GEA Tuchenhagen Hygienic Centrifugal Pumps

Business Line Hygienic Pump Technology


Catalog 2014

engineering for a better world GEA Mechanical Equipment


Publication date: 1/1/2014
The publication of specifications, technical data and information in written or electronic form does not release the user
from the responsibility of checking for themselves all products delivered by us for suitability for the application(s)
intended. These may be subject to change without prior notification. Errors and printing errors excepted - we assume
no liability for the correctness of specifications given.
The general sales terms and conditions for GEA Tuchenhagen GmbH.

All rights reserved - copyright on all contents:

GEA Tuchenhagen GmbH


Am Industriepark 2-10, 21514 Büchen, Germany
Registered Office: Büchen, Court of Registration: Lübeck, HRB 836 SB
Management office: Dipl.-Kfm. Franz Bürmann
Sales tax identification number: DE 812589019
Table of Contents Pages

Introduction 5-7
Description of TP and TPS 8-9
Overview of centrifugal pumps 10 - 11
Performance characteristics, TP 50 Hz 12
Performance characteristics, TP 60 Hz 13

2-pole
Example of a TP standard version 14 - 15

50 Hz
TP standard version 50 Hz, 2-poles 16 - 35

4-pole
50 Hz
Example of a TP standard version 36 - 37

Standard TP
TP standard version 50 Hz, 4-poles 38 - 57

2-pole
Example of a TP standard version 58 - 59

60 Hz
TP standard version 60 Hz, 2-poles 60 - 79

4-pole
60 Hz
Example of a TP standard version 80 - 81
TP standard version 60 Hz, 4-poles 82 - 101

2-pole
Performance characteristics, TPS 50 Hz 102

50 Hz
Standard TPS
Performance characteristics, TPS 60 Hz 103
Example of a TPS standard version 104 - 105
TPS standard version 50 Hz, 2-poles 106 - 109
2-pole
60 Hz

Example of a TPS standard version 110 - 111


TPS standard version 60 Hz, 2-poles 112 - 115
Options

Options for TP and TPS series 116 - 119


Spare Parts

Spare parts for TP and TPS series 120

Pumps - Checklist 121


General Sales Terms and Conditions 122
4
GEA Tuchenhagen
GEA Flow Components

Our Business Unit The GEA Group


GEA Flow Components Every second litre of beer brewed in the world may well have flown through
a component supplied by GEA Group. About every fourth litre of milk is
Our main focus is on the growth and extracted or further processed with equipment produced by
GEA Group. One third of the worldwide instant coffee is produced in
further strengthening of our market GEA Group systems – with sales of more than four billion euros, the group
position as an internationally is one of the largest suppliers of process machinery and technology in the
world.
recognized technology leader in GEA Group comprises four segments. The GEA Flow Components business
components for the food, unit is part of the GEA Mechanical Equipment segment, together with the
business units Mechanical Separation, Food Solutions and Homogenizer.
pharmaceutical and biotechnology
industries – mainly in the business
areas of valves, pumps and cleaning
technology.
The Business Unit GEA Flow Components
consists of:
GEA Tuchenhagen in Büchen (Germany), GEA Aseptomag in Kirchberg
(Switzerland) and GEA Breconcherry in the UK as well as various locations
in the USA, Canada, China, India, Poland and France

Our four Business Lines – for erverything that flows

Hygienic Valve Technology Cleaning Technology


GEA Tuchenhagen GEA Breconcherry

Hygienic Pump Technology Aseptic Valve Technology


GEA Tuchenhagen GEA Aseptomag

5
Business Line Hygienic Pumps

Our Mission Economically efficient


The current generation of GEA Tuchenhagen®-VARIFLOW
GEA Tuchenhagen products meet the growing pumps provide users with considerable cost savings.
demand for environmentally compatible
Sensibly rated high-efficiency motors in every dimension needed
components. Our basis for this is a are available to cover the typical requirements of the markets.
future-oriented corporate and product concept They enable that energy consumption is kept as low as possible,
which means a positive impact on your profitability.
committed to economic efficiency,
sustainability and service-orientation.

Hygienic design
Carefully designed flow paths free from dead corners enable
optimum utilization of the conveying energy. The product is
conveyed evenly and gently, resulting in a higher product
quality, which provides the user with improved processing
options and distribution potentials. The cleaning requirement is
considerably reduced as far as time, water and resources are
concerned, with a positive impact on production planning and
cost accounting.

Economically
• High product quality
• Reduced consumption of energy,
water and cleaning media
• Saves time in maintenance and cleaning

6
Business Line Hygienic Pumps

Sustainable Service-oriented
Lower consumption of energy, water and chemicals means Plant designers and engineering companies appreciate the
less load on environment and climate. For GEA Tuchenhagen benefits offered by GEA Tuchenhagen: they cannot only profit
users, the future success of their business, and the continuing from a range of highly efficient products but also use the
acceptance of their production site this aspect will become more individually tailored engineering support available from
and more important. GEA Tuchenhagen.

On many markets, ecological criteria and the quality seals Maintenance service offers which protect your investment
introduced for them increasingly determine retail assortment enable that the necessary service work on GEA Tuchenhagen
planning and what consumers will buy. components can be carried out with just minor interruptions in
Users of GEA Tuchenhagen products will not only be at an production processes individually tailored to the customer’s
advantage due to production processes which have proven to be requirements.
environmentally friendly but also as a result of their maximum
hygiene and care when processing their products.

This helps users to fulfil their own commitment to sustainable


working methods – the best way towards a secure future!

Sustainable Service-orientated

• Less load on climate and environment • Individual engineering support


• Environmental orientation production methods • Life cycle cost calculations
• Maximum hygiene and care in product processing • Minor production interruptions
• Tailor made service concepts

7
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps

The GEA Tuchenhagen®-VARIFLOW Centifugal Pump TP is


Applications
designed for pumping demanding media up to a viscosity of
1,000 mPas. Low flow velocities and gentle discharge of media • Breweries
through the spiral housing ensure extremely gentle product Beer, wort, yeast, water, CIP solutions
handling and high efficiency. • Dairies
10 pump sizes with a capacity range of up to 210 m3/h and Milk, cream, yoghurt, whey, brine, CIP solutions
pump heads of up to 90 m w.c. are available, finely tuned to the
• Food
task at hand.
Oils, sauces, stock, brine, flavours, ice-cream mix,
CIP solutions
• Pharmaceuticals/Cosmetics
Ultra-pure water, extracts, emulsions, WFI water, distillates
• Fields of applications TP
Conveying, circulation, pressure boosting, filling lines,
filling, emptying, filtration, evaporation, cleaning
• Fields of applications TPS
CIP solutions, tank emptying, gas conveying

The spiral housing for the TP series is made of cold-rolled steel.


Technical benefits
This material has an excellent surface quality, which is essential
for optimum cleaning in CIP/SIP processes. Wall thicknesses of • Operating pressure max. 16 bar
6 mm provide high strength for critical piping configurations
• Low NPSH value avoids early cavitation to the pump
and high inlet pressures.
• The pumping characteristic can be adapted to the
requirements of your system by speed control or
impeller trimming

By combining the existing TP series with an upstream screw Constructive characteristics


rotor stage a new generation of hygienic self-priming centrifugal
pumps has been created. • Open impeller design
• All parts stainless steel, wetted components made of
1.4404 or 1.4409 (AISI 316L)
• Surface roughnesses of Ra ≤ 0.8 µm can be achieved by
mechanical treatment of the surface (higher surface
qualities on request)
• Driven by premium efficiency IE3 motors,
design type IM B35, according to IEC

Special Features
The GEA Tuchenhagen®-VARIFLOW Centrifugal Pump TPS is
• Gentle product handling
a self-priming pump for viscosities of up to 500 mPas. The pump
is used for CIP return applications, for emptying tanks as well as • Standard connection: DIN 11853-2 Hygienic flange
for conveying products containing gas. • Low wear part stock requirement
The TPS is characterized by a low sound power level, highest • Acceptance test certification 3.1 (optional)
efficiency and excellent cleaning properties. The TPS series also
• EHEDG approved and certified
permits evacuation of pipes on the suction side – so that just one
pump is required for CIP return and product conveying! • Sealings comply to FDA and USP Class IV

8
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps

Sealing according to the VARIVENT® principle


The special groove enables the seal is kept reliably in
place at all times. The shape of the groove is based on
FEM analyses. The metallic stop allows a defined
compression of the seal, ensuring gap-free sealing
against the product chamber without dead corners.

O-ring sealing between pump FEM showing the seal ring in


housing and cover operating mode

Centrifugal Pump TP
1 Pump cover
13
Centrifugal Pump TP
Centrifugal Pump TPS
12
2 Clamp connection 11
3 Rotor housing cover 8

4 Circulation pipe 10

5 Front rotor
6 Rotor housing 7 9
1

Centrifugal Pump TP/TPS


7 Impeller
8 Mechanical seal
9 Sealing according to VARIVENT® principle
10 Pump housing
11 One-piece lantern
12 Pump shaft without key 12

13 Motor 10
13
11
8

Centrifugal Pump TPS


5
4
3
7 9
6
9
4

9
GEA Tuchenhagen
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps, Series TP and TPS

Program overview

non self-priming

TP 1020 TP 1540 TP 2030 TP 2050 TP 2575

max. flow rate [m³/h] 20 35 36 36 40


2-pole, 50 Hz

max. pump head [m] 24 42 36 60 85

Motor rating [kW], 2-pole 1.1 - 5.5 3.0 -15.0 1.5 - 11.0 3.0 - 15.0 5.5 - 30.0

max. flow rate [m³/h] 10 19 19 19 20


4-pole, 50 Hz

max. pump head [m] 6 11 9 15 21

Motor rating [kW], 4-pole 0.75 - 3.0 0.75 - 3.0 0.75 - 5.5 0.75 - 4.0 3.0 - 7.5

max. flow rate [m³/h] 24 44 44 42 48


2-pole, 60 Hz

max. pump head [m] 34 62 52 85 130

Motor rating [kW], 2-pole 1.25 - 5.5 3.0 - 15.0 1.5 - 11.0 3.0 - 15.0 5.5 - 30.0

max. flow rate [m³/h] 11 22 23 21 22


4-pole, 60 Hz

max. pump head [m] 8 15.5 13 22 31

Motor rating [kW], 4-pole 0.75 - 2.2 0.75 - 4.0 0.75 - 5.5 0.75 - 4.0 4.0 - 7.5

Impeller diameter [mm] 80 - 130 130 - 180 110 - 160 160 - 210 200 - 250

min. NPSH [m] (2,900 min-1) 1.0 1.0 1.0 1.0 1.0

max. viscosity [mPas] 1,000 1,000 1,000 1,000 1,000

10
GEA Tuchenhagen
GEA Tuchenhagen®-VARIFLOW Centrifugal Pumps, Series TP and TPS

non self-priming self-priming

TP 3050 TP 5060 TP 7060 TP 8080 TP 16040 TPS 2030 TPS 3050

75 75 110 120 210 32 52

65 75 74 90 49 37 64

3.0 - 22.0 5.5 - 30.0 7.5 - 30.0 11.0 - 37.0 11.0 - 45.0 2.2 - 11.0 3.0 - 22.0

36 40 55 65 100 n.a. n.a.

16 17 19 23 12 n.a. n.a.

0.75 - 7.5 2.2 - 7.5 2.2 - 7.5 4.0 - 7.5 3.0 - 7.5 n.a. n.a.

85 80 120 125 240 36 69

95 110 105 130 70 52 95

3.0 - 22.0 5.5 - 30.0 7.5 - 30.0 11.0 - 45.0 11.0 - 45.0 2.2 - 11.0 3.0 - 22.0

42 45 65 75 120 n.a. n.a.

24 24 27 34 17 n.a. n.a.

0.75 - 7.5 2.2 - 7.5 2.2 - 7.5 4.0 - 7.5 4.0 - 7.5 n.a. n.a.

140 - 210 155 - 225 155 - 225 180 - 250 160 - 200 110 - 160 140 - 210

0.8 0.9 1.0 1.2 3.8 0.8 0.8

1,000 1,000 1,000 1,000 1,000 500 500

11
GEA Tuchenhagen
Performance characteristics 50 Hz, GEA Tuchenhagen®-VARIFLOW, Series TP

2-pole (n = 2,900 min-1)


30 40 50 100 200 300 400 500 800 1000
USGPM
20 30 40 50 100 200 300 400 500 700 900
100 IGPM

TP 2575-2 TP 8080-2
TP 5
060-
TP 2050-2 2
50

TP
70
40 TP 1540-2

60
-2
TP 3050-2
30 TP 2030-2

TP 16040-2
20

H TP 1020-2
[m] 10

50 Hz n = 2,900 min-1
1
1 10 20 30 40 50 100 200 300

Q [m3/h]

4-pole (n = 1,450 min-1)


30 40 50 100 200 300 400
USGPM
20 30 40 50 100 200 300 400
30 IGPM

20 TP 2575-4 TP 8080-4
TP 5 TP
TP 2050-4 060 706
-4 0-4
10 TP 1540-4

H TP 1540-4 TP 3050-4
[m] TP 16040-4
5

1
TP 1020-4 TP 2030-4

50 Hz n = 1,450 min-1
1 10 20 30 40 50 80 100
Q [m3/h]

12
GEA Tuchenhagen
Performance characteristics 60 Hz, GEA Tuchenhagen®-VARIFLOW, Series TP

2-pole (n = 3,500 min-1)


30 40 50 100 200 300 400 500 800 1200
USGPM
20 30 40 50 100 200 300 400 500 700 1000
IGPM
150

100 TP 2575-2
TP 5060-2 TP
TP 80
70 80
TP2050-2 60 -2
-2

TP 1540-2
50
TP 3050-2
TP 2030-2
40
TP 16040-2

30

H
[m] 20

TP 1020-2

10

60 Hz n = 3,500 min-1
1
1 10 20 30 40 50 70 100 200 300

Q [m3/h]

4-pole (n = 1,750 min-1)


30 40 50 100 200 300 400 500 600
USGPM
20 30 40 50 100 200 300 500
40 IGPM

30
25 TP 2575-4 TP 8080-4
TP 5
060-
4
20 TP 2050-4

TP 1540-4 TP 7060
TP 3050-4
10
TP 16040-4
H
[m]
5

TP 1020-4 TP 2030-4
3

1
60 Hz n = 1,750 min-1
1 10 20 30 40 50 100 140
Q [m3/h]
13
GEA Tuchenhagen
Standard version, centrifugal pump type TP, 2-poles (n=2,900 min-1), 50 Hz

Standard version 2 pole/50Hz


Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Depending on pump size
Mechanical seal Single-acting, material: C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Standard equipment Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 210 m3/h
Pump head max. 90 m w.c.

TP 1020 TP 1540 bis TP8080 TP 16040

30 40 50 100 200 300 400 500 800 1000


USGPM
20 30 40 50 100 200 300 400 500 700 900
100 IGPM

TP 2575-2 TP 8080-2
TP 5
060-
TP 2050-2 2
50
TP
70

40 TP 1540-2
60
-2

TP 3050-2
TP 2030-2
Performance characteristics TP

30

TP 16040-2
20

H TP 1020-2
[m] 10

n = 2,900 min-1
1
1 10 20 30 40 50 100 200 300

Q [m3/h]
14
GEA Tuchenhagen
Example of a standard selection

Code T P 0 1 0 2 0 2 5 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Standard version, for other versions see options

Example Pos Designation Code of selection characteristics


TP01020 1. Type TP01020 Selected values
2 2. Speed 2 = 2 pole determined by the
pump selected
50 3. Frequency 50 = 50 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
011 5. Motor power 011 = 1.1 kW (IEC 80)
015 = 1.5 kW (IEC 90S) Selection using the
022 = 2.2 kW (IEC 90L) characteristic curves
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)

2-pole
50 Hz
055 = 5.5 kW (IEC 112M)

Standard TP
Performence curves, centrifugal pump, TP 1020 (2-pole / 50 Hz)
H 0 10 20 30 40 50 60 70 80
USGPM
[ft] [m]
0 10 20 30 40 50 60 70
IGPM
80 24 Ø130 η 0.25 η 0.30 η 0.35
η 0.40
η 0.45
22
70 Ø120 η 0.50
20

60 18
Ø110
Impeller diameter

16
50
14 Ø100

40 12
Ø90
10
30
Impeller selection in 8 Ø80
accordance with capacity
20
and pump head 6

4
10
Standard TPS

0
2

0
50 Hz
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
NPSH Q [m3/h]
Required NPSH-value

[ft] [m]
4.0 3.5
3.0 Ø80
3.0 Ø130
2.5
2.0 2.0
1.0
1.0
0.5
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P Q [m3/h]
[hp] [kW]
1.6
2.0
1.4 Ø130
1.8
Required motor power

1.6 1.2
1.4 Ø120
1.0
1.2 Ø110
0.8
1.0 Ø100
Motor output selection in 0.8 0.6 Ø90
accordance with capacity 0.6 Ø80
and pump head 0.4
0.4
0.2
0.2

0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Q [m3/h]

15
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 20 m³/h
Pump head max. 24 m w.c.
Housing pressure max. 10 bar

Code T P 0 1 0 2 0 2 5 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01020 1. Type TP 1020
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
011 5. Motor power 011 = 1.1 kW (IEC 80)
015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)

TP 1020
Motor size b c** d f h m n p t* u v w x y*
80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.5
90S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5
100L / 112M 602 474/496 154 335 403 76 278 160 25.5 112 125 85 14 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

16
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 2-pole (n=2,900 min-1), 50 Hz

H 0 10 20 30 40 50 60 70 80
USGPM
[ft] [m]
0 10 20 30 40 50 60 70
IGPM
80 24 Ø130 η 0.25 η 0.30 η 0.35
η 0.40
η 0.45
22
70 Ø120 η 0.50
20

