• Detailed graphical representation of virtually any type of • Different cable types within one installation.
power cable. This facility can be used to modify existing • Non-isothermal earth surface modeling.
cables and enrich the cable library with new ones. • Cyclic loading patterns as per IEC-60853©, including soil
This includes single-core, three-core, belted, pipetype, dry out.
submarine, sheathed, and armored cables.
• Multiple cables per phase with proper modeling of the
• Different cable installation conditions such as directly sheath mutual inductances which greatly influence
buried, thermal backfill, underground ducts or duct banks. circulating current losses and thus de-rating.
• Cables in pipes with the pipe directly buried or in a thermal • All bonding arrangements for flat and triangular formations
backfill. are supported with explicit modeling of minor section
• Independent libraries and databases for cables, duct- lengths, unequal cable spacing, etc.
banks, load curves, heat sources and installations.
www.cyme.com | www.cooperpowereas.com
Cooper Power Systems, CYME, all CYME module names, CYMDIST Gateway, CYMTCC, CYMCAP, all CYMCAP module names, CYMGRD are valuable trademarks of
Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.
Other Trademarks: The names of all products, standards and services other than Cooper’s and CYME’s mentioned in this document are the trademarks or trade names
of their respective owners.
©2009 Cooper Industries. All Rights Reserved.
CYMCAP Simulates ampacity and temperature rise
calculations in power cable installations.
Power Cable Ampacity
Transient Analysis
Power Engineering
The program supports a Transient Thermal Analysis Software
Analysis option which includes the following:
• Ampacity given time and temperature. CYMDIST – Distribution
System Analysis
• Temperature analysis given time and
• Balanced/unbalanced load
ampacity.
flow
• Time to reach a given temperature, given • Network optimization
the ampacity.
• Distributed generation
• Ampacity and temperature analysis as a modeling
function of time.
• Short-circuit analysis
• User-defined load profiles per circuit. • Energy profile manager
• Multiple cables per installation. • Switching optimization
• Circuits can be loaded simultaneously or Cables on Riser Poles • Harmonic analysis
one at a time.
• Predictive and historical
reliability assessment
• Contingency analysis
• Substation and sub-network
modeling and analysis
• Secondary network analysis
• Motor starting
CYMTCC – Protective Device
Coordination
CYMDIST Gateway – Creation
and maintenance of CYMDIST
Distribution Network Model
Heat Source and Heat Sink
CYMGRD - Substation
Grounding
CYMCAP – Power Cable
Ampacity
• Duct bank optimizer
• Multiple duct banks
modeling
• Short-circuit cable rating
• Magnetic fields
• Cables in tunnels modeling
• Real-time temperature rating
• Cable crossings ampacity
reduction calculation
• Ampacity/temperature
calculation of cables in
casings
• Cables parameters
estimation
Visit www.cyme.com/software
for more information.