PROPOSED CROSS OVER
+9.075 M

SKY LIGHT WEIGHT OF MEP


SERVICES 50 Kg. PROPOSED CROSS OVER
Per Sq.Mtr. WEIGHT OF MEP
SERVICES 50 Kg.
Per Sq.Mtr.
PARKING BLOCK
1 A-103 SECOND FLOOR ARCHITECTURAL PLAN LAYOUT 6
+7.20M FFL (11.489M FFL)
2 A-703 SECOND FLOOR FALSE CEILING PLAN LAYOUT 5
SECOND FLOOR LVL.
3 S-DT-115 THIRD FLOOR STRUCTURAL PLAN LAYOUT 3
M
4 M-HVAC-104 SECOND FLOOR PLAN HVAC LAYOUT 4

5 M-HVAC-501 HVAC EQUIPMENT SCHEDULE (SHEET 1 TO 3) 4

6 M-HVAC-201 CHILLED WATER SCHEMATIC LAYOUT 4

7 M-HVAC-301 VENTILATION AND SMOKE SCHEMATIC LAYOUT 3

PARKING BLOCK
REVIEW STATUS
+4.950M FFL +4.950M FFL A APPROVED
+4.950 M +4.950 M
(9.239M FFL) (9.239M FFL)
B APPROVED AS NOTED

C REVISE and RESUBMIT

D NOT APPROVED
ROOF +3.90M FFL (8.189M FFL)
FIRST FLOOR LVL.

A A

PROJECT :
PARKING
(G+4) OFFICE BUILDING
DN FOR DEWA
CLIENT :

+0.75M FFL (5.16M FFL) +0.75M FFL (5.16M FFL) +0.75M FFL (5.16M FFL)
GROUND FLOOR LVL. SECTION B-B GROUND FLOOR LVL. GROUND FLOOR LVL. SECTION A-A
Dubai Electricity & Water Authority
P.O.BOX : 564, DUBAI - U.A.E.
TEL : 00971 4 3072222
FAX : 00971 4 3248111
A

CONSULTANT :
M

ENGINEERING
CONSULTANTS ‫ييةهلتةاةل ةيسدنهلا‬
P.O.BOX : 11676, DUBAI - U.A.E.
TEL : 00971 4 3555949 , FAX : 00971 4 3555405

FRESH AIR MAIN CONTRACTOR :


HALL PROVIDED IN (OPEN BELOW)
F/C 3000 AHU-AT 1/ROOF REEM CAPITAL CONTRACTING LLC.
VP

RMB Group
P.O.BOX : 454481, DUBAI - U.A.E.
TEL : 00971 4 3792264 / 3927435
FAX : 00971 4 3555405

MEP CONTRACTOR :
INTERNATIONAL
GBH CONTRACTING L.L.C
P.O. BOX: 454481, Tel : +971 4 3792264
+971 4 3927435 Fax : +971 4 3792644
RMB Group
DUBAI, U.A.E

DRAWING TITLE :
SECOND FLOOR
DUCT SUPPORTS
(SHEET 1 OF 2)
JOB NO PLOT NO BLOCK
1215 322-178 AL HUDAIBA

Drawn: RAMESH Checked: HAREESH Approved:

Scale: 1:100 @ A1 Date: 25/01/2018 Date:

DRAWING No. : Rev.:


DEWA-GBHIC-SD-DR-1001 - SHT1OF2 00