Project Anas villa REINFORCED CONCRETE COUNCIL

Client 0 Made by Date Page


Location Columns F /3,4 CORNER rmw 15-Oct-2012 33
PUNCHING SHEAR to BS8110:1997 COLUMN Checked Revision Job No
Originated from RCC13.xls v2.2 on CD © 1999-2003 BCA for RCC chg - R68

MATERIALS fcu N/mm2 40 STATUS Legend


fyv N/mm2 460 VALID DESIGN
link Ø mm 8

DIMENSIONS A mm 400 E mm 0
B mm 400 F mm 0
C mm 150 G mm 0
D mm 150 H mm 0

LOADING Vt kN 155.0 0 0 350


ult UDL kN/m2 20.00

SLAB h mm 300 dx mm 265 Asx mm2/m 2065


dy mm 245 Asy mm2/m 2065
ave d mm 255 ave As % 0.811
2
RESULTS Veff = 193.8 kN vc = 0.7715 N/mm (Table 3.8)
2 2
At hole face, vmax = 0.676 N/mm At 1.5d perimeter, v = 0.3617 N/mm
2
At 0d perimeter, v = 0.2830 N/mm

PROVIDE LINKS 0 Links not required