Domestic Pump

Condensate Transfer Equipment

S-944M
Condensate Return Units

Series CC™ Series CED™


Condensate return units for systems up to Condensate return units for systems up to
150,000 sq. Ft. EDR. Receivers sized from 6 - 550,000 sq. Ft. EDR The CED offers a flexible
250 gallon (23 - 946 liters). The cast iron solution for handling condensate in commercial
receiver includes a 20 year warranty against cor- applications. The CED has an elevated receiver
rosion. CC units are available in either simplex or that is available in Steel, Galvanized Steel,
duplex design. Receivers have a low height NPT Epoxy Lined Steel, ASME construction or
inlet for easy return line piping and a sepa- rate Stainless Steel. The receiver is sized for 5
NPT overflow that can be used as a sec- ondary minute net storage, with a fabricated steel base
vent. All simplex units include a two pole float with suction piping and isolation valves. The
switch. Duplex units include float switches (a CED is offered with either the Centriflo® or
mechanical alternator is available). All pumps are Series B pumps, including the B35, HB35 and
bronze fitted with bronze case wear rings and HB17 styles. The B pumps have a suction
stainless steel shafts. Pumps are available in inducer to create a positive pressure at the cen-
Series CC 3500 or 1750 RPM. trifugal impeller. The feature lowers the NPSH
(See bulletin S215) requirement of the pump. The CED is available
• Maximum discharge pressure is 90 psi (621 in simplex and duplex configurations. Additional
kPa). pumps are available on request. All simplex
• Maximum seal temperature is 250°F (121°C) units include a two-pole float switch. Duplex
• Maximum pump temperature is *200°F (93°C) units include float switches (a mechanical alter-
*Specific duty points can be rated up to 209°F nator is available). All pumps are bronze fitted
(98°C) requiring only 2’ NPSH. Contact your with bronze case wear rings and stainless steel
local Xylem HVAC Representative for more details. shafts (See Bulletin S240). Stainless Steel
pumps are available.
• Maximum discharge pressure (using
Series CS™ Centriflo® or Series B pumps) 175 psi
Condensate return units for systems up to (1207 kPa)
150,000 sq. Ft EDR. Steel receivers sized from • Maximum seal temperature is 250°F (121°C)
6-250 gallon (23-946 liters). Galvanized or • Maximum pump temperature is 212°F (100°C)
Series CS stainless steel receivers are available. CS units with Series B pumps.
are available in either simplex or duplex design.
Receivers have a low height NPT inlet for easy Series CB™
return line piping and a separate NPT overflow Condensate return units for systems up to
that can be used as a secondary vent. All sim- 90,000 sq. Ft. EDR. The CB is designed for sys-
plex units include a two-pole float switch. tems with low return lines. This condensate unit
Duplex units include float switches (a mechani- features the B-35 pumps which has a suction
cal alternator is available). All pumps are bronze inducer to create a positive pressure at the cen-
fitted with bronze case wear rings and stainless trifugal impeller thus guaranteeing low NPSH
steel shafts. Series B35 pumps can be provided pump requirements. The CB units require only
for 210°F (99°C) applications. Stainless Steel 2’ NPSH and can pump condensate up to
pumps are available. Pumps are available in 210°F (99°C) at sea level. Series CB units
3500 or 1750 RPM. include cast iron receivers, sized from 6 - 250
• Maximum discharge pressure (using gallon (23 - 946 liters). The cast iron receiver
Centriflo® or Series B pumps) 90 psi (621 kPa) includes a 20 year warranty against corrosion.
• Maximum seal temperature is 250° F (121° C) CB units are available in either simplex or
Series CED
• Maximum pump temperature is 200°F (93°C) duplex design. Receivers have a low height
with Centriflo® Pumps (210°F (99°C) NPT inlet for easy return line piping and a
with Series B pumps). separate NPT overflow that can be used as a
Series CB secondary vent. All simplex units include a
two-pole float switch. Duplex units include float
switches (a mechanical alternator is available).
All pumps are bronze fitted with bronze case
wear rings and stainless steel shafts.
(See bulletin S225)
• Maximum discharge pressure 100 psi
(690 kPa)
• Maximum seal temperature is 250°F (121°C)
• Maximum pump temperature is 210°F (99°C)
Condensate Return Units