60 18
Ø110
16
Impeller diameter

50
14 Ø100

2-pole
50 Hz
40 12
Ø90
10
30
8 Ø80

Standard TP
20 6

4
10

0
2

0
50 Hz
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
NPSH Q [m3/h]
[ft] [m]
4.0 3.5
Required NPSH-value

3.0 Ø80
3.0 Ø130
2.5
2.0 2.0
1.0
1.0
0.5
0 0 Standard TPS
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P Q [m3/h]
[hp] [kW]
1.6
2.0
1.4 Ø130
1.8
1.6 1.2
Required motor power

1.4 Ø120
1.0
1.2 Ø110
0.8
1.0 Ø100
0.8 0.6 Ø90
0.6 Ø80
0.4
0.4
0.2
0.2

0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Q [m3/h]

The flow charts are based on a pumping medium of:


densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

17
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 35 m³/h
Pump head max. 42 m w.c.
Housing pressure max. 16 bar

Code T P 0 1 5 4 0 2 5 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01540 1. Type TP 1540
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
130 4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm
30 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)

TP 1540
Motor size b c** d f h m n p t* u v w x y*
100L 608 480 152 335 403 90 278 160 25.5 112 140 85 42 25.5
112M (4 kW + 5.5 kW) 608 502 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5
112M (7.5 kW) 608 524 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5
132M (9.0 kW + 11 kW) 709 619 152 410 444 90 332 216 25.5 132 140 85 42 25.5
132M (15 kW) 709 670 152 410 444 90 332 216 25.5 132 140 85 42 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

18
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 2-pole (n=2,900 min-1), 50 Hz

H 0 20 40 60 80 100 120 140 160


USGPM
[ft] [m]
0 20 40 60 80 100 120 140
44 IGPM
140 Ø180
40
η 0.57
Ø170
120 36
Ø160 η 0.55
32
100 Ø150
28
Impeller diameter

Ø140
80 24

2-pole
η 0.50

50 Hz
Ø130
20 η 0.45
60
16 η 0.40
η 0.35
40 12
η 0.30

Standard TP
8
20

0
4

0
50 Hz
0 5 10 15 20 25 30 35 40
NPSH Q [m3/h]
[ft] [m]
20 6
Required NPSH-value

5
15 Ø130 Ø180
4
10 3
2
5
1
0 0
0 5 10 15 20 25 30 35 40
P Q [m3/h]
[hp] [kW]
Standard TPS
6.5

8 6.0
Ø180
5.5
7
Required motor power

5.0
Ø170
6 4.5
Ø160
4.0
Ø150
5 3.5

4 3.0 Ø140
2.5 Ø130
3
2.0

2 1.5
1.0
1 0 5 10 15 20 25 30 35 40
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

19
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 36 m³/h
Pump head max. 36 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 3 0 2 5 0 D N N F K 0 5 0 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02030 1. Type TP 2030
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm
145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm
015 5. Motor power 015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)

TP 2030
Motor size b c** d f h m n p t* u v w x y*
90S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5
100L 606 478 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5
112M (4 kW + 5.5 kW) 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5
112M (7.5 kW) 606 522 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5
132M 707 617 152 410 444 85 332 216 25.5 132 135 85 40 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

20
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 2-pole (n=2,900 min-1), 50 Hz

H 0 20 40 60 80 100 120 140 160


USGPM
[ft] [m]
0 20 40 60 80 100 120 140
44 IGPM
140
40
Ø160 η 0.30 η 0.35 η 0.40 η 0.45 η 0.50 η 0.55
120 36
Ø150 η 0.60

2-pole
50 Hz
32
Impeller diameter

100
28 Ø140

80 24 Ø130

Ø120
20
60

Standard TP
16 Ø110

40 12

8
20

0
4

0
50 Hz
0 5 10 15 20 25 30 35 40
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

20 6
5
15 Ø110 Ø160
4
10 3
2
Standard TPS
5
1
0 0
0 5 10 15 20 25 30 35 40
P Q [m3/h]
[hp] [kW]
5.0
Required motor power

4.5 Ø160
6.0
4.0
Ø150
5.0
3.5
Ø140
4.0 3.0
2.5 Ø130
3.0 Ø120
2.0 Ø110
2.0 1.5
1.0
1.0 0 5 10 15 20 25 30 35 40
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

21
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 36 m³/h
Pump head max. 60 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 5 0 2 5 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02050 1. Type TP 2050
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
160 4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm
190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)

TP 2050
Motor size b c** d f h m n p t* u v w x y*
100L 622 494 136 335 403 107 278 160 25.5 112 161 85 52 25.5
112M (4 kW + 5.5 kW) 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5
112M (7.5 kW) 622 538 136 335 403 107 278 190 25.5 112 161 85 52 25.5
132M (9.0 kW + 11 kW) 723 633 156 410 444 107 332 216 25.5 132 161 85 52 25.5
132M (15 kW) 723 684 156 410 444 107 332 216 25.5 132 161 85 52 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

22
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 2-pole (n=2,900 min-1), 50 Hz

H 0 25 50 75 100 125 150


USGPM
[ft] [m]
0 25 50 75 100 125
250 IGPM
70
Ø210
η 0.40
η 0.45 η 0.50
200 60
Ø200 η 0.52

2-pole
50 Hz
η 0.52
Ø190
Impeller diameter

50 Ø175 η 0.50
150 Ø180
40 Ø170
η 0.45
Ø160
100 30

Standard TP
η 0.40 η 0.45
η 0.45
20
50
10
50 Hz
0 0
0 5 10 15 20 25 30 35
NPSH Q [m3/h]
[ft] [m]
10 3
Required NPSH-value

2.5
7.5 Ø210
2 Ø160

5 1.5

1
2.5
Standard TPS
0.5

0 0
0 5 10 15 20 25 30 35
P Q [m3/h]
[hp] [kW]
10
Ø210
12.5
Required motor power

7.5 Ø200
10

Ø190
7.5
5 Ø180

5 Ø170
Ø160
2.5
2.5

0 0
0 5 10 15 20 25 30 35
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

23
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 40 m³/h
Pump head max. 85 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 5 7 5 2 5 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02575 1. Type TP 2575
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
200 4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm
225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm
245 = 245 mm 250 = 250 mm
055 5. Motor power 055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)

TP 2575
Motor size b c** d f h m n p t* u v w x y*
112M (5.5 kW / 7.5 kW) 621 515/537 138 335 403 124.5 278 190 25.5 112 190 85 48.5 25.5
132M (9.0 kW + 11 kW) 720 630 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5
132M (15 kW) 720 681 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5
160L 894 782 191 640 598 124.5 412 254 25.5 160 190 110 48.5 25.5
200L 1,033 908 200.5 810 668 124.5 472 318 25.5 200 190 115 48.5 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

24
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 2-pole (n=2,900 min-1), 50 Hz

H 0 20 40 60 80 100 120 140 160 180


USGPM
[ft] [m]
0 20 40 60 80 100 120 140 160
92 IGPM
280 Ø250 η 0.35
η 0.40 η 0.44
80 Ø240
η 0.46

2-pole
50 Hz
240 72 Ø230 η 0.46
Ø220 η 0.44
64
Ø210
Impeller diameter

200
η 0.48
56 Ø200

160 48
η 0.35

Standard TP
η 0.40
40
120
32 η 0.44

80 24

16
40

0
8

0
50 Hz
0 5 10 15 20 25 30 35 40 45
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

10 3
Ø250
Ø200
7.5
2
5
Standard TPS
1
2.5

0 0
0 5 10 15 20 25 30 35 40 45
P Q [m3/h]
[hp] [kW]
16
Ø250
20 14
Required motor power

12 Ø240
16
10 Ø230
12 Ø220
8
Ø210
8.0 6 Ø200
4
4.0
2
0 0
0 5 10 15 20 25 30 35 40 45
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

25
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 75 m³/h
Pump head max. 65 m w.c.
Housing pressure max. 16 bar

Code T P 0 3 0 5 0 2 5 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP03050 1. Type TP 3050
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
140 4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)

TP 3050
Motor size b c** d f h m n p t* u v w x y*
100L 618 504 134 335 403 103 278 160 25.5 112 155 85 50 25.5
112M (4 kW + 5.5 kW) 618 515 134 335 403 103 278 190 25.5 112 155 85 50 25.5
112M ( 7.5 kW) 618 534 134 335 403 103 278 190 25.5 112 155 85 50 25.5
132M (9.0 kW + 11 kW) 719 629 154 410 444 103 332 216 25.5 132 155 85 50 25.5
132M (15 kW) 719 680 154 410 444 103 332 216 25.5 132 155 85 50 25.5
160L 893 781 189 640 598 103 412 254 25.5 160 155 110 50 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

26
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 2-pole (n=2,900 min-1), 50 Hz

H 0 50 100 150 200 250 300 350


USGPM
[ft] [m]
0 50 100 150 200 250 300
250 IGPM
70 Ø210 η 0.45
η 0.40 η 0.50 η 0.55

200 60 Ø200 η 0.60


η 0.61
Ø190
50 Ø18
705 η 0.60

2-pole
50 Hz
150 Ø170 η 0.55
Impeller diameter

40 η 0.50
Ø160
η 0.45
Ø150
η 0.40
100 30 Ø140

Standard TP
20
50
10
50 Hz
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
NPSH Q [m3/h]
[ft] [m]
20 6
Ø210
Required NPSH-value

Ø140
5
15
4

10 3

2
5
1 Standard TPS
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
P Q [m3/h]
[hp] [kW]
20
25
Required motor power

Ø210

20 15 Ø200

15 Ø190
10 Ø180
Ø170
10
Ø160
5 Ø150
5 Ø140

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

27
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 75 m³/h
Pump head max. 75 m w.c.
Housing pressure max. 16 bar

Code T P 0 5 0 6 0 2 5 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP05060 1. Type TP 5060
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
175 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
215 = 215 mm 220 = 220 mm 225 = 225 mm
055 5. Motor power 055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)

TP 5060
Motor size b c** d f h m n p t* u v w x y*
112M (5.5 kW / 7.5 kW) 622 517/538 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5
132M (9.0 kW + 11 kW) 723 633 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5
132M (15 kW) 723 684 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5
160L 897 785 192 640 598 114.5 412 254 27.5 160 230 110 52 25.5
200L 1,030 905 195 810 673 114.5 472 318 27.5 200 230 115 52 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

28
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 2-pole (n=2,900 min-1), 50 Hz

H 0 50 100 150 200 250 300 350


USGPM
[ft] [m]
0 50 100 150 200 250 300
300 90 IGPM

80 η 0.45
η 0.40
Ø225 η 0.50 η 0.55 η 0.58
250
70 Ø215 η 0.58
Ø205 η 0.55
200 60 η 0.62
Impeller diameter

Ø195
η 0.50

2-pole
50 Hz
Ø185 η 0.45
50
Ø175 η 0.40
150
40 Ø165
Ø155
100 30

Standard TP
20
50
10
50 Hz
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

5
Ø155 Ø225
15
4

10 3

2
5
1 Standard TPS
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
P Q [m3/h]
[hp] [kW]
30
20 Ø225
Required motor power

25 Ø215
Ø205
20 15
Ø195
Ø185
15
10 Ø175

10 Ø165
Ø155
5
5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

29
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 110 m³/h
Pump head max. 74 m w.c.
Housing pressure max. 16 bar

Code T P 0 7 0 6 0 2 5 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP07060 1. Type TP 7060
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
175 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm
220 = 220 mm 225 = 225 mm
075 5. Motor power 075 = 7.5 kW (IEC 112M)
092 = 9.0 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)

TP 7060
Motor size b c** d f h m n p t* u v w x y*
112M 622 538 132 335 427 110 278 190 27.5 112 230 85 56 25.5
132M (9.0 kW + 11 kW) 723 633 152 410 444 110 332 216 27.5 132 230 85 56 25.5
132M (15 kW) 723 684 152 410 444 110 332 216 27.5 132 230 85 56 25.5
160L 897 785 187 640 596 110 412 254 27.5 160 230 110 56 25.5
200L 1,030 905 190.5 810 668 110 472 318 27.5 200 230 115 56 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

30
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 2-pole (n=2,900 min-1), 50 Hz

H 0 100 200 300 400 500


USGPM
[ft] [m]
0 100 200 300 400
80 IGPM
Ø225 η 0.50 η 0.55 η 0.60
250
70 Ø215
η 0.65
Ø205 η 0.60
200 60
Ø195 η 0.66 η 0.55
Impeller diameter

50 Ø185 η 0.50
150 Ø175
40 Ø165

2-pole
50 Hz
Ø155
100 30

20
50
10
50 Hz

Standard TP
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

20
Ø155 Ø225
5
15
4

10 3
2
5
1

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
P Q [m3/h]
[hp] [kW] Standard TPS
30
Ø225
Required motor power

35
25
30 Ø215
20 Ø205
25
Ø195
20 15
Ø185
15 Ø175
10
Ø165
10
Ø155
5
5

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

31
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 120 m³/h
Pump head max. 90 m w.c.
Housing pressure max. 16 bar

Code T P 0 8 0 8 0 2 5 0 D N N F K 1 0 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP08080 1. Type TP 8080
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
180 4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm
230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm
250 = 250 mm
110 5. Motor power 110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
370 = 37.0 kW (IEC 200L)
450 = 45.0 kW (IEC 225M)

TP 8080
Motor size b c** d f h m n p t* u v w x y*
132M (11 kW / 15 kW) 742 652/703 156 410 444 124 332 216 27.5 132 250 85 71 25.5
160L 916 804 191 640 598 124 412 254 27.5 160 250 110 71 25.5
200L 1,050 925 195 810 668 124 472 318 27.5 200 250 115 71 25.5
225M 1,076 961 195 810 720 124 472 356 27.5 200 250 115 71 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

32
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 2-pole (n=2,900 min-1), 50 Hz

H 0 100 200 300 400 500 600


USGPM
[ft] [m]
0 100 200 300 400 500
110 IGPM
350
100 η 0.55
η 0.45 η 0.50 η 0.60
Ø250 η 0.40
300 90
Ø240 η 0.60
80 Ø230
η 0.64
250 Ø220 η 0.55
Impeller diameter

2-pole
50 Hz
70 η 0.66
Ø210 η 0.50

200 60 Ø200
Ø190
50 Ø180
150
40

Standard TP
100 30

20
50
10
50 Hz
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

5
15 Ø250
4
Ø180
10 3
2
5 Standard TPS
1

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
P Q [m3/h]
[hp] [kW]

40 Ø250
Required motor power

50 Ø240
Ø230
40 30 Ø220
Ø210
30
20 Ø200
20 Ø190
Ø180
10
10

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

33
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 210 m³/h
Pump head max. 49 m w.c.
Housing pressure max. 16 bar

Code T P 1 6 0 4 0 2 5 0 D N N F K 1 5 0 1 0 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP16040 1. Type TP 16040
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
160 4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm
180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm
200 = 200 mm
110 5. Motor power 110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
370 = 37.0 kW (IEC 200L)
450 = 45.0 kW (IEC 225M)

TP 16040
Motor size b c** d f h m n p t* u v w x y*
132M (11 kW / 15 kW) 752 662/713 151 410 444 108 332 216 29.5 132 280 85 86 27.5
160L 926 814 186 640 596 108 412 254 29.5 160 280 110 86 27.5
200L 1,059 934 189 810 668 108 472 318 29.5 200 280 115 86 27.5
225M 1,085 970 189 810 720 108 521 356 29.5 225 280 115 86 27.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

34
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 2-pole (n=2,900 min-1), 50 Hz

H 0 100 200 300 400 500 600 700 800 900


USGPM
[ft] [m]
0 100 200 300 400 500 600 700
IGPM

Ø200
160
50 η 0.50 η 0.55 η 0.60
η 0.65
Ø190 η 0.67
45
140 η 0.65
40

2-pole
Ø180

50 Hz
120
η 0.60
Impeller diameter

35
Ø170
100 30 η 0.55

Ø160
80 25
η 0.45 η 0.50
η 0.45

Standard TP
20
60
15
40
10

20

0
5

0
50 Hz
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

40 12
10 Ø200
30
8
20 6
4
10 Ø160
Standard TPS
2
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
P Q [m3/h]
[hp] [kW
45 35
Ø200
40 30
Required motor power

35
25 Ø190
30
20
25 Ø180

20 15 Ø170

15 Ø160
10
10
5
5
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

35
GEA Tuchenhagen
Standard version, centrifugal pump, type TP, 4-pole (n=1,450 min-1), 50 Hz

Standard version 4 pole/50Hz


Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Depending on pump size
Mechanical seal Single-acting, material: C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Standard equipment Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 100 m3/h
Pump head max. 23 m w.c.

