Invensys’ own knowledge and design experience combines to create the most effective and flexible
environment control solutions. Using the latest technology to meet the requirements of a company’s The passive infra-red (PIR) unit senses
particular working conditions, we can provide a system of temperature and air quality control that brings that no one is in the room and signals
to the controller to reduce the room
instant benefits to the building’s occupants, and sets new standards in climate management in the workplace.
temperature to save energy. When the
room is re-occupied the heating is
boosted to the set level.
■ Excellent performance
■ Cost-effective solutions
■ Easy to upgrade
New
Bonsai® Valves VAV Controller with Integral Actuator
Bonsai is a small, high performance fan coil control loop solutions. The This Invensys design comprises a LONMARK compliant
revolutionary valve design, with configurable kv settings, delivers fast, heating/cooling controller, actuator and patented
accurate response, blockage-reduced operation and superior reliability. pressure sensor all in one dedicated unit. While
Bonsai is simple to install, can be re-configured in the field and gives providing highly efficient air circulation and accurate
unrivalled environmental control. environment control, the units are quick to install,
The innovative two-part cartridge gives superb shut-off, effective balanced creating a cost-effective solution by reducing both
by-pass and is self-cleaning. Its design requires very little torque to operate installation and maintenance costs.
the valve, so the small, proportionally controlled drive actuator achieves Design benefits include:
great energy savings. ■ Complete control loop in one unit
■ Long term accuracy
■ Reduced inventory
■ Commissioning tools for simple set-up
Bonsai features an ingenious clip-on Kv settings control, reducing the flow Stylish LCD Sensors interface with your system
and bypass area to create different Kv values. Setting the required Kv is
The MN sensor provides a simple user interface with the
easily achieved by clipping the appropriate snap-fit coloured clip to the
controller or building management system. Available in
valve. A manual positioning lever is provided for easy override and
five stylish options, the modern design suits a range of
hydraulic commissioning.
interiors, while the inbuilt LCD screen makes it easy to
select room temperature, fan speed, operating mode,
or emergency heat.
The simple sensor design offers unique benefits:
■ Two wire installation
■ Sensors can be swapped without any
Bonsai offers a range of benefits:
■ Kv can be configured on site complicated re-engineering
■ Reduced blockage ■ Data can be shared between controllers
Our design options mean that you can select the right controller for the
job, from basic LON to multi-featured NCP units, without wasting unused
I/O capacity. Designed to meet specific applications, each has its own
control strategy function to maximise energy efficiency. These are based
on the latest EN standard drafts to meet CEN requirements.
Controllers can run in any of three operating modes, ‘Comfort, Economy
104mm or Night (off)’. In ‘Night’ operation the room temperature is monitored for
Valve open
a frost temperature condition to provide maximum protection to the
Valve open building. For added flexibility the controllers can be used as standalone or
Patents applied for: networked to a building management system.
GB0012541, US09/310935,
EP99303777, CN01802150
Height The range is designed to offer:
104mm ■ Competitive solutions (you only pay for what you need)
■ Reduced installation and commissioning time
■ A choice of LON or NCP controllers
Matching customer’s needs with flexible solutions
We offer a comprehensive range of products so whatever the application, we have
a controller to match, creating a total solution tailored to specific needs.
Variable Air Volume (VAV) Applications Fan Coil and Terminal Unit Applications
Standalone or Networked LON controller/actuators Standalone or Networked NCP and LON controllers
Application Type Application Control Fan Fan
on/off 1/2/3
Sensor sharing T T T
Open plan offices need only
one sensor
DNN
Actuator slaving Open plan offices need only
one controller
IC-LON
Automated maintenance Demonstrates and ensures
and commissioning optimum performance
CZU Controller The CZU is an electronic modulating controller for Controller Inputs/outputs Comms.
terminal units or fan coils in air-conditioning systems CZU 4201 1 x DI, 1 x UI, 3 x DO None
serving small zones of buildings such as individual
offices and hotel bedrooms. Controller requires a Data Sheet 2.201
24Vac supply.
MN Controllers This range of MicroNet Controllers are interoperable, Controllers Inputs/outputs Comms.
LONMARK® compliant units. When loaded with an MNL-5RF2 1 x DI, 1 x UI, 3 x DO LONWorks
application from WorkPlace Tech Tool they provide MNL-10RF2 1 x DI, 2 x UI, 4 x DO
control for packaged fan coils and similar applications. MNL-15RF2 3 x UI, 2 x DO, 2 x AO
Controllers require 24Vac supply. MNL-20RF2 2 x DI, 3 x UI, 6 x DO, 2 x AO
Data Sheets 10.070, 10.100
UniFact® Pro UniFact Pro terminal unit controllers have been Controllers Type Inputs/outputs Comms.
