Professional Documents
Culture Documents
Plumbing Code (Sample Questions) R
Plumbing Code (Sample Questions) R
.....
'·
PLUMBING
CODE
(Sample Questions)
-
$-'~
~
-
=--
· ..,.~~ (02) 7414096
09175353343 0917535334~~u
~ jpluforials101@gmail.com · <~:;. 0
/ · Ii :lptJ~ials
. .
i~.'-'
\)
.. .
Q
. .
. ..
-:·~;r~.- ~
.~ ....;:!' . :
.. ~
~ ~ ~
I /0
I I
. )
I
PLUMBING CODE SAMPLE QUESTIONS
I
INSTRUCTION: Select the correct answer for each of the following quest~ons. Mark only one answer
I for each item by encircling the letter of your choice. STRlCTL Y 0 ERASURES ALLOWED.
M ULTIPLE CHOICES:
I PART!
I. A vertical vent tha1 is a contihuatio n of the drain to which it connects?
a. branch vent G" continuous v~
I h. reiiefvcnt ci. ci rcuit vent
2. a piping system designed to control and conveys excess ground water to a suitable location
I a. stonn water drainage piping
b. sewer piping
I c. vertical stack
d. downspout
I 3. When no public sewer intended to serve any lot or premises is available in any thoroughfare or
right of way abutting such a lot or premises, drainage piping from the building shall be connected
to:
I a. Sewage ejector
b. holding tank
c. private sewage disposal system
I d. cesspool
4. A unit which is equivalent to the flow rate of one (I) cubic foot of water per minute or 7 Yi gpm
I of water is?
a. F.U. b. number of water closet English unit d. metric unit
1
I PLUM BING CODE SAMPLE QUESTIONS
I d. Zoning administrator
I I. A 11 water su pply, drainage, venting system and all fixtures and their traps complete with their
I connection.
a. plumbing system
b. piping system
I c. sewer system
d . zoning admihistrator
e.
12. The minimum diameter size of water supply pipe to a lavatory is:
a. l inch
b. 2 /4 inch
c. 3/8 inch
d. Yi inch
I 13. Request fo r inspection by the master plumber to the administrative authority is required to be made in
advance at least before the work to be tested.
I a.
b.
12 hours
24 hours
c. 36 hours
I d. 8 hours
l 4. The vertical distance that waste travels through open air between the waste pipe and the indirect waste
receptoi is?
f ~- ro11nec1 i0n
b. air gap drainage
c. convcya11~c
d. vacuum
f . 15. A means of measurement for vertical waster or soil stack. It is equal to each floor level or storey in a
building but are always at least eight ft intervals
2
PLUMBING CODE SAMPLE QUESTIONS
1
a. vertical distance
b. floor distance
c. branch intervals
r
d. storey
16. A drain connecting the compartments of a certain fixture to its trap is called.
a. combination waste and vent
l b. continuous waste
c. special waste
d. indirect waste
19. The minimum pressure that shou ld be maintained for fixtures containing flush tank s upplies shall
a. 8 psi
b. 4.34 psi
c. 30 psi
d.434 psi
20. A piece of chemical fitted under another piece of flat metal or wood over which tyater is eime~ted_to
run is called:
a. gutter
b. sheeting
c. flashing
d. roofing
3
I
PLUMBING CODE SAMPLF. QUESTI ONS
l
22. When connecting plastic pipe to other types of piping, the specific transition intended shal l be made
l with approved:
a. soldered joint
b. threaded joint
r @ttings and adaptors
d. sweated joints
l 23. The inspection of a gas piping system prior to covering or concealing such pipe is called a
a. routine inspection
b. hydro piping inspection
c. site inspection
@ough piping inspection .r
24. Copper tubing used for water piping under concrete slabs within a building shall be
(?.)opper tube with brazed
I c. 12 gal/min
(!)to gal/min
r 27. Vent pipes may offset horizontally when the distance above the extreme overflow level of the fixture
is at least
a. l inch
®.inches ·
c. 18 inches
d. I ft
28. The min imum plumb ing permit charge for one unit is
a. 15.00
b. 5.00
c. 10.00
4
I
PLUMBING CODE SAMPLE QUESTIONS
I
d. 7.00
l 29. A drainage pipe used to carry main of surface water, cooling waler and similar liquid waste is
a. house drain
I b. house sewer
c. sanitary sewer
d. storm sewer
l 30. Expansion join ls shal l be acceptable <::xccpt in piping for
(b;ents
b. hot water
c. steam
d. cold water
31. A receptacle attached to the plumbing system other than the trap in which or waste may collected or
retained for an ultimate discharge into the plumbing system .
a. container
©xture
c. tank
d. cold water
.. 32. Cast iron piping in I0 ft lengths installed horizontally, shall be supported at intervals of not more than
a. 12ft
b. I 5 ft
05 ft
d. I 0 ft
33. Sizes of vertical and horizontal drainage pipes shall be determined from
a. type of building
b. number of bathroom installed
c. location of fixtures
@>tal fixture units
34. The valve for controll ing which has gradual and regular variation over time and space is called
@aminar flow
b. streamline '
c. turbulent
d. mixed flow
35. The valve for controlling two or more outlet, is a cold water supply line may be a.
liiising stem gate valve
'-(heavy duty glove valve
c. ground key va lve
d. non rising stem globe valve
5
PLUMBING CODE SAMPLE QUESTIONS
·r
I_
36. The minimum s ize building supply by the code for water is
© inch >- ~ If ~eNr'ue,f
b. I inch
c. \12 inch 0
d. I Y. inch
37. According to the existin g Plumhing Code casr iron pipes. wrought iron pipes, weld steel pipes. copper
pipes, vitrili cd c lay, concrete and asbestos pipes shall conform to the standard other than the Philippine
standard.
a. ANSI
b. AISC
c. ASTM
d. APJ
38. A material not listed in the code for use in water piping is
@tum in um
;@isbestos cement
c. cast iron
d. plastic
39. The critical level marking o r a backtlow prevention device or vacuum breaker is a point established
by the
0testing laboratory
b. health officer
c. inspector
d. manufacturer
40. CPVC water pipe may be used for hot an cold water distribution systems
a. above ground only
b.below ground only
c. in residences only
d. within the building
41. Plugging an opening horizontal drain line with another horizontal drain line, the acceptable fitt ing to
be used are
a. calking
b. filling
c. compressing
d. compacting
42. When connecting horizontal drain line with another horizontal drain line, the acceptable fitting to be
used are
-2
6
_)_
__)
I
PLUMBING CODE SAMPLE QUESTIONS
I
a. coupling
I b. cross tee
c. combination y and I/8
d. sanitary tee
43. The minimum allowable s i.le or any building drain, horizontal branch, vertical soil or waste stack
serving one or more waste closets shall be
I a. 4"
b. 4 Y2"
01"
I d. 5"
I 44. it is a box like collection device which is located on the exterior of the building and receives storm
water on one side
a. scupper
I ~utter
c. storm drain
d. roof dra in
I 45. The air pressure test for any threaded (low pressure) gas piping system shall be atleast
a. 10 psi for 15 min
I (~)i 5 ps i for J 5 min
c. 15 psi for 10 min
d. JO psi for JO min
I 46. Ca lked or screwed joints shall be applicable to
I a. PVC
@ast iron
c. vitrified clay
I d. asbestos
47. Th~t pipe serving a combination waste and vent system with a 4 inch drainpipe shall be atleast
I ~.G ~"
b. 3 W' .
c. 3"
@)"
48. Building sewers shall be tested by completely filling the sewer with water from the
a. lowest to at least I 0 ft ahead
( 91owest to the highest po int
c. lowest to at least ground level
d. lowest to at least 5 ft ahead
49. In water supply piping slip joints may be used only on the
7
PLUMBING CODE SA MPLE Q UESTIONS
51. the drainage pipe running from outside a buildings foundation to the main sewer is called
a. building drain
b. sewer
c. waste drain
d. storm drain
52. A set of regulation adapted by an administrative agency that has jurisdiction over materials and design
specification in plumbing
g1umbing code
b. code of ethics
c. building code
d. civil code
53. The maximum lead content allowed in pipe used to convey potable water
a. 3 % '
b. 2%
c. 1%
c9%
54. Minimum size of water supply pipe for flush valve is
a. 2"
(9t"
c. :y.. ..
d. Yi"
55. The lowest piping system that receives the discharge from soil waste and other drainage pipe
a. waste pipe
~ buildi.ng drain
c. building sewer
d. soil pipe
8
I
PLUMBING CODE SAMPLE QUESTIONS
I 56. Is it permissible to place building sewer and drainage piping in the same trench with the water service,
I pipe?