TP 1020 TP 1540 bis TP8080 TP 16040

30 40 50 100 200 300 400


USGPM
20 30 40 50 100 200 300 400
30 IGPM

20 TP 2575-4 TP 8080-4
Performance characteristics TP

TP 5 TP
TP 2050-4 060 706
-4 0-4
10 TP 1540-4

H TP 1540-4 TP 3050-4
[m] TP 16040-4
5

TP 1020-4 TP 2030-4
2

n = 1,450 min-1
1
1 10 20 30 40 50 80 100
Q [m3/h]

36
GEA Tuchenhagen
Example of a standard selection

Code T P 0 1 0 2 0 4 5 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Standard version, for other versions see options

Example Pos Designation Code of selection characteristics


TP01020 1. Type TP01020 Selected values
4 2. Speed 4 = 4 pole determined by the
pump selected
50 3. Frequency 50 = 50 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
Selection using the
011 = 1.1 kW (IEC 90S) characteristic curves
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)

4-pole
50 Hz
Standard TP
Performance curves, centrifugal pump, TP 1020 (4-polig / 50 Hz)

H 0 5 10 15 20 25 30 35 40
USGPM
[ft] [m]
0 5 10 15 20 25 30 35
IGPM
20 6 Ø130 η 0.25 η 0.30 η 0.35
η 0.40
η 0.45

Ø120 η 0.50
5

15
Impeller diameter

Ø110
4

10 3
Ø90

Impeller selection in
accordance with capacity 2 Ø80
and pump head
5
Standard TPS
1

0 0
50 Hz
0 1 2 3 4 5 6 7 8 9 10
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

1.5
4.0
Ø80 Ø130
3.0 1.0

2.0
0.5
1.0

0 0
0 1 2 3 4 5 6 7 8 9 10
P Q [m3/h]
[hp] [kW]
Required motor power

0.3
0.2
Ø130

0.2 Ø120
Ø110
Motor output selection in 0.1 Ø100
accordance with capacity 0.1
Ø90
and pump head Ø80

0 0
0 1 2 3 4 5 6 7 8 9 10
Q [m3/h]

37
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 10 m³/h
Pump head max. 6 m w.c.
Housing pressure max. 10 bar

Code T P 0 1 0 2 0 4 5 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01020 1. Type TP 1020
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)

TP 1020
Motor size b c** d f h m n p t* u v w x y*
80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.5
90S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5
100L (2.2 kW / 3 kW) 602 474/489 154 335 403 76 278 160 25.5 112 125 85 14 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

38
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 4-pole (n=1,450 min-1), 50 Hz

H 0 5 10 15 20 25 30 35 40
USGPM
[ft] [m]
0 5 10 15 20 25 30 35
IGPM
20 6 Ø130 η 0.25 η 0.30 η 0.35
η 0,40
η 0.45

Ø120 η 0.50
5

15
Ø110
4
Impeller diameter

10 3
Ø90

4-pole
50 Hz
Standard TP
2 Ø80

0 0
50 Hz
0 1 2 3 4 5 6 7 8 9 10
NPSH Q [m3/h]
[ft] [m]
1.5
Required NPSH-value

4.0
Ø80 Ø130
3.0 1.0

2.0 Standard TPS


0.5
1.0

0 0
0 1 2 3 4 5 6 7 8 9 10
P Q [m3/h]
[hp] [kW]
Required motor power

0.3
0.2
Ø130

0.2 Ø120
Ø110
0.1 Ø100
0.1
Ø90
Ø80

0 0
0 1 2 3 4 5 6 7 8 9 10
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

39
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 19 m³/h
Pump head max. 11 m w.c.
Housing pressure max. 16 bar

Code T P 0 1 5 4 0 4 5 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01540 1. Type TP 1540
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
130 4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)

TP 1540
Motor size b c** d f h m n p t* u v w x y*
80 490 396 121.5 285 352 90 228 125 25.5 92 140 82 42 25.5
90S / 90L 496 431 121.5 285 352 90 228 140 25.5 90 140 82 42 25.5
100L (2.2 kW / 3 kW) 608 480/495 131.5 335 403 90 278 160 25.5 112 140 85 42 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

40
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 4-pole (n=1,450 min-1), 50 Hz

H 0 10 20 30 40 50 60 70 80
USGPM
[ft] [m]
0 10 20 30 40 50 60 70
IGPM
Ø180 η 0.30 η 0.35 η 0.40 η 0.45
11 η 0.50
35 η 0.55
10
Ø170 η 0.57
30 9
Ø160
8
25
Impeller diameter

Ø150
7
Ø140
20 6
Ø130

4-pole
50 Hz
5
15

Standard TP
4

10 3

2
5

0
1

0
50 Hz
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
NPSH Q [m3/h]
[ft] [m]
20
Required NPSH-value

5
15
4
Ø130 Ø180
10 3
2
Standard TPS
5
1
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P Q [m3/h]
[hp] [kW]
1.6 1.2
1.1
1.4
Required motor power

1.0
1.2 0.9 Ø180
0.8
1.0
0.7
0.8 0.6 Ø170
0.5 Ø160
0.6
0.4 Ø150
0.4 0.3 Ø140
0.2 Ø130
0.2
0.1
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

41
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 4-pole (n=1,450 min-1), 50 Hz

Materials Pump housing, 316L (1.4404), deep-drawn


impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 19 m³/h
Pump head max. 9 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 3 0 4 5 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02030 1. Type TP 2030
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm
145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)

TP 2030
Motor size b c** d f h m n p t* u v w x y*
80 488 394 121.5 285 352 85 228 125 25.5 92 135 82 40 25.5
90S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5
100L (2.2 kW / 3 kW) 606 478/493 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5
112M 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5
132S 707 557 152 410 444 85 332 216 25.5 132 135 85 40 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

42
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 4-pole (n=1,450 min-1), 50 Hz

H 0 10 20 30 40 50 60 70 80
USGPM
[ft] [m]
0 10 20 30 40 50 60 70
11 IGPM
35
10
Ø160 η 0.30 η 0.35 η 0.40
η 0.45 η 0.50 η 0.55
30 9
Ø150 η 0.60
8
Impeller diameter

25
7 Ø140

20 6 Ø130

4-pole
50 Hz
5 Ø120
15

Standard TP
4 Ø110

10 3

2
5

0
1

0
50 Hz
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

4.0 3.5
3.0
3.0 Ø110 Ø160
2.5
2.0 2.0
1.0
Standard TPS
1.0
0.5
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P Q [m3/h]
[hp] [kW]
0.8 0.6
Ø160
Required motor power

0.7 0.5 Ø150


0.6
0.4 Ø140
0.5
Ø130
0.4 0.3 Ø120
Ø110
0.3
0.2
0.2
0.1
0.1

0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

43
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 19 m³/h
Pump head max. 15 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 5 0 4 5 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02050 1. Type TP 2050
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
160 4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm
190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)

TP 2050
Motor size b c** d f h m n p t* u v w x y*
80 504 410 126 285 352 107 228 125 25.5 90 161 82 52 25.5
90S / 90L 510 445 126 285 352 107 228 140 25.5 90 161 82 52 25.5
100L (2.2 kW / 3 kW) 622 494/509 136 335 403 107 278 160 25.5 112 161 85 52 25.5
112M 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

44
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 4-pole (n=1,450 min-1), 50 Hz

H 0 10 20 30 40 50 60 70 80
USGPM
[ft] [m]
0 10 20 30 40 50 60 70
20 IGPM

60 18
Ø210
16 η 0.40
η 0.45
50 η 0.50
Ø200 η 0.52
14 η 0.52
Ø190
Impeller diameter

η 0.50
40 12
Ø180 η 0.45
Ø170

4-pole
10

50 Hz
30 Ø160

Standard TP
8

η 0.40 η 0.45
20 6 η 0.45

4
10

0
2

0
50 Hz
0 2.5 5 7.5 10 12.5 15 17.5 20
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

5 1.5

1 Ø210
Ø160
2.5
0.5
Standard TPS

0 0
0 2.5 5 7.5 10 12.5 15 17.5 20
P Q [m3/h]
[hp] [kW]
2.0
2.5
Required motor power

2.0 1.5

Ø210
1.5
1.0
Ø200
1.0 Ø190
0.5 Ø180
0.5 Ø170
Ø160
0 0
0 2.5 5 7.5 10 12.5 15 17.5 20
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

45
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 20 m³/h
Pump head max. 21 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 5 7 5 4 5 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02575 1. Type TP 2575
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
200 4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm
225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm
245 = 245 mm 250 = 250 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 2575
Motor size b c** d f h m n p t* u v w x y*
100L / 112M 621 508/515 138 335 403 124.5 278 160/190 25.5 112 190 85 48.5 25.5
132S / 132M 720 570/630 156 410 444 124.5 332 216 25.5 132 190 85 48.5 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

46
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 4-pole (n=1,450 min-1), 50 Hz

H 0 10 20 30 40 50 60 70 80 90
USGPM
[ft] [m]
0 10 20 30 40 50 60 70 80
IGPM
22 Ø250 η 0.35
70 η 0.40
20 Ø240 η 0.44
η 0.46
60 18 Ø230 η 0.46
Ø220
16 η 0.44
50 Ø210
Impeller diameter

η 0.48
14
Ø200

4-pole
50 Hz
40 12

Standard TP
η 0.35
10 η 0.40
30
η 0.44
8

20 6

4
10

0
2

0
50 Hz
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

1.5
4 Ø200 Ø250
3 1
Standard TPS
2
0.5
1

0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
P Q [m3/h]
[hp] [kW]
Required motor power

2.1 Ø250
2.8
2.0
2.4 1.8
1.6 Ø240
2.0
1.4
Ø230
1.6 1.2
1.0 Ø220
1.2 Ø210
0.8
Ø200
0.8 0.6
0.4
0.4
0.2
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

47
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 36 m³/h
Pump head max. 16 m w.c.
Housing pressure max. 16 bar

Code T P 0 3 0 5 0 4 5 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP03050 1. Type TP 3050
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
140 4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
011 = 1.1 kW (IEC 90S)
015 = 1.5 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 3050
Motor size b c** d f h m n p t* u v w x y*
80 500 406 124 285 352 103 228 125 25.5 92 155 82 50 25.5
90S / 90L 506 441 124 285 352 103 228 140 25.5 90 155 82 50 25.5
100L (2.2 kW / 3 kW) 618 490/505 134 335 403 103 278 160 25.5 112 155 85 50 25.5
112M 618 512 134 335 403 103 278 190 25.5 112 155 85 50 25.5
132S / 132M 719 569/609 154 410 444 103 332 216 25.5 132 155 85 50 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

48
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 4-pole (n=1,450 min-1), 50 Hz

H 0 20 40 60 80 100 120 140 160


USGPM
[ft] [m]
0 20 40 60 80 100 120 140
20 IGPM

60 18
Ø210 η 0.40 η 0.45
η 0.55
η 0.55
16
50 Ø200 η 0.60
η 0.61
14 Ø190
η 0.60
Impeller diameter

40 12 Ø180
η 0.55
Ø170
η 0.50

4-pole
50 Hz
10
Ø160
30

Standard TP
Ø150
8
Ø140
20 6

4 η 0.45
10

50 Hz
η 0.40
2

0 0
0 5 10 15 20 25 30 35 40
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

10 3
Ø210
7.5 Ø140
2
5.0
1
Standard TPS
2.5

0 0
0 5 10 15 20 25 30 35 40
P Q [m3/h]
[hp] [kW]
2.0
2.5 Ø210
Required motor power

Ø200
2.0 1.5
Ø190

Ø180
1.5
1.0 Ø170
Ø160
1.0
Ø150
0.5 Ø140
0.5

0 0
0 5 10 15 20 25 30 35 40
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

49
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 40 m³/h
Pump head max. 17 m w.c.
Housing pressure max. 16 bar

Code T P 0 5 0 6 0 4 5 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP05060 1. Type TP 5060
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
155 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
215 = 215 mm 220 = 220 mm 225 = 225 mm
022 5. Motor power 022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 5060
Motor size b c** d f h m n p t* u v w x y*
100L (2.2 kW / 3 kW) 622 494/509 137 335 403 114.5 278 160 27.5 112 230 85 51 25.5
112M 622 516 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5
132S / 132M 723 573/613 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

50
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 4-pole (n=1,450 min-1), 50 Hz

H 0 20 40 60 80 100 120 140 160 180


USGPM
[ft] [m]
0 20 40 60 80 100 120 140
20 IGPM
Ø225 η 0.40 η 0.45 η 0.50 η 0.55
η 0.58
60 Ø215
η 0.58
Ø205
η 0.62 η 0.55
15
Ø195 η 0.50
45 Ø185 η 0.45
Impeller diameter

Ø175
η 0.40
Ø165
10

4-pole
50 Hz
30

Standard TP
Ø155

5
15

0
50 Hz
0
0 5 10 15 20 25 30 35 40
NPSH Q [m3/h]
Required NPSH-value

[ft] [m]
7.0 2.0
6.0 Ø225
5.0 1.5
4.0 Ø155
3.0 1.0
Standard TPS
2.0 0.5
1.0
0 0
0 5 10 15 20 25 30 35 40
P Q [m3/h]
[hp] [kW]
3.0
Required motor power

4.0 Ø225
3.5 2.5
Ø215
3.0
2.0 Ø205
2.5
Ø195
2.0 1.5
Ø185
1.5 1.0 Ø175
1.0 Ø165
Ø155
0.5
0.5
0 0
0 5 10 15 20 25 30 35 40
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

51
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 55 m³/h
Pump head max. 19 m w.c.
Housing pressure max. 16 bar

Code T P 0 7 0 6 0 4 5 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP07060 1. Type TP 7060
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
155 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm
220 = 220 mm 225 = 225 mm
022 5. Motor power 022 = 2.2 kW (IEC 100L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 7060
Motor size b c** d f h m n p t* u v w x y*
100L (2.2 kW / 3 kW) 622 494/509 132 335 427 110 278 160 27.5 112 230 85 56 25.5
112M 622 516 132 335 427 110 278 190 27.5 112 230 85 56 25.5
132S / 132M 723 573/613 152 410 444 110 332 216 27.5 132 230 85 56 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

52
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 4-pole (n=1,450 min-1), 50 Hz

H 0 25 50 75 100 125 150 175 200 225 250 275


USGPM
[ft] [m]
0 25 50 75 100 125 150 175 200 225
20 IGPM
Ø225 η 0.50 η 0.55 η 0.60
60
Ø215
η 0.65
Ø205
50 15 η 0.60
Ø195 η 0.66
η 0.55
Ø185
Impeller diameter

40 η 0.50
Ø175
10 Ø165
30 Ø155

20
5

10
50 Hz

4-pole
50 Hz
0 0

Standard TP
0 5 10 15 20 25 30 35 40 45 50 55 60 65
NPSH Q [m3/h]
[ft] [m]

10.0 3.0
Required NPSH-value

Ø225
8.0 2.5 Ø155
6.0 2.0

1.5
4.0
1.0
2.0
0.5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65
P Q [m3/h]
[hp] [kW] Standard TPS
5.0
3.5 Ø225
4.5

4.0 3.0 Ø215


Required motor power

3.5 2.5 Ø205


3.0
2.0 Ø195
2.5
Ø185
2.0 1.5
Ø175
1.5 Ø165
1.0
1.0 Ø155
0.5
0.5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65

The flow charts are based on a pumping medium of: Q [m3/h]


densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

53
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 65 m³/h
Pump head max. 23 m w.c.
Housing pressure max. 16 bar

Code T P 0 8 0 8 0 4 5 0 D N N F K 1 0 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP08080 1. Type TP 8080
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
180 4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm
230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm
250 = 250 mm
040 5. Motor power 040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 8080
Motor size b c** d f h m n p t* u v w x y*
112M 641 535 136 335 403 124 278 190 27.5 112 250 85 71 25.5
132S / 132M 742 592/632 156 410 444 124 332 216 27.5 132 250 85 71 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

54
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 4-pole (n=1,450 min-1), 50 Hz

H 0 25 50 75 100 125 150 175 200 225 250 275 300 325
USGPM
[ft] [m]
0 25 50 75 100 125 150 175 200 225 250
25 IGPM
η 0.40
80 η 0.45 η 0.50 η 0.55
Ø250 η 0.60
Ø240
70 η 0.60
Impeller diameter

20 Ø230 η 0.64
Ø220 η 0.55
60
η 0.66 η 0.50
Ø210

15 Ø200
50
Ø190

40 Ø180

4-pole
50 Hz
Standard TP
10
30

20
5

50 Hz
10

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

6.0 2.0 Ø250


1.5 Ø180
4.0
1.0 Standard TPS
2.0
0.5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
P Q [m3/h]
[hp] [kW]

7.0 Ø250
5.0
Ø240
Required motor power

6.0
Ø230
4.0
5.0 Ø220
4.0 3.0 Ø210
Ø200
3.0
2.0 Ø190
2.0 Ø180
1.0
1.0

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

55
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 4-pole (n=1,450 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 100 m³/h
Pump head max. 12 m w.c.
Housing pressure max. 16 bar

Code T P 1 6 0 4 0 2 5 0 D N N F K 1 5 0 1 0 0 E K E - 1 - J J -
Position 1 4 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP16040 1. Type TP 16040
4 2. Speed 4 = 4 pole
50 3. Frequency 50 = 50 Hz
160 4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm
180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm
200 = 200 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 16040
Motor size b c** d f h m n p t* u v w x y*
100L / 112M 651 538/545 131 335 403 108 278 160/190 29.5 112 280 85 86 27.5
132S / 132M 752 602/642 151 410 444 108 332 216 29.5 132 280 85 86 27.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

56
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 4-pole (n=1,450 min-1), 50 Hz

H 0 50 100 150 200 250 300 350 400 450


USGPM
[ft] [m]
0 50 100 150 200 250 300 350
IGPM
Ø200 η 0.50 η 0.55 η 0.60
40 12 η 0.65
Ø190 η 0.67
11
35
η 0.65
10
Ø180
30 9 η 0.60
Impeller diameter

8 Ø170
25 η 0.55
7
Ø160
20 6
η 0.40 η 0.50
5 η 0.45
15
4

4-pole
50 Hz
10

Standard TP
3

2
5

0
1

0
50 Hz
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105
NPSH Q [m3/h]
[ft] [m]
4.0
Required NPSH-value

Ø200
12 3.5
10 3.0

8.0 2.5
2.0
6.0
1.5
4.0 Ø160
1.0
2.0 0.5 Standard TPS
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105
P Q [m3/h]
[hp] [kW]
4.5
5.5 Ø200
5.0 3.5
Required motor power

4.5 3.0 Ø190


4.0
2.5
3.0 Ø180
2.0 Ø170
2.5
2.0 1.5 Ø160

1.5
1.0
1.0
0.5
0.5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

57
GEA Tuchenhagen
Standard version, centrifugal pump, type TP, 2-pole (n=3,500 min-1), 60 Hz

Standard version 2 pole/60Hz


Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Depending on pump size
Mechanical seal Single-acting, material: C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Standard equipment Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 240 m3/h
Pump head max. 130 m w.c.

