This document is a tower packing data sheet that provides specifications for a packing section of a tower. It includes information on the customer, plant location, volume of packing, rates and properties of the vapor and liquid, maximum pressure drop per foot of packing, design load percentage, and mechanical design details of the tower including diameter, packing type and materials. The notes specify that the packing is designed to operate at 50-100% of the listed loads and can handle overloads as advised by the packing vendor.
This document is a tower packing data sheet that provides specifications for a packing section of a tower. It includes information on the customer, plant location, volume of packing, rates and properties of the vapor and liquid, maximum pressure drop per foot of packing, design load percentage, and mechanical design details of the tower including diameter, packing type and materials. The notes specify that the packing is designed to operate at 50-100% of the listed loads and can handle overloads as advised by the packing vendor.
This document is a tower packing data sheet that provides specifications for a packing section of a tower. It includes information on the customer, plant location, volume of packing, rates and properties of the vapor and liquid, maximum pressure drop per foot of packing, design load percentage, and mechanical design details of the tower including diameter, packing type and materials. The notes specify that the packing is designed to operate at 50-100% of the listed loads and can handle overloads as advised by the packing vendor.
ITEM NO.: SERVICE: CUSTOMER: PLANT LOCATION: TOWER PACKING LOADINGS SECTION CASE VOLUME OF PACKING: PACKING SECTION VAPOR: RATE, Kg/Hr DENSITY, Kg/M3 (@T & P) MOLECULAR WT. TEMPERATURE, oC PRESSURE, Kg/cm2 abs LIQUID: RATE, Kg/Hr DENSITY, Kg/M3 (@T) TEMPERATURE, oC SURFACE TENSION, Dynes/cm VISCOSITY, cps MAX DP in. of H2O per foot of packing
DESIGN LOAD % OF FLOOD
MAX. GUARANTEED % FLOOD % OVER CAPACITY MECHANICAL DESIGN TOWER DIAMETER (ID), mm
PACKING TYPE: PACKING SIZE:, mm
MATERIAL & THICKNESS: PACKING
DISTRIBUTOR BOLTING SUPPORTS BED HOLD DOWN TRAY SUPPORT PLATE NOTES n 1. Design operation to be 50 to 100% of loads shown. Packing not to be limited to loads shown but designed to full capacity consistent with stable and efficient operation at above loads, with vapor and liquid ratios in same proportion as above. Packing vendor to advise percent overload the packing can handle. n 2. Abbreviations: CS - carbon steel, 410 SS -12% chromium alloy, 304-18-8 Stainless Steel.
VEI Job No. 4494-011 Sheet 1 of 1 02/19/2018 09:26:41