Controllers designed to meet virtually any fan-coil heating/cooling URC-41N-100 on/off fan control (4-pipe) 2 x DI, NCP
application. A voltage-free input (a timer switch, digital URC-41N-101 ” (2-pipe) 1 x RI (temp),
room sensor or passive infra-red sensor) can be used to URC-41N-102 ” (DX cooling/electric heater) 1 x AI (setpoint),
Controllers
switch between the two modes. A second voltage-free URC-41N-103 ” (airside control) 4 x DO triacs
digital input is available for connection to a thermostat URC-51N-100 3-speed fan control (4-pipe) 3 x DO relays
for automatic changeover between cooling and heating URC-51N-101 ” (2-pipe)
modes for 2-pipe fan coil unit (FCU) applications. The URC-51N-102 ” (DX cooling/electric heater)
controller meets all the latest CEN application URC-51N-103 ” (airside control)
requirements and offers low cost engineering without Data Sheet 10.130
maintenance. Controllers require 230Vac supply.
Accessories: Infra-red/RS 232 Receiver, NCP Palm Commissioning Software
Bonsai® Controllers Bonsai controllers are dedicated unit for Bonsai valves. Controllers Type Inputs/outputs Comms.
(Pro and Lite) The control loop offers incredible performance Bonsai Pro (networkable) 2 x DI, 1 x DI (temp), NCP
features and can be programmed locally or connected BRC-41N-100 on/off fan control (4-pipe) 1 x AI (setpoint),
to Invensys Sigma or MicroNet if required (Bonsai Pro). BRC-41N-101 ” (2-pipe) 1 x DO triacs (-101 only),
Alternatively it can be left to function standalone BRC-51N-100 3-speed fan control (4-pipe) 3 x DO – relays,
(Bonsai Lite). The controllers meet all the latest CEN
BRC-51N-101 ” (4-pipe) 2 x Bonsai outputs
application requirements and offers low cost
engineering without maintenance. Plug-in connectors, Bonsai Lite (standalone) 2 x DI, 1 x DI (temp), None
colour coding and standard built-in applications make BRC-41N-500 on/off fan control (4-pipe) 1 x AI (setpoint),
them simple to install, commission and maintain. BRC-41N-501 ” (2-pipe) 1 x DO triacs (-501 only),
BRC-51N-500 3-speed fan control (4-pipe) 3 x DO – relays,
Bonsai Pro are 230Vac controllers and have onboard
BRC-51N-501 ” (4-pipe) 2 x Bonsai outputs
fan switching relays. Bonsai Lite controllers require
24Vac supply. Data Sheet 4.102
Accessories: Enclosures, Set-point adjustment module
MN VAV Controller This variable air volume (VAV) controller is an Controller Control Inputs/outputs Comms.
interoperable, LONMARK®-compliant device. It provides MNL-V3RV2 Cooling, series fan, 1 x DI, 1 x UI, LONWorks
control strategies for pressure independent terminal induction, parallel fan 3 x DO, 1 x AO,
boxes, with or without reheat capabilities. Controller 2 x TO
requires a 24Vac supply. Data Sheet 10.121
Accessories: conduit enclosure, flow balance software
MN VAV Controllers These VAV controllers are interoperable, LONMARK®- Controller Type Control Inputs/outputs Comms.
Controller / actuators
with integral actuator compliant devices with integral actuator. They provide a MNL-V1RV2 Integral actuator Cooling 1 x DI, 1 x UI LONWorks
wide range of control strategies for pressure (no reheat)
independent terminal boxes, with or without reheat MNL-V2RV2 Integral actuator Cooling, series 1 x DI, 1 x UI, LONWorks
capabilities. Both models provide manual override and
and fan and/or fan, induction, 3 x DO, 1 x AO
an integral patented pressure transducer. Controllers
reheat control parallel fan,
require 24Vac supply. time prop.
Data Sheet 10.121
Accessories: shaft adapter, conduit enclosure, flow balance software
Bonsai® Valves Bonsai valves are specifically designed for fan coil Valve/actuators Size/Kvs
applications; accurate, quiet and fast, they complement BFB 1500 15mm – 1.6, 2.0, 2.5 Kvs *
Actuator / valves
modern processor control outputs and easily integrate BFB 1516 15mm – 1.6 Kvs
into the total solution. The valves are used with a BFB 1520 15mm – 2.0 Kvs
dedicated Bonsai controller which supplies their power. BFB 1525 15mm – 2.5 Kvs * Kvs is determined by a
selectable Kv clip.