TP 1020 TP 1540 bis TP8080 TP 16040

30 40 50 100 200 300 400 500 800 1200


USGPM
20 30 40 50 100 200 300 400 500 700 1000
IGPM
150

100 TP 2575-2
TP 5060-2 TP
TP 80
70 80
TP2050-2 60 -2
-2

TP 1540-2
50
TP 3050-2
Performance characteristics TP

TP 2030-2
40
TP 16040-2

30

H
[m] 20

TP 1020-2

10

n = 3,500 min-1
1
1 10 20 30 40 50 70 100 200 300

Q [m3/h]
58
GEA Tuchenhagen
Example of a standard selection

Code T P 0 1 0 2 0 2 6 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Standard version, for other versions see options

Example Pos Designation Code of selection characteristics


TP01020 1. Type TP01020 Selected values
2 2. Speed 2 = 2 pole determined by the
pump selected
60 3. Frequency 60 = 60 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
012 5. Motor power 012 = 1.25 kW (IEC 80)
015 = 1.5 kW (IEC 90S) Selection using the
022 = 2.2 kW (IEC 90L) characteristic curves
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)

Standard TP
Performance curves, centrifugal pump,TP 1020 (2-polig / 60 Hz)

H 0 20 40 60 80 100
USGPM
[ft] [m]

2-pole
0 20 40 60 80

60 Hz
IGPM
120 36
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40

32 η 0.45

100 Ø120 η 0.50


Impeller diameter

28

Ø110
80 24

20 Ø100

60
Impeller selection in 16 Ø90
accordance with capacity
and pump head 40 12 Ø80

8
Standard TPS
20
4
60 Hz
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
Erforderlich NPSH

NPSH Q [m3/h]
[ft] [m]
12.5 4
Ø80 Ø130
10 3
7.5
2
5
1
2.5

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
P Q [m3/h]
[hp] [kW]
Required motor power

2.8
3.6 Ø130
3.2 2.4
Ø120
2.8
2.0
2.4 Ø110
Motor output selection in 1.6
2.0
accordance with capacity 1.6 1.2 Ø100
and pump head 1.2 Ø90
0.8 Ø80
0.8
0.4
0.4 0 2 4 6 8 10 12 14 16 18 20 22 24 26
Q [m3/h]

59
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 24 m³/h
Pump head max. 34 m w.c.
Housing pressure max. 10 bar

Code T P 0 1 0 2 0 2 6 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01020 1. Type TP 1020
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
012 5. Motor power 012 = 1.25 kW (IEC 80)
015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)

TP 1020
Motor size b c** d f h m n p t* u v w x y*
80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.5
90S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5
100L / 112M 602 474/496 154 335 403 76 278 160 25.5 112 125 85 14 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

60
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 2-pole (n=3,500 min-1), 60 Hz

H 0 20 40 60 80 100
USGPM
[ft] [m]
0 20 40 60 80
IGPM
120 36
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40

32 η 0.45

100 Ø120 η 0.50

28
Impeller diameter

Ø110
80 24

20 Ø100

60
16 Ø90

Standard TP
40 12 Ø80

2-pole
60 Hz
20
4
60 Hz
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

12.5 4
Ø80 Ø130
10 3
7.5
2
5 Standard TPS
1
2.5

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
P Q [m3/h]
[hp] [kW]
2.8
3.6 Ø130
Required motor power

3.2 2.4
Ø120
2.8
2.0
2.4 Ø110
1.6
2.0
1.6 1.2 Ø100

1.2 Ø90
0.8 Ø80
0.8
0.4
0.4 0 2 4 6 8 10 12 14 16 18 20 22 24 26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

61
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 44 m³/h
Pump head max. 62 m w.c.
Housing pressure max. 16 bar

Code T P 0 1 5 4 0 2 6 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01540 1. Type TP 1540
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
130 4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)

TP 1540
Motor size b c** d f h m n p t* u v w x y*
100L 608 480 131.5 335 403 90 278 160 25.5 112 140 85 42 25.5
112M (4 kW + 5.5 kW) 608 502 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5
112M (7.5 kW) 608 524 131.5 335 403 90 278 190 25.5 112 140 85 42 25.5
132M (11 kW) 709 619 152 410 444 90 332 216 25.5 132 140 85 42 25.5
132M (15 kW) 709 670 152 410 444 90 332 216 25.5 132 140 85 42 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

62
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 2-pole (n=3,500 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225


USGPM
[ft] [m]
0 25 50 75 100 125 150 175
70 IGPM
η 0.30 η 0.35 η 0.40 η 0.45
Ø180 η 0.55
η 0.50
200 60
Ø170 η 0.57

50 Ø160
Impeller diameter

150 Ø150
40
Ø140

100 30 Ø130

Standard TP
20

50

60 Hz

2-pole
60 Hz
10

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

4
Ø130 Ø180
10 3

2
5
1 Standard TPS
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
P Q [m3/h]
[hp] [kW]
12

14 Ø180
Required motor power

10
Ø170
12
8 Ø160
10
Ø150
8 6
Ø140
6 Ø130
4
4
2
2
1 1
0 4 8 12 16 20 24 28 32 36 40 44 48 52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

63
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 44 m³/h
Pump head max. 52 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 3 0 2 6 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02030 1. Type TP 2030
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm
145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm
015 5. Motor power 015 = 1.5 kW (IEC 90S)
022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)

TP 2030
Motor size b c** d f h m n p t* u v w x y*
90S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5
100L 606 478 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5
112M (4 kW + 5.5 kW) 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5
112M (7.5 kW) 606 522 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5
132M 707 617 152 410 444 85 332 216 25.5 132 135 85 40 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

64
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 2-pole (n=3,500 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225


USGPM
[ft] [m]
0 25 50 75 100 125 150 175
56 IGPM
η 0.30 η 0.35 η 0.40 η 0.45
175 Ø160
η 0.50
48 Ø150 η 0.60
150

40 Ø140
Impeller diameter

125
Ø130
32
100
Ø120

24

Standard TP
75 Ø110

16
50

2-pole
60 Hz
25 8
60 Hz
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

4
Ø110 Ø160
10 3

2
5 Standard TPS
1

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
P Q [m3/h]
[hp] [kW]
10
12
Required motor power

8 Ø160
10
Ø150
8 6 Ø140
Ø130
6
4
Ø120
4 Ø110
2
2

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

65
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 42 m³/h
Pump head max. 85 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 5 0 2 6 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02050 1. Type TP 2050
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
160 4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm
190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)

TP 2050
Motor size b c** d f h m n p t* u v w x y*
100L 622 494 136 335 403 107 278 160 25.5 112 161 85 52 25.5
112M (4 kW + 5.5 kW) 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5
112M (7.5 kW) 622 538 136 335 403 107 278 190 25.5 112 161 85 52 25.5
132M (11 kW) 723 633 156 410 444 107 332 216 25.5 132 161 85 52 25.5
132M (15 kW) 723 684 156 410 444 107 332 216 25.5 132 161 85 52 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

66
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 2-pole (n=3,500 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200


USGPM
[ft] [m]
0 25 50 75 100 125 150
110 IGPM
350
100

300 Ø210
90 η 0.40 η 0.45 η 0.50
η 0.52
Ø200
80 η 0.52
250 η 0.50
Ø190
Impeller diameter

70
Ø180 η 0.45
200 60
Ø170

50 Ø160
150
40

Standard TP
η 0.40
η 0.45
100 30

20
50

2-pole
60 Hz
0
10

0
60 Hz
0 5 10 15 20 25 30 35 40 45
NPSH Q [m3/h]
Required NPSH-value

[ft] [m]
10 3 Ø160
Ø210
7.5
2
5
1
2.5

0 0
Standard TPS
0 5 10 15 20 25 30 35 40 45
P Q [m3/h]
[hp] [kW]
Ø210
20 15
Ø200
Required motor power

15 Ø190
10
Ø180

10 Ø170

Ø160
5
5

0 0
0 5 10 15 20 25 30 35 40 45
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

67
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 48 m³/h
Pump head max. 130 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 5 7 5 2 6 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02575 1. Type TP 2575
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
20 4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm
225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm
245 = 245 mm 250 = 250 mm
055 5. Motor power 055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)

TP 2575
Motor size b c** d f h m n p t* u v w x y*
112M (5.5 kW / 7.5 kW) 621 515/537 138 335 403 124.5 278 190 25.5 112 190 85 48.5 25.5
132M (11 kW) 720 630 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5
132M (15 kW) 720 681 156 410 444 107 332 216 25.5 132 190 85 48.5 25.5
160L 894 782 191 640 598 124.5 412 254 25.5 160 190 110 48.5 25.5
200L 1,033 908 200.5 810 668 124.5 472 318 25.5 200 190 115 48.5 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

68
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 2-pole (n=3,500 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225


USGPM
[ft] [m]
0 25 50 75 100 125 150 175
140 IGPM
450
130 Ø250
η 0.35
400 120 η 0.40
Ø240 η 0.44
110 η 0.46
350 Ø230 η 0.46
100
Ø220
300 η 0.44
90
Impeller diameter

Ø210 η 0.4
8
80 Ø200
250
70

200 60 η 0.35
η 0.40
50
150 η 0.44

Standard TP
40

100 30

50
20
60 Hz

2-pole
60 Hz
10

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

15
4.0 Ø250
Ø200
10 3.0

2.0
5
1.0
Standard TPS
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56
P Q [m3/h]
[hp] [kW]
40 30
Ø250
35
25
Required motor power

30 Ø240
20
25 Ø230

20 15 Ø220
Ø210
15
10 Ø200
10
5
5

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

69
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 85 m³/h
Pump head max. 95 m w.c.
Housing pressure max. 16 bar

Code T P 0 3 0 5 0 2 6 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP03050 1. Type TP 3050
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
140 4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)

TP 3050
Motor size b c** d f h m n p t* u v w x y*
100L 618 504 134 335 403 103 278 160 25.5 112 155 85 50 25.5
112M (4 kW + 5.5 kW) 618 515 134 335 403 103 278 190 25.5 112 155 85 50 25.5
112M (7.5 kW) 618 534 134 335 403 103 278 190 25.5 112 155 85 50 25.5
132M (11 kW) 719 629 154 410 444 103 332 216 25.5 132 155 85 50 25.5
132M (15 kW) 719 680 154 410 444 103 332 216 25.5 132 155 85 50 25.5
160L 893 781 189 640 598 103 412 254 25.5 160 155 110 50 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

70
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 2-pole (n=3,500 min-1), 60 Hz

H 0 50 100 150 200 250 300 350 400


USGPM
[ft] [m]
0 50 100 150 200 250 300
110 IGPM
350
100 Ø210 η 0.40 η 0.45 η 0.50 η 0.55
300 90 η 0.60
Ø200
η 0.61
80 Ø190
250 η 0.60
Ø180
Impeller diameter

70
η 0.55
Ø170
200 60 η 0.50
Ø160
50 Ø150
150

Standard TP
40 Ø140

100 30

20 η 0.45

2-pole
60 Hz
50 η 0.40

0
10

0
60 Hz
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
NPSH Q [m3/h]
Required NPSH-value

[ft] [m]
20 6 Ø140 Ø210
5
15
4
10 3
2
5
1
Standard TPS
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
P Q [m3/h]
[hp] [kW]
30
Ø210
35
25 Ø200
Required motor power

30 Ø190
20
25
Ø180
20 15 Ø170
Ø160
15
10 Ø150
10 Ø140
5
5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

71
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 80 m³/h
Pump head max. 110 m w.c.
Housing pressure max. 16 bar

Code T P 0 5 0 6 0 2 6 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP05060 1. Type TP 5060
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
155 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
215 = 215 mm 220 = 220 mm 225 = 225 mm
055 5. Motor power 055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)

TP 5060
Motor size b c** d f h m n p t* u v w x y*
112M (5.5 kW / 7.5 kW) 622 517/538 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5
132M (11 kW) 723 633 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5
132M (15 kW) 723 684 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5
160L 897 785 192 640 598 114.5 412 254 27.5 160 230 110 52 25.5
200L 1,030 905 195 810 673 114.5 472 318 27.5 200 230 115 52 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

72
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 2-pole (n=3,500 min-1), 60 Hz

H 0 50 100 150 200 250 300 350 400


USGPM
[ft] [m]
0 50 100 150 200 250 300 350
120 IGPM

Ø225 η 0.40 η 0.45 η 0.50 η 0.58


110 η 0.55
350
Ø215
100

300 Ø205 η 0.58


90 η 0.62
η 0.55
Ø195
80 η 0.50
Impeller diameter

250 Ø185
70 η 0.45
Ø175
200 η 0.40
60 Ø165

Ø155
50
150

Standard TP
40

100 30

20

2-pole
60 Hz
50

0
10

0
60 Hz
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
NPSH Q [m3/h]
Required NPSH-value

[ft] [m]
20 6
5 Ø225
15 Ø155
4
10 3
2
5
1
0 0
Standard TPS
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
P Q [m3/h]
[hp] [kW]
40
50
35 Ø225
45
Ø215
Required motor power

40 30
Ø205
35
25
Ø195
30
20 Ø185
25
Ø175
20 15
Ø165
15 Ø155
10
10
5
5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

73
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 120 m³/h
Pump head max. 105 m w.c.
Housing pressure max. 16 bar

Code T P 0 7 0 6 0 2 6 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP07060 1. Type TP 7060
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
155 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm
220 = 220 mm 225 = 225 mm
110 5. Motor power 075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)

TP 7060
Motor size b c** d f h m n p t* u v w x y*
112M 622 538 132 335 427 110 278 190 27.5 112 230 85 56 25.5
132M (11 kW) 723 633 152 410 444 110 332 216 27.5 132 230 85 56 25.5
132M (15 kW) 723 684 152 410 444 110 332 216 27.5 132 230 85 56 25.5
160L 897 785 187 640 596 110 412 254 27.5 160 230 110 56 25.5
200L 1,030 905 190.5 810 668 110 472 318 27.5 200 230 115 56 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

74
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 2-pole (n=3,500 min-1), 60 Hz

H 0 100 200 300 400 500 600


USGPM
[ft] [m]
0 100 200 300 400 500
120 IGPM

Ø225
110 η 0.50 η 0.55
η 0.60
350
Ø215
100
η 0.65
300 90 Ø205
η 0.66 η 0.60
Ø195
80
250 η 0.55
Impeller diameter

Ø185
70
Ø175 η 0.50

200 60
Ø165
50 Ø155
150
40

100 30

20

60 Hz

Standard TP
50
10

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Q [m3/h]

2-pole
NPSH

60 Hz
[ft] [m]
8
30 Ø155
7 Ø225
Required NPSH-value

25
6
20
5
15
4

10 3
2
5
1

0 0
Standard TPS
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
P Q [m3/h]
[hp] [kW]
60

70
Ø225
50
Required motor power

60
40 Ø215
50
Ø205
40 30
Ø195
30 Ø185
20 Ø175
20 Ø165
Ø155
10
10

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

75
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 125 m³/h
Pump head max. 130 m w.c.
Housing pressure max. 16 bar

Code T P 0 8 0 8 0 2 6 0 D N N F K 1 0 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP08080 1. Type TP 8080
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
180 4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm
230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm
250 = 250 mm
150 5. Motor power 110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
370 = 37.0 kW (IEC 200L)
450 = 45.0 kW (IEC 225M)

TP 8080
Motor size b c** d f h m n p t* u v w x y*
132M 742 652/703 156 410 444 124 332 216 27.5 132 250 85 71 25.5
160L 916 804 191 640 598 124 412 254 27.5 160 250 110 71 25.5
200L 1,050 925 195 810 668 124 472 318 27.5 200 250 115 71 25.5
225M 1,076 961 195 810 720 124 472 356 27.5 200 250 115 71 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

76
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 2-pole (n=3,500 min-1), 60 Hz

H 0 100 200 300 400 500 600


USGPM
[ft] [m]
0 100 200 300 400 500
IGPM
140 η 0.40 η 0.45 η 0.50
450 Ø250 η 0.55
η 0.60
130 Ø240
400 η 0.60
120 Ø230
η 0.64
110 Ø220
350 η 0.55
100 Ø210
300 η 0.66
Impeller diameter

90 Ø200

80 Ø190
250
Ø180
70

Standard TP
200 60

50
150
40
η 0.50

2-pole
60 Hz
100 30

20

60 Hz
50
10

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

10
30
8 Ø180 Ø250
20 6
Standard TPS
4
10
2

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
P Q [m3/h]
[hp] [kW]
70 Ø250 Ø240 Ø230 Ø220
50
Required motor power

60 Ø210
40 Ø200
50
Ø190
40 30
Ø180
30
20
20
10
10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

77
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 240 m³/h
Pump head max. 70 m w.c.
Housing pressure max. 16 bar

Code T P 1 6 0 4 0 2 6 0 D N N F K 1 5 0 1 0 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP16040 1. Type TP 16040
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
180 4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm
180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm
200 = 200 mm
150 5. Motor power 110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)
300 = 30.0 kW (IEC 200L)
370 = 37.0 kW (IEC 200L)
450 = 45.0 kW (IEC 225M)

TP 16040
Motor size b c** d f h m n p t* u v w x y*
132M 752 713 151 410 444 108 332 216 29.5 132 280 85 86 27.5
160L 926 814 186 640 596 108 412 254 29.5 160 280 110 86 27.5
200L 1,059 934 189 810 668 108 472 318 29.5 200 280 115 86 27.5
225M 1,085 970 189 810 720 108 521 356 29.5 225 280 115 86 27.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

78
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 2-pole (n=3,500 min-1), 60 Hz

H 0 150 300 450 600 750 900 1050 1200


USGPM
[ft] [m]
0 100 200 300 400 500 600 700 800 900 1000
80 IGPM
η 0.50
250 Ø200 η 0.55
η 0.60
70 η 0.65
η 0.67
Ø190
200 60 η 0.65

Ø180
η 0.60
Impeller diameter

50
Ø170
150 η 0.55
40 Ø160

Standard TP
η 0.50
100 30 η 0.40
η 0.45

20

2-pole
60 Hz
50
10
60 Hz
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

50 16

40 12 Ø200
30
8
20 Standard TPS
4 Ø160
10

0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260
P Q [m3/h]
[hp] [kW]
80 60
Required motor power

70 Ø200
50
60
40 Ø190
50
Ø180
40 30
Ø170
30
20 Ø160
20
10
10
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

79
GEA Tuchenhagen
Standard version, centrifugal pump, type TP, 4-pole (n=1,750 min-1), 60 Hz

Standard version 4 pole/60Hz


Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Depending on pump size
Mechanical seal Single-acting, material: C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Standard equipment Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 120 m3/h
Pump head max. 34 m w.c.

