Fusion Splicer Calibration Form

Ti m e 16-Jan-2018 Model SAT-17S Operator


S/N 000SATB15071010 Type St andard

Splicing Test
Fiber Type Spling method Test Equipments Model Ref
G.652 SM Aut o
No. Result Conclution Operator
U nder AC pow er suppl y
1 0,027 Pass
2 0,036 Pass
3 0,028 Pass
4 0,017 Pass
5 0,025 Pass
U nder DC pow er supply (battery)
6 0,021 Pass
7 0,028 Pass
8 0,017 Pass
9 0,031 Pass
10 0,029 Pass
Concl uti on:PASS

Ave Loss 0,026 Maxmium Loss 0,036


Remark:

Function Test
No. Description Inspec tion Result O perator

zoom in: X、 Y independent display vi sual


1 Pass
i nspecti on

2 Sensor testing: air pr essur e,r elativ e err or ≤5% i ndicati on Pass

3 Sensor testing: inside temper atur e,r elativ e error ≤5% i ndicati on Pass

4 Sensor testing: ouside temper atur e,r elativ e err or ≤5% i ndicati on Pass
st opw atc
5 Quick star ting function,star t time not beyond 15s Pass
h
Standar d connect time ≤9s st opw atc
6 h Pass
Ater splicing tension testing: ≥1.96 N t esti ng
7 functi on Pass

testing concl usi on: Pass

fi nal concl usi on  Pass-test Retest Depot repai r

QC si gnat ure tim e 16-Jan-2018

QA si gnature tim e 16-Jan-2018