BFB 1501 15mm – 0.4, 0.6, 1.0 Kvs *
BFB 1504 15mm – 0.4 Kvs
BFB 1506 15mm – 0.6 Kvs
Accessory:
BFB 1510 15mm – 1.0 Kvs
1m actuator extension lead
Data Sheet 4.102
Digital Room Sensors This family of wall temperature sensors feature an S-link Sensor Type
communication protocol, which provides a simple two-wire MN-S1 Sensor only (no display)
interface for power and exchange of sensor and sub-base MN-S2 with override
information. These include selecting set-point, fan speed, MN-S3 with setpoint adjustment and override
operating mode, or emergency heat. Available in six models, MN-S4 with setpoint, override and controller mode functions
these sensors provide an integral analogue-to-digital conversion MN-S4-FCS with setpoint, on/off and fan speed functions
for elimination of sensor-to-controller noise effects and wire Data Sheet 10.000
resistance offset. Sensor Range - 0...50°C
Accessories: aluminium, plastic & wire guards, covers, designer inserts
Sensors
Room Sensors These temperature sensors are specifically used with UniFact Pro, Sensor Type
Bonsai Pro and Bonsai Lite controllers. Models have light that DU 4301 Sensor only (blank)
indicates when the controller is running and use the same single DUS 4302 with set-point adjustment
gang sized case. Data Sheet 1.020
Sensor Range - –5...+50°C
Accessory: guard kit
Duct Sensor The DDU temperature sensor is specifically designed for Sensing range Resistance at 20°C Fixing
use in return air space of terminal units. DDU 0001 –5...+40°C 5573Ω Direct
(non adjust.)
Data Sheet 1.030
URC-41N-101
URC-41N-102
URC-41N-103
URC-51N-100
URC-51N-101
URC-51N-102
URC-51N-103
BRC-41N-100
BRC-41N-101
BRC-51N-100
BRC-51N-101
BRC-41N-500
BRC-41N-501
BRC-51N-500
BRC-51N-501
MNL-V1RV2
MNL-V2RV2
MNL-V3RV2
MNL-11RF2
MNL-13RF2
CZU 4201
Networkable ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Standalone ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
2-pipe ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
2-pipe auto changeover ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
4-pipe ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Air side control (4-pipe) ✓ ✓ ✓
Actuator slaving ✓
Sensor slaving ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Fan on/off ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Fan 3-speed control ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
On board transformer ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
On board relays 1 1 1 1 3 3 3 3 1 1 3 3 1 1 3 3 1 3
Output for electric heater ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
DX cooling ✓ ✓ ✓ ✓
Room sensors DRT ✓
DU ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
DUS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
S1 (S-Link) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
S2 ” ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
S3 ” ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
S4 ” ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
S4-FCS ” ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Duct sensors DDU ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Inbuilt-sensor
DDT ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ “
Actuator/valves AVU, FEU * ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Integral
BFB (Bonsai) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ actuator
AVUE * “ ✓
MVT, BVT * “ ✓
* These products are not shown in this brochure, please see data sheet for further information. AVU - DS 3.010, FEU - DS 4.101, AVUE - DS 3.001, MVT , BVT
These products are complemented by a full range of: Valves – an extensive family of 2, 3 and 4-port valves for water,
Actuators – model types are available for linear, rotary, unit, thermic media and steam applications. These range from small 15mm unit
and zone valves. Advanced models give improved performance, types to large 150mm flanged valves.
sensitivity, speed and built-in intelligence. Sensors – a stylish range of high performance sensors gives accurate
readings of air, water, flow, pressure, solar and outside temperature.
Chilled Ceilings
We can offer a range of range of water or air cooled chilled ceiling
systems, and active or passive chilled beams, which provide noise free,
draught free radiant cooling for new or retro-fit installations.
Management Systems
Invensys has developed two fully scalable management systems based
on world standard platforms and open communication protocols;
● MicroNet Management System which is designed for small
to large sized buildings
● Invensys Sigma for large complexes requiring extensive
management reporting, energy saving/maintenance programs
and third party equipment integration.
Training
Invensys Climate Controls Europe is part of the Energy
We hold regular training courses at our worldwide training centres or
Management Division of Invensys Group Plc, the worldwide leader
on site, providing staff with a good working knowledge, practical
in electronics and engineering.
experience and awareness of our products and systems.
Invensys Climate Controls Europe has been formed through the
merger of Invensys Building Systems Europe (formerly Satchwell
Customer Care Centre
Controls Systems) and Climate Controls Europe. It brings together
The Centre’s aim is to provide a single point of contact for customers
the expertise of both companies in the design and manufacture of
regardless of the nature of their enquiry. Advanced routing
energy efficient products and systems for controlling, measuring
technology and dedicated telephone numbers ensure that all queries
and monitoring HVAC plant in industrial, commercial and
are resolved quickly and efficiently.
residential buildings, along with Climate Controls’ portfolio of
commercial refrigeration control products.
Engineering
The UK Engineering Division has full comprehensive project Invensys Climate Controls Europe is able to offer its customers the
management capability for engineering and designing turn-key benefits of expanded research and development programmes,
and bespoke systems, including installation and commissioning, standardised product platforms, strengthened distribution, and
in partnership with major contractors. world class service.