TP 1020 TP 1540 bis TP8080 TP 16040

30 40 50 100 200 300 400 500 600


USGPM
20 30 40 50 100 200 300 500
40 IGPM

30
25 TP 2575-4 TP 8080-4
TP 5
060-
4
Performance characteristics TP

20 TP 2050-4

TP 1540-4 TP 7060
TP 3050-4
10
TP 16040-4
H
[m]
5

TP 1020-4 TP 2030-4
3

n = 1,750 min-1
1
1 10 20 30 40 50 100 140
Q [m3/h]
80
GEA Tuchenhagen
Example of a standard selection

Code T P 0 1 0 2 0 4 6 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Standard version, for other versions see options

Example Pos Designation Code of selection characteristics


TP01020 1. Type TP01020 Selected values
4 2. Speed 4 = 4 pole determined by the
pump selected
60 3. Frequency 60 = 60 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
009 5. Motor power 007 = 0.75 kW (IEC 80) Selection using the
012 = 1.25 kW (IEC 90S) characteristic curves
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)

Standard TP
Performance curves, centrifugal pump, TP 1020 (4-polig / 60 Hz)

H 0 10 20 30 40 50
USGPM
[ft] [m]
0 10 20 30 40
IGPM
30 9
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40

8 η 0.45

25 Ø120 η 0.50

7
Impeller diameter

Ø110
20 6

4-pole
60 Hz
5 Ø100

15
4 Ø90

Impeller selection in
accordance with capacity 10 3 Ø80
and pump head
2
5
Standard TPS
1
60 Hz
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
NPSH
Required NPSH-value

Q [m3/h]
[ft] [m]
6.0 2.0
5.0 1.5 Ø80 Ø130
4.0
3.0 1.0
2.0
0.5
1.0
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
P Q [m3/h]
[hp] [kW]
Required motor power

0.3 Ø130
0.4
Ø120

0.3
0.2 Ø110

Ø100
Motor output selection in 0.2
Ø90
accordance with capacity
0.1 Ø80
and pump head 0.1

0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Q [m3/h]

81
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1020, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max 11 m³/h
Pump head max. 8 m w.c.
Housing pressure max. 10 bar

Code T P 0 1 0 2 0 4 6 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01020 1. Type TP 1020
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
080 4. Impeller 080 = 80 mm 100 = 100 mm 120 = 120 mm
090 = 90 mm 110 = 110 mm 130 = 130 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
012 = 1.25 kW (IEC 90S)
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)

TP 1020
Motor size b c** d f h m n p t* u v w x y*
80 484 390 144 285 352 76 228 125 25.5 92 125 82 14 25.5
90S / 90L 490 425 144 285 352 76 228 140 25.5 90 125 82 14 25.5
100L 602 474 154 335 403 76 278 160 25.5 112 125 85 14 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

82
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1020, 4-pole (n=1,750 min-1), 60 Hz

H 0 10 20 30 40 50
USGPM
[ft] [m]
0 10 20 30 40
IGPM
30 9
Ø 1 3 0 η 0.25 η 0.30
η 0.35 η 0.40

8 η 0.45

25 Ø120 η 0.50

Ø110
20 6
Impeller diameter

5 Ø100

15
4 Ø90

Standard TP
10 3 Ø80

2
5
1
60 Hz
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
NPSH Q [m3/h]
Required NPSH-value

[ft] [m]

4-pole
60 Hz
6.0 2.0
5.0 1.5 Ø80 Ø130
4.0
3.0 1.0
2.0
0.5
1.0 Standard TPS
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
P Q [m3/h]
[hp] [kW]

0.3 Ø130
0.4
Required motor power

Ø120

0.3
0.2 Ø110

Ø100
0.2
Ø90
0.1 Ø80
0.1

0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

83
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 1540, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 22 m³/h
Pump head max. 15,5 m w.c.
Housing pressure max. 16 bar

Code T P 0 1 5 4 0 4 6 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP01540 1. Type TP 1540
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
130 4. Impeller 130 = 130 mm 140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
012 = 1.25 kW (IEC 90S)
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)

TP 1540
Motor size b c** d f h m n p t* u v w x y*
80 490 396 121.5 285 352 90 228 125 25.5 92 140 82 42 25.5
90S / 90L 496 431 121.5 285 352 90 228 140 25.5 90 140 82 42 25.5
100L 608 480 131.5 335 403 90 278 160 25.5 112 140 85 42 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

84
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 1540, 4-pole (n=1,750 min-1), 60 Hz

H 0 20 40 60 80 100
USGPM
[ft] [m]
0 20 40 60 80
IGPM
Ø180 η 0.30 η 0.35 η 0.40
16 η 0.45 η 0.50
η 0.55
50
14 η 0.57
Ø170

Ø160
40 12
Ø150
Impeller diameter

10
Ø140
30
8
Ø130

Standard TP
20 6

4
10
2
60 Hz
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26

4-pole
NPSH Q [m3/h]

60 Hz
[ft] [m]
Required NPSH-value

12.5 4
Ø130 Ø180
10 3
7.5
2
5 Standard TPS
1
2.5

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
P Q [m3/h]
[hp] [kW]
1.4
Required motor power

1.8 Ø180
1.6 1.2
Ø170
1.4 1.0 Ø160
1.2 Ø150
0.8
1.0
Ø140
0.8 0.6
Ø130
0.6 0.4
0.4
0.2
0.2
0 2 4 6 8 10 12 14 16 18 20 22 24 26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

85
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2030, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 50; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 23 m³/h
Pump head max. 13 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 3 0 4 6 0 D N N F K 0 5 0 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02030 1. Type TP 2030
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm
145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
012 = 1.25 kW (IEC 90S)
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)

TP 2030
Motor size b c** d f h m n p t* u v w x y*
80 488 394 121.5 285 352 85 228 125 25.5 92 135 82 40 25.5
90S / 90L 494 429 121.5 285 352 85 228 140 25.5 90 135 82 40 25.5
100L 606 478 131.5 335 403 85 278 160 25.5 112 135 85 40 25.5
112M 606 500 131.5 335 403 85 278 190 25.5 112 135 85 40 25.5
132S 707 557 152 410 444 85 332 216 25.5 132 135 85 40 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

86
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2030, 4-pole (n=1,750 min-1), 60 Hz

H 0 20 40 60 80 100
USGPM
[ft] [m]
0 20 40 60 80
IGPM
16

50 η 0.35
14 Ø160 η 0.30 η 0.40 η 0.45
η 0.50 η 0.55

Ø150 η 0.60
40 12
Impeller diameter

Ø140
10
30 Ø130
8
Ø120

Standard TP
20 6 Ø110

4
10
2
60 Hz
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
NPSH Q [m3/h]

4-pole
60 Hz
[ft] [m]
Required NPSH-value

12.5 4
10 3
7.5 Ø110 Ø160
2
5 Standard TPS
1
2.5

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
P Q [m3/h]
[hp] [kW]
1.4
1.8
Required motor power

1.6 1.2
1.4
1.0 Ø160
1.2
0.8 Ø150
1.0
Ø140
0.8 0.6 Ø130
0.6 Ø120
0.4 Ø110
0.4
0.2
0.2 0 2 4 6 8 10 12 14 16 18 20 22 24 26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

87
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2050, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 21 m³/h
Pump head max. 22 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 0 5 0 4 6 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02050 1. Type TP 2050
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
160 4. Impeller 160 = 160 mm 170 = 170 mm 180 = 180 mm 185 = 185 mm
190 = 190 mm 195 = 195 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
012 = 1.25 kW (IEC 90S)
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)

TP 2050
Motor size b c** d f h m n p t* u v w x y*
80 504 410 126 285 352 107 228 125 25.5 90 161 82 52 25.5
90S / 90L 510 445 126 285 352 107 228 140 25.5 90 161 82 52 25.5
100L 622 494 136 335 403 107 278 160 25.5 112 161 85 52 25.5
112M 622 516 136 335 403 107 278 190 25.5 112 161 85 52 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

88
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2050, 4-pole (n=1,750 min-1), 60 Hz

H 0 12.5 25 37.5 50 62.5 75 87.5 100


USGPM
[ft] [m]
0 12.5 25 37.5 50 62.5 75 87.5
28 IGPM
100

80 24
Ø210 η 0.40
η 0.45 η 0.50
70 η 0.52
Ø200
20 η 0.52
η 0.50
60 Ø190
Impeller diameter

η 0.45
16 Ø180
50
Ø170

Standard TP
Ø160
40 12

η 0.40
30 η 0.45
8

20

4
10
60 Hz

4-pole
60 Hz
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

5
Ø160 Ø210
Standard TPS
1
2.5

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
P Q [m3/h]
[hp] [kW]
Required motor power

2
2.5 Ø210
Ø200
2 1.5
Ø190
1.5 Ø180
1
Ø170
1
Ø160
0.5
0.5

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

89
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 2575, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 22 m³/h
Pump head max. 31 m w.c.
Housing pressure max. 16 bar

Code T P 0 2 5 7 5 4 6 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP02575 1. Type TP 2575
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
200 4. Impeller 200 = 200 mm 210 = 210 mm 215 = 215 mm 220 = 220 mm
225 = 225 mm 230 = 230 mm 235 = 235 mm 240 = 240 mm
245 = 245 mm 250 = 250 mm
040 5. Motor power 040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 2575
Motor size b c** d f h m n p t* u v w x y*
112M 621 515 138 335 403 124.5 278 190 25.5 112 190 85 48.5 25.5
132S / 132M 720 570/630 156 410 444 124.5 332 216 25.5 132 190 85 48.5 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

90
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 2575, 4-pole (n=1,750 min-1), 60 Hz

H 0 20 40 60 80 100
USGPM
[ft] [m]
0 20 40 60 80
IGPM
32 Ø250 η 0.35
η 0.40
100 η 0.44
Ø240
28
η 0.46
Ø230 η 0.46

80 24 Ø220
η 0.44
Ø210
Impeller diameter

20 Ø200 η 0.48

60
16

Standard TP
η 0.35 η 0.40
η 0.44
40 12

8
20
4
60 Hz
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26

4-pole
60 Hz
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

2
6
Ø250
1.5
4 Ø200
1
Standard TPS
2 0.5

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26
P Q [m3/h]
[hp] [kW]
5.0
3.5 Ø250
Required motor power

4.5
4.0 3.0
Ø240
3.5 2.5
Ø230
3.0
2.0 Ø220
2.5
Ø210
2.0 1.5
Ø200
1.5 1.0
1.0
0.5
0.5
0 2 4 6 8 10 12 14 16 18 20 22 24 26
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

91
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 3050, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 42 m³/h
Pump head max. 24 m w.c.
Housing pressure max. 16 bar

Code T P 0 3 0 5 0 4 6 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP03050 1. Type TP 3050
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
140 4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
007 5. Motor power 007 = 0.75 kW (IEC 80)
012 = 1.25 kW (IEC 90S)
018 = 1.8 kW (IEC 90L)
022 = 2.2 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 3050
Motor size b c** d f h m n p t* u v w x y*
80 500 406 124 285 352 103 228 125 25.5 92 155 82 50 25.5
90S / 90L 506 441 124 285 352 103 228 140 25.5 90 155 82 50 25.5
100L 618 490 134 335 403 103 278 160 25.5 112 155 85 50 25.5
112M 618 512 134 335 403 103 278 190 25.5 112 155 85 50 25.5
132S / 132M 719 569/609 154 410 444 103 332 216 25.5 132 155 85 50 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

92
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 3050, 4-pole (n=1,750 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225


USGPM
[ft] [m]
0 25 50 75 100 125 150 175
28 IGPM
100

Ø210 η 0.40 η 0.45 η 0.55


80 24

Ø200 η 0.60
70
η 0.61
20 Ø190
η 0.60
60
Impeller diameter

Ø180
16 η 0.55
Ø170
50 η 0.50

Standard TP
Ø160 η 0.45
40 12 Ø150 η 0.40
Ø140
30
8

20

10
4
60 Hz

4-pole
60 Hz
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

10 3 Ø210
Ø140 Standard TPS
2
5
1

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
P Q [m3/h]
[hp] [kW]
4
Required motor power

5 Ø210
4 3 Ø200
Ø190
3
2 Ø180
Ø170
2
Ø160
1 Ø150
1
Ø140
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

93
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 5060, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 45 m³/h
Pump head max. 24 m w.c.
Housing pressure max. 16 bar

Code T P 0 5 0 6 0 4 6 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP05060 1. Type TP 5060
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
155 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
215 = 215 mm 220 = 220 mm 225 = 225 mm
022 5. Motor power 022 = 2.2 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 5060
Motor size b c** d f h m n p t* u v w x y*
100L 622 494 137 335 403 114.5 278 160 27.5 112 230 85 51 25.5
112M 622 516 137 335 403 114.5 278 190 27.5 112 230 85 51 25.5
132S / 132M 723 573/613 157 410 444 114.5 332 216 27.5 132 230 85 51 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

94
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 5060, 4-pole (n=1,750 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225


USGPM
[ft] [m]
0 25 50 75 100 125 150 175
35 IGPM

100 30
η 0.50
Ø225 η 0.40
η 0.45 η 0.55 η 0.58
Ø215
25
η 0.58
Ø205 η 0.55
75 η 0.62
Impeller diameter

Ø195 η 0.50
20
Ø185 η 0.40
Ø175
η 0.45
50 15 Ø165
Ø155

Standard TP
10

25

5
60 Hz
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
NPSH Q [m3/h]
[ft] [m]

4-pole
60 Hz
2.5
Required NPSH-value

7.5
2.0 Ø225

5 1.5 Ø155

1.0
2.5 Standard TPS
0.5

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
P Q [m3/h]
[hp] [kW]
5
Ø225
6
Required motor power

4 Ø215
5 Ø205
4 3 Ø195

3 Ø185
2 Ø175
2 Ø165
1 Ø155
1

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

95
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 7060, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 80; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 65 m³/h
Pump head max. 27 m w.c.
Housing pressure max. 16 bar

Code T P 0 7 0 6 0 4 6 0 D N N F K 0 8 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP07060 1. Type TP 7060
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
155 4. Impeller 155 = 155 mm 160 = 160 mm 165 = 165 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 215 = 215 mm
220 = 220 mm 225 = 225 mm
022 5. Motor power 022 = 2.2 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 7060
Motor size b c** d f h m n p t* u v w x y*
100L 622 494 132 335 427 110 278 160 27.5 112 230 85 56 25.5
112M 622 516 132 335 427 110 278 190 27.5 112 230 85 56 25.5
132S / 132M 723 573/613 152 410 444 110 332 216 27.5 132 230 85 56 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

96
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 7060, 4-pole (n=1,750 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225 250 275 300 325
USGPM
[ft] [m]
0 25 50 75 100 125 150 175 200 225 250
100 30 IGPM

Ø225 η 0.50 η 0.55 η 0.60


90

25 Ø215
80 η 0.65
Ø205
η 0.60
70 η 0.66
20 Ø195
Impeller diameter

η 0.55
60 Ø185
η 0.50
Ø175
50 15
Ø165
Ø155
40

10
30

Standard TP
20
5

10
60 Hz
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
NPSH Q [m3/h]
[ft] [m]
12.0 3.5
Required NPSH-value

Ø225
10.0 3.0
Ø155

4-pole
60 Hz
8.0 2.5

6.0 2.0

1.5
4.0
1.0
2.0
0.5

0
Standard TPS
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
P Q [m3/h]
[hp] [kW]
10.0
7.0
9.0
Ø225
6.0
Required motor power

8.0

7.0 5.0 Ø215


6.0
Ø205
4.0
5.0
Ø195
4.0 3.0 Ø185

3.0 Ø175
2.0 Ø165
2.0 Ø155
1.0
1.0

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

97
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 8080, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 100; Pressure port (DS), DN 65
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 75 m³/h
Pump head max. 34 m w.c.
Housing pressure max. 16 bar

Code T P 0 8 0 8 0 4 6 0 D N N F K 1 0 0 0 6 5 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP08080 1. Type TP 8080
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
180 4. Impeller 180 = 180 mm 190 = 190 mm 200 = 200 mm 205 = 205 mm
210 = 210 mm 215 = 215 mm 220 = 220 mm 225 = 225 mm
230 = 230 mm 235 = 235 mm 240 = 240 mm 245 = 245 mm
250 = 250 mm
040 5. Motor power 040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 8080
Motor size b c** d f h m n p t* u v w x y*
112M 641 535 136 335 403 124 278 190 27.5 112 250 85 71 25.5
132S / 132M 742 592/632 156 410 444 124 332 216 27.5 132 250 85 71 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

98
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 8080, 4-pole (n=1,750 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225 250 275 300 325
USGPM
[ft] [m]
0 25 50 75 100 125 150 175 200 225 250 275
IGPM
Ø250 η 0.40 η 0.45 η 0.50 η 0.55
34 η 0.60
32 Ø240
90 η 0.60
30
Ø230
28 η 0.64
Ø220 η 0.55
26
η 0.66
80 24 Ø210
Impeller diameter

22 Ø200

20 Ø190
60 18 Ø180

Standard TP
16
14
40 12
10
η 0.50
8
20 6
4
2 60 Hz
0 0

4-pole
60 Hz
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

1.5
Ø180 Ø250
6.0 2.0

1.5
4.0 Standard TPS
1.0
2.0
0.5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
P Q [m3/h]
[hp] [kW]
14 10 Ø250
Required motor power