Series CBE™ The pump bearings are carbon graphite for


Condensate return units for systems up to improved abrasion and wear resistance.
Series CBE 135,000 sq. Ft. EDR. Series CBE receivers are The mechanical seal can be replaced without
elevated 24” (0.6M) above the floor on a weld- removing the pump from the receiver. The con-
ed steel stand. These units are recommended densate level in the receiver is monitored by a
for high temperature condensate applications heavy duty two-pole float switch. These units
where the height of the return lines permit their can be designed for vacuum service with vacu-
use. This condensate unit features the B-35 um tight construction. (See bulletin S230)
pumps which have a suction inducer to create a • Maximum discharge pressure 50 psi
positive pressure at the centrifugal impeller. (621 kPa)
This feature lowers the NPSH requirement of the • Maximum seal temperature is 250°F (121°C)
pump. The CBE units require only 2’NPSH and • Standard temperature rating is 200°F (93°C)
can pump condensate up to 212°F (100°C) at Maximum of 209°F (98°C) on specific
sea level. Series CBE units include cast iron duty points.
receivers, sized from 6 - 250 gallon (23 - 946
liters). The cast iron receiver includes a 20 year Series CHD™
warranty against corrosion. CBE units are avail- Condensate return units for systems up to
able in either simplex or duplex design. 550,000 sq. Ft. EDR The CHD offers a flexible
Receivers have a low height NPT inlet for easy solution for handling condensate in commercial
return line piping and a separate NPT overflow applications. The CHD has a floor mounted
that can be used as a secondary vent. All sim- receiver that is available in Steel, Galvanized
plex units include a two-pole float switch. Steel, Epoxy Lined Steel, ASME construction or
Duplex units include float switches (a mechani- Stainless Steel. The receiver is sized for 5-minute
cal alternator is available). All pumps are bronze net storage. The CHD is offered with either the
fitted with bronze case wear rings and stainless Centriflo® or B35 pump styles. The B pumps
Series CU steel shafts. (See bulletin S225) have a suction inducer to create a positive pres-
• Maximum discharge pressure 100 psi sure at the centrifugal impeller. The feature low-
(690 kPa) ers the NPSH requirement of the pump. The
• Maximum seal temperature is 250°F (121°C) CHD is available in simplex and duplex configu-
• Maximum pump temperature is 212°F rations. Additional pumps are available on
(100°C) request. All simplex units include a two-pole
float switch. Duplex units include float switches
Series CU™ (a mechanical alternator is available). All pumps
Below grade condensate return units for systems are bronze fitted with bronze case wear rings
up to 90,000 sq. Ft. EDR. This unit includes and stainless steel shafts (See Bulletin S240).
24” diameter cast iron receiver or 18”, 30” 36,” Stainless Steel pumps are available.
42” and 48” diameter epoxy coated steel • Maximum discharge pressure (using
receivers designed for installations with low or Centriflo® or Series B pumps)
below grade return lines. The receiver is sized 90 psi (621 kPa)
for 1 minute net storage with a depth of 36” or • Maximum seal temperature is 250°F (121°C)
48”. Pumps are pre-selected to deliver 1 GPM • Maximum pump temperature is 210°F (99°C)
per every 1000 EDR or 2 times the system with Series B pumps.
return rate. The pump(s) are mounted to a steel
cover plate that is bolted to the receiver.

