OPERATING MODE
Immergas reserves the right to make improvements and Press button several times to switch from one
changes to details and accessories, excepting the essential operating mode to the other:
features of the model described and illustrated herein. NO OFF Summer ( ) Winter + MAN ( )
Winter + AUTO ( ) OFF.
In OFF mode, Central heating and DHW are disabled,
Mini CRD INSTALLATION
Installation recommendations.
whereas the Antifreeze function is active.
(Mini Digital The mini CRD, including the relative cables and connec-
tions to the boiler, must be installed by specialised staff.
- Summer ( ) DHW functions are guaranteed, where-
as the Central heating functions are disabled (the
Remote Control) Upon the free initial check of the boiler, when the mini
Fig. 3
antifreeze remains active). Buttons allow
you to view and modify the DHW temperature. In this
CRD is inserted into the system, the Immergas authorised 3) Make the electric connections to the boiler, paying
after-sales centre checks the connection to the generator attention not to operate with a live boiler. Refer to the case, icon switches on and Sn:XX °C is displayed,
terminal board and adjusts operation. The free check of electrical connections indicated in the boiler instruc- where XX indicates the configured set point, which
immergas.com the mini CRD alone is not provided by the Immergas tion manual. The mini CRD does not require com- flashes).
Immergas S.p.A. 42041 Brescello (RE) - Italy authorised after-sales centre, if requested after the start pliance with the connection polarity. The connection - Winter+MAN (manual) icons and switch on.
Tel. 0522.689011 Fax 0522.680617 phase of the boiler warranty. to the boiler is made using two wires with minimum In this case, the DHW and Central Heating function
Attention: laying the mini CRD cables is excluded from section of 0.50 mm2 and maximum of 1.5 mm2 and with are both enabled. Buttons allow you to
Cod. 1.037515 - Rev. ST.001058/000 - 10/15
the free boiler checks; it is the responsibility of the in- maximum length of 50 metres. view and modify the room temperature directly and
staller company. NOTE: for correct installation prepare a dedicated line permanently. To return to normal operating mode,
GENERAL WARNINGS for the connection of the mini CRD according to the press or wait 5" .
Installation operations.
This manual has been drawn-up for: the Installer and Standards in force regarding electrical systems. - Winter+AUTO (automatic) icons , and are
1) Separate the fixing template from the mini CRD body
the User. switched on. In this case, the DHW functions are ena-
(Fig. 1). If this is not possible, interference due to other electric
• Carefully read the warnings contained in this document bled and the room temperature is adjusted according
Install the Digital Remote Control away from heat cables could cause the mini CRD to malfunction.
as they are required to indicate the use of the mini CRD to the Central Heating time program. Buttons
envisioned by the design hypothesis, the technical sources and in a suitable position to detect the room 4) Fix the body of the mini CRD to the mount template, allow you to view and modify the room temper-
features, the installation, assembly, programming, temperature correctly (Fig. 2 and 3). engaging it with pressure (Fig. 1). ature set directly and temporarily (the modification
adjustment and use instructions. 2) Install the mini CRD directly on the wall by using the will be valid until the Comfort temperature switches
• The system must be compliant with applicable IEC specific holes, made on its rear (Fig. 1), and the specific to reduced temperature or vice-versa in the time
Standards. screws supplied. DESCRIPTION OF CONTROLS program set). During this period, icon flashes. To
• The instruction manual must be considered a part of the program two new temperature levels permanently,
mini CRD and must be “kept for future reference”. which will be used by the time program to adjust the
room temperature, proceed as indicated in paragraph
• The mini CRD is intended only for the use for which Programming Comfort and reduced temperature for
it has been expressly designed. Any other use must be Central Heating.
considered improper and therefore dangerous.
• Our products are manufactured in compliance with the
Safety Standards in force. It is, therefore, recommend- Fig. 4 SETTINGS AND PROGRAMS
ed to use all devices and attention in such a way that Setting the required DHW temperature
injury/damage is not caused to persons or objects. Access to Programming/Display and operating Press to display the DHW set point temperature to
parameter setting. display icon , Sn:XX °C and icon . To change the
• Do not remove parts of the mini CRD when it is oper-
set value (flashing), press . To confirm the
ating. Operating mode change / Programming win-
setting, press button or wait 5”.
• Do not use the mini CRD exposed to heat sources or Fig. 1 dow change / Boiler reset.
under the scorching sun. Increase of the value selected. Setting the Maximum Central Heating Set point
temperature allowed.
• The manufacturer will not be held responsible in the
Decrease of the value selected. Press button twice to display the Maximum Cen-
following cases:
tral Heating set point temperature allowed, Mr:XX
a) Incorrect installation. °C and icon . To modify the value set (flashing), use
b) Operating defects of the boiler to which the mini buttons . To confirm the setting press button
CRD is applied. or wait 5”.
1.5 m