12
8.0 Ø240
10
Ø230
8.0 6.0
Ø220
Ø210
6.0
4.0 Ø200
4.0 Ø190
2.0 Ø180
2.0
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

99
GEA Tuchenhagen
Standard version, centrifugal pump, type TP 16040, 4-pole (n=1,750 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 150; Pressure port (DS), DN 100
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 120 m³/h
Pump head max. 17 m w.c.
Housing pressure max. 16 bar

Code T P 1 6 0 4 0 4 6 0 D N N F K 1 5 0 1 0 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TP16040 1. Type TP 16040
4 2. Speed 4 = 4 pole
60 3. Frequency 60 = 60 Hz
160 4. Impeller 160 = 160 mm 165 = 165 mm 170 = 170 mm 175 = 175 mm
180 = 180 mm 185 = 185 mm 190 = 190 mm 195 = 195 mm
200 = 200 mm
040 5. Motor power 040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 132S)
075 = 7.5 kW (IEC 132M)

TP 16040
Motor size b c** d f h m n p t* u v w x y*
112M 651 545 131 335 403 108 278 190 29.5 112 280 85 86 27.5
132S / 132M 752 602/642 151 410 444 108 332 216 29.5 132 280 85 86 27.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

100
GEA Tuchenhagen
Performance curves, centrifugal pump, type TP 16040, 4-pole (n=1,750 min-1), 60 Hz

H 0 75 175 250 325 400 450 525 600


USGPM
[ft] [m]
0 50 100 150 200 250 300 350 400 450 500
IGPM
Ø200 η 0.50
60 18 η 0.55 η 0.60
η 0.65
η 0.67
Ø190
16
50 η 0.65
14
Ø180
η 0.60
Impeller diameter

40 12
Ø170
η 0.55
10
Ø160
30
8 η 0.50
η 0.40 η 0.45

20 6

Standard TP
4
10
2
60 Hz
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
NPSH Q [m3/h]
[ft] [m]
5
Required NPSH-value

15

4-pole
60 Hz
Ø200
12.5 4

10 3
7.5
2
5
Ø160
2.5 1 Standard TPS
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
P Q [m3/h]
[hp] [kW]

8 6
Ø200
Required motor power

7 5 Ø190
6
4 Ø180
5
4 3 Ø170
Ø160
3
2
2
1
1

0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

101
GEA Tuchenhagen
Performance characteristics 50 Hz, GEA Tuchenhagen®-VARIFLOW, Baureihe TPS

2-pole (n = 2,900 min-1)

H 0 50 100 150 200 250 300 350


USGPM
[ft] [m]
0 50 100 150 200 250 300
250 IGPM
70

200 60 50 Hz
50
150
40

TPS 3050
100 30

20
TPS 2030
50
10

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Q [m3/h]

102
GEA Tuchenhagen
Performance characteristics 60 Hz, GEA Tuchenhagen®-VARIFLOW, Baureihe TPS

2-pole (n = 3,500 min-1)

H 0 50 100 150 200 250 300 350 400


USGPM
[ft] [m]
0 50 100 150 200 250 300
110 IGPM
350

60 Hz
100

300 90

80
250
70

200 TPS 3050


60

50
150
40

100 30
TPS 2030
20
50
10
Standard TPS

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Q [m3/h]

103
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS, 2-pole (n=2,900 min-1), 50 Hz

Standard version 2 pole/50Hz


Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Depending on pump size
Mechanical seal Single-acting, material: C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Standard equipment Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 55 m3/h
Pump head max. 64 m w.c.

TPS 2030 und TPS 3050

2-pole (n=2,900 min-1), 50 Hz


H 0 50 100 150 200 250 300 350
USGPM
[ft] [m]
Performance characteristics TPS

0 50 100 150 200 250 300


250 IGPM
70

200

150
60

50
50 Hz
40

TPS 3050
100 30

20
TPS 2030
50
10

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Q [m3/h]

104
GEA Tuchenhagen
Example of a standard selection

Code T P S 2 0 3 0 2 5 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Standard version, for other versions see options

Example Pos Designation Code of selection characteristics


TPS 2030 1. Type TPS 2030 Selected values
2 2. Speed 2 = 2 pole determined by the
pump selected
50 3. Frequency 50 = 50 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm
140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm
022 5. Motor power 022 = 2.2 kW (IEC 90L)
Selection using the
030 = 3.0 kW (IEC 100L) characteristic curves
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)

Performance curves, centrifugal pump, TPS 2030 (2-polig / 50 Hz)

H 0 20 40 60 80 100 120 140 160


USGPM
[ft] [m]
0 20 40 60 80 100 120 140
44 IGPM
140
40 Ø160
η 0.20 η 0.25
120 36
η 0.30
Impeller diameter

32 Ø150
η 0.35 η 0.37
100
28 Ø140
η 0.37
80 24 Ø130
η 0.35
20 Ø120
Impeller selection in 60 η 0.30
accordance with capacity 16 Ø110
η 0.25
and pump head 40 12

2-pole
50 Hz
η 0.20
8
Standard TPS
20

0
4

0
50 Hz
0 5 10 15 20 25 30 35 40
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

40 12
10 Ø160
30
8 Ø110
20 6
4
10
2
0 0
0 5 10 15 20 25 30 35 40
P Q [m3/h]
[hp] [kW]
5.5
7.0 5.0 Ø160
Required motor power

6.0 4.5
Ø150
4.0
5.0 Ø140
3.5

4.0 3.0 Ø130


Motor output selection in
2.5 Ø120
accordance with capacity 3.0 Ø110
and pump head 2.0
2.0 1.5
1.0
1.0 0 5 10 15 20 25 30 35 40
Q [m3/h]

105
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 2030, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 32 m³/h
Pump head max. 37 m w.c.
Housing pressure max. 16 bar

Code T P S 2 0 3 0 2 5 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TPS2030 1. Type TPS 2030
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm
145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm
022 5. Motor power 022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.2 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)

TP 2030
Motor size b c** d f h m n p t* u v w x y*
90L 594 529 121.5 285 352 85 227 140 25.5 80 135 82 140.5 25.5
100L 706 578 131.5 335 403 85 227 160 25.5 90 135 85 140.5 25.5
112M (4 kW + 5.5 kW) 706 600 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5
112M (7.5 kW) 706 622 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5
132M 808 717.5 152 410 444 85 332 216 25.5 122 135 85 140.5 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

106
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 2030, 2-pole (n=2,900 min-1), 50 Hz

H 0 20 40 60 80 100 120 140 160


USGPM
[ft] [m]
0 20 40 60 80 100 120 140
44 IGPM
140
40 Ø 160
η 0.20 η 0.25
120 36
η 0.30

32 Ø 150
η 0.35 η 0,37
100
28 Ø 140
Impeller diameter

η 0.37
80 24 Ø 130
η 0.35
20 Ø 120
60 η 0.30
16 Ø 110

40 12 η 0.25

8 η 0.20

50 Hz
20
4

0 0
0 5 10 15 20 25 30 35 40
NPSH Q [m 3/h ]
[ft] [m]
Required NPSH-value

40 12
10 Ø 160
30
8 Ø 110
20 6
4
10

2-pole
50 Hz
2
Standard TPS
0 0
0 5 10 15 20 25 30 35 40
P Q [m 3/h ]
[hp] [kW]
5.5
7.0 5.0 Ø 160

4.5
Required motor power

6.0 Ø 150
4.0
5.0
3.5 Ø 140

4.0 3.0 Ø 130


Ø 120
2.5
3.0 Ø 110
2.0
2.0 1.5
1.0
1.0 0 5 10 15 20 25 30 35 40
Q [m 3/h ]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

107
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 3050, 2-pole (n=2,900 min-1), 50 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 400V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 55 m³/h
Pump head max. 64 m w.c.
Housing pressure max. 16 bar

Code T P S 3 0 5 0 2 5 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TPS3050 1. Type TPS 3050
2 2. Speed 2 = 2 pole
50 3. Frequency 50 = 50 Hz
140 4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
092 = 9.2 kW (IEC 132M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
185 = 18.5 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)

TP 3050
Motor size b c** d f h m n p t* u v w x y*
100L 729 600.5 133 335 403 103 227 160 25.5 90 155 85 161.5 25.5
112M (4 kW + 5.5 kW) 729 622.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5
112M (7.5 kW) 729 644.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5
132 M 830 740 153 410 444 103 332 216 25.5 122 155 85 161.5 25.5
160 L 999 886.5 183 640 598 103 408 254 25.5 150 155 110 161.5 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

108
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 3050, 2-pole (n=2,900 min-1), 50 Hz

H 0 50 100 150 200 250 300 350


USGPM
[ft] [m]
0 50 100 150 200 250 300
250 IGPM
70
Ø210 η 0.25
η 0.30
η 0.35
200 60 Ø200
η 0.40
η 0.42 η 0.44
Impeller diameter

Ø190
50
Ø180
150
Ø170
40
Ø160
η 0.42
Ø150
100 30 η 0.40
Ø140

η 0.35
20

50 Hz
η 0.30
50
η 0.25
10

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
NPSH Q [m3/h]
[ft] [m]
40 12
Required NPSH-value

10 Ø210
30
8
Ø140

20 6

4
10

2-pole
50 Hz
2 Standard TPS
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
P Q [m3/h]
[hp] [kW]
20
25
Required motor power

20 15 Ø 210

15 Ø 200
10 Ø 190
Ø 180
10 Ø 170
Ø 160
5 Ø 150
5 Ø 140

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

109
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS, 2-pole (n=3,500 min-1), 60 Hz

Standard version 2 pole/60Hz


Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Depending on pump size
Mechanical seal Single-acting, material: C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Standard equipment Stainless steel protection hood and base frame with height-adjustable
calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F, incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 69 m3/h
Pump head max. 95 m w.c.

TPS 2030 und TPS 3050

2-pole (n=3,500 min-1), 60 Hz

H 0 50 100 150 200 250 300 350 400


USGPM
[ft] [m]
0 50 100 150 200 250 300
110 IGPM
350
Performance characteristics TPS

100

300

250
90

80

70
60 Hz
200 TPS 3050
60

50
150
40

100 30
TPS 2030
20
50
10

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Q [m3/h]

110
GEA Tuchenhagen
Example of a standard selection

Code T P S 2 0 3 0 2 6 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Standard version, for other versions see options

Example Pos Designation Code of selection characteristics


TPS2030 1. Type TPS 2030 Selected values
2 2. Speed 2 = 2 pole determined by the
pump selected
60 3. Frequency 60 = 60 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm
140 = 140 mm 145 = 145 mm 150 = 150 mm
155 = 155 mm 160 = 160 mm
022 5. Motor power 022 = 2.2 kW (IEC 90L)
Selection using the
030 = 3.0 kW (IEC 100L) characteristic curves
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)

Performance curves, centrifugal pump, TPS 2030 (2-polig / 60 Hz)

H 0 25 50 75 100 125 150 175 200 225


USGPM
[ft] [m]
0 25 50 75 100 125 150 175
56 IGPM
Ø160 η 0.20 η 0.25
175 η 0.30

η 0.35
48
150 Ø150
η 0.37
Impeller diameter

40 Ø140
125
η 0.37
32 Ø130
100
Ø120 η 0.35

24 η 0.30
Impeller selection in 75 Ø110
accordance with capacity η 0.25
and pump head 16
50
η 0.20
Standard TPS
25 8
60 Hz
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
NPSH Q [m3/h]
Required NPSH-value

[ft] [m]
10
2-pole
60 Hz

30 Ø160
8
Ø110
20 6

4
10
2

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
P Q [m3/h]
[hp] [kW]
Required motor power

10
12 Ø160
8
10 Ø150
Ø140
8 6
Ø130
Motor output selection in 6
4 Ø120
accordance with capacity Ø110
4
and pump head
2
2

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
Q [m3/h]

111
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 2030, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 40
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 36 m³/h
Pump head max. 52 m w.c.
Housing pressure max. 16 bar

Code T P S 2 0 3 0 2 6 0 D N N F K 0 6 5 0 4 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TPS2030 1. Type TPS 2030
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
110 4. Impeller 110 = 110 mm 120 = 120 mm 130 = 130 mm 140 = 140 mm
145 = 145 mm 150 = 150 mm 155 = 155 mm 160 = 160 mm
022 5. Motor power 022 = 2.2 kW (IEC 90L)
030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)

TP 2030
Motor size b c** d f h m n p t* u v w x y*
90L 594 529 121.5 285 352 85 227 140 25.5 80 135 82 140.5 25.5
100L 706 578 131.5 335 403 85 227 160 25.5 90 135 85 140.5 25.5
112M (4 kW + 5.5 kW) 706 600 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5
112M (7.5 kW) 706 622 131.5 335 403 85 227 190 25.5 102 135 85 140.5 25.5
132M 808 717.5 152 410 444 85 332 216 25.5 122 135 85 140.5 25.5

(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

112
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 2030, 2-pole (n=3,500 min-1), 60 Hz

H 0 25 50 75 100 125 150 175 200 225


USGPM
[ft] [m]
0 25 50 75 100 125 150 175
56 IGPM
Ø160 η 0.20 η 0.25
175 η 0.30

η 0.35
48
150 Ø150
η 0.37

40 Ø140
125
η 0.37
Impeller diameter

32 Ø130
100
Ø120 η 0.35

24
75 Ø110 η 0.30

16 η 0.25
50
η 0.20

25 8
60 Hz
0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
NPSH Q [m3/h]
[ft] [m]
10
30
Required NPSH-value

Ø160
8
Ø110
20 6

4
10 Standard TPS
2

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
P Q [m3/h]
[hp] [kW]
2-pole
60 Hz

10
12 Ø160
Required motor power

8
10 Ø150

8 6 Ø140
Ø130
6 Ø120
4
Ø110
4
2
2

0 0
0 4 8 12 16 20 24 28 32 36 40 44 48 52
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

113
GEA Tuchenhagen
Standard version, centrifugal pump, type TPS 3050, 2-pole (n=3,500 min-1), 60 Hz
Materials Pump housing, 316L (1.4404), deep-drawn
impeller, 316L (1.4409), precision casting
Connections DIN 11853-2 hygienic grooved flange (flange connection optional)
Nominal width of connections Suction port (SS), DN 65; Pressure port (DS), DN 50
Mechanical seal Single-acting, material C / SIC / EPDM
Static seals EPDM (FDA, USP Class VI)
Equipment Stainless steel protection hood and base frame with
height-adjustable calotte-type feet
Motor Standard IEC motor, 3-phase 460V/±5%, IM B35, IP55, ISO class F,
incl. thermistor, IE3
Documentation Operating instructions, declaration of conformity
Flow rate max. 69 m³/h
Pump head max. 95 m w.c.
Housing pressure max. 16 bar

Code T P S 3 0 5 0 2 6 0 D N N F K 0 6 5 0 5 0 E K E - 1 - J J -
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Example Pos Designation Code of selection characteristics
TPS3050 1. Type TPS 3050
2 2. Speed 2 = 2 pole
60 3. Frequency 60 = 60 Hz
140 4. Impeller 140 = 140 mm 150 = 150 mm 160 = 160 mm 170 = 170 mm
175 = 175 mm 180 = 180 mm 185 = 185 mm 190 = 190 mm
195 = 195 mm 200 = 200 mm 205 = 205 mm 210 = 210 mm
030 5. Motor power 030 = 3.0 kW (IEC 100L)
040 = 4.0 kW (IEC 112M)
055 = 5.5 kW (IEC 112M)
075 = 7.5 kW (IEC 112M)
110 = 11.0 kW (IEC 132M)
150 = 15.0 kW (IEC 132M)
212 = 21.2 kW (IEC 160L)
220 = 22.0 kW (IEC 160L)

TP 3050
Motor size b c** d f h m n p t* u v w x y*
100L 729 600.5 133 335 403 103 227 160 25.5 90 155 85 161.5 25.5
112M (4 kW + 5.5 kW) 729 622.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5
112M (7.5 kW) 729 644.5 133 335 403 103 227 190 25.5 102 155 85 161.5 25.5
132 M 830 740 153 410 444 103 332 216 25.5 122 155 85 161.5 25.5
160 L 999 886.5 183 640 598 103 408 254 25.5 150 155 110 161.5 25.5
(*) Dimensions t and y only apply to the hygienic grooved flange acc. to DIN 11853-2 for the relevant standard nominal width
(**) Dimension c refers to our standard motors All dimensions in mm

114
GEA Tuchenhagen
Performance curves, centrifugal pump, type TPS 3050, 2-pole (n=3,500 min-1), 60 Hz

H 0 50 100 150 200 250 300 350 400


USGPM
[ft] [m]
0 50 100 150 200 250 300
110 IGPM
350
100
Ø210 η 0.25
300 90 η 0.30 η 0.35
Ø200 η 0.40
η 0.42
80
250 Ø190 η 0.44
Impeller diameter

70 Ø180

200 60 Ø170

Ø160
50
150 Ø150 η 0.42
40 Ø140 η 0.40

100 30 η 0.35

η 0.30
20

60 Hz
η 0.25
50
10

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
NPSH Q [m3/h]
[ft] [m]
Required NPSH-value

40 12
Ø210
Ø140
10
30
8
20 6

10 4
2
Standard TPS
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
P Q [m3/h]
[hp] [kW]
30
2-pole
60 Hz

35
25 Ø 210
Required motor power

30
20 Ø 200
25
Ø 190
20 15 Ø 180
Ø 170
15 Ø 160
10 Ø 150
10 Ø 140
5
5

0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Q [m3/h]
The flow charts are based on a pumping medium of:
densitiy 1 kg/dm3, viscosity 1 mm2/s, temperature 15°C, tolerance ±7%

115
GEA Tuchenhagen
Options for TP and TPS series

Standard D N N F K - - - - E K E - 1 - J J -
Options
Position 1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17

Example Pos Designation Code of selection characteristics


6. Nominal width DN = DIN 11850
standard OD = Zoll OD

DN DN DN OD OD
40, 50, 100 125, 150 1.5“, 2“ 4“
65, 80 2.5“, 3“

*1) *2) *2)