HIGH TEMPERATURE CONDENSATE


Series SP™ (not shown)
Series CHD
Pumpless condensate return units for high tem-
perature returns. SP units use high pressure
steam or air as the motive force to return high
temperature condensate. Single phase electric or
pneumatic controls are required. The receivers
are ASME code stamped. SP packages are avail-
able in 10 different sizes for capacities up to
60,000 lbs/hr. (See bulletin S270)
• Maximum discharge pressure 100 psi
(1207 kPa)
• Maximum temperature is 338˚F (121˚C)
Vacuum Heating and Industrial/Clinical Vacuum Units

VACUUM HEATING UNITS Series VCD (or VCDS not shown)


Series VLR The series VCD vacuum heating unit is designed
Series VLR for large systems through 150,000 sq. Ft. EDR.
Series VLR vacuum heating units provide fast, The VCD include durable cast iron receivers,
even distribution of steam through out the warranted for 20 years against failure due to
steam heating system. Units sized for systems corrosion. The VCDS includes an economical
up to 20,000 EDR. The VLR receiver is separated steel receiver alternative. These units feature
into two chambers, the upper chamber holds individually sized and separately controlled vac-
the recirculated water that is pumped through uum producing pumps and condensate handling
the multi-jet nozzle and venturi creating the vac- pump. These units are available with one vacu-
uum. The lower chamber acts as condensate um and one condensate pump (simplex), one
accumulator and is under the same vacuum as vacuum and two condensate pumps (semi-
that maintained in the return piping. The result duplex) or two vacuum pumps and two conden-
is a compact, economical design. The VLR is sate pumps (duplex). Optional temperature con-
available in simplex or duplex configuration. trols may be added to stop the vacuum pumps
Series VL For older systems with higher air leakage rates, or add cold water when high water tempera-
special capacity units are available to provide tures are sensed. (See Bulletin S330)
additional air removal capacity. • Maximum temperature is 180°F (82°C)
(See bulletin S310) • Pressures to 75 psi (517 kPa)
• Maximum temperature is 180°F (82°C)
• Pressures to 40 psi (276 kPa)
Series VCMD
Series VCMD is a combination vacuum and boil-
Series VL er feed unit that offers a wide selection of cast
Series VL vacuum heating units provide fast, iron, steel, and underground boiler feed
even distribution of steam throughout the steam receivers in conjunction with the dependable
heating system. The VL is designed for systems water jet vacuum units. The vacuum unit can be
Series VCD
from 25,000 to 65,000 EDR. The compact mounted on the boiler feed unit to conserve
design has a cast iron receiver designed for low floor space or be furnished separately.
returns. The unit recirculates water that is Individually sized and separately controlled vac-
pumped through the multi-jet nozzle and ven- uum and water pumps permit maximum flexibil-
turi creating the vacuum. When the condensate ity to met the required design conditions.
level in the receiver raises, a discharge valve (See bulletin S160)
opens allowing the recirculated water to dis-
charge from the VL unit back to the condensate
return system. The VL unit is available in stan- Series VCMD
dard capacity and special capacity for increased
air capacities and higher vacuums for older
systems. (See bulletin S320)
• Maximum temperature is 180°F (82°C)
Series MJ • Pressures to 40 psi (276 kPa)

INDUSTRIAL/CLINICAL MAKE-UP SUPPLY UNITS


VACUUM UNITS Series WSC or WSS
Series MJ Series WSC and WSS are water make-up supply
The Series MJ vacuum pump is ideal for hospi- units. Both units include a positive air-gap to
tal, laboratory, and industrial applications. The eliminate the likelihood of backflow and possi-
MJ uses the multi-jet vacuum producers to pro- ble contamination of city water supply. These
Series WSC & WSS
vide smooth reliable operation for years. A cen- units supply a detached, central, make-up sup-
trifugal pump circulates water through the multi- ply reservoir for deaerators, boiler feed units,
jet nozzle and venturi to create the vacuum. process loads, cooling systems and towers. The
The water is discharged into a separation cham- WSC unit has a cast iron receiver. The WSS has
ber and reused by the pump. Units available in a fabricated steel receiver. A float switch oper-
simplex and duplex configuration. ated solenoid make-up valve supplies water to
(See bulletin S500) the receiver through the air gap fitting.
• Capacities to 344 CFM Available in either simplex or duplex configura-
• Vacuum level to 28” Hg. tion with Centriflo® pumps.
• Available in 3500 RPM (Series C35)
and 1750 RPM (Series C17)
• Capacities to 600 GPM (37.8 l/s)
• Pressures to 100 psi (690 kPa)
Centrifugal Pumps