~:'
I c. maybe yes
d. sometimes, yes
I 57. Upon issuance of plumbing permit. plumbing installation shall commence within
a. no limit
b. one month
I @one year
d. six months
I 0,all-cock
c. butterfly valve
d. gate valve
b. sto rm sewer
I 0twv system
d. vent system
I 61. That part of the plumbing system extending from a point 4 or 5 ft from the inner face of the
foundation wall of a building to the junction with another sewer
a. house sewer
I b. storm sewer
c. sanitary sewer
d. sewer P!Pe
I
62. Equipment which includes all valves and controls used in plumbing system are required to be
accessible or readily accessible is called
a. machines
b. controls
9
PLUMBING CODE SA MPLE QUESTIONS
c. regulating equipment
I
A
d pipes
63. Rain water piping located on the exterior of a building using galvanized sheet metal shall not be less
than
a. 25 ga
b. 32 ga
c.2 8 ga ~
d. 30 ga U
64. A term used which is contrary to sanitary principles o r injurious to health is
a. insanitary
b. unhealthy
c. healthful
d. sanitary
65. An electricity or mechanically operated device used to elevate sewage and liquid waste from a lower
level to appoint of discharge into a sewer or other disposal system
a. ejector
b. ram
c. screw
d. hard pump
66. The maximum fixture units loading allowed on a 2 inch waste stack
a. four
b. six
c. sixteen
d. eight
10
l
PLUMBING CODE SAMPLE QUEST IONS
l
c. extra ordinary sink
I d. bedpan washer
70. Building sewer or drainage pipe shall be placed with the same trench with water service pipe.
I a. false
b. not same
c. maybe
l d. true
71. A measure of inertia forces to viscous forces, which sometimes describe whether it is turbulent or
t: laminar flow is
a. Reynolds number
r b. Froude number
c. Moody number
d. weber number
[ 72. A device used to connect drainage of a dishwasher with the sanitary drainage system is cal led
73. A pipe which makes an angle of 45 degrees from the vertical is considered?
I a. horizontal
b. cracked
I c. vertical
d. offset
I c. 7 gals
(3· 2 gals
I 75. Changes in direction at copper tubing maybe made with
a. bending equipment
b. metallic fittings
I c. plastic fittings
d. prepare torch
76. That part of the lowest horizontal piping of the plumbing which receives the d ischarge from soil,
waste and other drainage pipes inside of the building and conveys it to the house sewer.
11
PLUMBING CO DE SA MPLE QUEST IONS
a. vertical drain
b. storm drain
[· c. house drain
d. soil pipe
77. Piping which shall not be installed under o r within 2 ft at any building or structure
(?);ast iron
b. plastic
c. copper
d. asbestos cement
r
78. Fixtures connections between drainage pipes and water closets shall be made with
a. hot poured compound
I b. flanges
c. expansion joints
I d. unions
79. A joint made by finnly packing with oakum and filled with molten lead to a depth of not less than I
l inch, is for
a. cast iron bell and spigot soil pipe
b. cast iron no hub pipe
( c. plastic pipe
d. steel pipe
l 80. The distance between a water heater and the union on the water lines shall not be more than
MB"
~2"
c. 6"
d.24"
[ 81. What valve is required ahead of each water supplied appliance, each slip joints or non-metallic
connection?
a. flow valve
b. check valve
c. control valve
d. solenoid valve
82. When pipe m~es an angle of not more than 45 degrees with tbe vertical, it is considered as:
a. vertical pipe
b. crooked pipe
c . diagonal pipe
d. horizontal pipe
12
I
PLUMBING CODE SAMPLE QUEST IONS
I
83. Total number of water closets on a 3 inch stack is
I a. six
b. three
c. four
I cl.two
84. A vent in a combustion waste and vent system shall be approximately equal in area to one half
I a. area o f the ho use sewer
b. cross section a rea of the draw piµe
c. area of the p ublic sewer
I d. diameter of the draw pipe served
I 86. Every passage way to attic water heater shall have a solid continuous flooring not less than
a. 36" wide
b. 48" wide
I c. 60" wide
d. 24" wide
87. Every building in which plumbing fixtures are installed shall have a connection to a
I a. Deywell
b. cesspool
c. storm water
I d. public or private sewer
I 88. Allowing for friction and other pressure lose the available water pressure for fixture is
a. 30 psi
b. 20 psi
I c. 15 psi
d. 45 ps i
90. The movement of water through the surface of a soil and into the soi l below the surface is
a. storm meter run off
13
I
PLUMBING CODE SAMPLE QUESTI ONS
I
b. depression
I c. evaporation
d. infiltration
I 91. The minimum slope of3" horizontal pipe shall be not less than
a. 3/.s ·• /slope
b. Y2 ·•I slope
I c. I" IA:
d. W' I ft
I 92. The size of the supple piping outlet for any gas appliance shall not be less than
a. the smallest size pipe in the system
I 93. The quantity of water required to be supplied to every plumbing fixture shall be represented by
a. pounds per sq. inch
I d. cistern
I a. 5 ft head
b. 10 psi
c. 25 psi
l d. I 0 ft head
96. a fixture vent pipe increased one pipe size its entire length
t
@ay exceed the maximum horizontal length limited by code
• b. will be a better workmanship job
c. will inc~ease venting efficiency
d. will reduce the cost of installation
14
I
P LUM BING CODE SAMP LE QUESTIONS
I a. 5
b. IS
c. 12
I ct. 10
99. The minimum size clean out allowed to serve a 4" drain line
I a. 3 Yi"
b. 2"
c. 3 ..
I d. 4"
I 00. A storm drain sometimes located under the basement floor with in the walls of the
I a. inside storm drain
b. house sewer
I I. U pvc
I 2. UL
I 3. IAPMO
4. CCIP
I
5. ISO
I
6. NAMPAP
( =
15
I
PLUMB ING CODE SAMPLE QUEST IONS
I
7. MWSS ,
I 8. PAGA@
I 9. PSME
=
I JO. PNS
I 11. L
=
I 12. ASTM
=
I 13. ABS
I 14. HOPE
=
I 15. PPR
I 16. PSSE
I 17. ANSI
18. NFPA
I
19. VSTR
I
20. PDJ
r
21. POI
I 22. GIP
=
r
r 16
·'
I
PLUMBING CODE SAMPLE QUESTIONS
I
23. DWY
I 24. CPYC
=
I 25. G?M
=
=
I 26. XH
=
I 27. RCP
I 28. VTR
=
I 29. DFU
I 30. PD!
=
I 31. EMT
I 32. HVAC
33. JPS
I
34. NEM A
l =
35. PPM
l
36. PRY
[
37. TDH
17
I
PLUMBING CODE SAMPLE QUESTIONS
I I. A vertical length of soi l or waste at eight feet in height, within which horizontal branches from one
I c. branch interval
d. horizontal soil or waste branch
I 2. The top edge of a plumbing fixtu re or receptacle from wh ich water overflows
a. rim level
b. flood level rim
I c. flood level
d. overflow edge
I 3. A type of urinal in which the bowl is elongated and attached to the floor. A front piece conceals the
internal elements of the urinal located at the part of it
I d.trough urinal
4. The vertical distance between the top dip and the crown weir
I a. trap seal
b. water seal
c. dry seal
I d. invert elevation
S. Disposal of sewage, human excreta or other waste waters shall be done through an approved
l _ _ __ _ and storm drainage system.
a. cesspool
b. excreta
6. Horizontal drainage pipe shall have slope of not less than 20 mm/m or _ _ toward the point of
disposal except for the ff reasons :
I. excessive depth of the proposed drainage line
2. structural or geological feat ures of the terrain
3. exixting adverse arrangement of the building or structure.
a. 1%
b. 2%
c. 3%
d.4%
18
I
PLUMBING CODE SAMPLE QUESTIONS
I
I 7.
a.
Piping _mm or larger in dia may have a slope of 1%
152
b. 127
I c.
d.
114
102
I 8. Changes in direction of drainage piping shall be 22 Vi deg bend ; 45 and 60 deg bend or other approved
fittings of _ _ sweeps.
r~. longer
I b. longer radius
c. smooth bend o
I d. right angle
I a.
b.
water supply
Storm/Drainage system
c. Electrical System
I d. Vent System
I 11. What is the distance of the septic tan from any source of water supply?
a. 5 meters
@5 meters ~ f~ ~
tJ
l c. 20 meters
d. 25 meters ---;> ~f-ci-0'~ ~
~Omm
r c. 50 mm
d. 150 mm
r 13. What is the mfnimum distance of sewer lines form water Jines?
@_p.30m
b. 0.60 m
C. 15 m
d. 25 m
19
I
PLUMBING CODE SAMPLE QUESTIONS
I
I 14. DWV stands for?
a. Drainage water vent
b. drainage waste vent
I J 5. The administrative authority req uires that every request for inspection be filed at least how many
days/hours before such inspection is intended?
a. 3 calendar days
I b. 72 hours
c. 3 working days
d. none of the above
I 16. A metallic sleeve, caulked or joined to an opening in a pipe, into which the plug is screwed that can be
I c. coupling
d. bushing
I 17. The plugging of an oakum, lead o r other materials that are pounded into the annular space.
a. plugging
b. caulking
I c. cementing
d. soldering
18. The unobstructed vertical distance through the free atmosphere between the lowest opening from any
pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of the
receptacle.
a. air break
b. air vnccum
c air gap
d. development length
19. The flow of water or other liquids, mixtures, or substances into the d istributing pipes of potable
supply of water from any source or sources other than its intended source
a. back pressure backflow
b. vaccum flow ·
c. backflow
d. back pressure
20
I
PLUMBING CODE SAMPLE QUESTIONS
I
a. I
I b.2
c 1/2
d.3
I 21. A flange that closes the end of the pipe where there is no opening for the passage of water.
a. blind flange
I b. blank flange
c. dead ena flange
d. plug
I 22. A controlled outlet on a pipeline used to discharge water
I a. orifice
b. blow-off
c. riser
I d. overflow
23. What is the general term applied to any vertical line of soil, waste or vent piping?
I a. stack pipe
b. soil pipe
c. wet pipe
I d. waste pipe
I 24. What vent as terminal of other forms of ventilation and is installed to maintain a balanced atmospheric
pressure in the waste pipe and fixture traps?
a. wet vent
I b. waste vent
c. main vent
d. unit vent
I 25. How many gallon per water are there in one cubic foot of water?
a. 7.48 gals
'
b. I 0.20 gals
c. 8.33 gals
d. 9.80 gals
r
26. The fitting used to close the end of the pipe.
a. cover
b. plug
c.cap
d. cleanout cover
27. The fitting which is used in conn~cting the male end of a pipe to a titting of a larger size
I •
21
I
PLUMBING CO DE SAMPLE QUESTIONS
I
a. bushing
I @lange
c union
d. nipple
I 28. The recommended distance from the bottom of the water tank that the dip tube of cold water supply
should terminate.