GSK 7. Connection type NFK = Hygienic grooved flange
DIN 11853-2 (standard)
*2) *2)
ASK = Hygienic flange connection
DIN 11853-2, cpl.
*2) *2)
GO = Male part
DIN 11851
*2) *2)
GK = Pipe connection
DIN 11851, cpl.
TN = VARIVENT® grooved flange
TK = VARIVENT® flange connection
*2) *2) *2)
GSK = Hygienic male part
DIN 11853-1
*2) *2) *2)
AVK = Hygienic union
DIN 11853-1, cpl.
CO = Tri-Clamp analogous to DN not available
DIN 32676 / ISO 2852
SMG = SMS male part DN not available
SMK = SMS connection cpl. DN not available

8. Connection sizes 040 = DN 40 112 = 1.5" OD TP 1020


suction side (SS) 050 = DN 50 200 = 2" OD TP 1020 TP 2050
TP 2030 TP 3050
065 = DN 65 212 = 2.5" OD TP 1540 TP 2575 TP 7060
TP 2030 TP 3050 TPS 2030
TP 2050 TP 5060 TPS 3050
080 = DN 80 300 = 3" OD TP 1540 TP 3050 TP 8080
TP 2050 TP 5060
TP 2575 TP 7060
100 = DN 100 400 = 4" OD TP 8080 TP 16040
125 = DN 125 TP 16040
150 = DN 150 TP 16040
9. Connection sizes 040 = DN 40 112 = 1.5" OD TP 1020 TP 2030
Pressure side (DS) TP 1540 TPS 2030
050 = DN 50 200 = 2" OD TP 1020 TP 2050 TPS 2030
TP 1540 TP 2575 TPS 3050
TP 2030 TP 3050
065 = DN 65 212 = 2.5" OD TP 5060 TP 7060 TP 8080
080 = DN 80 300 = 3" OD TP 5060 TP 7060 TP 8080
100 = DN 100 400 = 4" OD TP 16040

*1) For TP 16040 on request


*2) Versions available on request

116
GEA Tuchenhagen
Options for TP and TPS series

Standard D N N F K - - - - E K E - 1 - J J -
Options
Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Example Pos Designation Code of selection characteristics


TP 1020 TP 2575 TPS 2030
TP 1540 TP 5060 TPS 3050
TP 2030 TP 7060
TP 2050 TP 8080
TP 3050 TP 16040
PS 10. Design / Single-acting
Material of EK = carbon / silicon carbide (standard)
mechanical seal EH = carbon / chrome molybdenum
ES = silicon carbide / silicon carbide

Single acting with flush


QK = with flush - carbon / silicon carbide
QH = with flush - carbon / chrome molybdenum
QS = with flush - silicon carbide / silicon carbide

Double-acting

Standard TP
PS = with flush - silicon carbide / silicon carbide
F 11. Static seals E = EPDM (Standard)
F = FKM
D 12. Drainage - = no drainage valve (standard)
D = drainage valve type VTP *3)
C = with drainage connection Tri-Clamp DN 15 *3)
(analogous to 32676 / ISO 2852)
3 13. Product contact 1 = Ra ≤ 3.2µm (Standard)
Surfaces 3 = Ra ≤ 0.8µm electro-polished

X 14. Explosion protection Motor power 0.75 kW 1.1 kW 1.5 kW 2.2 kW 3.0 kW 4.0 kW 5.5 kW

class*4) - = without (standard)


X = with ATEX
(II2G Eex d IIB T4)
Motor power 7.5 kW 11.0 kW 15.0 kW 18.5 kW 22.0 kW 30.0 kW 37.0 kW 45.0 kW
- = without (standard)
X = mit ATEX Standard TPS
(II2G Eex d IIB T4)

J 15. Stainless steel Motor size 80 90S/90L 100L 112M 132S/132M


protection J= with (standard)
N = without
Motor size 160L 200L 225M
J= with (standard)
N = without

J 16. Calotte-type frame Motor size 80 90S/90L 100L 112M 132S/132M


J= with (standard)
N = without
Options

Motor size 160L 200L 225M


J= with (standard)
N = without
17. Certificates -= without (standard)
Z
O = surface measurement report
Z= acceptance test certificate 3.1 DIN/EN 10204

*3) 2 pieces for TPS Pumps


*4) 30 kW ATEX on request

117
GEA Tuchenhagen
Options for TP and TPS series

Mechanical seal design options

Single-acting (standard) mechanical seal Single-acting, flushed (Quench) Double-acting mechanical seal
mechanical seal

Slide ring holder, Second slide ring


Shaft sealing ring and counter ring on both sides
and shaft protection sleeve
Crystallizing and Hazardous,
highly viscous products (≥100 cP) abrasive and dilatant fluids
Two sizes for the entire TP(S) program, easy to replace
Encapsulated spring, seal ring, counter ring, dead-space free

Drainage

Drainage valve type VTP Drainage connector Tri-Clamp 1/2“, DN 15


For complete draining of the pump Variable connection for individual
housing without any dead corners. draining
Safe closing function, even in the event
of pressure surges in the system.

Advantages of hygienic flange connection compared with dairy union

⊕Gap-free seal  No gap-free seal

⊕Defined defor-  Undefined defor-


mation of seal mation of seal

⊕Metallic stop  No metallic stop

Hygienic flange connection (DIN 11853-2) Dairy union (DIN 11851-1)

118
GEA Tuchenhagen
Special versions for TP and TPS series on request

Inducer for TP series VESTA® valves for draining Carriage for pump

Standard TP
Heating jacket for TP series

Also available on request:

• Other connection types


• Noise protection hood
• Other motor designs and manufacturers

Standard TPS

Options

119
GEA Tuchenhagen
Sealing sets and mechanical seals

TP Series

O-ring* Mechanical seal

O-ring* O-ring*

TPS Series

* included in sealing sets

Sealing sets
Pump type EPDM sealing set FKM sealing set
Part number Part number
TP 1020 244-000125 244-000128
TP 1540 244-000126 244-000129
TP 2030 244-000127 244-000130
TP 2050 244-001024 244-001032
TP 3050 244-000221 244-000222
TP 5060 244-000458 244-000466
TP 7060 244-001054 244-001055
TP 2575 244-000467 244-000468
TP 8080 244-000336 244-000384
TP 16040 244-000519 244-000520
TPS 2030 244-000696 244-000697
TPS 3050 244-000785 244-000786

Mechanical seals
Mechanical seal Pump type
TP 1020; TP(S) 2030; TP 1540; TP 5060; TP 7060; TP 2575;
Configuration TP 2050; TP(S) 3050 TP 8080; TP 16040
Type Material Part number Part number
EW/QU* C/SIC/EPDM 244-000045 244-000345
EW/QU* C/CrMo/EPDM 244-000531 244-000533
EW/QU* SIC/SIC/EPDM 244-000043 244-000382
EW/QU* C/SIC/FKM 244-000044 244-000381
EW/QU* C/CrMo/FKM 244-000532 244-000534
EW/QU* SIC/SIC/FKM 244-000042 244-000383
DW SIC/SIC/EPDM 244-000135 244-000378
DW SIC/SIC/FKM 244-000136 244-000379
Shaft seal 100-000014 924-342
* For mechanical seal QU is recommended to change the shaft seal in addition

120
GEA Mechanical Equipment

GEA Tuchenhagen GmbH


Am Industriepark 2-10, 21514 Büchen
Pumps
Phon +49-4155 49-0, Fax +49-4155 49-2428 Checklist
sales.geatuchenhagen@gea.com
www.tuchenhagen.com

1 Company / Cust. No:

Contact:

Phone: Fax: E-Mail:

2 Project / Tag No:


Pump performance

3 Flow parameters* Flow rate: (m3/h) Pressure: bar


4 Operating frequency £ 50 Hz £ 60 Hz
(if not given "50Hz" assumed)

5 Fluid Viscosity: Density:


(if not given "1 cP" assumed) (if not given "1 kg/dm3" assumed)
6 Application* £ nonself-priming (TP Series) £ self-priming (TPS Series)

7 Mechanical seals Execution: £ single acting (Standard) £ single flushed (Quench) £ double flushed
£ C / SIC (Standard) £ SIC / SIC (double floushes only in SIC / SIC!)
Gasket selection

(if unknown no. 9 essential!)


Material:

Standard TP
8 Static seals
(if unknown no. 9 essential!)
Material: £ EPDM (Standard) £ FKM (Viton®)

9 Fluid Medium: Temperature: Viscosity:

10 Connections £ Hygienic grooved flange DIN 11853-2 (standard) £ DIN 11853-2 (Hygienic flange) £ VARIVENT® flange
(suction and pressure nozzles)
£ SMS £ other: £ complete, incl. counterpiece

11 Version £ with stainless steel cover £ stainless steel cover with acoustic insulation
£ with adjustable calotte feet or £ carrier without electrical connection
£ carrier with electrical connection
(incl. safety switch and 10 m cable and plug)

12 Actuator / Motor existing supply voltage £ 3~ 400V/50Hz (Europe) £ 3~ 460V/60Hz


£ 3~ 200V/60Hz (e.g. Japan) £ 3~ 200V/50Hz (e.g. Japan)
£ 3~ 380V/60Hz (e.g. Brazil) £ other:
Manufacturer: £ GEA Tuchenhagen Standard or £ ABB
Protection class: R
Standard TPS
IP 55 (Standard)
ATEX: £ II G Eex d IIB T4 or £ II G Eex de IIB T4
Adjustment control: R Thermistor (PTC) (Standard)

13 Options Surface: £ matt blank (Standard) £ Ra ≤ 0.8 µm


(Product contacted)
Drain: £ Drainvalve VTP or £ Drainpipe
DN 15 with TriClamp
Heating: £ Heating- or cooling jackets
Certificates: £ 3.1 Certificate DIN/EN 10204 £ Performance test certificate
£ Surface measurement report

14 Marks / Other
Spare Parts

* Please fill out all required fields


The checklist can also be found on www.tuchenhagen.com

121
GEA Tuchenhagen
General Sales Terms and Conditions
of GEA Tuchenhagen GmbH
(Edition May 2003)
Any contract placed with us (hereinafter referred to as “the Article II Price and Payment
Seller”) by any private-law corporation, company or other
business or any public-law legal person or other entity 1. Unless expressly otherwise agreed upon, any price agreed
(hereinafter referred to as “the Buyer”) shall exclusively be between the Seller and the Buyer shall be ex works exclusive
subject to these Standard Sales Terms and these Standard Sales of any packaging. Each such price shall be exclusive of any
Terms shall be applicable to any transaction agreed between the sales tax which shall be billed by the Seller in addition to
Seller and the Buyer thereafter even if no express reference to said price at the rate which may be applicable at any time
these Standard Sales Terms is made in connection with any and from time to time.
such further transaction. The Seller hereby expressly refuses to
accept any standard terms of the Buyer referred to in any 2. Unless otherwise agreed upon, the price of any of the Goods
correspondence or other document placing any such order. shall be paid without any deduction for any reason
Notwithstanding any reference of the Buyer to any standard whatsoever as follows:
terms of the Buyer, the Buyer shall, upon the acceptance of any - One third upon the receipt of the Seller’s acceptance of the
delivery by the Seller to the Buyer, be deemed to have accepted contract placed by the Buyer
these Standard Sales Terms. No standard terms of the Buyer - One third upon the receipt by the Buyer of the Seller’s
shall be applicable to any contract or order placed by the Buyer notice that all main components of the Goods are ready for
with the Seller unless such terms have been accepted expressly shipment
by the Seller in writing and the performance of any such - The remaining sum upon the transfer of the risks of the
contract or order by the Seller shall not be deemed to be an Goods to the Buyer and upon the issuance of the Seller’s
acceptance of any terms of the Buyer by the Seller. final invoice for the Goods

Unless otherwise provided for in these Standard Sales Terms, 3. The Buyer shall not have the right to retain any payment
the relationship between the Seller and the Buyer shall be due to the Seller for any reason whatsoever and shall not
governed by the provisions of applicable law. deduct from any moneys due to the Seller any money owed
or allegedly owed by the Seller to the Buyer unless any such
If these Standard Sales Terms are otherwise inapplicable or counterclaim is undisputed by the Seller or has been
ineffective for any reason whatsoever, the sale of any goods awarded to the Buyer by a judgment from which no appeal
delivered by the Seller to the Buyer (“the Goods”) shall be can be taken.
subject to the reservations of Clause 6 in Article V hereinbelow.
4. If, during the period between the date on which any contract
Article I General Terms was awarded by the Buyer to or any order was placed by the
Buyer with the Seller and the date on which production for
1. Any bid or offer submitted by the Seller to the Buyer shall the performance of said contract or order commences, any
not be binding upon the Seller and unless otherwise labor, material and/or production costs associated with said
expressly agreed upon by the Seller and the Buyer, no contract or order increase for any reason for which the Seller
contract placed by the Buyer shall be effective unless is not liable and the cost of any of the Goods (as defined in
expressly accepted by the Seller in writing. Section 255 of the German Commercial Code) as determined
in accordance with generally accepted German accounting
2. The title to any sample, drawing or other document or principles is shown by the Seller to have risen by more than
information, whether reduced to writing or in electronic twenty percent (20%) since the date of contract award or
form, including but not limited to any copyrights or other order placement, then the Seller shall have the right to
rights associated therewith, which may be provided by the redetermine the price of any such Goods payable by the
Seller to the Buyer shall remain vested in the Seller and no Buyer under said contract or order provided however that
such sample, drawing or other document or information the Seller shall not be entitled to increase said price by more
may be made accessible by the Buyer to any third party. than the increase in said cost.

3. Any performance or other data or description of any Goods 5. The Buyer shall pay any amount owing to the Seller within
by the Seller in any brochure, price list, bid, proposal, offer seven (7) calendar days from the due date for the payment
or any other document which may form part of any such of said amount.
bid, proposal or offer shall be deemed to be approximate in
accordance with standard industry practices and shall not be Article III Delivery Time and Late Delivery
binding upon the Seller unless expressly accepted as binding
by the Seller and the Seller does not make any warranties 1. The time available to the Seller for the delivery of the Goods
whatsoever with respect to any properties of any of the (“Delivery Time”) shall be as agreed between the Parties in
Goods. the contract placed. The Seller shall not be obligated to
deliver within said Delivery Time unless all technical and
4. Commercial terms agreed between the Seller and the Buyer commercial details have been agreed upon order placement
shall be interpreted in accordance with Incoterms 2000. and the Buyer performs all of its obligations under said
contract or order such as, without limitation, any obligation

122
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

to obtain necessary certificates, approvals or permits from after delivery, processed or mixed or combined with any
agencies or authorities and the obligation to make any other things with the agreement of the Buyer or
advance payment provided that any non-satisfaction of any - any Goods manufactured or processed by the Seller are,
of the preceding conditions shall operate to increase the beyond trials or tests, used by the Buyer or by any third
Delivery Time reasonably and further provided that no delay party with the agreement of the Buyer or
for which the Seller may be liable shall operate to increase - the Goods are accepted by any purchaser from the Buyer
the Delivery Time. whatever may be earlier provided that any prior acceptance
under the contract awarded or the order placed by the Buyer
2. The Seller shall not be obligated to deliver any Goods or at law shall take precedence over any acceptance under
within the Delivery Time unless the Seller receives deliveries this Clause.
from its suppliers as and when ordered by the Seller
provided that the Seller shall notify the Buyer as soon as Article V Retention of Title
reasonably possible of any delay in delivery it may become
aware of. 1. The title to all Goods delivered by the Seller to the Buyer
shall remain vested in the Seller until the full payment of all
3. The Seller shall be deemed to have delivered within the accounts receivable by the Seller from the Buyer for any
Delivery Time if the Goods have left the Seller’s works prior reason whatsoever provided that under current account
to the expiry of the Delivery Time or the Seller has notified arrangements the title so retained shall be deemed to be
the Buyer prior to the expiry of the Delivery Time that the security for any balance owed to the Seller.
Goods are ready for Delivery.
The Buyer shall not dispose of any of the Goods the title to
4. If the Buyer fails to make any payment to the Seller under which is so vested in the Seller (“Title Reservation Goods”)
any contract or order whatsoever when said payment is due, other than in the Buyer’s ordinary course of business
the Seller shall, upon notice to the Buyer, have the right to provided that the Buyer shall no longer have the right so to
discontinue performance under the contract awarded or the dispose of any Title Reservation Goods if and as soon as the
order placed for the Goods until the payment the Buyer has Buyer fails to make payments when payments are due. The
failed to make when due has been received provided Buyer shall not have the right to pledge or to transfer by
however that the Seller shall not have said right if the way of security the title to any Title Reservation Goods. The
payment so due but not made is immaterial. Buyer shall be obligated to maintain the rights of the Seller
if the Title Reservation Goods are sold by the Buyer to any
5. If the Seller is unable to deliver any Goods within the third party under credit arrangements. The Buyer shall
Delivery Time for reasons of force majeure, due to any labor promptly notify the Seller of any lien of attachment,
dispute or due to any circumstances beyond the reasonable execution or garnishment or any seizure or the like relating
control of the Seller then the Delivery Time shall be to any Title Reservation Goods.
extended reasonably. The Seller shall notify the Buyer of the
commencement and the end of any such circumstances as The Buyer hereby assigns to the Seller and the Seller hereby
soon as may be reasonably possible. accepts the Buyer’s assignment of any title to payment for
any of the Goods resold by the Buyer to any purchaser and
Article IV Transfer of Risk and Acceptance any security received by the Buyer from any such purchaser
for any such payment provided however that the Buyer
1. Unless expressly otherwise agreed upon between the Seller shall, subject to any notice to the contrary given by the
and the Buyer, the Goods shall be delivered ex works. Seller, have the right to collect any such payment and to
enforce any such security at its cost. Upon the request of the
2. If the Goods to be delivered by Seller to the Buyer are Seller, the Buyer shall notify the Seller of the debtors against
divisible, then the Seller shall have the right to deliver and which titles to payment so assigned are held, the securities
to invoice to the Buyer said Goods in reasonable parts and provided therefor, the type and the amount of the debt of
the Buyer shall not have the right to retain payment for any each such debtor and the type and the amount of each such
such reasonable part on the grounds of the non-delivery of security and deliver to the Seller all documents which may
any other parts of the Goods. be necessary to collect any amount so owed by any such
debtor. Upon notice to the Buyer, the Seller shall have the
3. If any delivery by the Seller to the Buyer requires acceptance right to notify any such debtor of the assignment of the title
by the Buyer under any express provision of the order to payment by the Buyer to the Seller hereunder.
placed by the Buyer or at law, then any delivery by the Seller
to the Buyer shall be deemed to have been accepted by the 2. If the Goods are sold by the Buyer to any purchaser together
Buyer if and in as far as with any other goods the title to which is not vested in the
- any Goods manufactured or processed by the Seller are, Seller, then a share of the full title to payment of the Buyer
after delivery, sold to or allowed to be used by any third under said sale to said purchaser equal to the price of said
party or Goods agreed between the Buyer and the Seller shall be
- any Goods manufactured or processed by the Seller are, deemed to have been assigned by the Buyer to the Seller.

