Auditorium space types are areas for large meetings, presentations, and performances. Auditorium space type facilities may include
assembly halls, exhibit halls, auditoriums, and theaters. Auditorium space types do not include such features as sound
reinforcement systems, audiovisual systems and projection screens, food service facilities, proscenium stages with heights greater
than 50'– 0" or fly gallery, orchestra pits, revolving or hydraulic stage platforms, flying balconies, movable seating, or billboard
systems.

SPACE ATTRIBUTES
Auditorium spaces are designed to accommodate large audiences. As such, they tend to have wide spans and are multiple-stories
high in order to accommodate seating, sightlines, and acoustical requirements. Raised stage/dais floors and special lighting
equipment are often required as well. Typical features of Auditorium space types include the list of applicable design objectives
elements as outlined below. For a complete list and definitions of the design objectives within the context of whole building design,
click on the titles below.

ACCESSIBLE AND FUNCTIONAL / OPERATIONAL

 Sloped Floors: Sloped floors, with level terraces for each row of seating, help provide the proper sightlines from the
audience to the stage. Note that the bottom and intermediate rows should be directly accessible from entry levels to allow
for Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG) compliant accessible
seating positions. See also WBDG Accessible.

 Fixed Seats: Typically, fixed seats with tilting upholstered seat and back, integral arm and tablet arm are provided with
articulated back for maximum occupant passage space between rows. The seats may be fully upholstered or wood
contoured outer back and seat shells with wood armrests with tablet arm option and aisle light option at row ends. Seat
number/row letters should be Americans with Disabilities Act (ADA) compliant. Wheelchair access option-removable seats
in sections of two and accessible end chairs for mobility limited occupants should be provided. See also
WBDG Accessible.
Building codes will provide auditorium seating layout and clearance requirements.

 Special Lighting: Dramatic lighting systems include front lighting, foot lighting, spot lights, follow spot lights, beam lights,
and flood lights, and a projection room/booth with manual and programmable lighting controls, and space for the spot light
operator. Lighting systems should be flexible to accommodate various performance venues (e.g., lectures, plays, musical
performances, etc.) in the Auditorium. See also WBDG Electric Lighting Controls.

 Occupancy: Occupancy Group Classification is Assembly A1 or A3 as per IBC, with sprinkler protected construction, and
GSA Acoustical Class A space requiring special acoustical design. See also WBDG Secure / Safe—Fire Protection.

PRODUCTIVE

 Special Acoustical Design: Quality acoustical characteristics are important in Auditorium spaces so that performances
and presentations can be clearly heard and understood. For performance spaces and general presentation spaces,
recommended noise criteria (NC) rating ranges from NC–20 to NC–30; recommended sound transmission class (STC)
rating ranges from STC 40 to STC 50. Strategies to achieve the recommended NC and STC ranges include, for example:
Type II vinyl wall covering and fabric covered acoustical wall panels for the interior wall finish in the auditorium; Type II
vinyl wall covering for the stage area; Type II vinyl wall coverings for 1/3 of the front of the orchestra (audience) sidewalls
and fabric covered acoustical panels for 2/3 of the back of the orchestra (audience) sidewalls; fabric covered acoustical
panels for rear walls; and a plaster and plywood combination—because of their reverberation characteristics—for the
ceiling. For more information, see WBDG Productive—Provide Comfortable Environments and Acoustic Comfort.
The Auditorium Giovanni Agnelli in Turin, Italy has variable ceiling height according to acoustic needs.
Photo Credits: Centro Congressi Lingotto

SUSTAINABLE

 Increased Cooling Capacity: Heating, ventilating, and air-conditioning (HVAC) systems for Auditorium spaces are sized
and zoned to accommodate varying internal loads, which are a function of audience sizes, performance lighting loads,
and projection equipment. Particularly, air handling units (AHUs) with increased cooling capacity should be zoned
separately for the auditorium, lobby, projection spaces, stage areas, and audience seating areas. Also, the Auditorium
typically has a separate AHU constant volume with modulated temperature control for ventilation. For more information,
see WBDG High-Performance HVAC.

 Materials and Finishes: Use materials and finishes that meet sustainability requirements for Low or No-VOC as well as
durability and low maintenance. Coordinate maintenance and replacements with sustainable O&M practices to ensure an
overall healthy environment.