I a. 20 cm
0?J5cm
c. 30 cm
I d. 35 cm
I 31. That pipe or shaft which is used to remove foul or congested air from a fixture or room and conveys
the same to the atmosphere.
a. stack vent
I b. relief vent
c. ·local vent
d. ventilating vent
I 32. On large plumbing installations, water tests are applied progressively where the low end of the line is
plugged and filled with water. Wh;:it is the min pressure that should be applied?
a. 2 psi
b. 3 psi
c. 5 psi
d. I psi
33. In making an air test to the plumbing installation, (after closing all the openings with testing plugs)
what is the pressure applied as indicated on the mercury gauge?
a. 2 psi
b. 3 psi
c. 5 psi
d. I psi
34. What is the portion of the water system piping which is suspended from the basement ceiling and to
which are connected with branches that serve the fixture?
a. house water supply
b. basement supply main
22
I
PLUMBING CODE SAMPLE QUESTIONS
I c. water main
i d. fixture supply
35. What is that portion of the water system piping which furnishes the fixture installed on the various
I 36. What kind of vent usually e mployed where only relatively clean water flows through the vent pipe
and where the simultaneous use of fixtu res in a battery of fixtures before a c ircuit and loop vents are
I employed?
a. 7
b. 8. ------;) !N'-6'-X
I c. 9
d. 10
I 37. Intervals for support for cast iro~ ~ipe should not exceed_ _
a. 5 feet ..,._hb..,.;~
b. 7.5 feet
l c. I 0 feet
d. 12 feet
l 0
38. What will prevent the passage of odor, gasses and verm in form the common sewer into the drainage
system within the building?
a. Main drain trap
b. grease trap
c. p-trap
d. building sewer
39. What fixture u:;ually taken as a fixtu re unit in determining the size of soil or waste pipes.
a. lavatory
b. urinal
c. kitchen sink
d. water closet
40. The minimum size of a house sewer no t carrying human excrement and installed under ground?
a. 2 inches
b. 3 inches
c. 4 inches
d. 6 inches
23
I
PLUMBING CODE SAM PLE QUESTI ONS
I 41. The minimum size or a house sewer carrying human excrement and installed underground?
I a. 2 inches
b. 3 inches
c. 4 inches
I d. 6 inches
42. The minimum size o f a so il stack?
a. 2 inches
I b. 3 inches
c. 4 inches
d. 6 inches
I 43. The minimum size of a water riser?
a. 2 inches
I b. 3 inches
c. 4 inches
d. 6 inches
I 44. The minimum distance of the inlet to the bottom of the sump pit?
I a. 2 inches
b. 3 inches
c. 4 inches /bi>'-1-1
I d. 6 inches
l c. wall hung
d. elongated bowl type
l 47. The minimum distance between two urinals according to the code?
a. 750 mm
b. 375 mm
c. 300 mm
' d. 600 mm
48. The minimum distance between two urinals according to the code?
a. 750 mm
24
PLUMBING CODE SAMPLE QUESTIONS
t b. 375·mm
i c. 300 mm
d. 600 mm
I 49. In the conduct of water test for plumbing installations, the pipe will be subjected to _ _ pressure for
15 minutes before inspection.
a. 5 meters
I b. 15 psi
c. 5 psi
d. 7 psi
I 50. In water supply installation, where should the hot water lines/ valves located?
a. left
I b. right
c. both a & b
d. no~e of the choices above
I 51. The minimum air gap?
I a. 38 mm
b. 25 mm
c. 13 mm
I d. 50 mm
52. In laying water pipelines underground, provisions fo r the minimum allowable distance were stipulated
l by the code. What is the minimum distance of the water lines with respect to the sewer lines parallel to
the water line?
a. 1.5 m
t b. 1.2 m
c. 0.30 m
d. 0.75 m
25
I
PLUMBTNG CODE SAMPLE QUESTIONS
I a.
b.
150 mm
200 mm
. c. 100 mm
I d. 250 mm
I a. every 5 m
b. every 15 m
c. every 10 m
I d. every 20 m
57. DWV
I a. Drainage
b. Drainage
Waste Vent
Water Vent
I c. Drainage
d. Drainage
Waste Vortex
Window Vent
I 58. ASTM
a. American standard for testing materials
b. American society for testing and materials
I c. American
d. American
standard for testing and materials
society for testing materials
I 59. A WWA
a. American waterworks administration
b. American waterworks ;issociation
r c. American waterv1orks agency
d. American waterworks authority
60. The minimum pressure that should be maintained in a tlushometer valve according to the code.
a. 5 psi
b. 8 psi
c. I 0 psi
d. 15 psi
61. The minimum pressure that should be maintained in a flush tank according to the code?
a. 5 psi
b. 8 psi
c. 10 psi
d. 15 psi
26
• PLUMBING CODE SAMPLE Q UESTIONS
I a. percolation test
I b. adsorption test
c. penneability test
d . cohesion test
I 64. What is the width of the spacer inside the neoprene gasket where fittings or pipe ends meet?
a. 3/32 inch
I h 3/8 inch
c. 5i32 inch
d. 518 inch
I 65. Disposal of sewage, human excreta or other waste waters s hall be done through an approved and
stonn drainage system.
I a. cesspool
b. excreta
I c. digestive chamber
d. leaching tank
I 66. No fitting shall have more than_ inlet at the same level shall be used unless the discharge from one
inlet cannot readily enter into the other inlet .
a. three
I b. two
c.one
d. four
I 67. Horizontal drainage shall enter through_ deg wye branches, combination wye and 1/ 8 bend branches
or other approved fittings of longer sweeps.
I a. 90
b.60
t c.45
d.30
68. Vertical drainage lines to horizontal drainage line shall enter through_ deg branches.
a.90
b.60
c.45
d.30
69. 60 deg branches of offsets may be used only when installed in a _vertical position.
a. rigid
b. straight
c. well supported
d. true
27
I
PLUMBING CODE SAMPLE QUESTIONS
I
I 70. Wastes detriments! to the public sewer shall be_ _ and disposed as found necessary.
a. vented
b. treated
c. drained to soi I
d. prevented
I 71 . Sewage which may be deleterious to su rface or suhsurface waters, shall not be ___ into the ground or
into any waterway unless not treated to an acceptable fom1.
a. collected
I b. absorbed
c. discharge
I d. conveyed
72. No drain or vent piping shall be drilled and tapped for making connections thereto, and no cast iron
b. c loset ring
c. closet bowl
d. closet trap
74. No vent pipe shall be used as soil or waste pipe, nor shall any soil or waste pipe be used as a vent.
Single drainage venting system with_ branch lines are prohibited.
I a. crooked
b. three
c. unvented
d. double offset
75. The enlargement of a __ mm closet bend or stub to I 02 mm dia shall not be considered as an
obstruction to flow of water, sewage or air.
a. 63
b. SI
c. 76
d. 89
76. All piping passing under or through walls shall be protected from breakage with embedded metal
pipe_.
28
I
PLUMBING CODE SAMPLE QUESTIONS
I
a. chase
I b. ring
c. sleeve
d. tube
I 77. All piping passing through or under cinders or other corrosive materials shall be protected by encasing
with sheath.
I a. plastic
b. rubber
c. polyethylene
I d. polybutylene
I 78. Void between pipes and sleeves through concrete floors in the ground shall be appropriately sealed
with
a. bitumen
! b. lead
c. epoxy
d. grout
I 79. The bottom of all pipe trenches deeper than the footing of any adjacent building o r structure and
parallel to it must be at least_ _ degrees there from.
I a. 90
b.30
c. 60
I d.45
! 80. No building sewer or other drainage piping or part thereof, shall be installed under or within 0.60
meter of any building or structure, nor less than _ _ meter below the finish ground surface.
a. 0.50
( b. 0.30
c. 0.40
d. 0.20
[
81 . Cast iron soil pipe bell spigot and hub less pipe shall be supported at or closer.
a. 2.4 m
b. every storey
c. 2.80 m
d. 2.0 m
82. Screwed pipe - iron pipe size shall be supported not less than _ _ other storey height.
a. every
b. one and a half of every
c. one half of every
29
I
PLUMBING CODE SAMPLE QUESTIONS
I
d. three fourth of every
I 83. Cooper tubing shall be supported at each storey or at maximum intervals o f _ meters on center.
a. 2
I b. 4
c. 3
d. 5
I 84. Lead pipe shall be supported at intervals not exceeding_ meters at centers with a rigid vertical back
up.
I a. 1.2
b. 1.5
c. 2.4
I d. 1.8
I c. 2.4
d. I .8
I 86. Cast iron pipe - where joints occur, it shall be supported at not more than 1.5 meters interval except
that pipe exceeding 1.5 m length may be supported at not more than _ _ meters.
a. 2
I b.3
c. 2.8
d. 2.4
87. Plastic tube shall be supported by stiff metal or wood backing with hangers in its entire length for
small size tubing up to _ mm dia.
a. 38 mm
b. 32 mm
c. 51 mm
d. 64 mm
88. Faucets and diverters shall be connected to the hot and cold water distribution supplies so that the hot
water supply is located at side of the combination settings.
a. right
b. left
c. rear
d. bottom
30
PLUMBING CODE SAMPLE QUESTIONS
89. It consists of a loaded air inlet valve, an internally loaded check valve, two properly located test cocks
and 2 isolation valves.
a. pressure breaker
b. pressure vacuum breaker backflow prevention
I 90. Consist of two independently acting internally loaded check valve, two properly located test cocks
and 2 isolation gate valves.
a. pressure breaker
I b. pressure vacuum breaker backflow prevention
c. pressurized isolation valves
d. double check valves
I 91. What is the minimum air gaps for water distribution when affected by sidewalls for lavatories and
I c.42
d.48
I 92. What is the minimum air gaps for sinks, laundry trays, gooseneck bath faucets and other fixtures with
effective opening not greater than 19 mm in diameter when not affected by sidewalls.