123
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

3. Upon the request of the Buyer, the Seller shall waive any subject to the Seller receiving the full price agreed between
title to Goods delivered by the Seller to the Buyer in as far as the Seller and the Buyer therefor.
the value of all Goods the title to which has been retained by
the Seller hereunder exceeds one hundred ten percent Article VI Defects
(110%) of the value of all titles to payment the Seller holds
against the Buyer. 1. General
4. The Buyer shall, as of the transfer of risks associated with
Title Reservation Goods, insure all Title Reservation Goods 1.1 If Section 377 or Sections 377 and 381 of the German
against any damage or loss or destruction as a result of any Commercial Code (sales and contract manufacture
fire, inundation, flooding or theft or any destruction or loss agreements between business organizations as defined in
or damage in transit provided that the Buyer shall notify the Section 1 et seq, of the German Commercial Code) are
Seller promptly of any such destruction or loss or damage applicable to the order placed, the Buyer shall notify the
and shall, upon the request of the Seller, provide to the Seller promptly of any patent defect in any of the Goods
Seller any documentation of any such loss or damage such provided that said notice shall be given no later than on the
as, without limitation, any expert report on said destruction fourth (4th) working day following the delivery of said
or loss or damage, the names of the insurers of said Goods Goods. Any latent defect in any of said Goods shall be
and, as requested by the Seller, the insurance policy or notified promptly by the Buyer to the Seller provided that
policies relating to the Title Reservation Goods or insurance said notice shall be given no later than on the fourth (4th)
certificates issued by the insurer or the insurers for the Title working day following the discovery of said defect. Each
Reservation Goods. The Buyer hereby assigns to the Seller, such notice of any defect in any of the Goods shall be in
conditionally as of the time of any such destruction or loss writing. The conditions applicable to any such notice and
of or damage to any Goods, any title against any insurer or the effects of a late notice of any defect in any of the Goods
any party liable for any such destruction or loss or damage shall furthermore be governed by the conditions of law
to a maximum amount equal to the price agreed for any (Sections 377, respectively 377 and 381 of the German
such Goods affected by any such destruction or loss or Commercial Code),
damage by way of security for all moneys owed by the
Buyer to the Seller. 1.2 If the Buyer is not a business organization, notice of any
patent defect in any of the Goods delivered by the Seller to
5. Any processing of any Title Reservation Goods by the Buyer the Buyer shall be given by the Buyer to the Seller within
shall be for the Seller and the Seller shall be deemed to be two (2) weeks following the delivery of said Goods in the
the processor for the purposes of Section 950 of the German case of sales and contract manufacture agreements and
Civil Code. If Title Reservation Goods are processed, within two (2) weeks following acceptance in the case of
combined or mixed with other goods the title to which is not service agreements. The term provided for hereinbefore shall
vested in the Seller, then a fraction of the title to the new be deemed to have been complied with if said notice is
product equal to the ratio between the price invoiced to the forwarded by the Buyer within said term and received by
Buyer for the Goods so processed, combined or mixed and the Seller within four (4) weeks from such delivery or
the sum of the price invoiced to the Buyer for the Goods so acceptance as the case may be. The Buyer shall not be
processed, combined or mixed and the price or prices entitled to any remedy for any patent defect in any of the
invoiced to the Buyer for the other goods so processed, Goods if the Buyer fails to give notice as aforesaid unless
combined or mixed shall be vested in the Seller. The Buyer and in as far as
shall be the custodian of any such new product the title to - the Seller is liable for said defect due to willful act, neglect
which is vested in the Seller in total or in part for the Seller. or omission, any act of bad faith or any gross negligence,
If any such Title Reservation Goods are processed, combined - said defect is covered by a warranty of the Seller in
or mixed with goods of the Buyer and the goods of the accordance with Section 443 of the German Civil Code or
Buyer are the main constituents of the new product thereby - said defect is claimed in connection with loss of human
created, then the Buyer shall be deemed to have transferred life, injury, impairment of health or loss of freedom
to the Seller a fraction of the title to any such new product provided that any liability of the Seller for any such defect
computed in accordance with the principles of the preceding shall be excluded in accordance with the provisions of law
sentence and shall be the custodian of said new product for such as but not limited to the provisions of Section 640,
the Seller. paragraph 2, or Section 442 of the German Civil Code if the
Buyer had known said defect or did not know said defect
The provisions of Clauses 1 through 4 hereinabove due to its own gross negligence.
applicable to Title Reservation Goods shall apply mutatis
mutandis to any new product obtained by processing, 2. Product Defects
combination or mixing in which the Seller acquires in total
or in part a title through the operation of this Clause. 2.1 If any of the Goods delivered by the Seller to the Buyer is
defective, the Seller shall remedy said defect by repair or
6. If these Standard Sales Terms have not been agreed replacement. If said remedial action fails, then, subject to the
effectively, any transfer of title to any of the Goods shall be provisions on damages in Article VII hereinbelow, the Buyer

124
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

shall be entitled to any of the remedies provided for by law. 3. Legal Defects

2.2 If any remedial action is taken by the Seller, then the Seller 3.1 The liability of the Seller for the Goods not to be in breach
shall bear all costs and expenses occasioned by the removal of any third-party industrial property rights or copyrights
of said defect such as, without limitation, any transportation shall be limited to the Federal Republic of Germany and the
or traveling expenses or any labor or material costs provided country in which the Buyer is registered. The Seller shall
however that any extra costs occasioned by the Buyer have no such liability for any other country, such as any
moving the Goods after delivery to a place other than the country to which the Goods may be moved by the Buyer,
registered premises of the Buyer shall be carried by the unless such other country has been notified by the Buyer to
Buyer unless the removal of said Goods is a use for which the Seller prior to awarding the contract or placing the order
the Goods are intended. for the Goods.

2.3 The Buyer shall give the Seller the time and the opportunity 3.2 If the use of the Goods delivered by the Seller to the Buyer is
which may be needed to remove any defect in any of the in breach of any third-party industrial property rights or
Goods provided that the Seller shall not be held liable for copyrights and the Seller is liable for said breach according
any consequences of not being given such time and to Clause 3.1 hereinabove, the Seller shall, at its cost, obtain
opportunity. for the Buyer the right to continue the use of said Goods or
modify said Goods in a manner reasonably acceptable to the
2.4 Any repair or replacement by the Seller with respect to any Buyer so that said Goods will no longer be in breach of any
Goods shall irrespective of the scope of any such repair or such industrial property rights or copyrights. If such rights
replacement not be deemed to be an acceptance of any cannot be obtained at reasonable commercial terms or
liability for any defect in any of the Goods claimed by the within a reasonable period of time and if the Goods cannot
Buyer provided that no persons other than legal be so modified, then the Buyer shall have the right, at its
representatives or procurators under Sect. 49 German discretion, to rescind the contract awarded by the Buyer to
Commercial Code (“Prokuristen”) of the Seller shall have the the Seller or the order placed by the Buyer with the Seller or
right to accept any liability for any defect on behalf of the to obtain from the Seller a reasonable reduction in the price
Seller. of said Goods.

2.5 If any defect in any of the Goods claimed by the Buyer The Seller shall in any such event further indemnify the
shows not to be a defect for which the Seller is liable, then Buyer against any undisputed claims or any claims
the Buyer shall reimburse to the Seller all costs reasonably determined by non-appealable court decision of the owners
incurred by the Seller to remove said alleged defect in good of such industrial property rights or copyrights.
faith provided that material and labor costs so incurred by
the Seller shall be reimbursed at the Seller’s standard rates 3.3 Subject to Clause 3.4 hereinbelow, the Buyer shall not have
applicable at the time when the alleged defect was so the rights under Clause 3.2 hereinabove, unless
removed. - the Buyer notifies the Seller promptly of any breach of
industrial property rights or copyrights claimed by any
2.6 The Buyer shall not be entitled to the removal by the Seller third party,
of any defect due to any of the following: - the Buyer reasonably supports the defense of any such
- Improper use of any Goods or use of any Goods for a claims by the Seller and allows the Seller to make
purpose for which the Goods are not fit or defective modifications as referred to in Clause 3.2 hereinabove,
installation or commissioning of the Goods by the Buyer or - the Buyer allows the Seller to defend at its own cost any
any third party such claim or to make any out-of-court settlement with
- Natural wear and tear, improper or negligent handling, respect to any such claim as the Seller may think fit,
improper maintenance or use of any unfit consumables or - the legal defect is not due to any instructions given by the
utilities Buyer to the Seller and
- Defective construction work, unsuitable foundations or - the legal defect is not due to any modification of the Goods
chemical, electrochemical or electrical interference unless by the Buyer or any use of the Goods not in conformity
caused by the Seller with the intended use.

2.7 The Seller shall not be held liable for the consequences of 3.4 Notwithstanding the limitations in Clauses 3.2 and 3.3
any improper or inappropriate removal of any defect in any hereinabove, the provisions laid down by law shall apply, if
of the Goods by the Buyer or any third party or any and in as far as
modification to any of the Goods made without the Seller’s - the title of the Buyer against the Seller is held under Section
prior consent. 478 or under Sections 651 and 478 of the German Civil Code,
- the Seller is liable for the breach of the industrial property
rights or the copyrights due to any willful act, neglect or
omission or any gross negligence on the part of the Seller,
- the Seller warranted (as provided for in Section 443 of the

125
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

German Civil Code) that the Goods will not violate any German Product Liability Act or
industrial property rights or copyrights or - if and in as far as the Seller is held liable under any
- any damages claimed as a result of any breach of any warranty in accordance with Section 443 of the German
industrial property rights or copyrights are on the grounds Civil Code agreed by the Seller to provide security to the
of any loss of life, injury, loss of health or loss of freedom. Buyer with respect to the loss or damage incurred by the
Buyer.
4. Warranties Under Section 443 of the German Civil Code
4. The provisions of Clauses 1 through 3 hereinabove shall not
No person other than a legal representative or a procurator operate to alter any of the provisions of law regarding the
under Sect. 49 German Commercial Code (“Prokuristen”) of onus probandi.
the Seller will have the right to agree any warranties
according to Section 443 of the German Civil Code. Article VIII Limitation

1. The period of limitation with respect to any defect shall be a


Article VII Liability and Damages period of one (1) year provided that said period shall be five
(5) years for any defect in any Goods serving as civil
1. The Seller shall be liable for any willful acts, neglects and engineering structure or structures or any defect in any civil
omissions and any gross negligence of its legal engineering structure caused by any Goods ordinarily used
representatives and/or any other persons authorized by the in civil engineering structures.
Seller to perform any of the obligations of the Seller under
any contract awarded to the Seller or order placed with the 2. The period of limitation with respect to any other cause
Seller (“Agent or Employee”). under the contract awarded or the order placed by the Buyer
or any other cause outside said contract or order shall be a
2. In the event of any ordinary negligence of any legal period of eighteen (18) months.
representative, Agent or Employee of the Seller, the liability
of the Seller shall be limited to liability for any loss or 3. Notwithstanding the provisions of Clauses 1 and 2 herein-
damage the Seller foresaw when the contract was awarded above, the periods of limitation allowed by law shall apply,
or the order was placed by the Buyer or should have if and in as far as
foreseen when the contract was awarded or the order was - the title held by the Buyer against the Seller is under
placed by the Buyer considering the circumstances the Seller Section 478 or Sections 651 and 478 of the German Civil
knew or should have known when the contract was awarded Code,
or the order was placed by the Buyer. - the title of the Buyer is held on the grounds of any willful
act, neglect or omission, any act of bad faith or any gross
If and in as far as any loss or damage suffered by the Buyer negligence on the part of any of the legal representatives,
due to the ordinary negligence of any legal representative, Agents or Employees of the Seller,
Agent or Employee of the Seller is compensated by any final - the title held by the Buyer against the Seller is on the
payment by any insurer under any insurance contract grounds of any loss of life, injury, loss of health or loss of
against loss or indemnity concluded by the Buyer or for the freedom of any person,
Buyer such as, but not limited to any liability, all-risks, - the title held by the Buyer against the Seller is under the
transportation, fire or business interruption insurance, the German Product Liability Act,
liability of the Seller shall be limited to any losses incurred - the title held is on the grounds of a third party title in rem
by the Buyer as a result of any such insurance claim such as, which grants any such third party a title to the surrender
without limitation, any increase in insurance premium. Any of the Goods (Sect. 438 para.1 subsubpara. a German Civil
liability of the Seller for any loss or damage caused by the Code) or
ordinary negligence of any of the legal representatives, - the title held is on the grounds of any title recorded in any
Agents or Employees of the Seller and covered by a final register of deeds (Sect. 438 para.1 subpara. b German Civil Code).
insurance payment to the Buyer shall be excluded. The provisions in Clauses 1 and 2 shall further not apply if
the title is held by the Buyer under a warranty of the Seller
Subject to the limitations provided for hereinbefore, any in accordance with Section 443 of the German Civil Code
liability of the Seller for any loss or damage caused by the provided that any such title shall exclusively be subject to
ordinary negligence of any legal representative, Agent or the provisions of Clause 4 hereinbelow.
Employee of the Seller shall for each incident be limited to
an amount of two hundred fifty thousand Euros (250,000 1). 4. The period of limitation applicable to any warranty of the
Seller in accordance with Section 443 of the German Civil
3. The exclusions and limitations of liability provided for Code shall commence upon the delivery of the Goods to the
hereinabove shall not apply, Buyer or, if acceptance by the Buyer is required by law,
- if and in as far as the Seller is held liable for any human upon the acceptance of the Goods by the Buyer provided
loss of life, injury or loss of health, that, in the event of bad faith, said period shall commence as
- if and in as far as the Seller is held liable under the provided for in Section 438, paragraph 3, of the German

126
GEA Tuchenhagen
General Sales Terms and Conditions of GEA Tuchenhagen GmbH (May 2003)

Civil Code. Said period shall terminate as provided for in shall have commercial, financial and economic implications
Section 438 of the German Civil Code unless a shorter which shall be as close to those of said ineffective provision
period has been agreed according to the terms of the as may be reasonably.
warranty under Section 443 of the German Civil Code.

5. Clauses 1 through 4 hereinabove shall not operate to alter


any of the provisions of Sections 196, 197 and 479 of the
German Civil Code or any of the provisions of law applicable
to the onus probandi.

Article IX Software Use

If the contract awarded by the Buyer to the Seller or the order


placed by the Buyer with the Seller provides for the supply of
software, the Buyer will be granted a non-exclusive right to use
said software and any documentation of said software. Said
software will be supplied by the Seller to the Buyer for use with
the Goods delivered by the Seller to the Buyer provided that the
Buyer shall not have the right to use said software on more than
one system.

Any copying, modification or translation of said software or any


conversion of the object code of said software into source code
shall be limited as provided for in Section 69 et seq. of the
German Copyright Act. The Buyer agrees not to remove from
said software any reference to the developer of said software
such as, without limitation, any copyright reference and not to
modify any such reference unless the prior express content of
the Seller has been obtained.

Any other rights associated with such software and any


documentation of said software and any copies thereof shall
remain vested in the Seller or the supplier of said software as
the case may be. The Buyer shall not grant any sub-license.

Article X Applicable Law and Jurisdiction

1. The relationship between the Seller and the Buyer shall


exclusively be governed by the law of the Federal Republic
of Germany as the same may be applicable to the
relationship between two German parties provided however
that the application of the United Nations Convention on
Contracts for the International Sale of Goods of 11 April 1980
shall be excluded.

2. If the Buyer is a business or any public-law legal person or


other entity, any dispute between the Seller and the Buyer
shall be settled by the courts having jurisdiction at the
registered offices of the Seller provided however that the
Seller shall have the right to bring action against the Buyer
in the courts having jurisdiction at the registered offices of
the Buyer.

3. If any of the terms and conditions of the Contract or these


Standard Sales Terms is or become ineffective, the
remaining provisions of the Contract and these Standard
Sales Terms shall remain in full force and effect. Any such
ineffective provision shall be deemed to have been replaced
by the Seller and the Buyer by an effective provision which

127
Notes
129
GEA Tuchenhagen
We live our values.
Excellence • Passion • Integrity • Responsibility • GEA-versity

GEA Group is a global engineering company with multi-billion euro sales and operations in more than
50 countries. Founded in 1881, the company is one of the largest providers of innovative equipment and
process technology. GEA Group is listed in the STOXX® Europe 600 Index.

GEA Tuchenhagen-Pumps 07/2014

GEA Mechanical Equipment


GEA Tuchenhagen GmbH

Am Industriepark 2-10, 21514 Büchen, Germany


Phone +49-4155 49-0
sales.geatuchenhagen@gea.com, www.gea.com

You might also like