This document compares the CT Analyzer transformer tester to the PCT200i and PCT200Ai transformer testers. The PCT200i and PCT200Ai have improved accuracy over longer current ratios and higher knee voltages compared to the CT Analyzer. Additionally, the PCT200i and PCT200Ai have a color LCD display, larger size and weight, higher power supply wattage, and meet additional EMC standards compared to the CT Analyzer. All three devices measure current ratio, phase displacement, winding resistance and have similar output and environmental specifications.
This document compares the CT Analyzer transformer tester to the PCT200i and PCT200Ai transformer testers. The PCT200i and PCT200Ai have improved accuracy over longer current ratios and higher knee voltages compared to the CT Analyzer. Additionally, the PCT200i and PCT200Ai have a color LCD display, larger size and weight, higher power supply wattage, and meet additional EMC standards compared to the CT Analyzer. All three devices measure current ratio, phase displacement, winding resistance and have similar output and environmental specifications.
This document compares the CT Analyzer transformer tester to the PCT200i and PCT200Ai transformer testers. The PCT200i and PCT200Ai have improved accuracy over longer current ratios and higher knee voltages compared to the CT Analyzer. Additionally, the PCT200i and PCT200Ai have a color LCD display, larger size and weight, higher power supply wattage, and meet additional EMC standards compared to the CT Analyzer. All three devices measure current ratio, phase displacement, winding resistance and have similar output and environmental specifications.
This document compares the CT Analyzer transformer tester to the PCT200i and PCT200Ai transformer testers. The PCT200i and PCT200Ai have improved accuracy over longer current ratios and higher knee voltages compared to the CT Analyzer. Additionally, the PCT200i and PCT200Ai have a color LCD display, larger size and weight, higher power supply wattage, and meet additional EMC standards compared to the CT Analyzer. All three devices measure current ratio, phase displacement, winding resistance and have similar output and environmental specifications.
Comparason Table between CT analyzer and PCT200i/ PCT200Ai
Items CT Analyzer PCT200i PCT200Ai
IEEE C57.13 IEEE C57.13 IEEE C57.13 Standard IEC60044-1/6 IEC60044-1/6 IEC60044-1/6 IEC 61869-2 IEC61869-2 IEC61869-2 Ratio 1 - 2000 0.02 % (typical) / 0.05 % (guaranteed) Ratio 1 - 2000 0.05 % (typical) / 0.1 % (guaranteed) Ratio 1 - 2000 0.02 % (typical) / 0.05 % (guaranteed) Current Ratio 2000 - 5000 0.03 % (typical) / 0.1 % (guaranteed) Ratio 2000 - 5000 0.08 % (typical) / 0.15% (guaranteed) Ratio 2000 - 5000 0.03 % (typical) / 0.1% (guaranteed) Ratio Ratio 5000 - 10000 0.05 % (typical) / 0.2 % (guaranteed) Ratio 5000 - 30000 0.10 % (typical) / 0.2 % (guaranteed) Ratio 5000 - 30000 0.05 % (typical) / 0.2 % (guaranteed) Accuracy Knee Voltage:40000V Knee Voltage: 45000V Knee Voltage: 45000V Phase Resolution 0.1 min Resolution 0.01 min Resolution 0.01 min Displacemen Accuracy 1 min (typical) / 3 min (guaranteed) Accuracy 1 min (typical) / 3 min (guaranteed) Accuracy 1 min (typical) / 2 min (guaranteed) Winding Resolution 1 mΩ Resolution 1 mΩ Resolution 1 mΩ Resistance Accuracy 0.05 % (typical) /0.1 % + 1 mΩ (guaranteed) Accuracy 0.05 % (typical) /0.1 % + 1 mΩ (guaranteed) Accuracy 0.05 % (typical) /0.1 % + 1 mΩ (guaranteed) Output Voltage 0 to 120 Vac Output Voltage 0 to 120 Vac Output Voltage 0 to 120 Vac Output Output Current 0 to 5 A(15 Apeak) Output Current 0 to 5 A(15 Apeak) Output Current 0 to 5 A(15 Apeak) Output Power 0 to 400 VA (1500 VApeak) Output Power 0 to 500 VA (1500 VApeak) Output Power 0 to 500 VA (1500 VApeak) OperatingTemperature:-10 °C up to + 50 °C OperatingTemperature:-10 °C up to + 50 °C OperatingTemperature:-10 °C up to + 50 °C Environment Storage Temperature -25 °C up to + 70 °C / Storage Temperature -25 °C up to + 70 °C / Storage Temperature -25 °C up to + 70 °C / Conditions Humidity Relative humidity 5% up to 95% not condensing Humidity Relative humidity <90% not condensing Humidity Relative humidity <90% not condensing Physical Size (W x H x D) 360 x 285 x 145 mm Size (W x H x D) 470 x 200 x 245 mm Size (W x H x D) 470 x 200 x 245 mm Dimensions Weight 8 kg Weight 11kg Weight 11kg Display Gray LCD Color LCD 8.4inch, based on Windows XP Color LCD 8.4inch, based on Windows XP Input Voltage 100 Vac to 240 Vac Input Voltage 110 Vac to 240 Vac Input Voltage 110 Vac to 240 Vac Permissible Input Voltage 85 Vac to 264 Vac Permissible Input Voltage 90 Vac to 260 Vac Permissible Input Voltage 90 Vac to 260 Vac Power Frequency 50 / 60 Hz Frequency 50 / 60 Hz Frequency 50 / 60 Hz Supply Permissible Frequency 45 Hz to 65 Hz Permissible Frequency 45 Hz to 65 Hz Permissible Frequency 45 Hz to 65 Hz Input Power 500 VA Input Power 600 VA Input Power 600 VA The product adheres to the EMC electromagnetic compatibility (EMC) Directive IEC60255-27:2005 IEC60255-27:2005 2004/108/EC (CE conform) IEC61000-4-18:2010 IEC61000-4-18:2010 International IEC 61326-1 Class A EMC- IEC61000-4-5:2005 IEC61000-4-5:2005 Europe EN 61326-1 Class A Emission IEC61000-4-4:2004 IEC61000-4-4:2004 USA FCC Subpart B of Part 15 Class A IEC61000-4-3:2010 IEC61000-4-3:2010 International IEC 61326-1 IEC61000-4-2:2008 IEC61000-4-2:2008 EMC- Europe EN 61326-1 IEC61000-6-4:2006 IEC61000-6-4:2006 Immunity Safety The product adheres to the low voltage Directive 2006 / 95 / EC (CE conform)