I a.51
b.38
c.42
d.48
; 93. for over rim bath fillers and other fixtures with effective opening not greater than 25 mm in diameter
when not affected by sidewalls.
a. 51
I b.38
c. 42
d.48
I 94. When affected by sidewalls?
a. 51
b.38
c.42
d.48
31
I
PLUMBING CODE SAMPLE Q UEST IONS
I 95. What is the minimum air gap fo r water distribution with effective openings not greater than 25 mm in
I 97. Air gaps less than 25 mm shall only be approved as permanent part of a listed assembly that has been
tested under actual backflow conditions with vacuum from 0 - _ _ of mercury.
a. 63.5
I b. 36.5
c. 65.3
I d. 35.6
98 . Atmospheric vacuum breaker is installed in an upright posit ion. What is the minimum distance above
all downstream piping and flood level rim of receptor?
a. 300 mm
b. 200 mm
I c. 250 mm
d. 150 mm
99. Access and clearance s hall be provided for the required testing maintenance and repair. Access and
clearance shall require minimum o f _ mm space between the lowest portion of the assembly and the
grade, floor and platform.
a. 305 mm
b. 350 mm
c. 205 mm
d . 250 mm
100. Installations elevated more than _ _ meters above the floor or grade shall be provided with a
permanent platform capable of supporting a tester or maintenance person.
a. 2.51
b. 2.15
c. 1.52
d. 1.25
32
I
PLUMBING CODE SAMPLE QUESTIONS
I
I I. An alley is any public space, public park or thoroughfare less than _ _ meters but not less than 2
meters in width dedicated or deeded for public use.
I a. four
b. five
c. three
I d. six
2. Occurs to an increased reverse pressure above the supply pressure. This may be due to pumps, boilers,
I gravity and other source of pressure.
a. reverse pressure
. b. backpressure backflow
I ~r~re~
a. pressure drop
I 3. A type of pipe connection in which a ball shaped end is held in a cuplike shell and allows movements
in evry direction.
I a. ball joint
b. ball coupling
c. ball connection
I d. ball socket
I c. stack vent
d. branch vent
r 6. A fitting screwed or caulked over the end of a pipe for closing the pipe end.
a. cap
b. cleanout
c. spigot
d. blank flange
7 . After caulking, the finished joint shall not extend more than_ mm below the rim of the tub.
a. 2.4
33
L
PLUMBfNG CODE SAMPLE QUESTIONS
[
b. 3.2
T· c. 1.5
l d . 2.3
8. Plastic pipe and fittings designed to be joined by solvent cementing shall comply with appropriate
installation standards.
a. a. lAPMO
b. PC
c. NBC
d. Sanitation Code
I 9. Neoprene rubber s hall be used in soils subject to _ _ __ _
a. Pollution
r b.
c.
d.
Oil intrusion
Contamination
Erosion
JO. Joints with thin walled copper tubing to thick walled threaded pipe s hall be made by the use of
adaptor fittings.
a. Brass
r b. Copper
c. Galvanized iron
d. Cast iron
11. T he joints between the copper tubing and the fittings sha ll be properly sweated or soldered or made
with flared and screw ends adaptor fittings, the connectio n between the threaded pipe and the fitting made
with a standard pipe size_joint.
a. Flange
b. Slip
c. Screw
d. Welded
12. Approved unions may be used in drainage work when accessibly located in the trap seal or between a
fixtu re and its trap in the vent system except _ _ or in wet vents, at accessible joints in the water supply
piping system and in gas piping.
a. Dry vent
b. Air vent
c. Soil pipe
d. Undergro~nd
13. Brass or copper ground joint, flared on ferrule type connections w hen made up shall not be considered
as _ joints.
a. Flange
b. S lip
34
I
PLUMBING CODE SAMPLE QUESTIONS
I c. Screw
i d. Welded
14 . No fitting or connection that offers abnormal obstruction to flow shal l be used. The enlargement of
1 c. 76
d. 102
I 15. Brass or cast iron body cleanouts shall not be used as a _ _ or adpter.
a. Reducer
b. Enlarger
I c.
d.
Fitting
Union
I 16. Type _ _ copper tubing may be used for water piping when piping is above ground inside or a top of
a bldg, or underground outside of structures with outside protective coating.
I a. K
b. L
c. M
I d. N
17. Copper tube shall not be used for piping carrying chemical or industrial wastes. Copper tube for water
I supply piping shall have a weight of not less than type_./
a. K
b. L
I c.
d.
M
N
I 18. Copper tubing shall be marked by means of a continuous and indelibly colored stripe at least_ mm
in width.
a.
r b.
6.4
7.2
c. 7.6
r d. 6.8
35
I
PLUMBING CODE SAMPLE QUESTIONS
I a. Blue
b. Green
c. Yellow
d. Red
I a. Blue
b. Green
c. Yellow
I d. Red
22. Closet ring or closet flange shall be approx. _ _ mm in diameter and when installed shall together
I with the soil pipe, present a 38 mm wide flange and a groove face to receive the fixture gasket or ball
wax.
a. 178
I b. 152
c. 302
I d. 104
23. Caulked - on closet ring or closet flanges shall not be less than_ mm thich and not less than 51 mm
I in overall depth.
a. 7.2
b. 6.4
I c. 5.4
d. 3.4
I 24. Gate valves, when used in drainage work, shall be the full way type with working parts of corrosion
resistant metal. Sizes _ _ mm or larger in dia shall have a cast iron bodies.
I a. 102
b. 104
c. 106
d. 108
25. Valves up to and including _ mm in sie shall be all brass or bronze metal.
a. 102
b. 64
c. 51
d. 42
26. A t SI
a. American National Standards Institute
b. American National Specification Institute
36
I
PLUMBING CODE SAMPLE QUEST IONS
I less than _
a. I 02.34
kpa.
b. 102.24
I c. l 02.42
d. J 02.43
I 28. for flush tank supplies, the available pressure may not be less than _ _ kpa.
a. 55.16
b. 45.16
I c.
d.
35.16
65.16
I 29. In getting the result in the loss in static pressure in kpa, multiply the difference in elevation by _ _ .
a. 9.79
I b. 8.72
c. 8.93
d. 9.82
I 30. What is the minimum size of connections for the cold water line for bathtub, bidet, and combination
sink and tray.
I a. 19mm
b. 13 mm
c. 25.4 mm
I d. 332 mm
I 31. What is the minimum size of connection fo r the hot water line for bathtub, bidet, combination sin I and
tray, dental lav kitchen sink, laundry tray.
a . 19mm
I b. 13 mm
c. 25.4 mm
d. 332 mm
I 32. What is the minimum size of connections for the cold water line for bedpan washer, urinal and
flu shometer valve?
r a. 36 mm
b. 28 mm
c. 25 mm
d . 32 mm
37
PLUMBING CODE SAMPLE QUESTIONS
33. What is the minimum size of connection for the hot water line for lavatory?
a. IOmm
b. 12 mm
c. 19mm
r d. 21 mm
34. What is the minimum s ize of connections for the cold water line for dental unit or cuspidor, drinking
fountain, lavatory, flushometer tank and flush tank .
a. IOmm
b. 13 mm
c. 19 mm
d. 21 mm
l 35. What is the minimum size of connect ions for the cold water line for the urinal stall?
a. lOmm
b. 13 mm
1 c. 19mm
d. 21 mm
36. The pressure available for friction loss in kpa divided by the developed lengths of the pipe from the
water main to the highest fixture, times one hundred wi II be the average permissible friction loss per _ _
meters length of pipe.
a. 60.80
b. 23.40
f c. 20. 80
d. 30.40
37. Velocities shall not exceed _ _ m/sec of the maximum values given in the appropriate installation
standard.
a. 3
b. 6
c. 9
d. 12
38. When disposal fields are installed, a minimum of _ _ sq. meter of trench bottom shall be provided
for each system exclusive of any hard pan, rock, clay or other impervious formations.
a. 10
b. 12
c. 14
d. 16
39. Side wall area in excess of the required 304.8 mm and not to be exceed mm below the leach line
may be added to the trench bottom are when computing absorption areas.
38
I
PLUMBING CODE SAMPLE QUESTIONS
I
a. 914.4
I b. 812 .6
c. 618.3
d. 712.4
I 40. Where leaching beds are permitted in lieu of trenches, the area of each such bed shall be at least_
% greater than the tubular requi rements for trenches.
I a. 50
b. 25
c. 60
I d. 75
41. No excavation for a leach line or leach bed shall extend within meter of the water table nor to a
depth where sewage may contaminate the underground water stratum that is usable for domestic
purposes.
I a. 1.2
b. 1.5
c. 2.4
,~
d. 1.8
Septic tank
I 42. The in let compartment of any septic tank shall be not less than 2/3 of the total capacity of the tank,
I
39
I
PLUMBING CODE SAMPLE QUESTIONS
r b. 2 cum
c. 3 cum
i d. 4 cum
I 46. if the capacity has 6 cum, the secondary compartment may be not less than _
a. 1.8 '
m in length.
b. ! .2
I c. 1.5
d. 2.4
I 47. Access to septic tank shall be provided by at least 2 manholes _ _ mm in minimum diameter or by
equivalent removable slab cover.
a. 608
I b. 508
c. 720
d. 550
I 48. Whenever a first compartment exceed - , - m in length an additional manhole shall be provided over
I 49. the vertical leg of a round inlet and outlet fittings shall not be less in size than the connecting sewer
pipe nor less than _ mm.
a. I 01.3
I b. 102.4
c. I 03.4
d. 104.6
I
50. A baffle type titting shall have the equivalent cross-sectional area of the connecting sewer pipe and
I not less than a_ mm horizontal dimension w hen measured at the inlet pipe inverts.
a. 101.3
b. I 02.4
c. 103.4
r d. 104.6
{ 51. The inlet and outlet pipe or baffle shall extend _ mm above and at leasAl4. 8 mm below the water
surface.
a. I 01.3
b. I 02.4
c. 103.4
40
PLUMBING CODE SAMPLE QUESTIONS
I d. 104.6
I 52. The invert of the inlet pipe shall be at a level not less than _ mm above the invert of the outlet pipe.