 Raised Floor: The recommended system for distribution of HVAC in auditorium spaces is ducted supply through floor
vents with ducted ceiling return air vents in auditorium and lobby. In other spaces, ducted ceiling supply with return air
ceiling plenum is recommended. Note that there should be transfer ducts at all acoustically rated partitions.
The historic 1927 Baldwin Auditorium at Duke University underwent renovations while incorporating significant sustainable design features and strategies such as energy and
water efficiency, indoor air quality, and resource management, earning Silver Certification under the LEED™ for New Construction 2.2 Rating System. Pfeiffer Partners
Architects.
Photo Credit: Duke University

SECURE / SAFE

 Fire and Life Safety: Proper notification systems, lighting, and signage are required to facilitate safe and speedy
evacuations during regular events or an emergency in Auditorium spaces. Step lights recessed into floor risers at each
seating tier and wall mounted low light level sconce lights along side walls are typical. Sprinklers should be provided per
code and under stage platforms to suppress fires. Materials used should be non-combustible. Regular inspections should
also be conducted and documented in order to prevent safety hazards. Plan for secure areas in and around the
auditorium including unused parts of the building; separating audience from performers; and keeping unauthorized people
from stage and catwalk areas. Staff should be trained in crowd management, First Aid, and Accessibility in order to
support performers and audience needs and maintain a safe environment. See also WBDG Secure / Safe—Occupant
Safety and Health and Secure / Safe—Fire Protection.

EXAMPLE PROGRAM
The following building program is representative of Auditorium space types.

AUDITORIUM

DESCRIPTION
TENANT OCCUPIABLE AREAS QTY. SF EACH SPACE REQ'D. SUM ACTUAL SF TENANT USABLE FACTOR

Entrance 2,096

Lobby 1 1,500 1,500

Entrance Vestibules 1 96 96

Coat Check 1 150 150

Retail Area 1 200 200

Media Library 1 150 150


DESCRIPTION
TENANT OCCUPIABLE AREAS QTY. SF EACH SPACE REQ'D. SUM ACTUAL SF TENANT USABLE FACTOR

Main Auditorium 4,800

Seating (300 seats) 1 3,600 3,600

Stage 1 1,200 1,200

Support Spaces 1,300

Projection/Control Room 1 300 300

Equipment Storage 1 300 300

Rear Projection Room 1 400 400

Public Toilets (Male 1 120 120

Public Toilets (Female) 1 180 180

Tenant Suite 8,196 8,196 1.1


DESCRIPTION
TENANT OCCUPIABLE AREAS QTY. SF EACH SPACE REQ'D. SUM ACTUAL SF TENANT USABLE FACTOR

Tenant Usable Areas

EXAMPLE PLANS
The following diagram is representative of typical tenant plans.

EXAMPLE CONSTRUCTION CRITERIA


For GSA, the unit costs for Auditorium space types are based on the construction quality and design features in the following table .
This information is based on GSA's benchmark interpretation and could be different for other owners.

RELEVANT CODES AND STANDARDS


The following agencies and organizations have developed codes and standards affecting the design of Auditoriums. Note that the
codes and standards are minimum requirements. Architects, engineers, and consultants should consider exceeding the applicable
requirements whenever possible.

 Americans with Disabilities Act (ADA)


 ASHRAE: Noise and Vibration Control
 Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG)
 GSA PBS-P100 Facilities Standards for the Public Buildings Service
 International Building Code

ADDITIONAL RESOURCES

WBDG

BUILDING TYPES
Educational Facilities, Health Care Facilities, Libraries, Office Building, Research Facilities

DESIGN OBJECTIVES
Productive—Provide Comfortable Environments, Secure / Safe—Fire Protection, Secure / Safe—Occupant Safety and Health

BUILDING COMMISSIONING
Building Commissioning

ORGANIZATIONS AND ASSOCIATIONS

 Acoustical Society of America (ASA)—The Society is primarily a voluntary organization and attracts the interest,
commitment, and service of a large number of professionals. Their contributions in the formation, guidance,
administration, and development of the ASA are largely responsible for its world-wide preeminence in the field of
acoustics.
 Institute of Noise Control Engineering—The Institute of Noise Control Engineering of the USA (INCE/USA) is a non-profit
professional organization incorporated in Washington, DC. A primary purpose of the Institute is to promote engineering
solutions to environmental noise problems.

PUBLICATIONS

 Architectural Graphic Standards, 12th Edition by American Institute of Architects, Dennis J. Hall. New York, NY: John
Wiley & Sons, Inc., 2016.
 Auditorium Acoustics 101 – 104

You might also like