Download as ods, pdf, or txt
Download as ods, pdf, or txt
You are on page 1of 11

Given Data intensities unit

thikness of slab 200 mm


live load 5 KN/M
dead load due to finishes 1.25 KN/M
cover 25 mm
fcu 40 N/mm^2
fy 460 N/mm^2
unit weight of concrete 24 N/mm^2
Main bar diameter 12 mm
transvere bar diameter 10 mm
Lx 5
Ly 5
unit width of slab 1000 mm

Chart Title
ANALYSIS STEPS OF SLAB

STEP 1 dx
169
STEP 2 dy
158
STEP 3 SELFWEIGHT
4.8
STEP 4 DEAD LOAD
6.05
STEP 5 ULTIMATE LOAD
16.47

MAXIMUN MOMENT

TABLE 3.14 CODE : BS 8110


negative moment at continuous edge βsx = 0.047
RATIO OF posotive moment at continuous edge βsy= 0.045
Ly/Lx posotive moment at mid - span βsx = 0.036
posotive moment atmid - span βsy = 0.034
STEP 6 MAXIMUM MOMENT
Msx(-) 19.35 2
Msx(+) 14.82 3
Msy(-) 18.53
Msy(+) 14

THERE FORE WE will take the greatest moment = 19.35


DEFLECTION CHECK
DEFLECTION CHECK L/D (actual) ≤ L/D(allowable)

L/d(actual) = 29.59 FROM TABLE 3.9 L/d(basic)

modification factor= 1.452 FROM TABLE 3.10

L/d(allowable)= 37.752 OK

SHEAR CHECK
SHEAR FORCE 41.175 As

275.8
SHEAR STRESS 0.24
THEORY
100As/bd 0.16
IF SHEAR STRESS GREATER
THAN HALF OF SHEAR CAPACITY
SHEAR CAPACITY (vc) TABLE 3.8 OF THE SLAB, SHEAR LINKS IS
REQUIRED ELSE NOT REQUIRED
vc 0.48
0.5vc 0.24
Hence
ON CHECK
D(allowable)

26 FOR CONTINUOUS

M/bd^2= 0.68

CHECK
assume Ǿ = 12mm
Area = 113mm^2
Z= 0.95d
ANALYSIS OF COLUMN
Given Data intensities unit
Height (L₀) 3.5 m STEP 1
live load 957 KN/M end conditions
cover 30 mm L₀x
fcu 40 N/mm^2 Lex
fy 460 N/mm^2 Ley
unit weight of concrete 24 N/mm^2 Lex/h & Ley/b
Main bar diameter 16 mm STEP 2
BEAM DIMENSIONS S.L=
WIDHT 250 mm STEP 3
depth 500 mm D.L=
STEP 4
COLUMN DIMENSIONS N=
WIDHT 250 mm STEP 5
DEPHT 300 mm M
COLUMN VOLUME 262500000 mm^3
OF COLUMN

CHECK FOR SHORT AND SLENDER THEORY


condition1 top and bottom β= 0.75
3000
2250
2250
short column
SELF WEIGHT
6300 KN KN
DEAD LOAD
6300 KN KN
ULTIMATE LOAD
13557 KN KN
MOMENT check moment if
177596.7 KN.M d Emin<0.0
262
5*20
Emin 13.1 there is moment
there is a
eccentrici
ty else
there is
no
eccentrici
ty
THEORY
Description of Applied Loads
Load Load
Data Required
Type No
Pa 1 Point Load P at distance a
Uniformly distributed Load w
w 2 per unit length on full Member
Span
Uniformly distributed Total Load
W 3
W on full member span
Uniformly distributed Patch
wab 4 Load w per unit length from
distance a to distance b
Uniformly distributed Patch
Wab 5 Total Load W from point a to
point b
Linearly varying Total Load V
with maximum intensity at
Vambo 6
distance a to zero intensity at
distance b
Linearly varying Total Load V
with zero intensity at distance a
Vaobm 7
to maximum intensity at
distance b
Moment M at distance a,
Ma 8
Clockwise Positive
Two Point Loads P acting at
Pab 9
distance a and b
Note: All vertical loads are Downwards Positive
To apply a Load, first type the load No and then its required values
Shape

P
a w

w
a
Wb

a
b V

a
b
V

a
b
M

a
P P

a b
hen its required values
Ó 2000 Dr Shaiq Khan, Techno Consultants Ltd

You might also like