. a. 60.8
I b.
c.
50.8
70.8
d. 40.8
I 53. the sidewall shall extend at atleast _mm above the liquid depth.
a. 228.6
I b. 338.6
c. 224.2
d. 226.3
I 54. The cover of the septic tank shall be at least_ mm above the back vent openings.
I a. 60.8
b. 50.8
c. 70.8
I d. 40.8
55. partitions or baffles between compartments shall be of solid durable material and shall extend at least.
_mm above the liquid level.
I a. 104.2
b. 103.4
c. I 01.6
I. d. I 02.3
56. An inverted fitting equivalent in sie to the tank inlet, but in no case Jess than_ mm in sie shall be
I installed in the inlet compartment side of the baffle with the bottom of the fitting.
a. I 01.3
I b.
c.
102.4
I 03.4
d. 104.6
I 57. All septic tank covers shall be capable of supporting an earth load of not less than_ kpa. When the
max coverage does not exceed 9 meters.
( a. 14.4
b. 12.6
c. 10.8
r d. 16.2
58. The minimum wall thickness of any steel tank shall be_
a. 8 us ga
b. 10 us ga
41
I
PLUMBING CODE SAMPLE QUESTIONS
I c. 12 us ga
d. 14 us ga
I
DISPOSAL FIELD
I 59. When seepage pits are used in combination with disposal fields, the filter material in the trenches shall
terminate at least_ meter form the pit excavation .
a. 1.5
I n.
c.
1.2
1.35
d. 0.90
I 60. When the quantity of sewage exceeds the amount that can be disposed in _ linear meater of each
line, a dosing tank shall be used.
I a.
b.
103. 4
121.4
152. 4
I c.
d. 148.2
I 61. Disposal field shall have a minimum bottom width of trench of_ mm.
a. 551.3
b. 447.3
I c. 448.2
d. 457.2
I 62. The minimum spacing benveen trenches or leach ing beds shall be_ mm plus 0.60 for each
additional 0.30 min depth in excess of0.30 m below the bottom of the drain line.
a. 1.2
I b. 1.35
c. I .5
I d. 1.6
63. Distribution drain line in leaching beds, shall be more than I .8 m apart on centers and no part of the
perimeter of the leaching bed shall be more than_ meter from a distribution drain line.
f a. 0.90
b. 0.80
c. 0.70
f d. 0.60
64. Each seepage pit shall be circular in shape and shall have an excavated d iameter of not less than m.
a. I.I
b. 3.2
C. 2.2
d. 3.4
42
I
PLUMBING CODE SAMPLE QUESTIONS
I
I 65. Each cesspool shall have a minimum sidewall of._ m below the inlet provided however that when a
strat of gravel or equally pervio us material of 1.2 m in thickness is found the depth of such sidewall need
not be more than 3. 10 m below the inlet.
I a. 203.4
b. I 0 1.4
c. 304.8
I d. 302.8
66. Every abandoned bldg sewer o r part thereof shall be plugged or capped in an approved manner with
I _ meter of the property line.
a. 1.5
b. 1.2
I c.
d.
1.35
0.90
I a. 0.7 5
b. 0.30
c. 0.90
I d. 0.60
7 I. What is the minimum horizontal distance from property line adjoining private property to septic tank.
a. 1.5
43
I
PLUMBING CODE SAMPLE QUESTIONS
I
b. 1.2
( c.
d.
l.35
0.90
I 73. what is the minimum horizontal distance from water supply well to bldg sewer.
a. 15.2
I b. 30.5
c. 45.7
d. 24.70\
I d. 24.70
I
f
44
I
I
I
I
I
I ...
.......
·~i.,. ,,
.
I
I PRACTICAL
I
I PROBLEMS
I (Sample Questions)
I
I
I
- ~14096
~75353343
-- ----
--0917_535334~~...
~ ------~- jptutorials101@gmail.COQ1 · ~~ Q
,
E 'JptJutorials
G.,i: ·.. ..
~~
~ ,i) :!" C: ~
..
(..._
. ,..,. - A~~ . .. . . •• W
lI
I
PRACTICAL PROBLEMS SAM PLE QUESTIONS
I INSTRUCTION: Select the correct answer for each of the following questions. Mark only one answer
I fo r each item by encircling the letter of you r choice. STRICTLY NO ERASURES ALLOWED.
MULTIPLE CHOICES:
PART I
I. As an experienced plumber, what is tlhe recommended size of the drain serving water closet?
I a. 3 inches
b. 4 inches
c. 5 inches
d. 6 inches
I 4. A hotel requires hot and cold water supplies. What kind of pipe is best suited?
a. Cast Iron pipe c. Galvanized Wrought-Iron pipe
b. Copper pipe d. Plastic/Synthetic pipe
5. A registered master plumber is consulted to install piping system for water, gas, steam and oil. What
kind of pipe is recommended?
a. Cast Iron pipe c. Lead pipe
b. Plastic pipe d. Wrought-Iron pipe
6. What kind of pipe to be used where heating pane.ls. are considered in concrete slabs for the purpose of
r melting snow?
a. Plastic pipe c. Lead pipe
b. Wrought-Iron pipe d. Terra-cotta pipe
I'
I
7. When cutting pipe that coated internally with enamel or glass, delicate core should be taken to avoid
cracking or chipping the internal coating. What kind of tool that should never be used for cutting such
pipe?
a. Adjustable Hacksaw c. Wheel pipe cutter
b. Pipe reamer d . Square-edge pipe cutter
1
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I
9. What is- that tool used for expanding the ends of lead pipe?
I I 0. When using an extension ladders, what will be the maximum sliding sections allowed?
a. 2 Yi sliding sections c. 3 Y:z sliding sections
I h. 2 sl iding sections d. 3 sliding sections
I I. An 8 meters aluminum ladder is used in delivering plumbing fixtures to the second the foot of the
I ladder be placed from the wall of the building?
a. 2 meters c. 3 meters
b. 2 Y:z meters d. 3 Y:z meters
I
12. As registered master plumber, you have to use a ladder to carry the pipes to the second floor of the
I building, what will be the horizontal distance from the foot of the ladder to the wall that you considered
proper?
a. 1/4 of the ladder's length c. Y:z of the ladder's length
I b. 113 of the ladder's length d. 3/8 of the ladder's length
13. What is that valve recommended for installations that call for throttling?
I a. Globe valve
b. Gate valve
c. Check valve
d. Angle valve
I 14. What is the approximate height above the floor level of a kitchen sink?
a.30inches c.36 inches
b.34inches d.38 inches
I
15. What is the approximate height above floor level of a built-in bathtub floor level?
I a. 12 inches
b. 16 inches
c. 18 inches
d.24 inches
16. What is that device used to support the water supply riser?
a. Pipe rest c. Iron insects
b. Iron ring d. Eye log bolt
17. What is that fitting necessary in a water supply system which is used to the water supply in some
portion of the installation?
a. Meter stop c. Curb stop
b. Valve d. Corporation stop
18. What kind of valve is suited for the main water supply lines and pump lines?
a. Angle valve c. Globe valve
2
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
i 19. Generally, the registered master plumber must be systematic in connecting the riser branches to the
main of the water supply system. What will be the right angle of all branches connection to the main?
I a.JO
b.45
c. 60
d. 90
I 20. What do you cali the plugging of.an open in!! with oakum. lead or other materials which are pounded
into place or m&tcrials pounded into the opening?
a. Caulking c. Stopping
I b. Plugging d. Closing
I 22. What is the minimum length ohime before a jointed plastic pipe be subjected to pressure test?
a. I .5 hours c. 2.5 hours
I b. 2 hours d. 3 hours
23. In bending plastic pipe, what will be the practical material to be used to prevent fattening of the pipe?
I a. Sand
b. Gravel
c. Water
d. Metal spring
I 24. What is that part of the piping o f a plumbing installation which supplies the plumbing fixtures w ith an
adequate flow of water?
a. Soi l and vent piping system
I b. Domestic hol water piping system
c. Domestic water distribution system
d. Water and waste piping system
I
25. What is the usual horizontal length that the cast iron be supported to prevent damage at joints caused
I by sagging?
a. I .25 meters c. 1.75 meters
b. I .50 meters d. 2.00 meters
r 26. What is the name of the instrument which used in caulking oakum in the joints of cast iron pipe?
a. Iron rod c. Chisel
b. Yarning iron d. Angle bar
27. What will be provided to prevent contamination from the polluted water of the fire truck to the house
water supply system?
a. Gate valve c. Water main stop
3
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I 30. What is that feature which offers a convenient water supply for firemen, making it necessary for the
fire department to transport and user much expensive fire fighting apparatus?
I a. Stand pipe
b. Fire truck ladder
c. Fire truck
d. Overhead water tank
I 33. Why is it that corporation stop required when the main water pipe is tapped with pressure on?
a. It serves as a meter.
b. It serves as a pressure balancer.
c. It serves as a control stop.
r d. ft serves as a shut-off when water is excessive.