Series C35 & C17 Centriflo® Series C35™ or C17™ Series B35™ 2' NPSH
These pumps are the heart of Domestic Pump The original low NPSH pump, specifically
condensate-handling equipment. Designed for designed for high temperature pumping. The
the rigorous demands of this service, Centriflo® axial flow propeller provides the necessary
pumps require a lower NPSH than conventional NPSH to the impeller, assuring cavitation fee
pumps. Vertical mounting of the pump saves operation. For more information see bulletin
floor space and gets the motor up above dirt S430. Standard features include:
and water. For more information see bulletin • Rated for 210°F (99°C) condensate in vented
S410C. Standard features include: heightless applications
• Cast iron, bronze fitted with stainless • Cast iron, bronze fitted with stainless
steel shaft steel shaft
• Carbon/ceramic mechanical seals designed • Carbon/ceramic mechanical seals designed
for 250°F (121°C) for 250°F (121°C)
• Available in 3500 RPM (Series C35) • Capacities to 150 GPM (9.5 l/s)
and 1750 RPM (Series C17) • Pressures to 100 psi (690 kPa)
• Capacities to 600 GPM (37.8 l/s)
• Pressures to 100 psi (690 kPa) Series HB35™ & HB17™ 2’ NPSH
End-suction pump with axial flow propeller for
low NPSH applications. These are moderate
pressure at high volume pumps.
(See bulletin S430)
• Rated for 210°F (99°C) condensate in vented
Series B35 Series HB35 & HB17 heightless applications
• Cast iron, bronze fitted with stainless
steel shaft
• Carbon/ceramic mechanical seals designed
for 250°F (121°C)
• Capacities to 350 GPM (9.5 l/s) 1750 RPM
• Pressures to 100 psi (690 kPa) 3500 RPM

Series DB Series DB™ 2’ NPSH Series DB-F™ 2’NPSH


The DB is a close coupled pump with two cen- Base mounted, back pull out design with flexi-
trifugal impellers back-to-back. Placement of ble couple permits ease of service. Coupling
the impellers balances the axial thrust and shielded by a dual rated, ANSI B15.1, Section 8
opposed discharges balance the radial thrust. and OSHA 191.219 compliant coupling guard
The mechanical seal operates between the and containing viewing windows for inspection
stages to prevent excessive wear. of the coupling. This pump has two centrifugal
(See bulletin S431) impellers, back to back. Placement of the
• Rated for 210°F (99°C) condensate in vented impellers balances the axial thrust and opposed
heightless applications discharges balances the radial thrust. The
• Cast iron, bronze fitted with stainless mechanical seal operates between the stages to
steel shaft prevent excessive wear. (See Bulletin S431)
• Carbon Tungsten Carbide mechanical seals • Rated for 210°F (99°C) condensate in vented
designed for 250°F (121°C) heightless applications.
• Capacities to 350 GPM (9.5 l/s) • Cast iron, bronze fitted pump with stainless
Series DB-F • Pressures to 250 psi (690 kPa) steel pump shaft.
• Carbon Tungsten Carbide mechanical seals
designed for 250°F (121°C)
• Capacities to 350 GPM (9.5 l/s)
• Pressures to 250 psi (690 kPa)
State of the Art Facilities

Factory Testing • Electrical and mechanical


components are adjusted
• All built-to-order products and tested for trouble-free
are tested as a complete installation.
unit to meet customer's
duty-point. • Manufactured in an
ISO 9001 certified, state
of the art facility.

®
Little Red Schoolhouse
A Leader Educating the Industry
Bell & Gossett is known throughout the HVAC business as the
industry’s edu- cator. Our Little Red Schoolhouse®, a completely
equipped learn- ing center, has trained more than 60,000
engineers, contractors and installers in the proper design,
installation and maintenance of HVAC systems.
Xylem Inc.
8200 N. Austin Avenue
Morton Grove, Illinois 60053
Phone: (847) 966-3700
Fax: (847) 965-8379
www.bellgossett.com
Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries.
© 2013 Xylem Inc. S-944M November 2011