34. It is essential that pipe threads be cut accurately to ensure that threads for fittings will be universal so
that the manufacturers of pipe threading equipment follow the American Standard. How many threads per
inch for pipes having a diameter of 3 inches/ 4 inches/ 5 inches?
I. 3-inch diameter?
a.5 c. 14
b. 8 d . 18
a. 5 c. 14
4
I
P RACTICAL PROBLEMS SA MPLE QUEST IONS
I b. 8 d. I 8
I a. 5
b. 8
c. 14
d. 18
I 35 . The allowahle tensile .stress of wrought iron -;reel pipe is 750 psi. It is robe u<>ed for hot water supp l)
with a working pressure of 300psi. What schedule of the pipe should you specify? Use the formula:
I 37. A wrought iron pipe schedule 40 can withstand a steam pressure up to?
a. I 25 psi c. 250 ps i
b. 200 psi d. 300 psi
I 38. Name that tool wh ich is made of boxwood, dogwood or lignum vitae, and it is used for dressing or
working sheet lead, lead pipe bends, and bath traps.
I a. T urn pin c. Shave hook
b. Dresser d. Drift plug
39. What is that handy tool for threading the end of the pipe in a trench or in the corner of a cellar where a
5
I
PRACTICA L PROBLEMS SAMPLE QUEST IONS
I
b. Straightened a tapered -tap in a ho le
c. Expands the ends of the lead pipe
I d. Retain melted lead in ajoint
I 42. In a certain plumbing installation, a lead pipe is being used. How do you usually join the lead pipe?
a. Melting the pipe ends c. Tapping the pipe ends
b. Threading the pipe ends d. Reaming the pipe ends
I 43. What should be the maximum length of the ladder when fully extended of an extension ladders?
a. 40 feet c. 60 feet
I b. 50 feet d. 70 feet
44. What is usually the primary cause of troubles in excavating operations for water pipes?
I a. Inadequate drainage
b. Underground uti Ii ties
c. Lack of shoring
d. Stagnant water
I 45. What w ill be the maximum water service pressure at the point where the building distribution system
begins?
I a. 80 psi
b. 90 psi
c. I 00 psi
d. 120 psi
I 46. What is the suitable gasket materi.al for a flange union in oil lines?
a. Rubber or asbestos sheet
b. Ru bber or asbestos composition
I c. Metallic or rubber composition
d. Metall ic
I 47. What is the suitable gasket material for a flange union in cold water piping?
a. Rubber c. Metallic
I b. Leather d. Asbestos
48. What is the suitable gasket material for flange union in gasoline conduction?
49. What is the sm~llest plumbing fixture used as the basis in determining the fixture unit value?
I a. Lavatory or wash basin
b. Floor drain
c. Water closet
d. Kitchen sink
50. As an experienced registered master plumber, what will be the ideal size of the P-trap that should be
installed underground or embedded on a concrete slab?
6
I
PRA CTI CAL PROBLEMS SAM PLE QUESTIONS
I a. JOO mm c. 200 mm
b. 150 mm d. 250 mm
I
I 51. A I OOmm x 3.0m plastic pipe is used to install in house drainage. The face-to -face distance is 4.40
meters. The engagement length is 45mm and the solvent cement per joint requires is 16 grams.
II I. If the cost of solvent cement is 80.00php per gram . What is the total cost of solvent cement?
I a. 2,560.00php c. 5, 120.00php
b. 3,840.00php d. 6,000.GOphp
I 52. What condition must be satisfied for the water supply in building?
a. Fast removal of the waste with a minimum probability of leakage and stoppage of drain.
53. Each fixture in the Plumbing system represents a certain demand for water, what is the water demand
I of the wall hydrant?
a. 3 gpm c. 8 gpm
0
I b. 5 gpm d. 9 gpm
54. Each fixture in the Plumbing system represents a certain demand for water, what is the water demand
f 56. Each fixture in the Plumbing system represents a certain demand for water, what is the water demand
of the sink faucet?
' .
7
PRACTICAL PRO BLEMS SAMPLE Q UEST IONS
a. I gpm c. 3 gpm
b. 2 gpm d. 4 gpm
57. Each fixture in the Plumbing system represents a certain demand for water, what is the water demand
of the drinking fountain?
a. I/2 gpm c. 3/4 gpm
b. 2/3 gpm d . 4 gpm
58. What is the name of that piece o f pipe less than 12 inches in length threaded on both ends?
a. Short pipe c. Pipe
b. Cut pipe d. Nipple
59. What do you call that short pipe:; whose thread at both ends meet?
a. C lose nipple c. Shoulder nipple
b. Short nipple d. Long n ipple
60. What do you call that pipe whose thread at both ends leaves a small amount of space?
a. Cut pipe c. Short p ipe
6 I. What is the minimum nominal diameter of a water service line pipe which will provide the building
'I a. 25%
b. 20%
a. 5%
C. 10%
d. 5%
I b. 10% d . 20%
66. A 25mm diameter water pipe can carry water equivalent to how many J 2mm diameter water pipe?
a.3 c. 5
8
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I b.4 d.6
I 67. The recommended fall per foot fo'r a 4-inch pipe and larger is____ .
a . 1/2-inch per foot c. 1/4-inch per foot
68. The recommended fall per foot for a 3-inch pipe and smaller is _ _ .
I 69. Ln roughing-in for lavatory that is to have an I Yl-inch drain, the distance between the fixtu~p and
the vent is not more than . /
a. 10' -0" c . 3' - 0"
I b. 6' - O" d.5' - 0"
70. What is the maximum depth of trench for sub-surface drain tile where the soil is of satisfa~
I absorption?
a. 4'-1 '' c. 2'-1 ''
/ ~
71. Each fixture in the plumbing system represents a certain demand for water. What is the water demand
I 73. Generally, what is the diameter of the standpipe for buildings two or three stories in height?
a. 4 inches
b. 6 inches
c. 3 inches
d. 2 inches
I 74. Generally, what is the standard diameter of the standpipe for buildings more than six stories in heigh~
a.4inches c.3 inches
75. Why is a wet standpipe with siamese connection considered most practical?
a. Jt is the specification of the fire department
b. There is no need for the fire department pumper to used
c. It is the cheaper type of connection
d. It is being served by the domestic water supply system under constant pressure
9
I
P RACT IC A L PRO BLE MS SAMPLE QUESTION::>
I 76. What is the disadvantage of the wet standpipe with siamese connection?
a. The danger of contamination of the building water supply from the unknown source
I b. The siamese connection is expensive
c. The exposed siamese connection and pipe can be subjected to vandalism
77. What is the practical method of repairing or correcting leak of a plastic pipe?
I 78. Careful installation of the water supp ly distribution is essential. Which statement differs among the
group?
a. Sufficit:nl grade and proper alignment
I b. Short offsets and unnecessary fittings
c. Carefully installed conriections
d. Adequate size
I 79. Damage to property leaking points, trapped piping and water hammer in a water system are attributed
I to _ __
a. Poor workmanship c. Poor materials
b. Poor design d. Poor planting
I 80. In what ways must the water distribution system be suspended from the basement ceiling in large
concrete buildings?
I a. Using lead pipings
b. Using wooden plugs
c. Using eye log bolts
d. Iron inserted on the tough floor sheating and slushed into the concrete slab
I 81. Why is that it is not good practice to use a gate valve on a lawn sprinkler?
a. It is expensive c. Tt will fai l to close tightly
b. It is bulky d. It is hard to operate
I 82. Why must basement water supply must be properly graded and aligned?
a. To pitch the water lines to one low point
I b. It is conven ient to provide a drum v~e to make it possible to drain the entire water system
c. To eliminate the danger of property damage
d. All of the above
10
PRACTICAL PROBLEMS SAMPLE QUESTIONS
d. At the midpoint between the corporat ion stop and the curb stop
84. What is the recommended distance above the flow level rim of a unit for a vacuum breaker to be
installed?
a.6 inches c. 9 inches
b. 4 inches d. 12 inches
86. What kind of pipe usually used as leaders in tall buildings? )<;1
a. Wrought iron pipe c. Copper pipe
b. Plastic pipe d. Cast iron pipe
87. What will be the best kind of pipe for underground drains within the buildings?
a. Cement pipe ' c. Cooper pipe
b. G. I. pipe d. Cast iron pipe
88. The drainage system in the building should be designed, constructed and maintained as to guard
against fouling, deposits o f so lids and clogging. What feature should be provided to make maintenance
efficient and effective?
89. Why is that rainwater leaders are often not included as part of the sanitary drainage system?
a. Not to overload the sewerage system
b. Rainwater has no cleansing effect
c. Volume of water is unpredictable
d. Excessive rainwater hinders the treatment of the sewage
PART IIf
I. A type of vent applied on installations with multi-branch interval where the vertical vent pipe takes off
in front of the first fixture and connects with the vent stack.
a. relief vent b. loop vent
11
PRACTICAL PROBLEM AMPLE QUEST IONS
3. A threaded fitting used to join two threaded fitt ings as close as possib le but not exceed ing r
a. nipple h. union
c. coupl ing d. none of the abo\'e choices
4. Tbe following are the list of purposes of providing a venting system in the plumbing system
Which in the list is not a purpose?
a. to convey foul smell present in the pipes b. to protect the seal in the trap it serves
c. to enable the drains to drain faster and better d. to carry the combustible sewer gas out of the building
6. The term applies to the interconnection of the same fixtures in one soil o r waste branch with o ne branch
vent.
a. Battery of fixtures b. Series of fixtures
e. multiple fixtures d. a fixture Un it
7. A single vent that ventilates multiple traps in the case of a back to back fixtures.
a. crown vent b. common vent
b. individual vent d. back vent
9. A pipe in the plumbing system, which conveys the discharge of liquid and solid wastes from water
closets, with or without the discharge fi-om other fixtures to the house drain.
a. waste pipe b. soil pipe
c. stack pipe d. special waste pipe
I?· Water distribuiion system, which constantly re ly its pressure from main water pipe, applied only if the
h1ghe~t fixture is supplied continuously with the flow rate and minimum required working pressure.
a. zoning system b. up-feed o r direct method
c. booster system d. down-feed method
12
ii
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I l. A system of a bui !ding which includes the water supply, distribution pipes, fixtures and t;ixture traps,
•
t: the soil, waste, and vent pipes; The house drain and house sewer, the storm water drainage system with
their devices, appurtenances and connections all within or adjacent to the building.
a. Sanitary system b. Plumbing system
12. The lowest portion of the interior part of any pipe or conduit that is not vertical
•
'
r
I
a. Invert
c. crown
b. Invert Elevation
d. crown weir
13. Single lever valves used in kitchen a nd lavatory faucets o r at shower valves, works by the principle or'
a. gate valve b. angle valve
c. ball valve d. globe valve
•
1
c. amount of fall of the pipe c. type of venting system
I 16. A method of water correction done by passing water through it thus making hard water a soft water
a. zeolite process b. chlorination
1 b. aeration
I d. filtrati on
17. A type of vent w here the vertica l vent pipe takes off in front of the last fixtu re and connects it to the
I soil stack which act as a vent.
a. ci rcuit vent b. loop vent
c. yoke vent d. relief vent
I
18. A common term fo r a two-way fire service connection
a. Siamese connection
I b. wet standpipe
c. combination slandpipe
d. dry stand pipe
I
19. the level in a fixture at which water begins to overflo w over the top or rim of a fixture.
a. n ood level .
b. rim
c. fixture edge
d. counter top
13
PRACTICAL PROBLF:M S SAMPLF: QlJESTIONS
I'
20. The abbreviation JPS stand for
._, a. Internal Pipe Size
! b. Iron Pipe Size
c. Ind ividual Pipe Size
2 1. A vertical length of so il or waste stack at eight feet in heig ht within which horizontal branches from
one storev - or floor of the building or structure are connected to the stack.
~
a. stack
b. soil stack
c. branch interval
d. horizontal soil or waste branch
I 22. The top edge of a plumbing fixture or receptacle from which water overflows.
a. wall hung urinal
.I b. stall urinal
c. with pedestal urinal
d . trough urinal
I 23. A kind of plastic pipe which has exce ll ent chemical, crush and fire resistance, high impact and tensile
strength and is non toxic; used for hot and cold water applications.
·1 a. polyvinyl cnloride
b. chlorinated polyvinyl chloride
c . unplasticized polyvinyl chloride
~1 d. polypropylene
24. A piping material made from mild steel that is drawn through a die and welded. It is dipped in bath of
I zinc, which treatment serves to some degree the pipe against the effects of acids.
a. galvanized ~tce l pipe
I 25. A malleable iron fining for threaded p ipe, having a 45 degree or 90 degree bend, with an inside thread
on one end and o utside thread on the other.
r a. street elbow
b. straight elbow
c. return bend
d. Y. bend
26. A property of pipe having the ability to resist being worn away by friction when rubbed with another
object.
a. hardness
14
I
PRACTICAL PROBLEMS SAMPL E QUESTIONS
I b. tear resistance
c. abrasion resistance
d. flow resistance
i' 27. The first section of water supply piping in a building after the water meter.
a. water service pipe
b. water distributing pipe
I 28. The vertical distance between the top dip and the crown weir.
a. trap seal
b. water seal
I c. dry seal
d. invert elevation
I 29. A device located at the bonom of a flush tank for flushing water closets and similar fixtures.
a. flush valve
I b. gate valve
c. float valve
d. flushometer valve
I 30. A water supply pipe connecting the fixtu re with the fixture branch pipe.
a. fixture branch
I b. fixture supply
c. branch pipe
d. fixture tube
I 31. A common measure of the probable discharge into the drainage system by various types of plumbing
I c. discharge unit
d. flow rate
32. A short length of pipe with external threads at each end used to join couplings or fittings.
1 a. union
b. nipple
c. socket
d. bushing
33. Porcelain enamel ware, such as bathtubs, toilet bowls, washbasins, etc.
a. plumbing appurtenance
b. plumbing fixture
15
I
PRACTICAL PROBLEMS SA MPLE QUESTIONS
I c. sanitary ware
d. plumbing fitting
. 34. A fitting with a projecting collar along the edge; used on installation requiring an increased area
35. A type of water closet having a flusli tank attached at the back of closet bowl.
a. comer toilet
b. one piece
I c. low profile
d. close coupled
i 36. A type of valve in which the flow of liquid is controlled by a rotating drilled ball that fits tightly
)
i a. angle valve
b. ball val~e
c. globe valve
I d. flush valve
37. The process of plugging an opening with oakum, lead or other material that are pounded into the
I annular space space in a bell and spigot cast iron pipe.
a. brazing
b. flaring
I c. welding
d. caulking
I 38. A pipe which carries the discharge of bidets or similar fixtures with or without the discharge of other
fixtures to a sewer or approved drain.
I a. soil pipe
b. waste pipe
.. c. waste stack
d. soil and waste pipe
' 39. A water supply pipe that extends vertically one full storey or more to convey water to fixture branches
or group of fixtures.
a. vertical water pipe
b. downfeed pipe
c. water branch pipe
d. riser
16
\
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I
I 40. An outhouse used for the deposition of excrement.
a. privy
b. cesspool
I 42. A valve placed on the water main to which the building water service is connected.
a. curb cock
I b. gate valve
c. corporation stop
d. globe valve
I 43. The extended portion of a pipe that is closed on one end to which no connections are made on the
extended portion thus permitting stagnation o f wastewater or air therein.
I a. house drain
b. building sewer
c. dead-end
I d. pipe run
44. A covered, usually small tank used chiefly for storing rainwater for domestic use other than for
I drinking purposes.
a. catch basin
I b. cistern
c. catchment
d. junction box.
I PART IV
I. A pipe fitting with a removable plug which provide access for
I inspection or cleaning of the pipe run.
2. A soil o r waste system where all piping are threaded pipe, tube or
other such rigid construction using recessed drainage fittings.
I 3. A common measure of the probable discharge into the drainage
system by various types of plumbing fixtures on the basis of one dfu being equal to 7.5 gals per minute.
4. The volume of water used by plumbing fixture in a given amount of
time. Usually expressed in gals per minute (gpm).
17
\ \
I
PRACTICAL PROBLEMS SAMPLE QUEST IONS
5. _ _ _ _ _ _ _ _ _ ____ The lowest portion or the lowest inside surface ofa channel, conduit,
drain, pipe or sewer pipe. ,
6. - -- - - - - -- -- -- Any part of a piping system other than the main , riser or stack.
7. A device which introduces air into an exiting stream of water.
I 8.
than its original source.
The flow of water into a water supply system from any source other
9. - - -- -- - -- - - - - A water suprly pipe connecting the fixture with the fixture branch.
I I0.
building served.
The ripe from the water main or source of water supply to the
I 14.
15.
A vertical soi l pipe conveying fecal matter and waste water.
Any pipe which conveys the discharge of water closet, urinal or
fixtures having similar functions, with or without the discharges from other fixtures to the bldg, drain or
I bldg sewer.
16. Condition or any arrangement whereby reverse flow can occur.
17. A pipe flange that is not drilled for bolt holes.
I 18. A length of soil or waste stack corresponding in general to a story
height, but in no case less than 2.43 meters within which the horizontal branches may be connected to the
stack.
I 19. _ __ _ _ _ __ __ _ _ The length of pipe measured along the center line of the pipe &
fittings
I 20.
21.
A bathroom containing a water closet, a lavatory and a bathtub.
A bathroom containing a water closet a lavatory and a shower bath
22. The installation of all parts of the plumbing system which can be
I completed prior to the installation of fixtures. These include drainage, water supply and wet piping and
necessary fixture supports.
23. A group of fixtu res located adjacent to the stack so that by means of
I proper fittings , vents may be reduced to a min imum.
24. The banging noise in pipe caused by a quick closing valve.
25. A secondary pipe line.
' 26.
atmospheric pressure.
27.
2~. .
.
A suction by the flow of liquids in pipes, a pressure less than
18
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I 32. , The lowest piping of the drainage piping system that receives the
discharge from soil, waste and other drainage pipes inside the wells.
33. The first section of water supply piping in a building after the water
meter.
40. _ _ _ _ _ _ _ __ _ _ _ A shallow, flat bottom, fixture that is used in the kitchen for cleaning
I dishes in connection with preparation of food.
41. A fixture designed foe=r washing of the hands and face which is
I 43.
44.
Slop sink
Applies to fixtures in residences and apartments, and to fixtures to in
non-public toilet rooms of hotels and metals & similar installations.
45. Is a vent, the primary function of which is to provide air circulation
between drainage and vent system.
46. An arrangement of venting so installed that one vent pipe will serve
I two traps common.
47. A vent which carries neither water nor waterborne wastes.
48. A vertical pipe installed to provide circulation of air in a plumbing
I system and for reducing the pressure exerted in trap seals.
49. The principal artery of the venting system to which vent branches
I may be connected.
50. The continuation of a horizontal soil or waste pipe beyond the
connection at which liquid waste fro a fixture enter the waste or soil pipe.
I 51.
52.
A branch vent that performs its function for ffi'..O~ or more traps.
A vent connecting from a branch of the drainage system to a vent
stack.
I 53. _ _ _ _ _ _ _ __ __ _ A vertical vent that is a continuation of the drain to which the vent
connects.
54. pipe or pipes installed to provide a flow of air to o r from the drainage
I system or to provide circulation of air within such pipe to protect trap seal from siphonage and back
pressure.
55. A valve in which the flow of fluids is controlled by rotating drilled
ball that fits tightly against a resilient seat in the valve body.
'
19
I
PRACTICAL PROBLEMS SAMPLE QUEST IONS
I 58. - - - - - - - - - - -- A globe valve in which the inlet and outlet opening one at 90 degree
angles to one another.
59. _ _ _ _ _ _ _ _ __ a safety valve that automatically protects against excessive
I 68. - - - - - - - - - - --
69.
A vise to ho ld pipe or tubing
A tool used to remove square or octagonal shaped threade faucet
scats.
I 70. _ _ _ _ _ _ _ _ _ _ __ A wrench that ~a\ly chain that is slipped around and attached to
the wrench handle.
71. A pipe wrench that resembles a pipe wrench, except for its ~mooth
I la.XYS. It is used to ho ld or tum hardware having flat surfaces.
72. A tool used to remove interior and exterior burrs.
I 73.
74.
A tool used for cutting internal threads, as in a pipe.
A tool used for bending flexible copper tubing.
75. A wrench that has swivelingjaws that is used to hold nuts in a basin
I 76.
77.
A tool used for no hub soil pipe installation
An auger for searching cable which is broken o r lost in line.
78. Used for lines which where have become badly greased with
I detergents and have to be opened.
PARTY
I I. What is the minimum diameter of water supply pipe for water c loset with tank?
~'dia
b.W'dia
I
20
I
I
PRACTICAL PRO BLEMS SAMP LE QUESTIONS
I
2. What is the joining method of installation for PPR pipes?
I a. by threading
b. by solvent cement
• c.
d.
by heating
none of the above
3. What is the standard length of 1he PVC pipes S-1000 for soil waste and vents?
I a. 3 m '
b. 4m
I c. 5 m
·-ct-6 m
I 4. What is Jhe usual pipe size to receive waste from bar sink and bath tub?
a. 32 mm
b. 40 mm
I c. 38 mm
d. 50 mm
I 5. If there is a water c loset, what is the minimum duiarneter of soil branch PVC?
a. 3" dia
D b. 2" dia
c. 6" dia
d. 4" dia
I
6. In the digestion chamber, what is the minimum height of the water level?
a. 1.2 m
I b. 1 m
c. 1.5 m
d. 1.8 m
I 7. What is the minimum water inlet for a flush type water closet?
a.~" dia
b. Yi" dia
I
,
c. I" dia
d. 3/8 " dia
8. For a residential with one shower only, what is the best water heating system?
a. multipoint syste!11
I b. centralized system
@single point system
d. none of the above
I
21
I
P RACTICAL PROBLEMS SAMPLE Q UESTIONS
I 9. What is the height required for vent stack thru roo f above the roof if the roof I use for some purpose
like roof deck?
a. 8 ft
b. 7 ft
I c. 2 ft
d. I ft
I I0. It is operated by rai sing and lowering a double-faced wedge shaped gate?
a. globe valve
b. gate valve
I c. check valve
d. none of the above
I 11. What is the required height of waste stub-out for wall mount lavatory?
a. 600 mm
I b. 50 l mm
c. 400 mm
ri,.£>"
d. 460 mm
I 12. What is the minimum distance of water closet floor stub-out from finish wall?
a. 305 mm
I b. 350 mm
c. 285 mm .•
d. 250 mm
I 13. What is the minimum height of flush type water closet water supply stub out fro m finish floor?
a. 650 mm
I b. 550 mm
c. 591 mm
I d. 625 mm
14. A water closet that is easily recognized by the bulge on front and the most noisiest of all types.
,
I a. wash down
b. reverse trap
c. siphon action
d. siphon vortex
15. What kind of p!pe with hub from one end and spigot on the other end.
r a. PVC
b. Cast iron
c. concrete
I d. asbestos
f-
22
I
PR4CTICAL PROBLEMS SAMPLE QUESTIONS
I 16. What plumbing tools to be used in tightening t.he connections between GI pipes and fittings?
a. strap wrench
b. chain wrench
c. pipe wrench
d. pipe threaders
I a. PPR pipes
b. Gl pipes
c. PVC pipes
I d. Copper pipes
I 19. What particular PVC soil and waste fitting receives stack pipe and two branches of soil and waste
pipe.
a. sanitary tee
I b. double bend
c. double tee wye
0
d. tee
I 20. A small level used by plumbers
a. miniature level
I b. torpedo level
c. compact level\
21. The two most common s izes of pipe wrenches used by plumbers are
'I
d. 18" and 24"
' -
23
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I
23. The best tool for cutting cast iron pipe.
i a. hand saw
b. circular saw
- c.jig saw
24. Copper piping used for medical gas system should on ly be cut with a
I a. hacksaw
b. band saw
c. reciprocating saw
I d. copper tubing cutter
25. The only safe method to ignite a torch used for soldering
I a. striker
b. cigarette lighter
I c. match
d. none of the above
' 28. Reciprocating saw blades are selected based on the type of material being cut, length and
a. teeth per inch
b. teeth per foot
c. manufacturer of saw
d. compatibility with band saw
24
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
I a. has an adjustable jaw with teeth
b. has an adjustable smooth jaw
c. also called spud wrench
d. none of the above
33. The most productive method of creating a hole in a metal wall stud
25
\
I
P RACTICAL PRO BLEM S SAM PLE QUEST IONS
I c. that is used to minimize injury fro m a poss ible violent reactin g of the tuol
d. to use if OSHA is on the job site
I 39. Many copper tubing have _ _ to remove the internal ridge caused by cutting the copper tubing
a. a folding triangular reamer
b. Two cutting wheels
I c. a folding file featu re\
d. both a and c
I 40. MSDS
a. material safety delivery schedule
I 41. Excavated soil should not be placed any closer than _ _ from the edge of a trench.
a. l'
I b.2 '
c.3'
d.4 '
I 42 . The person responsible in monitoring a pennit required confined sp,,ace is called
a. an entrant\
I b. a first responder
c. an anendant
d. a monitor
44.0SHA
a. Occupational Safety and Health Association
b. Organization Safety and Health Administration
26
I
PRACTICAL PROBLEMS SAMPLE QUESTIONS
45. The maximum concentration (amount) of a chemical a worker can be exposed to is known as:
I d . concentration allowance
I 47. A tee with the three connections each measuring 2" is correctly ordered as:
a. 2" x 2" tee
b. 2"x2"x2"tee
I c. 2" tee
d. none of the above
I 49. Schedule 40 is
a. thicker than schedule 80 pipe
I 50. The four different types of copper pipe commonly used today are identHied as
a. 1,2,3,& 4
b. A,B,C,& D
f c. M,L,K, and DWV
d. Red, Blue, and Wheel handle
(
51. Two common type of gate valve
27
PRACTICAL PROBLEMS SAMPLE QUESTIONS
28
J
PLUMBING CODE ANSWER KEY
[
PART 1
[ 26. D (PER DAY) 52. A 78. B
r 2.
3.
A
c
28. B
29. D
54. B/C
55. B
80. B
81. c
r 4. A 30. A 56. B 8:!. A
1
I
PLUMBING CODE ANSWER KEY
PART II -ABBR.
r I. UNPLASTICIZED POLYVI YL CHLORIDE
2. UNDERWRl:Y-ES LABORATORY
1
3. INTERNATIONAL ASSOCIATION OP PLUMBING AND MECHANICAL OFFICIALS
2
I
PLUMBING CODE ANSWER KEY
I
26. EXTRA HEAVY
i 27. REINFORCED CONCRETE PIPE
'
r
..
3
PLUMBING CODE ANSWER KEY
7. D 34 . .. o 59. B 86. B
4
PLUMBING CODE ANSWER KEY
I. c 28. A 55. c
2. c 29. A 56. D
3. _A 30. B 57. A
-1. A 31. B 58 c
5. D 32. c 59. A
6. A 33. A 60. c
7. B 34. A 61. D
8. A 35. c 62. A
9. B 36. D 63. A
10. A 37. A 64. c
11. C 38. c 65. 6.10
12. D 39. A 66. A
13. B 40. A 67. D
14. c 41. B 68. A
15. A 42. D 69. c
16. c 43. c 70. c
17. B 44. B 71. A
18. A 45. A 72. A
19. B 46. c 73. A
20. A 47. B 74. A
21. c 48. A 75. A
22. A 49. 0
23. B 50. c
24. A 51. A
25. c 52. 8
26. A 53. A
5
PRA CTICAL PROBLEMS answer key
PART 1
5. A 29. A 53 . c 77. A
6. B 30. A 54. c 78. B
1. A 26. c
2. B 27. c
3. A 28. A
4. c 29. A
s. A 30. B
6. A 31. A
7. B 32. B
8. A 33. c
9. B 34. A
10. B 35. D
11. B 36. B
12. A 37. D
13. c 38. A
14. D 39. D
15. A 40. A
16. A 41. c
17. B 42. c
18. A
43. c
19. A
44. B
20. A
21. c
22 . FLOOD LEVEL RIM
23. B
24. A
1
PRACTICAL PROBLEMS answer key
PART IV
61. FERRULE
62. FITIING
63. COUPLING
64. ELBOW
PARTV
' 1.
2. B
A 20. B
21. D
39. A
40. B
3. A 22. A 41. B
4. c 23. D 42. c
s. 0 24. D 43. B
6. A 25. A 44. B
7. c 26. D 45. A
8. c 27. A 46. A
9. b~ ?, 28. A 47. c
10. B 29. B 48. B
..
11. B 30. B 49. D
14. A 33. A 52 . c
15. B 34. D S3. A
16. c 35. c 54. 8
17. A 36. B SS. D
.. 18. B 37. A
19. A 38. c
/D